Guidelines for the development of a lunar sample preparation system
Sample preparation for X-ray diffractometer and guidelines for sample selection and handling of lunar rock specimens for analysis
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Sample preparation for X-ray diffractometer and guidelines for sample selection and handling of lunar rock specimens for analysis
Acquisition and transport components of X-ray diffractometer sampler breadboard
Feasibility of total iron analysis by X-ray fluorescence detection in X-ray diffractometer
SNAP is a neutron time-of-flight diffractometer at the Spallation Neutron Source operated by Oak Ridge National Laboratory. It generates large arrays of neutron detection events that encode the crystalline atomic structure of materials under study. SNAPRed is an application that makes these datasets accessible to end users by orchestrating the process of data reduction while automatically managing the variable neutron instrumentation configuration. It supports arbitrary grouping and masking of individual detector pixels and includes custom-developed data compression approaches to accommodate the large volumes of data generated by the SNAP instrument.
The magnetostrictive response of a Terfenol-D pellet was measured via a laboratory-based X-ray diffractometer. X-ray diffraction patterns were collected from the pellet sample with and without the presence of an applied magnetic field (~30 mT) generated by placing a large magnet under the pellet. A standard reference material, Silicon 640c, was employed as an internal standard. Magnetostriction values of 323 and 227 ppm Δl/l were determined for the (104) and (110) indexed peaks, respectively, assuming a rhombohedral structure for Terfenol-D. A threshold noise level value of ~20 to 30 ppm Δl/l was suggested based on before/after measurements in the absence of the applied field. No clear evidence of domain wall rotation was detected via changes in relative intensities of diffraction peaks in the presence of the applied magnetic field.
Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.
Executing experimental tasks in both normal research laboratories and large-scale scientific facilities often requires extensive human supervision and remains a key challenge on the path to fully autonomous, artificial intelligence (AI)-driven science. Here we demonstrate a large language model-driven agent that autonomously performs X-ray sample alignment on a synchrotron beamline by planning actions, executing instrumental commands, interpreting observations and iterating towards experimental goals. Based on existing large language models with structured tool-use via the model context protocol, our AI X-ray scientist was guided and tested using an in-house-built virtual experimental setup that mirrors a six-circle diffractometer at an operational synchrotron beamline. The agentic workflow developed in the virtual environment was directly deployed on a real beamline, where it correctly identified reference reflections and determined the orientation matrix, an essential first step in any type of single-crystal scattering experiment. Our AI X-ray scientist responded effectively to unexpected experimental conditions, demonstrating adaptive problem-solving and readiness for addressing practical experimental situations. Our study provides a step towards autonomous operation across diverse experimental environments at large-scale scattering facilities.
Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.
Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.
Neutron diffraction is a powerful tool in the study of quantum materials and associated emergent phenomena as it allows for direct detection of magnetic structure even at ultra-low temperatures. As pressure can drive systems across quantum critical points and tune emergent behaviors at the quantum scale, coupling neutron diffraction with extreme conditions of high pressure at (ultra-)low temperatures has been a key research target over decades. This has proven challenging as magnetic neutron diffraction typically requires large sample volumes due to flux limitations, whereas high-pressure studies require small sample volumes due to pressure limitations. Combining these two contradictory requirements poses many difficulties, but also brings opportunities in research and development. Here, we address these shortcomings through the use of a diamond anvil cell equipped with polycrystalline anvils with relatively large sample volumes coupled with the high neutron flux made available by the high-pressure diffractometer of the Spallation Neutron Source. This particular diamond anvil cell configuration has previously proven useful for single-crystal samples and is here coupled with the ultra-low temperatures of a dilution refrigerator for the first time. Our study on a single crystal of Yb 2 O 3 successfully collected magnetic neutron diffraction data at 5.3 GPa below 200 mK inside a dilution refrigerator. We have performed a detailed analysis of the magnetic diffraction data to investigate the magnetic structure under pressure and observed a subtle shift in the transition temperature. This development will open the door for future studies on magnetic materials with these much-desired coupled extremes of high pressure and ultra-low temperatures.
