Plasma-Assisted Pre-Chamber Ignition System for Highly Dilute Stoichiometric Heavy-Duty Natural Gas Engines (Final Technical Report)

This project explored advanced ignition technologies to significantly enhance efficiency and reduce operating costs for heavy-duty natural gas engines operating at stoichiometric conditions, while meeting ultra-low NOx emission standards. The main goal was to develop and validate a plasma-assisted pre-chamber ignition system that could deliver at least a 2% increase in brake thermal efficiency (BTE) and a 4% decrease in total cost of ownership (TCO) compared to a typical multi-cylinder engine with three-way catalyst aftertreatment, ensuring compatibility with the expected 2027 EPA/CARB regulations. In the first half of the project, the research team concentrated on developing and testing plasma-assisted pre-chamber ignition using nanosecond pulsed discharges. Extensive experiments were conducted in an optically accessible rapid-compression and expansion machine, a constant-volume chamber, and an optical single-cylinder engine. Experiments were coupled with CFD simulations. The work produced unique insights into pre-chamber flame formation, jet ignition, dilution effects, and flame quenching at pressures, temperatures, and dilution levels relevant to engines. Although plasma-assisted ignition showed promise in controlled lab settings, the research also identified fundamental and practical challenges when applying this technology to real engine conditions. Midway through the project, a crucial pivot was made, guided by three key findings. First, the power electronics required for nanosecond plasma discharges were found to be too costly for commercial use, undermining the project’s cost-of-ownership goals. Second, nanosecond plasma ignition was highly sensitive to turbulent flow in the pre-chamber, resulting in lower ignition reliability than traditional spark under engine-like conditions. Third, achieving a truly diffuse low-temperature plasma at high pressures near top dead center was not possible, reducing the anticipated chemical enhancement benefits. These results collectively suggested that continuing with plasma-assisted ignition was unlikely to meet both efficiency and cost objectives. In response, the project shifted focus to a more realistic approach: enhancing traditional spark-based pre-chamber ignition with significantly less spark energy. Using insights gained earlier in the project, the team redesigned the pre-chamber to maintain high dilution tolerance and quick combustion, even with lower ignition energy. Testing confirmed that with optimized pre-chamber design and combustion timing, a lower-energy spark could reliably ignite highly diluted stoichiometric mixtures, reduce burn time, and boost thermal efficiency. Final engine testing and techno-economic analysis verified that this revised approach successfully achieved the project goals. The optimized pre-chamber ignition system provided over a 2% increase in calculated brake thermal efficiency compared to the baseline engine. Notably, the lower ignition energy and simplified hardware reduced component stress, extended maintenance intervals, and lowered the total cost of ownership. When used with stoichiometric operation and traditional three-way aftertreatment, the system remained compatible with near-zero NOx emissions targets without increasing cost or complexity in the emissions control system. In summary, although the project deviated from its initial plasma-assisted ignition idea, the work produced a more practical and commercially viable solution. The results show that precisely optimized, low-energy pre-chamber spark ignition can significantly improve efficiency and reduce overall ownership costs for heavy-duty natural gas engines. This directly aligns with DOE goals for cleaner, more efficient, and cost-effective transportation technologies.

03 NATURAL GAS↗

Parametric Evaluation of RDE Inlet Performance using a Reduced-Order Model

This paper presents the results of a parametric study on the effects of inlet restriction, along with a number of other controlling parameters, using a previously developed reduced-order RDE inlet model. The results of this study will be used to inform subsequent high-fidelity CFD simulations and/or selection of experimental operating conditions which may be conducive to maximizing performance.

Bedick, Clinton↗

Design-Space Exploration for Inverse-Design of Wind Turbine Blades Using Data-Driven Methods

