Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

First Measurement of Deeply Virtual Compton Scattering on the Neutron with Detection of the Active Neutron

Measuring deeply virtual Compton scattering (DVCS) on the neutron is one of the necessary steps to understand the structure of the nucleon in terms of generalized parton distributions (GPDs). Neutron targets play a complementary role to transversely polarized proton targets in the determination of the GPD E . This poorly known and poorly constrained GPD is essential to obtain the contribution of the quarks’ angular momentum to the spin of the nucleon. DVCS on the neutron was measured for the first time selecting the exclusive final state by detecting the neutron, using the Jefferson Lab longitudinally polarized electron beam, with energies up to 10.6 GeV, and the CLAS12 detector. The extracted beam-spin asymmetries, combined with DVCS observables measured on the proton, allow a clean quark-flavor separation of the imaginary parts of the Compton form factors H and E . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of neutron production in atmospheric neutrino interactions at Super-Kamiokande

We present measurements of total neutron production from atmospheric neutrino interactions in water, analyzed as a function of electron-equivalent visible energy over a range of 30 MeV to 10 GeV. These results are based on 4,270 days of data collected by Super-Kamiokande, including 564 days with 0.011 wt% gadolinium added to enhance neutron detection. Neutron signal selection is based on a neural network trained on simulation, with its performance validated using an Am/Be neutron point source. The measurements are compared to predictions from neutrino event generators combined with various hadron-nucleus interaction models, which include an intranuclear cascade model and a nuclear deexcitation model. We observe significant variations in the predictions depending on the choice of hadron-nucleus interaction model. We discuss key factors that contribute to describing our data, such as in-medium effects in the intranuclear cascade and the accuracy of statistical evaporation modeling.

Cherenkov detectors↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

Double Chooz {theta}13 measurement via total neutron capture detection

Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (nu(1), nu(2), nu(3)) are mixtures of their flavour eigenstates (nu(e), nu(mu), nu(tau)). The oscillations between different flavour eigenstates are described by three mixing angles (theta(12), theta(23), theta(13)), two differences of the squared neutrino masses of the nu(2)/nu(1) and nu(3)/nu(1) pairs and a charge conjugation parity symmetry violating phase delta(CP). The Double Chooz experiment, located near the Chooz Electricite de France reactors, measures the oscillation parameter theta(13) using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle theta(13) with the new total neutron capture detection technique from the full data set, yielding sin(2)(2 theta(13)) = 0.105 +/- 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission <sigma(f)& rang; = (5.71 +/- 0.06) x 10(-43) cm(2) per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum. The Double Chooz collaboration reports the neutrino oscillation parameter theta(13) from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.

Djurcic, Z.↗

Towards a neutron multiplicity measurement with the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26 ton Gadolinium (Gd)-loaded water Cherenkov detector located on the Booster Neutrino Beam line at Fermilab. Its main goals are the measurement of the neutron multiplicity in neutrino-nucleus interactions as well as the cross-section of Charged Current Quasi-Elastic (CCQE) neutrino interactions on water. Besides the physics goals, the experiment also aims to be a testbed for new technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillators (WbLS). This thesis presents a preliminary measurement of the neutron multiplicity with {ANNIE}, using an analysis conducted on a fraction of the 2021 beam year. As preparatory measures, the efficiency of ANNIE's Front Muon Veto (FMV) was determined to be {$\bar{\varepsilon}_{\mathrm{FMV}} = (95.6 \pm 1.6)\%$} while the average efficiency for active scintillator paddles in the Muon Range Detector (MRD) was found to be {$\bar{\varepsilon}_ {\mathrm{MRD}} = (92.1 \pm 7.9)\%$}. Furthermore, the simulation framework used for ANNIE was validated and adapted to reproduce the experimental data by comparing the detector response for samples of Michel electrons, Americium Beryllium neutrons, and through-going muons. The analysis finds average neutron yields of {$\bar{n}_{\mathrm{data}} (\mathrm{beam}) = (0.272 \pm 0.010_{\mathrm{stat}})$} for an inclusive set of all identified muon neutrino candidates and {$\bar{n}_{\mathrm{data}} (\mathrm{beam,FV}) = (0.287 \pm 0.044_{\mathrm{stat}})$ for interactions which happened inside of the Fiducial Volume of ANNIE, which was optimized to increase the neutron detection acceptance. The presented neutron multiplicity values represent the number of detected neutrons after all event selection cuts and are not yet corrected for the neutron detection efficiency. An equivalent analysis on a simulated beam sample predicts neutron yields of $\bar{n}_{\mathrm{MC}}(\mathrm{beam}) = (0.515 \pm 0.0 07_{\mathrm{stat}})$ and $\bar{n}_{\mathrm{MC}}(\mathrm{beam,FV}) = (0.627 \pm 0.031_{\mathrm{stat}})$, indicating that the models tend to overpredict the number of neutrons produced in such interactions. Systematic errors have been briefly considered to contribute {$\sigma_{\mathrm{sys,FMV}} \sim 0.01\,$neutrons/$\nu$-interaction} due to the slight FMV inefficiency and {$\sigma_{\mathrm{sys,n}} \sim 0.05\,$neutrons/$\nu$-interaction} due to the neutron detection efficiency. Simulation studies further highlighted the importance of neutron detection in Diffuse Supernova Background (DSNB) searches. A combination of neutron tagging and Convolutional Neural Networks was found to reduce the most relevant Neutral Current Quasi-Elastic (NCQE) interaction background below the signal level, achieving a Signal-to-Background ratio of 4:1. In a further study, we investigated the positive impact of a deployment of a WbLS target on the energy reconstruction in ANNIE. WbLS provides a scintillation signal from hadronic recoils in addition to the charged lepton that can be included in neutrino energy reconstruction. It was found that a deployed WbLS volume in ANNIE improves the neutrino energy reconstruction from 14\% to 12\%, with the potential of going beyond this if more sophisticated reconstruction algorithms are developed in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feynman-α analysis using BGO gamma-ray detector in UTR-KINKI reactor

