Quantifying neutron scintillator screens with X-ray computed tomography
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Ultrasonic inspection of cast austenitic stainless steel (CASS) in the nuclear industry is particularly challenging because of sound field scatter and attenuation caused by the coarse-grained microstructure. Modeling and simulation are important tools in ultrasonic testing, as they can be used to help address key aspects of inspections, such as developing new probe designs, predicting inspection reliability, and testing phased-array focal laws. However, developing a useful and reliable CASS model is challenging due to the many grain interfaces and crystalline orientations that must be captured. We demonstrate a method of creating a realistic CASS model that is usable in CIVA, a commercially available modeling and simulation software platform. Using polished and chemically etched sections, we generate models of a coarse-grained equiaxed specimen and a columnar specimen. We also test an alternative method of generating a coarse-grained model using Voronoi regions. We qualitatively compare sound field scatter and quantitatively compare sound field attenuation and beam partitioning in simulated sound fields to those of laboratory-measured sound fields. Results show that the Voronoi models perform as well as or better than the models based on actual grain morphology. Here we also show that model-to-model randomness in Voronoi grain structure can impact the magnitude of a simulated echo response by a factor of two or more. Although CASS models are potentially a good depiction of reality for a given scenario, they should not be considered representative since CASS morphology can change significantly from specimen to specimen or within the same specimen.
Microstructural characterization of composite high explosives (HEs) has become increasingly important over the last several decades in association with the development of high fidelity mesoscale modeling and an improved understanding of ignition and detonation processes. HE microstructure influences not only typical material properties (e.g., thermal, mechanical) but also reactive behavior (e.g., shock sensitivity, detonation wave shape). A detailed nondestructive 3D examination of the microstructure has generally been limited to custom-engineered samples or surrogates due to poor contrast between the composite constituents. Highly loaded (>90 wt%) HE composites such as plastic-bonded explosives (PBX) are especially difficult. Here, we present efforts to improve measurement quality by using single and dual-energy microcomputed X-ray tomography and state-of-the-art image processing techniques to study a broad set of HE materials. Some materials, such as PBX 9502, exhibit suitable contrast and resolution for an automatic segmentation of the HE from the polymer binder and the voids. Other composite HEs had varying levels of success in segmentation. Post-processing techniques that used commercially available algorithms to improve the segmentation quality of PBX 9501 as well as zero-density defects such as cracks and voids could be easily segmented for all samples. Aspects of the materials that lend themselves well to this type of measurement are discussed.
This report presents the Technical Program Plan for FY 2019 for the Department of Energy Light Water Reactor Sustainability Program – Plant Modernization research pathway. A summary of the vision and strategy is provided to explain how this program addresses key issues and barriers for modernizing instrumentation and control technologies and infrastructure in domestic nuclear power plants. The report describes the pilot projects that have been formulated to develop and validate enabling technologies over the next several years that will result in digital alternatives to the legacy analog II&C systems in place today. This will allow much needed modernization of these systems to address reliability and obsolescence problems, as well as serve as a platform for substantial operational improvement. The report further describes key project resources and cooperative relationships, including the Electric Power Research Institute, the Nuclear Energy Institute )NEI), the Institute of Nuclear Power Operations (INPO), the IFE Halden Reactor Project, the Nuclear Regulatory Commission, and industry suppliers, that are instrumental to the success of the program. The report also lists the schedule for all program products, including the titles and report numbers for all published reports under this program.
This report presents the Technical Program Plan for FY 2019 for the Department of Energy Light Water Reactor Sustainability Program – Plant Modernization research pathway. A summary of the vision and strategy is provided to explain how this program addresses key issues and barriers for modernizing instrumentation and control technologies and infrastructure in domestic nuclear power plants. The report describes the pilot projects that have been formulated to develop and validate enabling technologies over the next several years that will result in digital alternatives to the legacy analog II&C systems in place today. This will allow much needed modernization of these systems to address reliability and obsolescence problems, as well as serve as a platform for substantial operational improvement. The report further describes key project resources and cooperative relationships, including the Electric Power Research Institute, the Nuclear Energy Institute )NEI), the Institute of Nuclear Power Operations (INPO), the IFE Halden Reactor Project, the Nuclear Regulatory Commission, and industry suppliers, that are instrumental to the success of the program. The report also lists the schedule for all program products, including the titles and report numbers for all published reports under this program.