The state-of-the-practice aerodynamic design methods for wind turbine blades is typically based on Blade-Element Momentum (BEM) theory using a pre-designed frozen family of airfoils. The airfoils are themselves typically designed using panel methods. The design of the next-generation of large flexible rotors will need to capture the non-linear aerodynamics and three-dimensional flow to reduce the levelized cost of wind energy. Data-driven methods for aerodynamic design using data generated by computational fluid dynamics offer an attractive alternative to BEM-based methods that captures the non-linear aerodynamics of the component airfoils as well as the root and tip sections. In this work, we develop and demonstrate a framework to "smartly" explore the relevant design space in combination with an appropriate automated CFD pipeline to evaluate the aerodynamics of each design. The design-space exploration framework uses appropriate perturbations to the airfoil shape and induction profile from a baseline shape in combination with the inverse-design using BEM. The resulting designs are evaluated using an automated CFD pipeline using the in-house CFD solver framework "Mercury". We perform verification and validation to establish the capability of the Mercury framework to predict the aerodynamic performance of wind turbines. The CFD simulation of the perturbed blade shapes are optimized to restart from the converged baseline simulation to reduce the computational time. Finally, we demonstrate the design-space exploration technique for the design of the outboard section and the full rotor using perturbations to the shape and operating conditions of the NREL 5-MW turbine.

aerodynamic design methods↗

Comparison of realistic and idealized breathing patterns in computational models of airflow and vapor dosimetry in the rodent upper respiratory tract

Abstract Context: Computational fluid dynamics (CFD) simulations of airflows coupled with physiologically based pharmacokinetic (PBPK) modeling of respiratory tissue doses of airborne materials have traditionally used either steady-state inhalation or a sinusoidal approximation of the breathing cycle for airflow simulations despite their differences from normal breathing patterns. Objective: Evaluate the impact of realistic breathing patterns, including sniffing, on predicted nasal tissue concentrations of a reactive vapor that targets the nose in rats as a case study. Materials and methods: Whole-body plethysmography measurements from a free-breathing rat were used to produce profiles of normal breathing, sniffing and combinations of both as flow inputs to CFD/PBPK simulations of acetaldehyde exposure. Results: For the normal measured ventilation profile, modest reductions in time- and tissue depth-dependent areas under the curve (AUC) acetaldehyde concentrations were predicted in the wet squamous, respiratory and transitional epithelium along the main airflow path, while corresponding increases were predicted in the olfactory epithelium, especially the most distal regions of the ethmoid turbinates, versus the idealized profile. The higher amplitude/frequency sniffing profile produced greater AUC increases over the idealized profile in the olfactory epithelium, especially in the posterior region. Conclusions: The differences in tissue AUCs at known lesion-forming regions for acetaldehyde between normal and idealized profiles were minimal, suggesting that sinusoidal profiles may be used for this chemical and exposure concentration. However, depending upon the chemical, exposure system and concentration and the time spent sniffing, the use of realistic breathing profiles, including sniffing, could become an important modulator for local tissue dose predictions.

dosimetry↗

Outflow Boundary Conditions for Turbine-Integrated Rotating Detonation Combustors

This study examines outflow boundary conditions (BCs) in computational fluid dynamics (CFD) simulations of a transition duct with and without guide vanes that converts supersonic flow exiting a rotating detonation combustor (RDC) to subsonic flow to drive a turbine. Since the flow exiting the transition duct has swirling shock waves with significant spatial and temporal variations in pressure, temperature, and Mach number, imposing proper BCs poses a challenge. To ensure all swirling shock waves exit the transition duct without creating non-physical reflected waves at its outlet, this study examined three outflow BCs: (1) the average pressure imposed at the duct’s outlet, (2) a nonreflecting BC (NRBC) with a specified average pressure imposed at the duct’s outlet, (3) the average pressure imposed at the outlet of an extension duct made up of a buffer layer and a sponge layer. This study is based on the three-dimensional, unsteady density-weighted-ensemble-averaged continuity, Navier–Stokes, and energy equations for a thermally perfect gas closed by the realizable k–ε model and “enhanced” wall functions. The results obtained show that imposing an average pressure at the transition duct’s outlet produces spurious waves that degrade the physical meaningfulness of the solution. When the NRBC was applied, swirling shock waves exited the duct’s outlet without creating spurious waves. However, its usage requires the gas to be thermally, as well as calorically, perfect, which this study shows could be a concern. By imposing the average pressure at the outlet of an extension duct, the gas does not need to be calorically perfect. The results obtained show the effects of the sponge layer’s length and coarsening ratio on damping nonuniformities in non-physical reflected waves to ensure the flow exiting the transition duct’s outlet can do so as if there are no boundaries present and has the desired average pressure—even though the BC is applied at the extension duct’s outlet.

gas turbines↗

Measurements and Prediction of Ash Deposition in a Cyclone-Fired Boiler Operating under Variable Load Conditions

