Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voltage Magnitude”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Deep Learning Approach for In-Network Synchrophasor Missing Data Recovery Using Programmable Network Switches

Phasor measurement unit (PMU) networks deliver accurate and timely measurements, which is essential for managing today’s electric power systems. To ensure data quality and enhance the cyber-resilience of PMU networks against malicious attacks and data errors, this study presents an online PMU missing data recovery scheme by leveraging P4 programmable switches. The data plane incorporates a customized PMU protocol parser that abstracts the necessary payload data for recovery. Recovery processes are executed in the control plane using a pre-trained machine learning model. Both traditional and advanced ML models, such as transformer and TimeGPT, are explicitly employed for data prediction. This approach ensures rapid and precise data recovery. Performance evaluations focus on recovery speed and accuracy, using a real dataset from a campus microgrid. With 20% missing PMU data, the mean absolute percentage error for voltage magnitude is 0.0384%, and the phase angle error discrepancy is approximately 0.4064%.

Phasor Measurement Unit, Machine Learning, Program↗

Joint Estimation of Topology and Injection Statistics in Distribution Grids with Missing Nodes

Optimal operation of distribution grid resources relies on accurate estimation of its state and topology. Practical estimation of such quantities is complicated by the limited presence of real-time meters. This article discusses a theoretical framework to jointly estimate the operational topology and statistics of injections in radial distribution grids under limited availability of nodal voltage measurements. In particular, we show that our proposed algorithms are able to provably learn the exact grid topology and injection statistics at all unobserved nodes as long as they are not adjacent. The algorithm design is based on novel ordered trends in voltage magnitude fluctuations at node groups, that are independently of interest for radial physical flow networks. The complexity of the designed algorithms is theoretically analyzed and their performance is validated using both linearized and nonlinear ac power flow samples in test distribution grids.

97 MATHEMATICS AND COMPUTING↗

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

Risk-Based Dispatch Bound Calculator

This calculator outputs time-varying lower and upper bounds (matrices), called dispatch bounds, for the controllable portions of the power injections at each node in a distribution network to guarantee that the voltage magnitudes stay within prescribed bounds with at least a given probability for any set of power injections that are within their dispatch bounds. The calculator is meant to be a tool for a central controller of a distribution network to set dispatch bounds for each node that allows each node to independently decide their actual power injection within their dispatch bound. The user can choose whether to assume the forecast errors of the uncontrollable power injections are gaussian or are worst-case (distributionally robust). The user can choose whether the dispatch bounds include the controllable reactive power or just the active power under a constant power factor assumption.

Comden, Joshua↗

Networked Microgrids Optimization

This project is mainly about the operation optimization of three networked microgrids (MG), including centralized optimization and distributed optimization. The alternating direction method of multipliers (ADMM) algorithm is used for distributed optimization. In the distribution network considered here, there is a Distribution Management system (DMS) as the system coordinator and several networked microgrids. In grid-connected mode, power could be imported or exported at the distribution substation bus according to the utility rate, and the exchanged power at point of common coupling (PCC) of any microgrid has a limitation. In islanded mode, the power imports/exports at the distribution substation are zero. In both grid-connected and islanded mode, the distribution substation is taken as a slack bus with fixed voltage magnitude.

Chen, Yang [Oak Ridge National Laboratory (ORNL), ↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain for Fault-Tolerant Grid Operations Version 2.0

