Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Improved thermoelectrically cooled quartz crystal microbalance

Design changes in the thermoelectrically-cooled quartz microbalance, which is used to monitor surface contamination in space simulation chambers, is described in terms of its extended temperature range, increased temperature control, mass sensitivity, and cooling power. The mass sensor uses 20 MHz quartz crystals having a sensitivity of 8.8 x 10 to the minus tenth power g/sq cm - Hz. The crystals are optically polished, metal plated, and overplated with magnesium fluoride to simulate an optical surface. The microbalance temperature circuitry is designed to readout and control surface temperature between 100 C and minus 59 C to plus or minus 0.5 C, and readout only temperature between minus 60 C and minus 199 C using auxiliary liquid nitrogen cooling. Data is included on the measurement of oil contamination of surfaces as a function of temperature in space simulation chambers.

D. McKeown↗

Thermoluminescence and the shock and reheating history of meteorites. II - Annealing studies of the Kernouve meteorite

Samples of the unshocked, equilibrated chondrite, Kernouve (H6), have been annealed for 1-100 hours at 500-1200 C, their thermoluminescence sensitivity measured and Na, K, Mn, Ca, and Sc determined by instrumental neutron activation analysis. The TL sensitivity decreased with temperature until by 1000 C it had fallen by 40 percent. The process responsible has an activation energy of 8 kcal/mole and probably involves diffusion. Samples annealed 1000-1200 C had TL sensitivities 0.01 times the unannealed values, most of the decrease occurring at 1100 C. This process has an activation energy of 100 kcal/mole and is probably related to the melting of the TL phosphor, feldspar, with some decomposition and loss of Cs, Na and K. Meteorites whose petrography indicates heating above 1100 C by natural shock heating events (shock facies d-f), have TL sensitivities similar to samples annealed above 1100 C.

Sears, D. W. G.↗

Drivers of Precipitation Change: An Energetic Understanding

The response of the hydrological cycle to climate forcings can be understood within the atmospheric energy budget framework. In this study precipitation and energy budget responses to five forcing agents are analyzed using 10 climate models from the Precipitation Driver Response Model Intercomparison Project (PDRMIP). Precipitation changes are split into a forcing-dependent fast response and a temperature-driven hydrological sensitivity. Globally, when normalized by top-of-atmosphere (TOA) forcing, fast precipitation changes are most sensitive to strongly absorbing drivers (CO2, black carbon). However, over land fast precipitation changes are most sensitive to weakly absorbing drivers (sulfate, solar) and are linked to rapid circulation changes. Despite this, land-mean fast responses to CO2 and black carbon exhibit more intermodel spread. Globally, the hydrological sensitivity is consistent across forcings, mainly associated with increased longwave cooling, which is highly correlated with intermodel spread. The land-mean hydrological sensitivity is weaker, consistent with limited moisture availability. The PDRMIP results are used to construct a simple model for land-mean and sea-mean precipitation change based on sea surface temperature change and TOA forcing. The model matches well with CMIP5 ensemble mean historical and future projections, and is used to understand the contributions of different drivers. During the twentieth century, temperature-driven intensification of land-mean precipitation has been masked by fast precipitation responses to anthropogenic sulfate and volcanic forcing, consistent with the small observed trend. However, as projected sulfate forcing decreases, and warming continues, land-mean precipitation is expected to increase more rapidly, and may become clearly observable by the mid-twenty-first century.

Richardson, T. B.↗

A New Raman Water Vapor Lidar Calibration Technique and Measurements in the Vicinity of Hurricane Bonnie

The NAcA/Goddard Space Flight Center Scanning Raman Lidar has made measurements of water vapor and aerosols for almost ten years. Calibration of the water vapor data has typically been performed by comparison with another water vapor sensor such as radiosondes. We present a new method for water vapor calibration that only requires low clouds, and surface pressure and temperature measurements. A sensitivity study was performed and the cloud base algorithm agrees with the radiosonde calibration to within 10- 15%. Knowledge of the true atmospheric lapse rate is required to obtain more accurate cloud base temperatures. Analysis of water vapor and aerosol measurements made in the vicinity of Hurricane Bonnie are discussed.