In conventional reactor noise measurement based on neutron detection, a neutron detector must be placed as close to a core as possible, to observe a largest possible correlation amplitude. For most of reactors other than critical assemblies, however, the placement is hardly possible. We focused on an alternative reactor noise measurement using prompt gamma-rays having a long flight range, to overcome the above constraint. A Feynman-α analysis using a NaI(Tl) scintillation detector was previously performed in UTR-KINKI, however, white noise originating from radioactivation of the scintillator significantly degraded the correlation amplitude. In this study, another Feynman-α analysis using a BGO gamma-ray detector, which never suffers from any radioactivation, is performed. A series of Feynman-α analyses for a critical state and several subcritical states of UTR-KINKI reactor has been carried out using two BGO detectors and a BF{sub 3} neutron detector to determine prompt-neutron decay constant. In the present analysis, the dead-time effect of these detectors and the delayed-neutron effect are considered. The prompt-neutron decay constant determined from Feynman-α analysis based on gamma-ray detection agrees with that from the analysis based on neutron detection. The Feynman-α analysis based on detecting gamma rays appears to be able to determine prompt-neutron decay constant at least as efficiently as the conventional analysis detecting neutrons.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First (p,n) reaction measurement in inverse kinematics with SECAR

Nucleosynthesis in the νp-process occurs in regions of slightly proton-rich nuclei in the neutrino-driven wind of core-collapse supernovae. The process proceeds via a sequence of (p,γ) and (n,p) reactions, and depending on the conditions, may produce elements between Ni and Sn. Recent studies show that a few key (n,p) reactions regulate the efficiency of the neutrino-p process (νp-process). We performed a study of one of such (n,p) reactions via the measurement of the reverse (p,n) in inverse kinematics with SECAR at NSCL/FRIB.Such proton-induced reaction measurements are particularly challenging, as the recoils and the unreacted projectiles have nearly identical masses. An appropriate separation level can be achieved with SECAR, and along with the incoincidence detection of neutrons these measurements become attainable. The preparation of the SECAR system for accommodating its first (p,n) reaction measurement, including the development of alternative ion beam optics, and the setup of the in-coincidence neutron detection, along with discussion on preliminary results from the p(58Fe,n)58Co reaction measurement are presented and discussed.

Tsintari, P↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Direct Neutron Conversion and Detection Processes

Commercial and laboratory neutron detection systems use indirect neutron response of materials like pressurized helium-3 (via nuclear reaction 3He(n, p)3H) to measure and count neutrons emanating from a source. Recently a host of semiconductors, especially a ternary semiconductor of lithium indium diselenide (6LiInSe2) and a quaternary alloy of enriched lithium-6, indium, phosphorous, and selenium (6LiInP2Se6), have shown promising neutron counting possibilities by directly converting neutrons into charge-carrying elements within the body of the semiconductor. These semiconductors have high thermal neutron capture cross sections, suitable energy bandgaps (~2.0 electron volts) for room-temperature operations, and a favorable electronic band structure for efficient electron charge transport. The article examines the semiconductor properties of these compounds in terms of their neutron counting capabilities and possible ways to extract neutron energy information from them. Lithium-6 and boron-10 (with thermal neutron absorption cross sections of 938 ± 6 and 3855 ± 26 barns, respectively) produce charged particles to be measured via indirect neutron interactions. The efficiency of indirect conversion neutron detectors is limited because of the inefficiencies in conversion mechanism. In case of direct conversion, the neutrons create charged particles in a single material for neutron capture and charge collection, increasing detection efficiency. Unlike 3He proportional counters, which provide no neutron energy information, the semiconductors can be used as neutron energy spectrometer. Fully resolved neutron energy by 6LiInP2Se6 from a plutonium-beryllium source has been reported in the literature. We will discuss the influence of these multilayered semiconductors’ crystallographic structures and growth techniques on neutron energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigations of radiation damaged arranged scintillating particle composites

Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.

36 MATERIALS SCIENCE↗

Scintillator Manufacture

This paper will be a literature review of composite scintillators, and their applications in neutron detection. Due to the shortage of 3 He, the traditional medium for neutron detection, new materials need to be explored for this purpose. Composite scintillating particle materials can serve as a solution to replace 3 He, offering faster response times, and all-solid-state form factors for diversified applications in the field. This project will include manufacturing Europium (Eu) and Sodium (Na) doped LiCaAlF 6 (LiCAF) scintillating particles for neutron detection.

36 MATERIALS SCIENCE↗