Measurements of ash deposition rates were made between the secondary superheater and reheater sections of a 450 MW cyclone-fired lignite boiler as the operational load varied from 33 to 100%. Significant reductions in deposition rates with a decrease in operational load were observed. To uncover the causative mechanisms behind these observations, operational data from the power plant were used to carry out computational fluid dynamic (CFD) simulations of the boiler. After ascertaining that the gas temperatures and velocities at various sections within the boiler were being represented adequately, decoupled simulations of the ash deposition process on the deposit probe were carried out using a finely resolved boundary layer mesh. Fly ash particle size distribution (PSD) and its concentration for the decoupled calculations were determined from stand-alone cyclone barrel simulations. The ash partitioning (mass %) between the fly ash and slag was found to be ~50:50, which was in line with previous field observations, and it did not vary significantly across different cyclone loads. The predicted PSD of the deposit ash was concentrated in the size range 10–30 microns, which was in agreement with cross-sectional images of the deposit obtained from the measurements. At lower loads, sharp variations in the deposition rates were predicted in the gas temperature range 950–1150 K. The particle kinetic energy—particle viscosity-based capture methodology utilized in this study in conjunction with appropriate ash compositions, ash viscosity models and gas temperature estimates can help estimate slagging propensities at different loads reasonably well in these systems.

Krishnamoorthy, Gautham (ORCID:0000000255205092)↗

Ducted Fuel Injection Provides Consistently Lower Soot Emissions in Sweep to Full-Load Conditions

Earlier studies have proven how ducted fuel injection (DFI) substantially reduces soot for low- and mid-load conditions in heavy-duty engines, without significant adverse effects on other emissions. Nevertheless, no comprehensive DFI study exists showing soot reductions at high- and full-load conditions. This study investigated DFI in a single-cylinder, 1.7-L, optical engine from low- to full-load conditions with a low-net-carbon fuel consisting of 80% renewable diesel and 20% biodiesel. Over the tested load range, DFI reduced engine-out soot by 38.1–63.1% compared to conventional diesel combustion (CDC). This soot reduction occurred without significant detrimental effects on other emission types. Thus, DFI reduced the severity of the soot–NO x tradeoff at all tested conditions. While DFI delivered considerable soot reductions in thepresent study, previous DFI studies at low- and mid-load conditions delivered larger soot reductions (>90%) compared to CDC operation at the same conditions. Therefore, the DFI configuration used here has been deemed nonoptimal (in terms of parameters such as the injector-spray and piston geometries), and several improvements are recommended for future studies with high-load DFI. Further, these improvements include employing better spray-duct alignment, a deeper piston bowl with a smaller injector umbrella angle, and a fuel injector that opens and closes faster. The study also suggests future research to make DFI ready for commercialization, such as metal-engine tests to ensure desirable DFI performance over an engine’s complete speed/load map. Overall, this study supports the continued development and commercialization of DFI to meet upcoming emissions regulations for heavy-duty vehicles. Specifically, multicylinder engine experiments and CFD simulations should be utilized to optimize the performance and clarify the full potential of DFI.

33 ADVANCED PROPULSION SYSTEMS↗

An Experimental and Numerical Study of Diesel Spray Impingement on a Flat Plate

Combustion systems with advanced injection strategies have been extensively studied, but there still exists a significant fundamental knowledge gap on fuel spray interactions with the piston surface and chamber walls. This paper is meant to provide detailed data on spray-wall impingement physics and support the spray-wall model development. The experimental work of spray-wall impingement with non-vaporizing spray characterization, was carried out in a high pressure-temperature constant-volume combustion vessel. The simultaneous Mie scattering of liquid spray and schlieren of liquid and vapor spray were carried out. Diesel fuel was injected at a pressure of 1500 bar into ambient gas at a density of 22.8 kg/m3 with isothermal conditions (fuel, ambient, and plate temperatures of 423 K). A Lagrangian-Eulerian modeling approach was employed to characterize the spray-gas and spray-wall interactions in the CONVERGE framework by means of a Reynolds-Averaged Navier-Stokes (RANS) formulation. A set of turbulence and spray break-up model constants was identified to properly match the aforementioned measurements of liquid penetration within their experimental confidence intervals. An accuracy study on varying the minimum mesh size was also performed to ensure the grid convergence of the numerical results. Experimentally validated computational fluid dynamics (CFD) simulations were then used to investigate the local spray characteristics in the vicinity of the wall with a particular focus on Sauter Mean Diameter (SMD) and Reynolds and Weber numbers. The analysis was performed by considering before- and after-impingement conditions in order to take in account the influence of the impinged wall on the spray morphology.

