Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fiber optic electric field sensor technology

The properties of piezoactive plastics are reviewed as well as the fiber-optic electric field sensors studied so far. A particular configuration consisting of a concentric piezoactive jacket on the glass fiber is discussed in detail and the frequency response of this sensor is projected over a wide range of frequencies. The present design has the practical advantages of leading to a compact lightweight sensor; longer fiber lengths may be used to increase sensitivity. It is predicted that, at low frequencies, a fiber-optic antenna using a 1-km length of fiber would be capable of detecting a minimum electric field of 43 microV/m assuming a minimum phase sensitivity of 10 to the -6th radians for the optical Mach-Zehnder interferometer.

Jarzynski, J.↗

Coherent Doppler Wind Lidar Technology for Space Based Wind Measurements Including SPARCLE

It has been over 30 years since coherent lidar systems first measured wind velocity, and over 20 years since the "ultimate application" of measuring Earth's winds from space was conceived. Coherent or heterodyne optical detection involves the combination (or mixing) of the returned optical field with a local oscillator (LO) laser's optical field on the optical detector. This detection technique yields the benefits of dramatically improved signal-to-noise ratios; insensitivity to detector noise, background light and multiply scattered light; reduction of the returned signal's dynamic range; and preservation of the optical signal spectrum for electronic and computer processing. (Note that lidar systems are also referred to as optical radar, laser radar, and LADAR systems.) Many individuals, agencies, and countries have pursued the goal of space-based wind measurements through technology development, experiments, field campaigns and studies.

Kavaya, Michael J.↗

Optical Potential Field Mapping System

The present invention relates to an optical system for creating a potential field map of a bounded two dimensional region containing a goal location and an arbitrary number of obstacles. The potential field mapping system has an imaging device and a processor. Two image writing modes are used by the imaging device, electron deposition and electron depletion. Patterns written in electron deposition mode appear black and expand. Patterns written in electron depletion mode are sharp and appear white. The generated image represents a robot's workspace. The imaging device under processor control then writes a goal location in the work-space using the electron deposition mode. The black image of the goal expands in the workspace. The processor stores the generated images, and uses them to generate a feedback pattern. The feedback pattern is written in the workspace by the imaging device in the electron deposition mode to enhance the expansion of the original goal pattern. After the feedback pattern is written, an obstacle pattern is written by the imaging device in the electron depletion mode to represent the obstacles in the robot's workspace. The processor compares a stored image to a previously stored image to determine a change therebetween. When no change occurs, the processor averages the stored images to produce the potential field map.

Reid, Max B.↗

Near-Field Scanning Optical Microscopy of Soft, Biological, or Rough Objects in Aqueous Environment: Challenges and some Remedies to Circumvent

Near-field scanning optical microscopy is an established technique for sub-wavelength spatial resolution in imaging, spectroscopy, material science, surface chemistry, polarimetry, etc. A significant amount of confidence has been established for thin hard specimens in air. However when soft, biological, rough, in aqueous environment object, or a combination is involved, the progress has been slow. The tip-sample mechanical interaction, heat effects to sample, drag effects to the probe, difficulty in controlling tip-sample separation in case of rough objects, light scattering from sample thickness, etc. create problems. Although these problems are not even fully understood, there have been attempts to study them with the aim of performing reliable operations. In this review we describe these attempts. Starting with general problems encountered, various effects like polarization, thermal, and media are covered. The roles of independent tip-sample distance control tools in the relevant situations are then described. Finally progress in fluid cell aspect has been summarized.

Vikram, C. S.↗

Spatially Extended Modelocking

We examine the properties of optical fields that are extended in space over transverse dimensions of several meters or more in terms of both multiple spatial modes and also multiple temporal modes. We focus attention on the task of producing and maintaining well defined phase relationships for the set of spatial and temporal modes. In particular, we address operating regimes where the optical fields are not confined within an optical resonator, but still have well defined phase relations through the use of optical field sensing and correction techniques. Special applications of interest occur in safe beaming of optical power and in approaching optical intensities capable of producing nonlinear phenomena in the vacuum.

Fork, Richard L.↗

Chemical Silver Coating of Fiber Tips in Near-Field Scanning Optical Microscopy

We report what is believed to be the first experimental demonstration of silver coating by a wet chemical process on tapered fiber tips used in near-field scanning optical microscopy. The process is at room temperature and pressure and takes only a few minutes to complete. Many tips can be simultaneously coated.