This report explores the potential of distributed ledger technology (DLT) as a transformative tool to enhance fault-tolerant operations in electrical distribution systems. Leveraging DLT's core attributes, including an immutable decentralized ledger, distributed consensus mechanisms, and state replication capabilities, this study focuses on three critical use cases. A central aspect of this research centers on the utilization of a consensus-driven ledger, providing actors within the system, such as distributed resources, with access to a reliable data repository. This empowers these actors to collaborate effectively and make informed decisions, all securely recorded on the blockchain. The first use case concentrates on data configuration, utilizing mathematical criteria---particularly, the chi-squared test for gross error detection---to identify trustworthy sensors for advanced decision-making. Building upon this foundation of trust, the second use case, topology identification, accurately determines circuit breaker states, unveiling the distribution network's topology. Ultimately, the third use case leverages this trust to execute switching actions, reconfiguring feeders and restoring power to disconnected customers after fault events. The concept of trust serves as a cornerstone in this approach, marking a departure from traditional fault location, isolation, and service restoration (FLISR) methods. Additionally, the blockchain-based architecture introduces decentralization, empowering disconnected areas to make autonomous decisions, even when communication with a central control center is disrupted. The primary contributions of this report are twofold: (1) a novel approach for evaluating distribution system voltage areas while preserving data ownership and (2) the implementation of interactions between distribution network areas using the actor model. Unlike the previous sequential approach for evaluating the area connection voltages, which required a radial network topology, this study's area model reduction enables a more versatile approach. The area model reduction addresses issues of prolonged data waiting times and multiple points of failure within the previous approach. Notably, the presented evaluation for the reduced network model area connection reveals a significant increase in the differences in voltage magnitudes. Simulation and evaluation of area agents across four distinct cases elucidate the area-level interaction behavior during a fault event. Simulations demonstrate that the proposed distributed FLISR (DFLISR) approach can successfully restore service to an affected area. Varying message delays and message loss probabilities in each simulation case underscore their impacts on restoration times, ranging from 3 min and 32 s to 6 min and 19 s. In contrast, power is not restored in an area in one of our simulation cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Apex Study: Compensating Transient Beam Loading in the RHIC 28 MHZ

With the EIC on the way, it is important that developments and strategies are in place to deal with the very high beam currents that the machine will feature. Specifically, the EIC will collide beams of up to 2.5 A, three times the beam current in RHIC. This higher beam current will cause significant voltage transients in the cavity fields which can lead to longitudinal instabilities and beam loss. In anticipation of these negative effects, studies were carried out on the RHIC 28 MHz cavities using newly developed firmware and software to diagnose and combat beam loading. Diagnostic tools such as the bunch-by-bunch (BbyB) ADC firmware and digital network analyzer (DNA) were used to characterize the closed loop system and transient on the cavity voltage magnitude and phase. Then, a one-turn delay feedback (OTFB) and adaptive feed-forward (aFFWD) were used to minimize the transient beam loading. The studies were carried out with beam during 2 accelerator physics experiements (APEXs) using one of the 28 MHz accelerating cavities here at RHIC.

43 PARTICLE ACCELERATORS↗

Secure Control Regions for Distributed Stochastic Systems with Application to Distributed Energy Resource Dispatch

With the increasing connectedness and interdependence of systems that are stochastic in nature, the issue of how to manage and coordinate them for safe operation has evidently become more important. In many networked system architectures, the system-wide output must be delicately managed, often within a prescribed set of bounds. In this paper, a novel control framework is proposed where the bounds on the outputs are translated into independent bounds on the controllable inputs of each subsystem. The main benefit of this framework is that respecting the individual control bounds suffices to guarantee that the system-wide outputs will remain within safe boundaries. Because the systems are assumed to be stochastic, the bounds on the output are introduced as probabilistic chance constraints. The benefits of this framework are demonstrated by applying it to the control of distributed energy resources in a distribution network where the main goal is to keep the voltage magnitudes within their prescribed bounds. The control bounds are evaluated using real data on an IEEE test system.

chance constrained optimization↗

Power System Network Reduction for Power Hardware-in-the-Loop Simulation: Preprint

This paper proposes a single-port equivalent and a two-port equivalent to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port remain unchanged over the reduction, including voltage magnitude and phase, active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Network Reduction for Power Hardware-in-the-Loop (PHIL) Simulation

This paper proposes single-port equivalent and two-port equivalent network reduction methods to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port(s) remain unchanged over the reduction, including voltage magnitude and phase and active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Secure Control Regions for Distributed Stochastic Systems with Application to Distributed Energy Resource Dispatch: Preprint

With the increasing connectedness and interdependence of systems that are stochastic in nature, the issue of how to manage and coordinate them for safe operation has evidently become more important. In many networked system architectures, the system-wide output has to be delicately managed; often within a prescribed set of bounds. In this paper, a novel control framework is proposed where the bounds on the outputs are translated into independent bounds on the controllable inputs of each subsystem. The main benefit of this framework is that respecting the individual control bounds suffices to guarantee that the system-wide outputs will remain within safe boundaries. Since the systems are assumed to be stochastic, the bounds on the output are introduced as probabilistic chance constraints. The benefits of this framework are demonstrated by applying it to the control of distributed energy resources in a distribution networks where main goal is to keep the voltage magnitudes with their prescribed bounds. The control bounds are evaluated using real data on an IEEE test system.