42 ENGINEERING↗

Evaluation of obstacle modelling approaches for resource assessment and small wind turbine siting: case study in the northern Netherlands

Abstract. Growth in adoption of distributed wind turbines for energy generation is significantly impacted by challenges associated with siting and accurate estimation of the wind resource. Small turbines, at hub heights of 40 m or less, are greatly impacted by terrestrial obstacles such as built structures and vegetation that can cause complex wake effects. While some progress in high-fidelity complex fluid dynamics (CFD) models has increased the potential accuracy for modelling the impacts of obstacles on turbulent wind flow, these models are too computationally expensive for practical siting and resource assessment applications. To understand the efficacy of available models in situ, this study evaluates classic and commonly used methods alongside new state-of-the-art lower-order models derived from CFD simulations and machine learning approaches. This evaluation is conducted using a subset of an extensive original dataset of measurements from more than 300 operational wind turbines in the northern Netherlands. The results show that data-driven methods (e.g. machine learning and statistical modelling) are most effective at predicting production at real sites with an average error in annual energy production of 2.5 %. When sufficient data may not be available de novo to support these data-driven approaches, models derived from high-fidelity simulations show promise and reliably outperform classic methods. On average these models have 6.3 %–11.5 % error compared with 26 % for classic methods and 27 % baseline error for reanalysis data without obstacle correction. While more performant on average, these methods are also sensitive to the quality of obstacle descriptions and reanalysis inputs.

17 WIND ENERGY↗

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY↗

Development of a %22solar patch%22 calculator to evaluate heliostat-field irradiance as a boundary condition in CFD models.

A rigorous computational fluid dynamics (CFD) approach to calculating temperature distributions, radiative and convective losses, and flow fields in a cavity receiver irradiated by a heliostat field is typically limited to the receiver domain alone for computational reasons. A CFD simulation cannot realistically yield a precise solution that includes the details within the vast domain of an entire heliostat field in addition to the detailed processes and features within a cavity receiver. Instead, the incoming field irradiance can be represented as a boundary condition on the receiver domain. This paper describes a program, the Solar Patch Calculator, written in Microsoft Excel VBA to characterize multiple beams emanating from a 'solar patch' located at the aperture of a cavity receiver, in order to represent the incoming irradiance from any field of heliostats as a boundary condition on the receiver domain. This program accounts for cosine losses; receiver location; heliostat reflectivity, areas and locations; field location; time of day and day of year. This paper also describes the implementation of the boundary conditions calculated by this program into a Discrete Ordinates radiation model using Ansys{reg_sign} FLUENT (www.fluent.com), and compares the results to experimental data and to results generated by the code DELSOL.

14 SOLAR ENERGY↗

Development of a %22Solar Patch%22 calculator to evaluate heliostat-field irradiance as a boundary condition in CFD models.

A rigorous computational fluid dynamics (CFD) approach to calculating temperature distributions, radiative and convective losses, and flow fields in a cavity receiver irradiated by a heliostat field is typically limited to the receiver domain alone for computational reasons. A CFD simulation cannot realistically yield a precise solution that includes the details within the vast domain of an entire heliostat field in addition to the detailed processes and features within a cavity receiver. Instead, the incoming field irradiance can be represented as a boundary condition on the receiver domain. This paper describes a program, the Solar Patch Calculator, written in Microsoft Excel VBA to characterize multiple beams emanating from a 'solar patch' located at the aperture of a cavity receiver, in order to represent the incoming irradiance from any field of heliostats as a boundary condition on the receiver domain. This program accounts for cosine losses; receiver location; heliostat reflectivity, areas and locations; field location; time of day and day of year. This paper also describes the implementation of the boundary conditions calculated by this program into a Discrete Ordinates radiation model using Ansys{reg_sign} FLUENT (www.fluent.com), and compares the results to experimental data and to results generated by the code DELSOL.