Evans, Keith D.↗

A New Raman Water Vapor Lidar Calibration Technique and Measurements in the Vicinity of Hurricane Bonnie

The NASA/Goddard Space Flight Center Scanning Raman Lidar has made measurements of water vapor and aerosols for almost ten years. Calibration of the water vapor data has typically been performed by comparison with another water vapor sensor such as radiosondes. We present a new method for water vapor calibration that only requires low clouds, and surface pressure and temperature measurements. A sensitivity study was performed and the cloud base algorithm agrees with the radiosonde calibration to within 10-15%. Knowledge of the true atmospheric lapse rate is required to obtain more accurate cloud base temperatures. Analysis of water vapor and aerosol measurements made in the vicinity of Hurricane Bonnie are discussed.

Evans, Keith D.↗

Electronic and Interfacial Properties of PD/6H-SiC Schottky Diode Gas Sensors

Pd/SiC Schottky diodes detect hydrogen and hydrocarbons with high sensitivity. Variation of the diode temperature from 100 C to 200 C shows that the diode sensitivity to propylene is temperature dependent. Long-term heat treating at 425 C up to 140 hours is carried out to determine the effect of extended heat treating on the diode properties and gas sensitivity. The heat treating significantly affects the diode's capacitive characteristics, but the diode's current carrying characteristics are much more stable with a large response to hydrogen. Scanning Electron Microscopy and X-ray Spectrometry studies of the Pd surface after the heating show cluster formation and background regions with grain structure observed in both regions. The Pd and Si concentrations vary between grains. Auger Electron Spectroscopy depth profiles revealed that the heat treating promoted interdiffusion and reaction between the Pd and SiC dw broadened the interface region. This work shows that Pd/SiC Schottky diodes have significant potential as high temperature gas sensors, but stabilization of the structure is necessary to insure their repeatability in long-term, high temperature applications.

Chen, Liang-Yu↗

Evaluation of an oil-debris monitoring device for use in helicopter transmissions

Experimental tests were performed on an OH-58A helicopter main-rotor transmission to evaluate an oil-debris monitoring device (ODMD). The tests were performed in the NASA 500-hp Helicopter Transmission Test Stand. Five endurance tests were run as part of a U.S. Navy/NASA/Army advanced lubricants program. The tests were run at 100 percent design speed, 117-percent design torque, and 121 C (250 F) oil inlet temperature. Each test lasted between 29 and 122 hr. The oils that were used conformed to MIL-L-23699 and DOD-L-85734 specifications. One test produced a massive sun-gear fatigue failure; another test produced a small spall on one sun-gear tooth; and a third test produced a catastrophic planet-bearing cage failure. The ODMD results were compared with oil spectroscopy results. The capability of the ODMD to detect transmission component failures was not demonstrated. Two of the five tests produced large amounts of debris. For these two tests, two separate ODMD sensors failed, possibly because of prolonged exposure to relatively high oil temperatures. One test produced a small amount of debris and was not detected by the ODMD or by oil spectroscopy. In general, the ODMD results matched the oil spectroscopy results. The ODMD results were extremely sensitive to oil temperature and flow rate.

Lewicki, David G.↗

The accuracy of temperature distributions used to derive the net transport for a zonally averaged model

Comparisons of satellite-derived temperatures with correlative temperatures indicate that the LIMS temperatures are accurate and contain more of the needed vertical resolution for calculating a residual mean circulation for transporting tracer-like species. Generally, the LIMS temperatures are accurate to at least 2 K. Other satellite data sets are comprised of temperatures with coarser vertical resolution, leading to biases that occur with an error pattern that is characteristic of their resolution. Their biases exceed 2 K at some altitudes. Retrievals of species using an infrared limb emission technique are sensitive to any temperature bias. Generally, the IMS comparisons with other data sets for ozone and water vapor are good to better than 20 percent; this represents an independent confirmation of the quality of LIMS and temperatures. Zonal mean comparisons between LIMS and SAMS temperatures also indicate agreement to better than 2 K from about 7 to 2hPa. Therefore, we are confident that SAMS N2O and CH4 are relatively free of temperature bias in that region. These factors support the generally good agreement in G90 between model N2O transported using a LIMS-derived RMC and the N2O contours from SAMS.

