Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, previous synchronization analysis for heterogeneous systems requires the machines to satisfy certain proportionality property. In our approach, the effective transfer functions for each cluster can be tuned by the IBRs to satisfy such property, enabling us to apply the shaping control to systems with a wider range of heterogeneous machines.

frequency-shaping control↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

A Grid-Forming Split-Phase Three-Leg Inverter with Unbalanced Loading and Active Power Decoupling

This paper presents a split-phase three-leg inverter that regulates 180-degree phase-shifted AC voltages to support residential house loads under unbalanced loading conditions and decouples double line frequency power pulsation by utilizing the third half-bridge switching leg. The active power decoupling function is added without extra active switching components. The control feasibility and effectiveness are verified through MATLAB Simulink simulation and controller hardware-in-the-loop test.

Kim, Namwon [ORNL] (ORCID:0000000200438489)↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

Beam breakup instability studies of powerful energy recovery linac for experiments

The maximum achievable beam current in an energy recovery linac (ERL) is often constrained by beam breakup (BBU) instability. Our previous research highlighted that filling patterns have a substantial impact on BBU instabilities in multipass ERLs. In this study, we extend our investigation to the eight-cavity model of the Powerful ERL for Experiment (PERLE). We evaluate its requirements for damping cavity higher order modes (HOMs) and propose optimal filling patterns and bunch timing strategies. Our findings reveal a significant new insight: while filling patterns are crucial, the timing of bunches also plays a critical role in mitigating HOM beam loading and BBU instability. This previously underestimated factor is essential for effective BBU control. We estimated the PERLE threshold current using both analytical and numerical models, incorporating the designed PERLE HOM dampers. During manufacturing, HOM frequencies are expected to vary slightly. Our study found no significant difference in BBU suppression for relative rms frequency jitters of 0.001, 0.002, and 0.005 for the same HOM. Introducing a jitter of 0.001 into our models, we found that the dampers effectively suppressed BBU instability, achieving a threshold current an order of magnitude higher than the design requirement. Our results offer new insights into ERL BBU beam dynamics and have important implications for the design of future ERLs. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Control and Real-Time Simulation of Microgrids with EV Fast-Charging and Grid-Forming Resources

Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.

14 SOLAR ENERGY↗

Modeling, Validation, and Control of the IEA‐15 MW Reference Wind Turbine and VolturnUS‐S Platform

This paper presents the acausal modeling, validation, and control of floating offshore wind turbines (FOWTs). The model simulates the IEA‐15 MW reference turbine and the semi‐submersible VolturnUS‐S platform utilizing a Control‐oriented, Reconfigurable, and Acausal Floating Turbine Simulator (CRAFTS), which integrates the key coupled aero‐hydro‐elasto‐servo dynamics and is being developed by authors at the University of Central Florida. Verification and validation are conducted using numerical data from the industry‐standard simulation platform OpenFAST and experimental data from the Floating Offshore‐wind and Controls Advanced Laboratory (FOCAL) project, in which the authors were involved. Numerical results demonstrate the model's ability to qualitatively capture loads and responses across various load cases, highlighting the impact of the control system under different wind and wave conditions and opening new opportunities for optimizing FOWT designs. This paper provides wind turbine researchers with valuable insights into system characteristics, system frequencies, damping effects, and internal reaction forces, serving as a reference for future studies in FOWT modeling and control.

17 WIND ENERGY↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biconjugate Impedance Matching Control of the HERO WEC: Preprint

Effective control strategies are essential for maximizing the power output of wave energy converters (WECs). In this study, we explore the methodology of port-based modelling which can be used for bi-conjugate impedance matching, a type of reactive control that involves maximizing power transfer by setting the load (PTO) impedance to be the complex conjugate of the source impedance (WEC). Despite its foundational role in electrical engineering, this method has seen limited application in wave energy and has not yet been demonstrated in wave-powered desalination systems. We represent our complex multidisciplinary system as an equivalent circuit to explore frequency-based relations. The HERO WEC, a small-scale, modular point absorber (PA) designed for reverse osmosis desalination is used as a case study to demonstrate port-based modelling for control applications. Improving the performance of wave-powered water desalination systems could play a critical role in addressing freshwater scarcity for coastal communities, especially those in remote or disaster-prone regions.

16 TIDAL AND WAVE POWER↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Omega-Limit Sets and Input-To-State Stability in Power Grids with Switching Equilibria

This paper studies a power transmission system with both conventional generators (CGs) and distributed energy assets (DEAs) providing frequency control. We consider an operating condition with demand aggregating two dynamic components: one that switches between different values on a finite set, and one that varies smoothly over time. Such dynamic operating conditions may result from protection scheme activations, external cyber-attacks, or due to the integration of dynamic loads, such as data centers. Mathematically, the dynamics of the resulting system are captured by a system that switches between a finite number of vector fields - or modes -, with each mode having a distinct equilibrium point induced by the demand aggregation. To analyze the stability properties of the resulting switching system, we leverage tools from hybrid dynamic inclusions and the concept of ..omega.. -limit sets from sets. Specifically, we characterize a compact set that is semi-globally practically asymptotically stable under the assumption that the switching frequency and load variation rate are sufficiently slow. For arbitrarily fast variations of the load, we use a level-set argument with multiple Lyapunov functions to establish input-to-state stability of a larger set and with respect to the rate of change of the loads. The theoretical results are illustrated via numerical simulations on the IEEE 39-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Response Improvement in a Standalone Small Hydropower Plant Using Battery Storage

This paper proposes a control architecture for frequency, current, and voltage control that facilitates using battery storage to improve the response of standalone small hydropower plants. The frequency controller uses rate-of-change of frequency and frequency-Watt-based generations to produce active power commands. The distinctive feature of the controller design is that it nicely integrates response to frequency change with constraints on frequency and state of battery to enable power injections. The current and voltage control scheme allows incorporating the frequency controller. The distinctive feature of this controller is that it incorporates a bounded integral control strategy that guarantees stability. Results on the stability of the hydropower plant with proposed scheme are presented and robust ways to choose the controller gains are investigated via root locus analysis. In conclusion, simulations performed show that: the hydropower plant response is significantly improved with battery storage using the proposed scheme; the load carrying capability of the hydropower plant is significantly improved with battery storage; the proposed scheme has the capability to recharge the battery; and the proposed control scheme gives improved performance.

13 HYDRO ENERGY↗