14 SOLAR ENERGY↗

Enhancing VHTR Passive Safety and Economy with Thermal Radiation Based Direct Reactor Auxiliary Cooling System

One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The decay heat first is transferred to the core barrel by conduction and radiation, and then to the reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface area). When the relative decay heat removal capability decreases, the peak fuel temperature increases, even close to the design limit. Annular core designs with inner graphite reflector can mitigate this effect; therefore can further increase the reactor power. Another way to increase the reactor power is to increase power density. However, the reactor power is also limited by the decay heat removal capability. Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environment side. For the reactor side, cooling pipes will be inserted into holes made in the outer or inner graphite reflector blocks. There will be gaps between these cooling pipes and their corresponding surrounding graphite surfaces. Graphite has an excellent heat conduction property. By taking advantage of this feature, we can have a volume-based method to remove decay heat. The scalability can be achieved, if needed, by employing more rows of cooling pipes to accommodate higher decay heat rates. Since heat can easily conduct through the graphite regions between the holes made for the cooling pipes, those cooling pipes located further away from the active core region can still be very effective in removing decay heat. By removing the limit on the decay heat removal capability due to the limited available surface area as in a RVACS, the reactor power and power density can be significantly increased, without losing the passive heat removal feature. This paper will introduce the concept of using DRACS to enhance VHTR passive safety and economics. Three design options will be discussed, depending on the cooling pipe locations. Analysis results from a lumped volume based model and CFD simulations will be presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stimuli Responsive/Rheoreversible Hydraulic Fracturing Fluids for Enhanced Geothermal Energy Production (Part II)

We have used an environmentally friendly and recyclable hydraulic fracturing fluid - diluted aqueous solutions of polyallylamine or PAA – for reservoir stimulation in Enhanced Geothermal System (EGS). This fluid undergoes a controlled and large volume expansion with a simultaneous increase in viscosity triggered by CO2 at EGS temperatures. We are presenting here the results of laboratory-scale hydraulic fracturing experiment using the fluid on small cylindrical rock cores (1.59 cm in diameter and 5.08 cm in length) from the Coso geothermal field in California. Rock samples consisted of Mesozoic diorite metamorphosed to greenschist facies. The experiments were conducted on 5 samples for realistic ranges of pressures (up to 275 bar) and temperatures (up to 210 °C) for both the rock samples and the injected fluid. After fracturing, cores were subjected to a CO2 leakage test, injection of KI solution, and X-ray microtomography (XMT) scanning to examine the formation and distribution of fractures. The design and conduct of these experiments will be presented and discussed in details. Based on the obtained XMT images, Computational Fluid Dynamics (CFD) simulations were then performed to visualize hydraulic fractures and compute the bulk permeability. OpenFOAM (OpenCFD Ltd., Reading, UK), was used to solve the steady state simulation. The flow predictions, based upon the laminar, 3-D, incompressible Navier-Stokes equations for fluid mass and momentum, show the remarkable stimulation of the permeability in the core samples and demonstrate the efficiency of such a CO2 triggered fluid in EGS.

CO2-activated↗

Experimental and Computational Investigations of Plenum-to-Plenum Heat Transfer and Gas Dynamics under Natural Circulation in a Prismatic Very High Temperature Reactor

All the goals and the objectives set for the project were successfully executed and achieved and all the milestones have been successfully completed. The results that have been obtained for the first time advance the scientific and engineering knowledge and understanding of the plenum-to plenum natural convection of prismatic block nuclear reactors that is encountered during accident or abnormal operation. These have been accomplished by developing and implementing for the first time unique and flexible scaled-down separate and integrated effects experimental plenumto- plenum facility (P2PF) with dual channels at this time that has been equipped with sophisticated measurement techniques integrated in a novel way on the heated and cooled channels. The unique facility is an asset now that can be extended to research multiple channels and to study the effects of hot plumes in the plena for future projects if funding will be available. It can also be modified to research natural convection of pebble bed reactors. Hence, it complement the HTTF at Oregon State University. However, in this study, heat transfer coefficients from the inner wall surface to the flowing gas (both helium and air were used) and the radial temperature and gas velocity profiles have been measured and investigated along the height of the heated and cooled channels using in house developed wall flush mounted heat transfer probes, thermocouple with in house developed adjuster for radial movement with 1 mm increment inside the channel and hot wire anemometry with also in house developed adjuster for 1 mm radial movement inside the channel, respectively. Also advanced tracer technique has been developed to quantify also for the first time the dispersion of the gas dynamics of the hot and cold channels. The research has provided new knowledge and new benchmarking data that can be used to validate computational fluid dynamics (CFD) codes with conjugate heat transfer. The work and its results that have been performed within the budget have demonstrated their superior technical effectiveness and high economic feasibility to perform needed studies for safety analysis and assessment at least cost for these types of gas cooled very high temperature 4th generation nuclear reactors. Accordingly, the results obtained in this project and the unique facility and techniques that have been developed will benefit greatly the public by advancing the technology of the prismatic block nuclear reactors toward commercialization and to ensure they will be designed and operated safely by utilizing the obtained knowledge and having well validated CFD simulations integrated with heat transfer computations