Remsberg, Ellis E.↗

Low Temperature Creep of Hot-Extruded Near-Stoichiometric NiTi Shape Memory Alloy: Effect of Thermal Cycling - Part 2

This paper is the first report on the effect prior low temperature creep on the thermal cycling behavior of NiTi. The isothermal low temperature creep behavior of near-stoichiometric NiTi between 300 and 473 K was discussed in Part I. The effect of temperature cycling on its creep behavior is reported in the present paper (Part II). Temperature cycling tests were conducted between either 300 or 373 K and 473 K under a constant applied stress of either 250 or 350 MPa with hold times lasting at each temperature varying between 300 and 700 h. Each specimen was pre-crept either at 300 or at 473 K for several months under an identical applied stress as that used in the subsequent thermal cycling tests. Irrespective of the initial pre-crept microstructures, the specimens exhibited a considerable increase in strain with each thermal cycle so that the total strain continued to build-up to 15 to 20 percent after only 5 cycles. Creep strains were immeasurably small during the hold periods. It is demonstrated that the strains in the austenite and martensite are linearly correlated. Interestingly, the differential irrecoverable strain, in the material measured in either phase decreases with increasing number of cycles, similar to the well-known Manson-Coffin relation in low cycle fatigue. Both phases are shown to undergo strain hardening due to the development of residual stresses. Plots of true creep rate against absolute temperature showed distinct peaks and valleys during the cool-down and heat-up portions of the thermal cycles, respectively. Transformation temperatures determined from the creep data revealed that the austenitic start and finish temperatures were more sensitive to the pre-crept martensitic phase than to the pre-crept austenitic phase. The results are discussed in terms of a phenomenological model, where it is suggested that thermal cycling between the austenitic and martensitic phase temperatures or vice versa results in the deformation of the austenite and a corresponding development of a back stress due to a significant increase in the dislocation density during thermal cycling.

Raj, S. V.↗

Line formation in the solar chromosphere. I - The C II resonance lines observed with OSO 8

The temperature structure of the upper chromosphere is investigated using center-to-limb measurements of the C II resonance lines at 1335 A from the University of Colorado spectrometer aboard OSO 8. Spectrum synthesis of these lines shows them to be extremely sensitive to the temperature and the physical extent of the 20,000 K plateau proposed by Vernazza et al (1973). Hydrostatic equilibrium models of the quiet chromosphere are computed to obtain theoretical spectra of the Lyman lines and continuum as well as the center-to-limb behavior of the C II lines. Good agreement is found with observations for a plateau at 16,500 K with about 25% more material than that of Vernazza et al.

Lites, B. W.↗

Rugged fast-response temperature probe

Very-sensitive probe uses tungsten sensor wire wrapped around to notched electrodes. Design combines ruggedness of earlier but less sensitive probe using very-short sensor wire with very-sensitive but fragile version with sensor wires wrapped around non-conducting frames.

Bailey, P. L.↗

Processing Robustness for A Phenylethynyl Terminated Polyimide Composite

The processability of a phenylethynyl terminated imide resin matrix (designated as PETI-5) composite is investigated. Unidirectional prepregs are made by coating an N-methylpyrrolidone solution of the amide acid oligomer (designated as PETAA-5/NMP) onto unsized IM7 fibers. Two batches of prepregs are used: one is made by NASA in-house, and the other is from an industrial source. The composite processing robustness is investigated with respect to the prepreg shelf life, the effect of B-staging conditions, and the optimal processing window. Prepreg rheology and open hole compression (OHC) strengths are found not to be affected by prolonged (i.e., up to 60 days) ambient storage. Rheological measurements indicate that the PETAA-5/NMP processability is only slightly affected over a wide range of B-stage temperatures from 250 deg C to 300 deg C. The OHC strength values are statistically indistinguishable among laminates consolidated using various B-staging conditions. An optimal processing window is established by means of the response surface methodology. IM7/PETAA-5/NMP prepreg is more sensitive to consolidation temperature than to pressure. A good consolidation is achievable at 371 deg C (700 deg F)/100 Psi, which yields an RT OHC strength of 62 Ksi. However, processability declines dramatically at temperatures below 350 deg C (662 deg F), as evidenced by the OHC strength values. The processability of the IM7/LARC(TM) PETI-5 prepreg was found to be robust.