Nondestructive post-irradiation examination of nuclear fuels and materials is useful in collecting data to inform commercial licensing of new nuclear concepts. This work details the planning, shielding design, and workflow of an X-ray computed tomography examination of an irradiated AGR-5/6/7 fuel compact with a dose rate of 1318 R/hr on contact from both β and ɤ-ray radiation with 120 R/hr of the dose rate coming exclusively from ɤ-rays. Post-irradiation examination of highly radioactive samples can help reduce the timeframe from conceptualization of novel nuclear concepts to their commercial implementation as not only is less time spent waiting for experiments to decay away to acceptable levels for examinations, but data from these experiments can more quickly inform model efforts and subsequent experiments. While this work represents the hottest radiological sample that has been openly transported and examined at Idaho National Laboratory’s Irradiated Materials Characterization Laboratory to date, it is anticipated that this work and its lessons learned will facilitate future examinations of similar or even more radioactive specimens.
Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.
A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.
Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study.
CFRP composites have not been used for nuclear safety-related applications until recently. In 2019, the ASME Boiler and Pressure Vessel Code Committee approved a new Code Case N-871 for internal repairs of Class 2 and 3 safety-related piping using CFRP for Service Levels A, B, C, and D for a service life of 50 years. The NRC did not review N-871 for inclusion in the Code Case Regulatory Guides. This project focuses on evaluating the capabilities and limitations of Nondestructive Evaluation (NDE) methods for examining the Carbon Fiber Reinforced Polymer (CFRP) repairs in commercial nuclear power plants (NPPs). This Report summarizes the work done on this project until the end of FY24.
The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.
Fabricated ecosystems (EcoFABs) offer an innovative approach to in situ examination of microbial establishment patterns around plant roots using nondestructive, high-resolution microscopy. Previously high-resolution imaging was challenging because the roots were not constrained to a fixed distance from the objective. Here, we describe a new ‘Imaging EcoFAB’ and the use of this device to image the entire root system of growing Brachypodium distachyon at high resolutions (20×, 40×) over a 3-week period. The device is capable of investigating root–microbe interactions of multimember communities. We examined nine strains of Pseudomonas simiae with different fluorescent constructs to B. distachyon and individual cells on root hairs were visible. Succession in the rhizosphere using two different strains of P. simiae was examined, where the second addition was shown to be able to establish in the root tissue. The device was suitable for imaging with different solid media at high magnification, allowing for the imaging of fungal establishment in the rhizosphere. Overall, the Imaging EcoFAB could improve our ability to investigate the spatiotemporal dynamics of the rhizosphere, including studies of fluorescently-tagged, multimember, synthetic communities.
Microadditive manufacturing has revolutionized the production of complex, nano- to microscale components across various fields. This work investigates two-photon (2P) and three-photon (3P) fluorescence imaging, as well as third-harmonic generation (THG) microscopy, to examine periodic microarchitected lattice structures fabricated using multiphoton lithography (MPL). By immersing the structures in refractive index matching fluids, we demonstrate high-fidelity 3D reconstructions of both fluorescent structures using 2P and 3P microscopy as well as low-fluorescence structures using THG microscopy. These results show that multiphoton fluorescence (MPF) imaging offers reduced signal decay with respect to depth compared to single-photon techniques in the examined structures. We further demonstrate the ability to nondestructively identify intentional internal modifications of the structure that are not immediately visible with scanning electron microscope (SEM) images and compression-induced fractures, highlighting the potential of these techniques for quality control and defect detection in microadditively manufactured components.
Carbon fiber characterization processes are described that include multi-condition Raman spectroscopy-based examination combined with multivariate data analyses. Methods are a nondestructive material characterization approach that can provide predictions as to carbon fiber bulk physical properties, as well as identification of unknown carbon fiber materials for quality control purposes. The framework of the multivariate analysis methods includes a principal component-based identification protocol including comparison of Raman spectral data from an unknown carbon fiber with a data library of multiple principal component spaces.
