Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microchannel plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Further investigation of CsI-coated microchannel plate quantum efficiencies

Previously, pulse-counting detection efficiencies measured for CsI-coated microchannel plate (MCP) detectors (two-stage chevron configuration with a single collecting anode) have been reported to be 15-20 percent near Lyman-alpha (1216 A), compared to typical 65 percent quantum yields of opaque CsI photocathodes. To investigate the possibility that an improvement in quantum yield could result from use of MCPs with a bias angle of about 25 deg instead of 8 deg as used previously, the previous measurements were reported with new MCPs having the larger bias angle. No significant improvement in detection efficiency was achieved; the new detector tests still yielded maximum efficiencies of the order of 20 percent near 1216 A.

Carruthers, George R.↗

Performance of low resistance microchannel plate stacks

Results are presented from an evaluation of three sets of low resistance microchannel plate (MCP) stacks; the tests encompassed gain, pulse-height distribution, background rate, event rate capacity as a function of illuminated area, and performance changes due to high temperature bakeout and high flux UV scrub. The MCPs are found to heat up, requiring from minutes to hours to reach stabilization. The event rate is strongly dependent on the size of the area being illuminated, with larger areas experiencing a gain drop onset at lower rates than smaller areas.

Siegmund, O. H. W.↗

High resolution, two-dimensional imaging, microchannel plate detector for use on a sounding rocket experiment

We discuss a high resolution microchannel plate (MCP) imaging detector to be used in measurements of Doppler-shifted hydrogen Lyman-alpha line emission from Jupiter and the interplanetary medium. The detector is housed in a vacuum-tight stainless steel cylinder (to provide shielding from magnetic fields) with a MgF2 window. Operating at nominal voltage, the four plate configuration provides a gain of 1.2 x 10 exp 7 electrons per incident photon. The wedge-and-strip anode has two-dimensional imaging capabilities, with a resolution of 40 microns FWHM over a one centimeter diameter area. The detector has a high quantum efficiency while retaining a low background rate. A KBr photocathode is used to enhance the quantum efficiency of the bare MCPs to a value of 35 percent at Lyman-alpha.

Bush, Brett C.↗

Rocket-borne instrument with a high-resolution microchannel plate detector for planetary UV spectroscopy

A telescope-spectrograph employing a photon-counting microchannel plate (MCP)-CODACON detector has been built, tested, and flown on a sounding rocket. The detector uses a curved-channel MCP proximity focused onto a coded anode array of 1024 channels spaced 25.4-mm center to center. High quantum efficiency is obtained by depositing a cesium iodide photocathode on the front surface of the MCP. The instrument has obtained an ultraviolet spectrum of Jupiter with a spectral resolution of 8 A, which is higher than that of any previously reported observation in this wavelength range.

Mcclintock, W. E.↗

Background events in microchannel plates

Measurements have been made to assess the characteristics and origins of background events in microchannel plates (MCPs). An overall background rate of about 0.4 events/sq cm persec has been achieved consistently for MCPs that have been baked and scrubbed. The temperature and gain of the MCPs are found to have no significant effect on the background rate. Detection of 1.46-MeV gamma rays from the MCP glass confirms the presence of K-40, with a concentration of 0.0007 percent, in MCP glass. It is shown that beta decay from K-40 is sufficient to cause the background rate and spectrum observed. Anticoincidence measurements indicate the the background rate caused by cosmic ray interactions is small (less than 0.016 events/sq cm per sec).

Siegmund, O. H. W.↗

A high resolution delay line readout for microchannel plates

Investigations are reported of delay line configurations used to encode photon event locations in microchannel plate (MCP) detectors. Several delay line schemes of planar and multilayer structure are discussed. The importance of the delay line substrate material is examined, and it is shown that the raw signals from delay lines are narrow (about 3-4 ns FWHM). The factors determining the delay line resolution are evaluated, and it is demonstrated that these are in agreement with measurements. Resolutions of about 18-micron FWHM have been achieved. Measurements of the linearity of the delay line readout show that event centroid locations deviate from perfect linearity by less than 50 microns, even with the very simple anode fabrication methods employed. The image stability has also been evaluated and it is shown that image shifts are less than one resolution element over a period of two months.

Siegmund, O. S. W.↗

X-ray focusing using microchannel plates

We present measurements of the X-ray focusing properties of square-pore microchannel plates (MCP's). Square-pore MCP's contain large numbers of closely packed optical surfaces, as required for grazing incidence X-ray optics. The surface of individual MCP channels has been measured and found to have high microroughness transverse to the channel axis and low microroughness parallel to the axis. The high frequency transverse roughness, on length scales greater than 400 nm, has a rms value of 5.9 nm and a Gaussian autocorrelation function with correlation length of 1.41 micron. We find that the geometric misalignments of the surfaces of different channels limit the angular resolution obtainable with current samples of MCP's to 7.1 arcmin.

Kaaret, P.↗

Electronic readout systems for microchannel plates

The modes of operation of position-sensitive electronic readout systems which use high-gain microchannel plate (MCP) electron multipliers are described, and their performance characteristics, along with those of the MCP, are compared. Among the structures presented are the wedge-and-strip, Codacon, and multilayer coincidence-anode MAMA (Multimode Microchannel Array) arrays. Spatial resolution of 25 x 25 sq microns (coincidence anode arrays) is achieved with an array format of 256 x 1024 pixels. On the basis of the performance data it is concluded that the readout systems using only conducting electrodes offer the best performance characteristics.