Hou, Tan-Hung↗

Contraction kinetics of ventricular muscle from hibernating and nonhibernating mammals.

Temperature-dependent studies of excitability and tension-production kinetics were made on isolated trabecular strips from hibernating hamsters (HH), nonhibernating hamsters (CH), and from rats (R). The strips were electrically driven and isometric tension along with its first time derivative (dP/dt) were recorded. Excitabilities of both hamster tissues were greater than that of rat tissue from 5 to 38 C with HH greater than CH. Peak tension production followed the order of HH greater than CH greater than R at all temperatures below 24 C. Rat preparations showed an optimum peak tension production at about 31 C while HH and CH showed optima between 17 and 24 C. Times to maximal rates of tension rise showed significant variation. In this respect, the order of sensitivity to decreasing temperature was HH greater than CH greater than R.

South, F. E.↗

Experimental evaluation of the ignition process of carbon monoxide and oxygen in a rocket engine

Carbon monoxide and oxygen ignition boundaries were determined in a spark torch igniter as a function of propellant inlet temperatures. The oxygen temperature was varied from ambient to -258 F, and the carbon monoxide temperature was varied from ambient to -241 F. With the oxygen and carbon monoxide at -253 F and -219 F, respectively, they successfully ignited between mixture ratios of 2.42 and 3.10. Analysis of the results indicated that the lower ignition boundary was more sensitive to oxygen temperature than to carbon monoxide temperature. Another series of tests was performed in a small simulated rocket engine with oxygen at -197 F and carbon monoxide at -193 F. An oxygen/hydrogen flame was used to initiate combustion of the oxygen and carbon monoxide. Tests performed at the optimum operating mixture ratio of 0.55 obtained steady-state combustion in every test.

Linne, Diane L.↗

A progress report on using bolometers cooled by adiabatic demagnetization refrigeration

For sensitive detection of astronomical continuum radiation in the 200 micron to 3 mm wavelength range, bolometers are presently the detectors of choice. In order to approach the limits imposed by photon noise in a cryogenically cooled telescope in space, bolometers must be operated at temperatures near 0.1 K. Researchers report progress in building and using bolometers that operate at these temperatures. The most sensitive bolometer had an estimated noise equivalent power (NEP) of 7 x 10(exp 017) W Hz(exp -1/2). Researchers also briefly discuss the durability of paramagnetic salts used to cool the bolometers.

Lesyna, L.↗

Fiber Bragg Grating Filter High Temperature Sensors

We present a scaled-down method for determining high temperatures using fiber-based Bragg gratings. Bragg gratings are distributed along the length of the optical fiber, and have high reflectivities whenever the optical wavelength is twice the grating spacing. These spatially distinct Bragg regions (located in the core of a fiber) are sensitive to local temperature changes. Since these fibers are silica-based they are easily affected by localized changes in temperature, which results in changes to both the grating spacing and the wavelength reflectivity. We exploit the shift in wavelength reflectivity to measure the change in the local temperature. Note that the Bragg region (sensing area) is some distance away from where the temperature is being measured. This is done so that we can measure temperatures that are much higher than the damage threshold of the fiber. We do this by affixing the fiber with the Bragg sensor to a material with a well-known coefficient of thermal expansion, and model the heat gradient from the region of interest to the actual sensor. The research described in this paper will culminate in a working device as well as be the second portion of a publication pending submission to Optics Letters.

Lyons, Donald R.↗