Background events in microchannel plates

Abstract

Measurements have been made to assess the characteristics and origins of background events in microchannel plates (MCPs). An overall background rate of about 0.4 events/sq cm persec has been achieved consistently for MCPs that have been baked and scrubbed. The temperature and gain of the MCPs are found to have no significant effect on the background rate. Detection of 1.46-MeV gamma rays from the MCP glass confirms the presence of K-40, with a concentration of 0.0007 percent, in MCP glass. It is shown that beta decay from K-40 is sufficient to cause the background rate and spectrum observed. Anticoincidence measurements indicate the the background rate caused by cosmic ray interactions is small (less than 0.016 events/sq cm per sec).

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Siegmund, O. H. W., Vallerga, J., Wargelin, B.. 1988-02-01. Background events in microchannel plates. https://ntrs.nasa.gov/citations/19880055010