Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor fabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Multiple-Cantilever Torque Sensor

Sensitivity to spurious loads small. High stiffness, high resolution, and ease of fabrication among features of specially designed torque sensor. Device flexible and sensitive to torque about its cylindrical axis and stiff enough to be insensitive to bending about any perpendicular axis. Measures and transmits torque between driving and driven plates.

Lurie, Boris J.↗

Enhanced temperature sensing based on sub-threshold nonlinear spectra of one-dimensional photonic crystal with a Kerr defect layer

A new method to achieve highly sensitive temperature sensing is proposed based on the nonlinear spectral properties of a one-dimensional photonic crystal (1DPC) composed of temperature-sensitive materials with a Kerr defect layer. The sensitivity can be two orders of magnitude higher than that of the corresponding linear 1DPC structure. The sensitivity and measuring range can be precisely tuned. These properties favor the fabrication of a versatile temperature sensor with switchable fine and coarse tuning functions. This principle of nonlinear temperature sensing can also be extended to other kinds of spectrum-based sensors to obtain higher performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Room Temperature ppb Level Chlorine Gas Sensor Based on Copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine Films

Spin coating technique has been used to fabricate room temperature chlorine gas sensor based on copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine (CuPc(OBu){sub 8}) films. Gas sensor shows a response of 185% to few parts per billion level of Cl{sub 2} gas with response time of 9.5 minutes at room temperature. The interactions between sensor and analytes followed first order kinetics with rate constant 0.01{<=}k{<=}0.02. The chemiresistive sensor showed very good stability at room temperature over a long period of time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffractive Optic Fluid Shear Stress Sensor

Light scattering off particles flowing through a two-slit inteference pattern can be used to measure the shear stress of the fluid. We have designed and fabricated a miniature diffractive optic sensor based on this principle.

fluid shear stress micro sensor non-invasive senso↗

Diffractive Optic Fluid Shear Stress Sensor

Light scattering off particles flowing through a two-slit interference pattern can be used to measure the shear stress of the fluid. We have designed and fabricated a miniature diffractive optic sensor based on this principle.

optics↗

Research study of pressure instrumentation

To obtain a more vibration resistant pressure sensor for use on the Space Shuttle Main Engine, a proximity probe based, diaphragm type pressure sensor breadboard was developed. A fiber optic proximity probe was selected as the sensor. In combination with existing electronics, a thermal stability evaluation of the entire probe system was made. Based upon the results, a breadboard design of the pressure sensor and electronics was made and fabricated. A brief series of functional experiments was made with the breadboard to calibrate, thermally compensate, and linearize its response. In these experiments, the performance obtained in the temperature range of -320 F (liquid N2) to +200 F was comparable to that of the strain gage based sensor presently in use on the engine. In tests at NASA-Marshall Space Flight Center (MSFC), after some time at or near liquid nitrogen temperatures, the sensor output varied over the entire output range. These large spurious signals were attributed to condensation of air in the sensing gap. In the next phase of development of this sensor, an evaluation of fabrication techniques toward greater thermal and mechanical stability of the fiber probe assembly must be made. In addition to this, a positive optics to metal seal must be developed to withstand the pressure that would result from a diaphragm failure.

Hoogenboom, L.↗

In situ growth of copper nanocrystals from carbonaceous microspheres with electrochemical glucose sensing properties

Graphical abstract: In situ growth of copper nanoparticles from hydrothermal copper-containing carbonaceous microspheres was induced by annealing or electron beam irradiation. Obtained micro-nano carbon/copper composite microspheres show electrochemical glucose sensing properties. - Highlights: • We synthesized carbonaceous microspheres containing non-nanoparicle copper species through a hydrothermal route. • By annealing or electron beam irradiation, copper nanoparticles would form from the carbonaceous microspheres in situ. • By controlling the annealing temperature, particle size of copper could be controlled in the range of 50–500 nm. • The annealed carbon/copper hierarchical composite microspheres were used to fabricate an electrochemical glucose sensor. - Abstract: In situ growth of copper nanocrystals from carbon/copper microspheres was observed in a well-controlled annealing or an electron beam irradiation process. Carbonaceous microspheres containing copper species with a smooth appearance were yielded by a hydrothermal synthesis using copper nitrate and ascorbic acid as reactants. When annealing the carbonaceous microspheres under inert atmosphere, copper nanoparticles were formed on carbon microspheres and the copper particle sizes can be increased to a range of 50–500 nm by altering the heating temperature. Similarly, in situ formation of copper nanocrystals from these carbonaceous microspheres was observed on the hydrothermal product carbonaceous microspheres with electron beam irradiation in a vacuum transmission electron microscopy chamber. The carbon/copper composite microspheres obtained through annealing were used to modify a glassy carbon electrode and tested as an electrochemical glucose sensor.

