Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmission control protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Biophysical analysis of the plant-specific GIPC sphingolipids reveals multiple modes of membrane regulation

The plant plasma membrane (PM) is an essential barrier between the cell and the external environment, controlling signal perception and transmission. It consists of an asymmetrical lipid bilayer made up of three different lipid classes: sphingolipids, sterols, and phospholipids. The glycosyl inositol phosphoryl ceramides (GIPCs), representing up to 40% of total sphingolipids, are assumed to be almost exclusively in the outer leaflet of the PM. However, their biological role and properties are poorly defined. In this study, we investigated the role of GIPCs in membrane organization. Because GIPCs are not commercially available, we developed a protocol to extract and isolate GIPC-enriched fractions from eudicots (cauliflower and tobacco) and monocots (leek and rice). Lipidomic analysis confirmed the presence of trihydroxylated long chain bases and 2-hydroxylated very long-chain fatty acids up to 26 carbon atoms. The glycan head groups of the GIPCs from monocots and dicots were analyzed by gas chromatograph-mass spectrometry, revealing different sugar moieties. Multiple biophysics tools, namely Langmuir monolayer, ζ-Potential, light scattering, neutron reflectivity, solid state 2H-NMR, and molecular modeling, were used to investigate the physical properties of the GIPCs, as well as their interaction with free and conjugated phytosterols. We showed that GIPCs increase the thickness and electronegativity of model membranes, interact differentially with the different phytosterols species, and regulate the gel-to-fluid phase transition during temperature variations. These results unveil the multiple roles played by GIPCs in the plant PM.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of wafer scale MoS 2 atomic layers grown by metal–organic chemical vapor deposition using organo-metal, organo-sulfide, and H 2 S precursors

Transition Metal Dichalcogenides (TMDs) are a unique class of materials that exhibit attractive electrical and optical properties which have generated significant interest for applications in microelectronics, optoelectronics, energy storage, and sensing. Considering the potential of these materials to impact such applications, it is crucial to develop a reliable and scalable synthesis process that is compatible with modern industrial manufacturing methods. Metal–organic chemical vapor deposition (MOCVD) offers an ideal solution to produce TMDs, due to its compatibility with large-scale production, precise layer control, and high material purity. Optimization of MOCVD protocols is necessary for effective TMD synthesis and integration into mainstream technologies. Additionally, improvements in metrology are necessary to measure the quality of the fabricated samples more accurately. In this work, we study MOCVD of wafer-scale molybdenum disulfide (MoS 2 ) utilizing two common chalcogen precursors, H 2 S and DTBS. We then develop a metrology platform for wafer scale samples quality assessment. For this, the coalesced films were characterized using Raman spectroscopy, atomic force microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Kelvin probe force microscopy. We then correlate the structural analysis of these grown films with electrical performance by using aerosol jet printing to fabricate van der Pauw test structures and assess sheet resistance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parametric study of optical transmission through plasmonic hole arrays modulated by the phase transition of vanadium dioxide

We have performed comprehensive electromagnetic simulations and preliminary experiments to explore the effects of geometrical and material parameters on the extraordinary optical transmission (EOT) through periodic arrays of subwavelength holes in a bilayer stack consisting of a gold or silver film atop a vanadium dioxide film (Au/Ag + VO 2 ), where the latter undergoes a semiconductor-to-metal phase transition. Using the finite-difference time-domain (FDTD) and finite-element methods (FEM), we vary iteratively the array periodicity, VO 2 film thickness and hole diameters, as well as the refractive index inside the VO 2 -layer holes and the VO 2 optical constants. For each variation, we compare the metallic-to-semiconducting ratios of the zero-order transmission ( T 00 ) peaks and find sharp maxima in these ratios within narrow parameter ranges. The maxima arise from Fabry-Perot and Fano-type resonances that minimize T 00 in the semiconducting phase of the perforated bilayers. At a fixed array period, the primary factors controlling the VO 2 -enabled EOT modulation are the VO 2 thickness, diameter of the VO 2 -layer holes, and absorption in the two VO 2 phases. Besides uncovering the origins of the higher metallic-phase T 00 , this study provides a protocol for optimizing the performance of the bilayer hole arrays for potential uses as dynamically tunable nano-optical devices.