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Stress Modeling and Analysis of Packed-bed Thermocline Energy Storage Tank for INL Thermal Energy Distribution System (TEDS)

The Thermal Energy Distribution System (TEDS) at Idaho National Laboratory (INL) is a thermal-hydraulic flow loop to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit for TEDS. The packed-bed TES is adopted in TEDS because of its benefit as a low-cost single-tank storage option compared to the traditional two-tank storage. However, thermal ratcheting is one potential design concern which is caused by the rearrangement of granular filler inside a packed-bed tank during continuous thermal cycling operation of the packed-bed TES tank. If the thermally induced stress exceeds yield strength of the tank wall, it may cause catastrophic consequences like rupture of the thermal storage tank. Thus, it is crucial to understand the phenomenon to ensure the robust operation. Based on the temperature boundary conditions given by transient thermal analyses with computational fluid dynamics (CFD) simulations, the thermal ratcheting analysis is then conducted to evaluate the hoop stress and resultant thermal ratcheting potential of the TES tanks with two different modeling approaches: (1) infinite rigidity model and (2) Drucker-Prager (DP) model. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One Plant and evaluate the thermal ratcheting potential of the TEDS TES tank.

25 ENERGY STORAGE↗

Technology Enablers for Advanced Gasoline Compression Ignition Engines

To meet current emission regulations and increasingly demanding global fleet CO2 standards on fuel economy and future trends towards life cycle GHG emissions, advanced combustion engines remain significant in the passenger vehicle sector to achieve high efficiency and low emissions over the full operating range. Lean burn gasoline compression ignition (GCI) technology has shown to have the most potential in reaching these goals, although it faces challenges in the operating range. In this study, an advanced GCI engine is considered with the capability to operate under two combustion modes, namely low temperature combustion (LTC) and GCI. They are enabled with the use of two Hyundai in-house developed technologies; an advanced valve control mechanism known as continuously variable valve duration (CVVD) and a high-pressure gasoline injection system. At low load, the engine utilizes dual CVVD and dual CVVT (continuously variable valve timing) mechanisms for both intake and exhaust valvetrains to enable NVO (negative valve overlap) to trap hot residuals. The hot residuals enable low load auto-ignition, and the phasing control of that auto-ignition is achieved by varying the degrees of NVO, and in turn, the amount of hot residuals. This is done in real time with respect to the changes in engine loads or operating conditions, significantly improving cylinder-phasing control in LTC mode, and subsequently is able to realize a fuel economy gain and reduced emission benefits. Early direct injection during NVO or intake stroke is used to form homogenous or quasi-homogenous air-fuel mixture for LTC. At mid to high loads, late direct injection of gasoline or GCI mode is employed to take advantage of the high volatility and high resistance to auto-ignition of gasoline fuel, so that diesel-engine like high combustion efficiency can be achieved with lower soot emissions for the same NOx level as diesel combustion. In this paper, the key control and fueling technologies that enable this multiple mode combustion are introduced, and the resultant analysis on engine test and CFD simulation at LTC and GCI operating conditions are presented in detail.

Gasoline compression ignition, low temperature com↗

Dust control for draglines

Monitoring dust levels inside draglines reveals room for improvement in how filtration systems are used and maintained. The Australian firm BMT conducted a field test program to measure airflow parameters, dust fallout rates and dust concentrations, inside and outside the machine house, on four draglines and one shovel. The study involved computational fluid dynamics (CFD) simulations. The article describes how the tests were made and gives results. It was not possible to say which of the two main filtration systems currently used on Australian draglines - Dynavane or Floseps - performs better. It would appear that more frequent maintenance and cleaning would increase the overall filtration performance and systems could be susceptible to repeat clogging in a short time. 2 figs., 1 photos.

01 COAL, LIGNITE, AND PEAT↗