36 MATERIALS SCIENCE↗

The synthesis and electrical transport properties of carbon/Cr 2 GaC MAX phase composite microwires

While MAX phases offer an exotic combination of ceramic and metallic properties, rendering them a unique class of materials, their applications remain virtually hypothetical. To overcome this shortcoming, a sol–gel based route is introduced that allows access to microwires in the range of tens of micrometers. Thorough structural characterization through XRD, SEM, EDS, and AFM demonstrates a successful synthesis of carbonaceous Cr2GaC wires, and advanced low temperature electronic transport measurements revealed resistivity behavior dominated by amorphous carbon. Here, the tunability of electronic behavior of the obtained microwires is shown by a halide post-synthesis treatment, allowing purposeful engineering of the microwires’ electrical conductivity. Raman studies revealed the polyanionic nature of the intercalated halides and a slow decrease in halide concentration was concluded from time-dependent conductivity measurements. Based on these findings, the process is considered a viable candidate for fabricating chemiresistive halogen gas sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Dose Gamma Radiation Monitoring Through TiO{sub 2} Doped Lead Phthalocyanine (Pb-Pc) Based Schottky Device

The concept of Organic thin film based solid-state dosimeters is relatively new and more effective. The organic conductor based solid-state dosimeter provides a mean for low cost, ease to fabricate and sensitive radiation sensor which can be employed as pocket dosimeter for army personals getting exposed to nuclear radiation while working in the radioactive environment This concept is being utilized here for monitoring the effect of nuclear radiation on our organic material based sandwiched devices. In the present communication, lead Phthalocyanine (PbPc) doped with TiO{sub 2} (5% by weight) is developed into the form of thin film structure. The developed ITO/PbPc: TiO{sub 2}/Ag Schottky device structure was characterized in terms of change in its electrical and optical properties before and after exposure to radiation Exposure to radiation imparts an accelerated decrease in forward bias current and capacitance characteristics reveal a linear relationship between dose v/s current behavior which supports its suitability as pocket dosimeter for the dose ranging from 50 mR to 800 mR.

36 MATERIALS SCIENCE↗

Study of optical and structural properties of CdSe quantum dot embedded in PVA polymer matrix

To enhance the properties and applicability of devices it is essential to incorporate semiconductor nanoparticles into polymer matrix. This introduces a new branch of science which includes device fabrications such as gas sensors, nonlinear optics, catalysis etc. Herein, we have synthesized CdSe/PVA nanocomposite (NC) material using wet chemical synthesis technique. The XRD studies revealed the formation of crystalline structure of CdSe nanoparticles (NP’s) and PVA NC’s with an average size of 100 nm and 5 nm respectively. Energy band gap is determined using UV-VIS Spectroscopy. A red shift in the absorption edge of CdSe/PVA NC is observed with respect to CdSe Np’s, The photoluminescence spectra also show red shift for CdSe/PVA NC as compared to CdSe NP’s Thus the use of CdSe/PVA for solar cell application would be more preferable than CdSe NP’s.

36 MATERIALS SCIENCE↗

BICEP2. II. Experiment and three-year data set

We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(ℓ = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μK√s. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg{sup 2} within a 1000 deg{sup 2} field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.

79 ASTRONOMY AND ASTROPHYSICS↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration and Validation of a Portable Raman Sensor for In-Situ Detection and Monitoring of Perchlorate (ClO 4 - )

Costs for environmental analysis and monitoring are increasing at a rapid rate and represent a significant percentage of the total and future remedial expenses at many U.S. Department of Defense (DoD) contaminated sites. It has been reported that about 30 to 40% of the remediation budget is usually spent on long-term monitoring (LTM), of which a large percentage represents laboratory analytical costs. Energetics such as perchlorate (ClO 4 - ) are among the most frequently detected contaminants in groundwater and surface water at or near military installations due to their persistence and mobility. Currently, the standard protocol entails collecting samples in the field, packaging them, and shipping them overnight to a designated laboratory for analysis. This process requires significant sample preparation and handling, and analytical results may not be available for several days to weeks. In this project, we developed and demonstrated a portable Raman sensor based on surface enhanced Raman scattering (SERS) technology to detect ClO 4 - in contaminated water. We summarize major accomplishments as follows: • A SERS sensor based on elevated gold (Au) nano-ellipse dimer architectures was designed and developed for ClO 4 - with a detection limit of ~10 -6 M (or 100 μg/L); The performance of these sensors was evaluated and optimized through variation of their geometric characteristics (i.e., dimer aspect ratio, dimer separation, etc.). • Large-scale commercial production of SERS substrate sensors via nanoimprinting by Nanova Inc. and Nanoimprint lithography (NIL) technology was successfully demonstrated. This is a substantial step forward toward the commercialization of the SERS sensors and may potentially lead to significantly reduced fabrication costs of SERS substrates. • Commercially produced SERS sensors were demonstrated to detect ClO 4 - at levels above 10 -6 M using a portable Raman analyzer. The performance of the commercial SERS sensors for ClO 4 - detection in the presence and absence of interferences was determined for a series of standard solutions. Sulfate (SO 4 2- ) was found to exhibit the greatest interference for the anions tested, which included Cl-, NO 3 - , and SO 4 2- . • Field demonstration of the portable Raman sensor with commercially produced SERS substrates was completed at two Department of Defense (DoD) sites; twice at the Indian Head Naval Surface Warfare Center, Indian Head, MD, and once at Redstone Arsenal, Huntsville, AL. Multiple wells were sampled at both DoD sites, where a standard addition method was employed using the sensor to determine the ClO 4 - 4 - and possibly other energetics that are both important for environmental monitoring and of interest for national security. However, we point out that SERS technology is also prone to interferences due to its sensitivity and responses to other ionic species, such as NO 3 - , SO 4 2- , and dissolved organics or co-contaminants present in the groundwater, which could potentially mask the SERS signal of the target analyte (i.e., ClO 4 - ). As such, SERS analysis was subject to significant variations (e.g., ±20% or more), and its detection limit for ClO 4 - -8 M) and was substantially higher than what we anticipated from laboratory studies. However, despite these complications, the portable Raman sensor developed in this project could be used as a rapid screening tool for ClO 4 - at concentrations above 10 -6 M. Future studies are warranted to further develop the technology and to optimize its performance, and eventually to bring the technology to the market. With additional development and demonstration, the sensor has the potential to reduce analytical costs by eliminating shipping and typical costs associated with laboratory analysis. A cost savings of 30–45% may be realized during a typical sampling event and, more importantly, the technology could allow rapid turn-around of information to decision makers for site characterization and remediation.