Donev, Eugenii U. (ORCID:000000030555219X)↗

Gridtrust: Electricity Grid Root-of-Trust Decentralized Supply Chain Cyber-Security (Final Scientific/Technical Report)

GridTrust represents a departure from reliance on a single organization or a single person to multiple organizations and therefore multiple people across organizational structures. The motivating idea behind involving multiple organizations is the increase in security due to human factors. More specifically, the requirement that distinct people in different organizations sign off on a change or an update makes a cyberattack much less likely due to the inherent requirement that both organizations be penetrated and fooled. GridTrust focuses on the software update process as the primary exemplar for the research and development work. A novel hardware-based technology referred to as a Physical Unclonable Function (PUF) provides a microchip Root-of-Trust (RoT), i.e., a starting point for verifying that the hardware being communicated with is the hardware the control center believes the hardware to be. As a result, staff at power grid control centers can ensure the accurate and reliable identification of hardware devices from the outset. The GridTrust protocol introduces two key innovations, as detailed in this report. Firstly, the utilization of a PUF as a root-of-trust in the initial phase of a software or firmware update. Secondly, the application of multiple cryptographic signatures from two or more organizations to the update binary. These signatures are verified before implementing the update on a power grid device in the field. In terms of GridTrust hardware design, this report outlines two main components. The first is the GridTrust Native Device, integrating PUF technology intrinsically into the hardware device itself. The second is the GridTrust Interfacing Device, which incorporates PUF technology and multiple cryptographic signatures. These signatures are cross-checked within a separate hardware positioned between the power grid control center and the legacy power grid device, functioning as an intermediary. While the GridTrust Interfacing Device offers the advantage of being applicable to existing power grid equipment, it may have reduced security if the intermediary component is targeted. On the other hand, the GridTrust Native Device boasts increased security due to protocol integration within a unified form factor. The effectiveness of GridTrust technology has been extensively demonstrated, with multiple external red-team attackers unable to breach GridTrust's security measures. This was observed both in controlled laboratory settings during Phase 1 of the project and in real-world conditions within a City of Marietta substation during Phase 2 of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CReST-VCT System Integration Framework

In this paper, we propose a system integration framework for deploying the Coordinated Real-time Sub-Transmission Volt-var Control Tool (CReST VCT) functionality between the transmission system, the distribution system, and DERs. This represents one possible set of design choices to implement the coordinated optimization capabilities in an operating environment. The framework provides the following: An architectural reference model that describes how the CReST VCT solution maps into a broader grid architecture that accommodates and enables higher levels of DER penetration and utilization: A system integration reference model that defines a possible allocation of CReST VCT functionality within a utility’s operational environment. This includes one possible system design approach for allocation of functionality within software and protocol selections across the various interfaces; A list of potential performance and security issues that should be considered during an implementation. This framework does not represent a specific implementation of the CReST VCT algorithm or integration into a specific utility environment. It is intended to serve as a reference for those who plan to implement such a solution into their environment. The general model provided by the framework can be tailored to a specific environment based on its specific constraints and requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation: Preprint

Utilities have been installing microgrids due to the advancements in the distributed energy resources technologies. Microgrids also improve the resiliency of the system due to their capability to isolate themselves from the grid and run in islanded mode of operation. Microgrid controllers are management systems that can run the microgrids under varied operating condition and enable the smooth operation of microgrids under various system conditions. It is of high value to de-risk the installation of such controllers. Hardware-in-the-loop evaluation is used by controller developers and utilities to evaluate the controllers under stressful conditions to understand the performance and to understand the necessary improvements to the microgrid controller. In this research work, the team has leveraged the existing infrastructure of real-time simulation at the Energy Systems Integration Facility (ESIF) and the capability of the microgrid controller to control assets over the Internet Protocol (IP) to evaluate a university developed microgrid controller in an efficient and cost-effective manner. The full paper will provide the complete setup, the experimental use cases and the results. In this abstract, one use case will be expalined, and the results from the use case is provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

COVID-19 prevention at institutions of higher education, United States, 2020–2021: implementation of nonpharmaceutical interventions

