Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Scintillating glass for precision calorimetry in nuclear physics

High-performance scintillator materials are needed for particle identification and measurements of energy and momentum of electromagnetic particles in modern nuclear physics experiments. As an example, the US Electron-Ion Collider, a unique collider with diverse physics topics, requires electromagnetic calorimetry enabling high-quality electron identification and detection in the momentum range of 0.3 to tens of GeV. The highest resolution in electromagnetic calorimeters can be provided by homogeneous materials, e.g., lead tungstate crystals. Inorganic glass scintillators have been investigated as an attractive and cost-effective alternative to crystals, that is also easier and faster to manufacture in mass production. In this paper, we discuss progress in the fabrication and characterization of recent scintillating glass samples on both test bench and beam tests. Further, the results are well-reproduced by simulation and are discussed in the context of the Electron-Ion Collider experimental requirements and bench-marked against lead tungstate crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature Quenching in LAB based liquid scintillator

The effect of temperature changes on the light output of LAB based liquid scintillator is investigated in a range from –5 C to 30 °C with a-particles and electrons in a small scale setup. Two PMTs observe the scintillator liquid inside a cylindrically shaped aluminum cuvette that is heated or cooled and the temperature dependent PMT sensitivity is monitored and corrected. The a-emitting isotopes in dissolved radon gas and in natural Samarium (bound to a LAB solution) excite the liquid scintillator mixtures and changes in light output with temperature variation are observed by fitting light output spectra. Furthermore, also changes in light output by compton electrons, which are generated from external calibration g-ray sources, is analysed with varying temperature. Assuming a linear behaviour, a combined negative temperature coefficient of (–0:29 0:01) % /°C is found. Considering hints for a particle type dependency, electrons show (–0:17 0:02) % /°C, whereas the temperature dependency seems stronger for a-particles, with (–0:35 0:03) % /°C. Furthermore, due to a high sampling rate, a pulse shape analysis can be performed and shows an enhanced slow decay component at lower temperatures, pointing to reduced non-radiative triplet state de-excitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intuitive model for the scintillations of a partially coherent beam

We developed an intuitive model for the scintillation index of a partially coherent beam in which essentially the only critical parameter is the properly defined Fresnel number equal to the ratio of the “working” aperture area to the area of the Fresnel zone. The model transpired from and is supported by numerical simulations using Rytov method for weak fluctuations regime and Tatarskii turbulence spectrum with inner scale. The ratio of the scintillation index of a partially coherent beam to that of a plane wave displays a characteristic minimum, the magnitude of which and its distance from the transmitter are easily explained using the intuitive model. Furthermore, a theoretical asymptotic is found for the scintillation index of a source with decreasing coherence at this minimum.

97 MATHEMATICS AND COMPUTING↗

Advanced plastic scintillators for fast neutron discrimination

The present work addresses the need for solid-state, fast neutron discriminating scintillators that possess higher light yields and faster decay kinetics than existing organic scintillators. These respective attributes are of critical importance for improving the gamma-rejection capabilities and increasing the neutron discrimination performance under high-rate conditions. Two key applications that will benefit from these improvements include large-volume passive detection scenarios as well as active interrogation search for special nuclear materials. Molecular design principles were employed throughout this work, resulting in synthetically tailored materials that possess the targeted scintillation properties.

36 MATERIALS SCIENCE↗

LiCaAIF 6 :Eu Scintillator Family Neutron Detection (Final Report)

The proposed work was based on a learning cycle format with three parts, (1) Modeling, (2) Growth, (3) Characterization, to investigate the family of colquiriite scintillators and various activating dopants as efficiently and effectively as possible. Under this research methodology, each of these functions would feed information to the next. Each iteration around the cycle was expected to improve results and provide clues to the best path forward for the next iteration. However, it was realized that this research model is not robust and unable to handle setbacks at any one of the functions. Unfortunately, the project suffered setbacks in the “Growth” function and progress in the other functions was severely restricted. Of course, numerous alternative paths were trialed within the growth function to enable progress, but these required addition time and resources which in the end only provided limited progress. After reviewing the project as a whole, it can be concluded that the research model used was indeed too fragile for this sort of research and a more robust plan should be utilized in the future. As a whole though, significant progress was made toward understanding the barriers toward realizing the benefits of this family of scintillators through modeling. Various paths forward were postulated, but limited growth and synthesis capabilities prevented experimental validation. Experimentally, it was found that the synthesis and growth of colquiriite scintillators requires special considerations for its thermodynamic and chemical properties. These were overcome in the end and a new, lower cost growth method realized, but too late to have a significant impact in validating modeling hypotheses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the intrinsic scintillator Cs 2 LiCeCl 6

In this work, we report on the scintillation properties of the intrinsic scintillator Cs 2 LiCeCl 6 (CLCC), which is potentially useful for dual gamma-ray and neutron detection. CLCC is from the elpasolite family with a cubic structure. We grew the crystals at BNL by the vertical Bridgman growth technique. The luminescence spectrum of CLCC showed a doublet with peak maxima at 384 nm and 402 nm. The light yield of CLCC was approximately 20,000 photons/MeV, and the energy resolution was about 6% for 662-keV gamma radiation. A scintillation decay of ~81% of the total light was observed to be ~ 90 nanoseconds.