Timothy, J. G.↗

Charge coupled devices vs. microchannel plates in the extreme and far ultraviolet - A comparison based on the latest laboratory measurements

While microchannel plates (MCPs) have been established as imaging photon counters in the EUV and FUV for some years, CCDs are associated with low light level sensing at visible and near-IR wavelengths. Attention is presently given to recent proposals for CCDs' use as EUV and FUV detectors with quantum efficiencies sometimes exceeding those of MCPs; quantum resolution, format size, dynamic range, and long-term stability are also used as bases of comparison, for the cases of both space-based astronomical and spectroscopic applications.

Vallerga, J.↗

Microchannel plate EUV detectors for the Extreme Ultraviolet Explorer

The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. It is shown that this detector has achieved high position resolution performance (greater than 512 x 512 pixels) and has low (less than one percent) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (less than 40 percent FWHM) for UV radiation and displays low (less than 0.2 cnt/sq cm-s) dark background counting rates. Work that has been done on EUV filters in relation to the envisaged filter and photocathode complement is also described.

Siegmund, O. H. W.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

Low-Noise, Long-Life, High-Gain Microchannel-Plate Glass

Dark noise reduced substantially without degrading other properties. Glass suitable for use as active material for microchannel plates (MCP's) free of constituents including significant amounts of radioactive isotopes.

Feller, W. Bruce↗

Preliminary results with saturable microchannel array plates

Microchannel array plates with a performance comparable to that of a conventional channel electron multiplier have been obtained for the first time. These array plates employ an angled electrostatic field to inhibit the feedback of positive ions within the microchannels. Saturated output pulse height distributions with modal gain values in excess of 10 million have been obtained and stable operation demonstrated over a range of ambient pressures from 0.0000001 to 0.00008 torr. However, a time-dependent reduction in the gain has been observed with these experimental plates because of the accumulation of charge on the insulating strips which are inserted in the wall of the microchannel to establish the angled electrostatic field.

Timothy, J. G.↗

A Study of the Gain of Microchannel Plates in the Ionization Profile Monitors at Fermilab

One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically, the assumption has been that this is aging, where the secondary emission yield (SEY) of the pore surface changes after some amount of extracted charge. Recent literature searches have brought to light the possibility that this is an initial ‘scrubbing’ effect whereby adsorbed gasses are removed from the MCP pores by the removal of charge from the MCP. This paper discusses the results of studies conducted on the IPMs in the Main Injector at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultraviolet quantum detection efficiency of potassium bromide as an opaque photocathode applied to microchannel plates

The quantum detection efficiency (QDE) of potassium bromide as a photocathode applied directly to the surface of a microchannel plate over the 250-1600 A wavelength range has been measured. The contributions of the photocathode material in the channels and on the interchannel web to the QDE have been determined. Two broad peaks in the QDE centered at about 450 and about 1050 A are apparent, the former with about 50 percent peak QDE and the latter with about 40 percent peak QDE. The photoelectric threshold is observed at about 1600 A, and there is a narrow QDE minimum at about 750 A which correlates with 2X the band gap energy for KBr. The angular variation of the QDE from 0 to 40 deg to the channnel axis has also been examined. The stability of Kbr with time is shown to be good with no significant degradation of QDE at wavelengths below 1216 A over a 15-day period in air.

Siegmund, Oswald H. W.↗

Microchannel plate modal gain variations with temperature

Measurements of the modal gain of two high-gain curved-channel microchannel plates (MCPs) at various operating temperatures are presented. Both MCPs were fabricated from the Long Life glass with 12-micron diam channels on 15-micron centers. The modal gain was found to decrease with increasing temperature at a rate of -0.1 percent C. This reduction of gain with temperature is attributed primarily to an axial temperature gradient along each MCP channel creating a nonuniform electric field within the channel that lowers the effective output gain. A lowering of the secondary electron yield resulting from increased phonon scattering of secondary electrons released within the walls of the MCP channels was assessed, but was found to have a negligible contribution to the drop in gain with temperature.

Slater, David C.↗

A Study of the Gain of Microchannel Plates in the Ionization Profile Monitors at Fermilab

One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically, the assumption has been that this is aging, where the secondary emission yield (SEY) of the pore surface changes after some amount of extracted charge. Recent literature searches have brought to light the possibility that this is an initial 'scrubbing' effect whereby adsorbed gasses are removed from the MCP pores by the removal of charge from the MCP. This paper discusses the results of studies conducted on the IPMs in the Main Injector at Fermilab.

43 PARTICLE ACCELERATORS↗

Flat field response of the microchannel plate detectors used on the Extreme Ultraviolet Explorer

The results of the extreme ultraviolet (EUV) flat field calibrations of two of the flight detectors to be flown on the Extreme Ultraviolet Explorer Satellite (EUVE) are presented. Images of about 40 million detected events binned 512 by 512 are sufficient to show microchannel plate fixed pattern noise such as hexagonal microchannel multifiber bundle interfaces, 'dead' spots, edge distortion, and differential nonlinearity. Differences due to photocathode material and dependencies on EUV wavelength are also described. Over large spatial scales, the detector response is flat to better than 10 percent of the mean response, but, at spatial scales less than 1 mm, the variations from the mean can be as large as 20 percent.

Vallerga, J. V.↗