47 OTHER INSTRUMENTATION↗

Active Inner Veto for Improved SuperCDMS SNOLAB Dark Matter Search Sensitivity. Final Report

The goal of this project was to develop and study a new geometry of cryogenic detector that could act as an active veto surrounding a smaller, inner cryogenic detector. This drastically reduces the background event rates, enabling more effective rare event searches. An annular germanium detector was fabricated with athermal phonon sensors and successfully tested. A threshold of better than 10keV was desired; 4keV was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Applied Spectra, Inc.

Groundwater resources can be contaminated by a variety of surface and subsurface sources. For instance, metals can be leached from surface dumps (e.g. landfills, etc.) and reach groundwater supplies by percolation though the soil. Additionally, subsurface activities such as geologic carbon storage (GCS) could result in contamination. In the event of CO2 leakage, freshwater above the injection site can potentially be contaminated with metals either originating from the formation fluids or leached from formation rocks by CO2 acidification. Detection of these contaminating metals is critical for maintaining water safety and providing an early warning of a containment breach. Therefore, a compact, subsurface capable laser induced breakdown spectroscopy (LIBS) based sensor has been developed for groundwater quality monitoring applications. LIBS sensor technology has been advanced from benchtop feasibility studies to a custom fabricated, watertight prototype. The all optical sensor head is built using a low cost passively Q-switched (PQSW) laser, which is fiber coupled to a control unit containing the pump laser and a gated spectrometer. Separating the LIBS excitation laser from the pump and spectrometer allows the expensive and fragile components to remain in a safe, central location while only the sensor head needs to enter the subsurface. Testing of the prototype sensors show Limits of Detection (LODs) comparable to benchtop, actively Q-switched systems and has verified that the fiber coupling and triggering schemes perform as desired.

McIntyre, Dustin↗

Accelerometer Modeling in the State-Space

Generically, accelerometers are sensors that measure the accelerating force applied to an object. Their operation is based on a simple mechanical system and D’Alembert’s force principle along with Newton’s laws of motion. This device is typically mounted to the body of the test object under investigation that is subjected to an accelerating force. The displacement of the seismic or “proof” mass due to the acceleration is sensed by an embedded component from which the acceleration is determined. Interestingly enough, the resulting the resulting mathematical relations governing the dynamical motion is based on the underlying physics, sensor materials, geometry and fabrication. Mathematically, the various designs satisfy the underlying Newtonian equations of motion, but their type and performance differ significantly.

42 ENGINEERING↗

Development of InSb charge-coupled infrared imaging devices: Linear imager

The following results were accomplished in the development of charge coupled infrared imaging devices: (1) a four-phase overlapping gate with 9 transfers (2-bits) and 1.0-mil gate lengths was successfully operated, (2) the measured transfer efficiency of 0.975 for this device is in excellent agreement with predictions for the reduced gate length device, (3) mask revisions of the channel stop metal on the 8582 mask have been carried out with the result being a large increase in the dc yield of the tested devices, (4) partial optical sensitivity to chopped blackbody radiation was observed for an 8582 9-bit imager, (5) analytical consideration of the modulation transfer function degradation caused by transfer inefficiency in the CCD registers was presented, and (6) for larger array lengths or for the insertion of isolated bits between sensors, improvements in InSb fabrication technology with corresponding decrease in the interface state density are required.

Phillips, J. D.↗

A high frequency silicon pressure sensor

Theoretical and design considerations as well as fabrication and experimental work involved in the development of high-frequency silicon pressure sensors with an ultra-small diaphragm are discussed. A sensor is presented with a rectangular diaphragm of 0.0127 cm x 0.0254 cm x 1.06 micron; the sensor has a natural frequency of 625 kHz and a sensitivity of 0.82 mv/v-psi. High-frequency results from shock tube testing and low-frequency (less than 50 kHz) comparison with microphones are given.

Kahng, S. K.↗