Vikram, Chandra S.↗

Near-Field Spectroscopy with Nanoparticles Deposited by AFM

An alternative approach to apertureless near-field optical spectroscopy involving an atomic-force microscope (AFM) entails less complexity of equipment than does a prior approach. The alternative approach has been demonstrated to be applicable to apertureless near-field optical spectroscopy of the type using an AFM and surface enhanced Raman scattering (SERS), and is expected to be equally applicable in cases in which infrared or fluorescence spectroscopy is used. Apertureless near-field optical spectroscopy is a means of performing spatially resolved analyses of chemical compositions of surface regions of nanostructured materials. In apertureless near-field spectroscopy, it is common practice to utilize nanostructured probe tips or nanoparticles (usually of gold) having shapes and dimensions chosen to exploit plasmon resonances so as to increase spectroscopic-signal strengths. To implement the particular prior approach to which the present approach is an alternative, it is necessary to integrate a Raman spectrometer with an AFM and to utilize a special SERS-active probe tip. The resulting instrumentation system is complex, and the tasks of designing and constructing the system and using the system to acquire spectro-chemical information from nanometer-scale regions on a surface are correspondingly demanding.

Anderson, Mark S.↗

Time-to-Passage Judgments in Nonconstant Optical Flow Fields

The time until an approaching object will pass an observer (time to passage, or TTP) is optically specified by a global flow field even in the absence of local expansion or size cues. Kaiser and Mowafy have demonstrated that observers are in fact sensitive to this global flow information. The present studies investigate two factors that are usually ignored in work related to TTP: (1) non-constant motion functions and (2) concomitant eye rotation. Non-constant velocities violate an assumption of some TTP derivations, and eye rotations may complicate heading extraction. Such factors have practical significance, for example, in the case of a pilot accelerating an aircraft or executing a roll. In our studies, a flow field of constant-sized stars was presented monocularly on a large screen. TIP judgments had to be made on the basis of one target star. The flow field varied in its acceleration pattern and its roll component. Observers did not appear to utilize acceleration information. In particular, TTP with decelerating motion were consistently underestimated. TTP judgments were fairly robust with respect to roll, even when roll axis and track vector were decoupled. However, substantial decoupling between heading and track vector led to a decrement in performance, in both the presence and the absence of roll.

Kaiser, Mary K.↗

Design, Build, and Testing of the Roman Space Telescope’s Wide Field Instrument Optical Stimulus System (SORC)

The Stimulus Of Ray Cones (SORC) is an optical stimulus system developed to verify, characterize, and calibrate the Roman Space Telescope’s (RST) Wide Field Instrument (WFI) under simulated operational conditions. SORC provides several critical test modes, the primary being point-source mode, which projects an image anywhere on the Focal Plane Assembly (FPA) detectors. This mode provides precise position knowledge of the FPA within WFI. Additional modes enable capturing WFI pupil alignment, evaluation of WFI’s selectable optical elements, and verification of focal plane fiber operation for higher-level system testing. The light source system incorporates a suite of narrowband and broadband fiber fed sources spanning the visible to near-infrared range, with options for pulsed or continuous wave illumination. SORC was designed and built at NASA’s Goddard Spaceflight Center (GSFC). Initial system-level testing occurred under ambient conditions in GSFC’s Spacecraft Systems Development and Integration Facility (SSDIF), followed by vacuum testing at operational temperatures (SORC at 214-222 K) in the Space Environment Simulator (SES). The system was then shipped to BAE Systems in Boulder, CO for post-shipment ambient and cryogenic testing before integration with WFI for two thermal vacuum test campaigns at cryogenic temperatures. This presentation will focus on design, development, and performance of SORC. Details of WFI verification and calibration using SORC, along with test results, have been published previously and will be referenced only as needed to describe SORC. The SORC ground test capability is critical to ensuring WFI meets stringent optical performance requirements, directly supporting the mission’s science objectives.

Stimulus of Ray Cones↗

Optical Amplifier for Space Applications

We describe an open multipass optical amplifier designed to amplify a sampled region of an optical wavefront to kilowatt average power with low optical phase distortion. The overall goal is to amplify optical fields in a segmented, but phase coherent manner, so as to achieve high average power optical fields with high quality phase coherence over the large apertures needed for transmission of space solar power.