Background, In early 2020, following the start of the coronavirus disease 2019 (COVID-19) pandemic, institutions of higher education (IHEs) across the United States rapidly pivoted to online learning to reduce the risk of on-campus virus transmission. We explored IHEs’ use of this and other nonpharmaceutical interventions (NPIs) during the subsequent pandemic-affected academic year 2020–2021. Methods, From December 2020 to June 2021, we collected publicly available data from official webpages of 847 IHEs, including all public (n = 547) and a stratified random sample of private four-year institutions (n = 300). Abstracted data included NPIs deployed during the academic year such as changes to the calendar, learning environment, housing, common areas, and dining; COVID-19 testing; and facemask protocols. We performed weighted analysis to assess congruence with the October 29, 2020, US Centers for Disease Control and Prevention (CDC) guidance for IHEs. For IHEs offering ≥50% of courses in person, we used weighted multivariable linear regression to explore the association between IHE characteristics and the summated number of implemented NPIs. Results, Overall, 20% of IHEs implemented all CDC-recommended NPIs. The most frequently utilized NPI was learning environment changes (91%), practiced as one or more of the following modalities: distance or hybrid learning opportunities (98%), 6-ft spacing (60%), and reduced class sizes (51%). Additionally, 88% of IHEs specified facemask protocols, 78% physically changed common areas, and 67% offered COVID-19 testing. Among the 33% of IHEs offering ≥50% of courses in person, having < 1000 students was associated with having implemented fewer NPIs than IHEs with ≥ 1000 students. Conclusions, Only 1 in 5 IHEs implemented all CDC recommendations, while a majority implemented a subset, most commonly changes to the classroom, facemask protocols, and COVID-19 testing. IHE enrollment size and location were associated with degree of NPI implementation. Additional research is needed to assess adherence to NPI implementation in IHE settings.

59 BASIC BIOLOGICAL SCIENCES↗

National Virtual Biotechnology Laboratory: Report on Rapid R&D Solutions to the COVID-19 Crisis

With funding from the CARES Act, the U.S Department of Energy (DOE) established the National Virtual Biotechnology Laboratory (NVBL) in March 2020 to address key challenges associated with the COVID-19 crisis. NVBL brought together the broad scientific and technical expertise and resources of DOE’s 17 national laboratories to help tackle medical supply short ages, discover potential drugs to fight the virus, develop and validate COVID-19 testing methods, model disease spread and impact across the nation, and understand virus transport in buildings and the environment. National laboratory resources leveraged for this effort include a suite of world-leading user facilities broadly available to the research community, such as light and neutron sources, nanoscale science research centers, sequencing and biocharacterization facilities, and high-performance computing facilities. Within months, NVBL teams produced innovations in materials and advanced manufacturing that mitigated shortages in test kits and personal protective equipment (PPE), creating nearly 1,000 new jobs. They used DOE’s high-performance computers and light and neutron sources to identify promising candidates for antibodies and antivirals that universities and drug companies are now evaluating. NVBL researchers also developed new diagnostic targets and sample collection approaches, and supported U.S. Food and Drug Administration (FDA), Centers for Disease Control and Prevention (CDC), and U.S. Department of Defense (DoD) efforts to establish national guidelines used in administering millions of tests. Researchers used artificial intelligence and high-performance computing to produce near-real-time data analysis to forecast disease transmission, stress on public health infrastructure, and economic impact, which supported decision-makers at the local, state, and national levels. NVBL teams also studied how to control indoor virus movement to minimize uptake and protect human health. NVBL’s accomplishments demonstrate not only the powerful resource represented by DOE’s national laboratories working together to meet national needs, but also the effectiveness of the integrated NVBL framework for rapidly responding to emergencies with research and development (R&D) solutions. As the fight against COVID continues, sustained efforts are needed to confront this pandemic as well as future threats. Examples include: 1) Establishing “supply chains on demand” to meet emergency production needs by leveraging the materials and manufacturing expertise of DOE national laboratories and developing advances in electronics, sensing, robotics, and automation capabilities; 2) Improving the speed and robustness of drug discovery by integrating experimental platforms with DOE’s computational and experimental user facilities, which provide unique resources to support the discovery of high-potential therapeutic agents; 3) Protecting public, environmental, and animal health by developing new testing protocols and instrumentation adaptable to diverse sample types (both physiological and environmental) to quickly detect a wide range of pathogens and monitor other biorisks; 4) Supporting near-real-time data needs of decision-makers at the local, regional, state, and national levels by advancing data curation, analysis, and modeling using artificial intelligence and new data science tools for managing and evaluating large diverse datasets; 5) Harnessing DOE’s expertise in environmental modeling to design rooms and air handling for offices, classrooms, restaurants, and other structures to minimize biorisk transmissions. Going forward, NVBL is poised to apply the unique capabilities and expertise of the national laboratory complex to future national and international emergencies, both natural and engineered. Through this framework, the Office of Science will continue to be an integral component of agency wide efforts to prepare for and respond to biorisks and other crises.