36 MATERIALS SCIENCE↗

A Scintillating Xenon Bubble Chamber for Dark Matter Detection. Final Report

This report describes the progress in the search for particle dark matter achieved under DOE award DE-SC0012161, as well as the invention of a new dark matter and neutrino detection technique. Work supported by this award follows in three distinct thrusts: (1) the successful completion of the Generation-1 Direct Detection experiment PICO-60, which set the world-leading limit on the spin-dependent coupling of dark matter to protons and achieved a precise understanding of the response of bubble chambers to nuclear-recoil signals and electron-recoil backgrounds; (2) the construction of the Generation-2 Direct Detection experiment LZ, which will soon be the world's most sensitive dark matter detector; and (3) the demonstration of the first scintillating bubble chamber. The development of a scintillating liquid noble bubble chamber was the primary goal of the proposed work, with the aim of combining the excellent background rejection of a PICO-style bubble chamber with the event-by-event energy resolution of a liquid-noble detector such as LZ. This work produced the first ever observation of coincident scintillation and bubble nucleation by a nuclear recoil in a superheated fluid and also revealed an unexpected benefit to the use of noble liquids in a bubble chamber, namely the ability to increase the degree of superheat by an order of magnitude beyond that achievable in PICO-style detectors while maintaining PICO's world-leading background rejection. This discovery has led to new projects in the US and Canada, developing noble liquid bubble chambers both as detectors for low-mass dark matter and as detectors of coherent elastic neutrino-nucleus scattering (CEvNS) by neutrinos produced at nuclear reactors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

(U) Segmented Scintillator Pitch, Thickness, and Septa Material Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy X-Ray Radiography

Scintillator design is an important aspect in constructing a radiographic facility in order to collect the most robust data possible. For the proposed Enhanced Capabilities for Sub-critical Experiment (ECSE) facility in Nevada, we explored a permutation of 13 segmented scintillator designs in order to understand the best performance and trade offs for each design. We calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(0)) for each scintillator design in order to compare performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of Water-Based Liquid Scintillator in ANNIE

ANNIE is a 26-ton water Cherenkov detector at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This poster discusses the deployment of a WbLS filled vessel SANDI in ANNIE and the detection of both Cherenkov light and scintillation from the WbLS.

43 PARTICLE ACCELERATORS↗

Technology Transfer from Fermi Research Alliance to Itasca Plastics for the purpose of Commercializing Scintillator Material

Researchers at the Fermi National Accelerator Laboratory (Fermilab) developed extruded plastic scintillator in the late 1990s, which was first used in the D-Zero experiment. Extruded plastic scintillator is currently produced at Fermilab and is used in particle detectors worldwide. The purpose of this CRADA is to transfer the knowledge related to the Fermilab extrusion process to Itasca Plastics, Inc. (Itasca Plastics). Much of this knowledge is contained in documentation that is in the public domain, although it is distributed over several communications (papers, conference records, etc.) and over several years. Under this CRADA Fermilab will assemble the information, provide it to Itasca Plastics and provide limited consulting to complete the knowledge transfer. If the transfer is successful, Itasca Plastics will be able to establish a U.S. commercial manufacturing capability for extruded scintillator material that can be used for high energy physics and commercial applications.

36 MATERIALS SCIENCE↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Analysis of scintillation light dependence on liquid Argon purity

Previous studies have investigated the correlation between impurity concentrations in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield. These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N_2),can influence LAr scintillation properties without necessarily affecting electron lifetime. Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetimes in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS experiment consists of two cryostats that have shown some discrepancies in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats.

Saia, Clara [Catania Astrophys. Observ.]↗

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

Scintillator Manufacture

This paper will be a literature review of composite scintillators, and their applications in neutron detection. Due to the shortage of 3 He, the traditional medium for neutron detection, new materials need to be explored for this purpose. Composite scintillating particle materials can serve as a solution to replace 3 He, offering faster response times, and all-solid-state form factors for diversified applications in the field. This project will include manufacturing Europium (Eu) and Sodium (Na) doped LiCaAlF 6 (LiCAF) scintillating particles for neutron detection.

36 MATERIALS SCIENCE↗

Fast-, Light-Cured Scintillating Plastic for 3D-Printing Applications

Additive manufacturing techniques enable a wide range of possibilities for novel radiation detectors spanning simple to highly complex geometries, multi-material composites, and metamaterials that are either impossible or cost prohibitive to produce using conventional methods. The present work identifies a set of promising formulations of photocurable scintillator resins capable of neutron-gamma pulse shape discrimination (PSD) to support the additive manufacturing of fast neutron detectors. The development of these resins utilizes a step-by-step, trial-and-error approach to identify different monomer and cross-linker combinations that meet the requirements for 3D printing followed by a 2-level factorial parameter study to optimize the radiation detection performance, including light yield, PSD, optical clarity, and hardness. The formulations resulted in hard, clear, PSD-capable plastic scintillators that were cured solid within 10 s using 405 nm light. The best-performing scintillator produced a light yield 83% of EJ-276 and a PSD figure of merit equaling 1.28 at 450–550 keVee.

Frandsen, Brian G. (ORCID:0000000319964320)↗

Dedicated $\Delta E$--$E$ Detector System for Searching Long-lived Heaviest Nuclei Deposited in Scintillators

We present a dedicated experimental setup which is currently used to search for long lived super heavy elements (SHE) implanted in catcher scintillators which were irradiated by reaction products of 197Au (7.5 A.MeV) projectile and 232Th target collisions during our experiment performed at Cyclotrone Institute, Texas A&M University in 2015. The built-in novel measuring apparatus consists of ΔE-E detector pairs which are able to register α or spontaneous fission (SF) decays of heavy reaction products deposited in the scintillators. Their unique feature is that the examined scintillators are at the same time ΔE part of each of ΔE-E detector while E part is a silicon detector. Our apparatus is dedicated to search for SHEs which have a lifetime of a year till tens of years. Results of commissioning tests of our setup are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling Time Dispersion Due to Optical Path Length Differences in Scintillation Detectors

In this paper, we characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal with 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Finally, estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