Fork, Richard L.↗

Optical amplifiers for coherent lidar

We examine application of optical amplification to coherent lidar for the case of a weak return signal (a number of quanta of the return optical field close to unity). We consider the option that has been explored to date, namely, incorporation of an optical amplifier operated in a linear manner located after reception of the signal and immediately prior to heterodyning and photodetection. We also consider alternative strategies where the coherent interaction, the nonlinear processes, and the amplification are not necessarily constrained to occur in the manner investigated to date. We include the complications that occur because of mechanisms that occur at the level of a few, or one, quantum excitation. Two factors combine in the work to date that limit the value of the approach. These are: (1) the weak signal tends to require operation of the amplifier in the linear regime where the important advantages of nonlinear optical processing are not accessed, (2) the linear optical amplifier has a -3dB noise figure (SN(out)/SN(in)) that necessarily degrades the signal. Some improvement is gained because the gain provided by the optical amplifier can be used to overcome losses in the heterodyned process and photodetection. The result, however, is that introduction of an optical amplifier in a well optimized coherent lidar system results in, at best, a modest improvement in signal to noise. Some improvement may also be realized on incorporating more optical components in a coherent lidar system for purely practical reasons. For example, more compact, lighter weight, components, more robust alignment, or more rapid processing may be gained. We further find that there remain a number of potentially valuable, but unexplored options offered both by the rapidly expanding base of optical technology and the recent investigation of novel nonlinear coherent interference phenomena occurring at the single quantum excitation level. Key findings are: (1) insertion of linear optical amplifiers in well optimized conventional lidar systems offers modest improvements, at best, (2) the practical advantages of optical amplifiers, especially fiber amplifiers, such as ease of alignment, compactness, efficiency, lightweight, etc., warrant further investigation for coherent lidar, (3) the possibility of more fully optical lidar systems should be explored, (4) advantages gained by use of coherent interference of optical fields at the level of one, or a few, signal quanta should be explored, (5) amplification without inversion, population trapping, and use of electromagnetic induced transparency warrant investigation in connection with coherent lidar, (6) these new findings are probably more applicable to earth related NASA work, although applications to deep space should not be excluded, and (7) our own work in the Ultrafast Laboratory at UAH along some of the above lines of investigation, may be useful.

Fork, Richard↗

A laboratory investigation of the reflective properties of simulated, optically thick clouds

The Cloud Field Optical Simulator project includes work in the following areas: (1) improvement in the shape of the desired (visible) spectral response of the measurement, (2) selection of two usable materials for cloud simulation, (3) a means of assigning a visible optical depth to the simulated clouds, and (4) confirmation that the apparatus is capable of detecting basic finite cloud characteristics. A brief description of the accomplishments in each of these areas is presented.

Mckee, T. B.↗

Hyperspectral Imager-Tracker

The Hyperspectral Imager-Tracker (HIT) is a technique for visualization and tracking of low-contrast, fast-moving objects. The HIT architecture is based on an innovative and only recently developed concept in imaging optics. This innovative architecture will give the Light Prescriptions Innovators (LPI) HIT the possibility of simultaneously collecting the spectral band images (hyperspectral cube), IR images, and to operate with high-light-gathering power and high magnification for multiple fast- moving objects. Adaptive Spectral Filtering algorithms will efficiently increase the contrast of low-contrast scenes. The most hazardous parts of a space mission are the first stage of a launch and the last 10 kilometers of the landing trajectory. In general, a close watch on spacecraft operation is required at distances up to 70 km. Tracking at such distances is usually associated with the use of radar, but its milliradian angular resolution translates to 100- m spatial resolution at 70-km distance. With sufficient power, radar can track a spacecraft as a whole object, but will not provide detail in the case of an accident, particularly for small debris in the onemeter range, which can only be achieved optically. It will be important to track the debris, which could disintegrate further into more debris, all the way to the ground. Such fragmentation could cause ballistic predictions, based on observations using high-resolution but narrow-field optics for only the first few seconds of the event, to be inaccurate. No optical imager architecture exists to satisfy NASA requirements. The HIT was developed for space vehicle tracking, in-flight inspection, and in the case of an accident, a detailed recording of the event. The system is a combination of five subsystems: (1) a roving fovea telescope with a wide 30 field of regard; (2) narrow, high-resolution fovea field optics; (3) a Coude optics system for telescope output beam stabilization; (4) a hyperspectral-mutispectral imaging assembly; and (5) image analysis software with effective adaptive spectral filtering algorithm for real-time contrast enhancement.

Agurok, Llya↗