42 ENGINEERING↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

An Advanced Cyber-Physical System Security Testbed for Substation Automation

A Cyber-Physical System (CPS) testbed serves as a powerful platform for testing and validating cyber intrusion detection and mitigation strategies in substations. This study presents the design and development of a CPS testbed that can effectively assess the real-time dynamics of a substation. Cyber attacks exploiting IEC 61850-based SV and GOOSE protocols are demonstrated using the testbed, along with an analysis on attack detection. Realistic timing measurements are obtained, and the time frames for deploying detection and mitigation strategies are evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ChargeX OCPI Recommendations

The Open Charge Point Interface (OCPI) is an open protocol that enables electric vehicle (EV) charging systems to work together across networks. It supports communication and data sharing between Charge Point Operators (CPOs), who manage charging stations, and e-Mobility Service Providers (eMSPs), who provide charging services to EV drivers. OCPI facilitates functions like user authorization, remote charge point control, charging session data exchange, and billing through Charge Detail Records (CDRs). This allows EV roaming, so drivers can charge at different networks without multiple accounts. As the EV market grows due to increased adoption and technological advancements, OCPI faces higher demands. This has revealed issues with CDR format consistency, timestamp standardization across regions, transmission of EV-side error codes for troubleshooting, and support for new use cases. These challenges can affect operations and user experience, particularly as the industry starts considering Vehicle-to-Grid (V2G) systems, where EVs supply energy to the grid, and Vehicle-to-Everything (V2X) technologies for broader energy interactions. Using feedback from the ChargeX Diagnostics taskforce discussions, industry 1-on-1 meetings, technical standards, and OCPI’s evolution through versions (e.g., OCPI 2.1.1, 2.2, and 2.2.1), this report identifies these issues and suggests practical recommendations. These aim to improve interoperability, streamline operations, and prepare OCPI for future trends in the EV charging ecosystem.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Demand Response Optimization and Management System for Real-TIme (DROMS-RT)

To design and demonstrate DROMS-RT, a highly distributed Demand Response Optimization and Management System for Real-Time (DROMS-RT) power flow control to support large scale integration of distributed renewable generation into the grid. AutoGrid developed a novel control and communications platform to allow highly dispatchable demand response (DR) services in time frames suitable for providing ancillary services to the transmission grid. These services will be substantially less expensive and more efficient than other forms of ancillary services options currently available to manage the intermittency associated with large-scale renewable integration. DROMSRT successfully leveraged Automated Demand Response (ADR) by fundamentally re-thinking the architecture of the DR platform from the ground up and by developing innovative new technologies in a number of areas related to DR. DROMS-RT leveraged the low-cost, open, interoperable DR signaling technology, OpenADR, and low-cost, internet-protocol based telemetry solutions to reduce the cost of hardware. This allowed DROMS-RT to provide dynamic price signals to millions of OpenADR clients. Statistically rigorous signal processing techniques were developed to reliably detect even small load reductions in the presence of noisy baseline profiles. Novel forecasting engines based on modern online machine learning algorithms enabled accurate individualized forecasts for customer loads in the presence of dynamic pricing signals, and a real-time decision engines enabled continuous optimization and optimal dispatch of DR resources across a large portfolio of heterogeneous loads that respond at varying time-scales. Moreover, the real-time optimization conducted by the decision engine can utilize grid physics to maximize load reduction at the transmission system in addition to the distribution sites, for more efficient grid operation. Finally, the Software-as-a-Service (SaaS) availability of the DROMS-RT platform has reduced the cost of deployment and enable participation of small commercial and residential customers in DR who otherwise would not be able to do so.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quality-Controlled Meteorological Data from the Flood Control District of Maricopa County (FCDMC) Network, Phoenix, Arizona (1987-2024)

This dataset contains 15- or 30-minute interval meteorological data from the Flood Control District of Maricopa County (FCDMC), Arizona, USA, covering eight key variables across multiple sensor stations between 1987 and 2024. Each variable is stored as a separate CSV file, containing time-series data that have undergone rigorous quality control (QC) procedures and, where appropriate, short-gap interpolation for consistency. The quality control (QC) pipeline consisted of four sequential tests: (1) a range test to ensure all values fall within physically realistic limits, (2) a step test to identify abrupt and implausible changes between consecutive records, (3) a proximity test that validates flagged values from step test using data from nearby stations and exceedance probability thresholds, and (4) a persistence test to detect and remove periods of unrealistically constant readings. These thresholds were calibrated to Arizona’s environmental conditions and sensor specifications. After QC, short gaps (≤2 hours) were linearly interpolated to ensure consistent temporal resolution, except for wind variables. Due to a major upgrade in FCDMC’s data transmission system, only ALERT-2 protocol data (2016–2024) for wind variables are included; earlier ALERT-1 data were excluded because of irregular sampling and high missing rates. This dataset supports regional climate and infrastructure resilience studies by providing standardized, high-resolution meteorological data for the greater Phoenix metropolitan area.

54 ENVIRONMENTAL SCIENCES↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