The processing of used nuclear fuels and related materials is often complex and variable. The ability to quickly optimize conditions to the material being processed can aid in increasing efficiency and safety, but requires very quick determination of the conditions present in the feedstock, the process, and the product. Furthermore, accurate quantification of materials such as enriched uranium and plutonium aids in maintaining material accountancy and avoiding nuclear proliferation risks. Traditional analytical methods require process samples to be collected and analyzed in a laboratory, which often takes days to weeks. Online monitoring is suitable for collecting this information nearly instantaneously, enabling much faster optimization of the process or detection of material diversion. Online monitoring is also beneficial as it is typically based on robust and nondestructive analytical methods, so no material is removed as samples. This review examines online monitoring relevant to used nuclear fuel processing for the determination of both chemical and physical parameters. The chemical parameters include quantities such as concentration, isotopic composition, and speciation. These values are often well suited to spectroscopic or spectrometric measurements as they are fast, nondestructive, and easily implemented in an online manner. Physical quantities are often more varied and include temperature, pressure, tank fill levels, and others. Due to the specificity of these quantities, specialized instrumentation is often used. However, this instrumentation is often amendable to online monitoring.
The purpose of a nondestructive assay is to accurately verify the declared mass of special nuclear material (SNM) samples in a limited amount of time. One measurement modality is neutron multiplicity counting (NMC), which relates time-correlated neutron detection rates to the mass of SNM present. Traditional theory assumes point-like sources, which can be ill-posed for kilogram-quantity, bulk samples. Recent theory was developed to improve NMC accuracy for non-point-like samples. This work preliminarily examines the theory with measured data. The OSCAR prototype (a 3-by-4 array of 5.08-cm-thick, 5.08-cm-diameter trans-stilbene organic scintillators) measures configurations of 29.41-49.00 kg of highly enriched uranium (93wt% 235 U). Adjusted factorial moments for the emitted neutron multiplicity distributions are used to account for the shape and type of SNM being measured.
The Pacific Northwest National Laboratory (PNNL) undertook the Materials Characterization, Prediction, and Control (MCPC) Laboratory Directed Research and Development (LDRD) Project to advance understanding of nuclear material processing and enable multifold acceleration in the development and qualification of new material systems produced via advanced manufacturing methods, such as solid phase processing, for use in national security and advanced energy applications (Smith 2021). As a two-year LDRD investment requiring focused research, the MCPC project applied only a subset of the wide range of available destructive and nondestructive characterization methods to provide data to the predictive modeling and data analytics tasks. The purpose of this report is to review a wide range of destructive and nondestructive characterization methods that are relevant in solid-phase processing (SPP) applications, but not necessarily applied in the MCPC Project as a guide to the planning of characterization activities in future research. Particular attention is given to measured characteristics that can correlate to other material characteristics, with a particular interest in nondestructive evaluation (NDE) that can be applied to samples obtained in the MCPC Project. Destructive examinations include tensile tests, optical and electron microscopy, micro-hardness, and residual stress tests. NDE tests include surface visual inspection, eddy current examination for cracks, 4-point potential drop, ultrasound, x-ray, and computed tomography.
A post-irradiation examination (PIE) of an enriched uranium sample was performed to advance a nuclear forensics methodology, based on intra-elemental nuclide ratios. The PIE was carried out on a few milligrams of low enriched uranium dioxide (LEUO 2 ) sample, irradiated to a burnup of 1 GWd/MTU. The PIE of the LEUO 2 sample provided the concentration of selected plutonium and fission product nuclides ( 239 Pu, 240 Pu, 241 Pu, 91 Y, 95 Zr, 95 Nb, 103 Ru, 133 Cs, 134 Cs, 135 Cs, 137 Cs, 136 Ba, 138 Ba, 140 Ba, 140 La, 141 Ce, 144 Ce, 149 Sm, 150 Sm, 152 Sm, 153 Eu, and 154 Eu). The PIE supported validation of the MCNP (Monte Carlo N-Particle neutronics simulation code) predicted concentration of these nuclides in the irradiated LEUO 2 sample. This study showed that most of the MCNP predicted nuclide concentrations were within 15% and several within 10% compared to the PIE results. Furthermore, gamma and mass spectrometry of nuclides in irradiated LEUO 2 enabled the determination of uranium burnup and time since irradiation.