The tunability of Dirac semimetals with antiferromagnetic Mn layers is of great interest. The observed sign change of interlayer magnetic coupling between CaMnBi 2 and SrMnBi 2 suggests ionic substitution as a potential tuning mechanism. If so, novel behavior near the compensation point could be expected. Here, to explore this, we study a mixed-cation analog, Ca 0.6 Sr 0.4 MnSb 2 , where Bi is replaced by Sb. Conventional inelastic neutron scattering is impractical due to the small crystal size (m ≈ 0.28 g) available for compositional studies; however, we find that using a neutron diffractometer with a wide-angle area detector we can obtain a good quality spin-wave signal, which is shaped by energy-momentum conservation and retains spectroscopic information even without direct energy analysis. Spin-wave modeling reveals an interlayer coupling quantitatively similar to SrMnSb 2 , indicating it is not directly tuned by ionic size and that the sign change in Bi-based compounds likely arises from the observed change in lattice symmetry. Beyond this key insight, our results present an efficient method for parametric and compositional studies of spin dynamics in small crystals.
In the refinement of the crystal structures of ice, the best results obtained so far have been with neutron diffraction because the most troublemaking aspects are the hydrogen atoms. In nine out of twenty ice structures, the hydrogen atoms are disordered, which makes proper refinement more difficult. In our previous paper describing the structure of ice VI we proved that, using Hirshfeld atom refinement (HAR) based on synchrotron X-ray data, it is possible to obtain results comparable with those from neutron experiments. In this work, we investigate another structure of high-pressure disordered ice, cubo-ice (ice VII). Single crystals of cubo-ice were grown under pressure in diamond anvil cells. X-ray diffraction measurements were conducted at a synchrotron source facility (APS, University of Chicago, USA) as well as on our regular in-house laboratory diffractometer with Ag radiation. The data collected were further refined with HAR. Comparison of the structural parameters obtained with those derived from neutron diffraction showed very good agreement in terms of bond lengths and fairly good agreement in terms of hydrogen atom ADPs. We were also able to perform unconstrained refinements with various split-atom models.
Due to their potential applications in low-power consumption and/or multistate memory devices, multiferroic materials have attracted a lot of attention in the condensed matter community. As part of the effort to identify new multiferroic compounds, perovskite-based GdCrO 3 was studied in both bulk and thin film samples. A strong enhancement of the capacitance in a field suggested ferroelectric behaviour but significant leakage and no well developed P–E hysteresis loops were observed. Measurements clearly indicate the existence of a polar phase but only below 2 K (likely connected to Gd ordering). Here the determination of the magnetic structure through neutron diffraction collected on an isotopic 160 GdCrO 3 sample at the WISH diffractometer at ISIS is reported. The presence of three successive magnetic phases as a function of temperature (commensurate, spin re-orientation and incommensurate phases once the Gd order), previously only seen by magnetization, is confirmed. Using the most recent guidelines for reporting the determined structures, we highlight the benefits of using such nomenclature for discussing physical properties and consider possible mechanisms and couplings that led this seemingly rather isotropic system to display the complex structures observed.
Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.
High pressure data collected from polycrystalline isotopically enriched 7Li2CO3 using the Paris-Edinburgh press on the SNAP diffractometer. Single toroidal cBN anvils were used with a TiZr gasket. The sample was measured with and without a pressure medium.
Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.
High flux neutron beam and high efficiency detectors warrant quick turn arounds of neutron diffraction measurements at the engineering materials diffractometer VULCAN. Efficient change and alignment of samples and automatic measurements at VULCAN are desired for better use of neutron beam time by users. In this work, we aim to develop a proof-of-concept Robotic Interactive Control & Handling System (RICH) for sample handling at VULCAN that could assist high throughput experiments and reduce the overhead time significantly. This was realized by a six-axis desktop robot with trained AI models. The trained AI models can recognize and locate samples in various types of positions in a live video stream. In addition, we developed smart algorithms which used our models on multiple cameras to recognize where samples are with respect to multiple point of views, and then using user-inputted parameters, align them to perform complex measurements.
Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.