chance constrained optimization↗

Hierarchical distributed voltage regulation

Embodiments of the disclosure provide for hierarchically distributed voltage regulation and power flow optimization in a power distribution network. According to one embodiment, a regional coordinator system may determine power flow for an autonomous grid (AG) representing a portion of the distribution network based on a set of voltage parameters from nodes in the AG. The set of voltage parameters my include a current voltage magnitude. The regional coordinator system may provide, to a central controller system of the distribution network, one or more power flow parameters based on the determined power flow for the AG.

Zhou, Xinyang↗

Tunable doping of carbon nanotubes through engineered atomic layer deposition

A carbon nanotube field effect transistor (CNFET), that has a channel formed of carbon nanotubes (CNTs), includes a layered deposit of a nonstoichiometric doping oxide (NDO), such as HfOX, where the concentration of the NDO varies through the thickness of the layer(s). An n-type metal-oxide semiconductor (NMOS) CNFET made in this manner can achieve similar ON-current, OFF-current, and/or threshold voltage magnitudes to a corresponding p-type metal-oxide semiconductor (PMOS) CNFET. Such an NMOS and PMOS can be used to achieve a symmetric complementary metal-oxide semiconductor (CMOS) CNFET design.

Source record↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Real-World 20-Hz IBR Subsynchronous Oscillations: Signatures and Mechanism Analysis

This article provides analyses of subsynchronous oscillations associated with solar photovoltaics (PVs) observed in real world. All have oscillation frequencies at approximately 20 Hz in voltage and current magnitudes. On the other hand, in phase voltage and current, the oscillations show very different signatures. Through constructing simplified linear models and conducting sensitivity analysis, we are able to associate dynamic phenomena with the underlying mechanism and speculate the possible causes of the 20-Hz oscillations. The analysis results have all been validated via simulation results from electromagnetic transient (EMT) test beds constructed in MATLAB/Simscape.

inverter-based resources↗

Nanopores with dynamic pore opening diameter

Solid state nanopores have emerged as model systems for understanding transport properties on the nanoscale. They serve as templates for both preparing mimics of biological channels and designing biological sensors. Unlike their biological inspirations, the majority of nanopores prepared thus far, however, have been structurally static devices such that the pore opening diameter is fixed. If we could prepare nanopores whose opening diameter fluctuated in time with controlled amplitude at known locations in the pore, we could create ionic memristors as well as achieve new transport modes. Here we present ∼10 nm diameter single nanopores drilled through a 10 nm thick gold layer positioned on top of a 30 nm thick silicon nitride film. Two types of devices were prepared; one containing single stranded DNA and the other containing hairpin DNA attached to the discrete layer of gold using thiol chemistry. When an external electric field was applied across a nanopore with single stranded DNA, the nanoconfined DNA molecules exhibited steric and electrical constraints that led to memristor-like behavior in the current–voltage curves. The degree of hysteresis was controlled by salt concentration, magnitude of voltage and pore diameter. In contrast, nanopores containing DNA hairpins conducted similar currents in forward and reverse bias in agreement with the rigidity of the hairpin molecule. The experiments are explained by Brownian dynamics simulations that reveal voltage and salt concentration induced changes in DNA extension. The degree of DNA extension was also found to be dependent on the location of the molecules along the pore axis. The nanopores presented here provide the first steps towards preparation of non-equilibrium nanopore systems.

Vlassiouk, Ivan [ORNL] (ORCID:0000000254940386)↗

Power Module Precursors and Prognostics

The ongoing work involves 1) the identification and evaluation of various electric signals as indicators to module failure and precursors to aging, and 2) the development of corresponding detection techniques. In the current phase, 1) the increase of on-state resistance is selected as the precursor to the power cycle aging of silicon carbide power MOSFET modules based on review and rest data. 2) A detection method leveraging the gate voltage fluctuations magnitude during commutation transients to inform the on-state resistance increase is investigated which has the benefit of being able to be integrated into the gate driver. A dedicated detection circuit for implementation is designed and simulated and is currently in fabrication.

ADVANCED PROPULSION SYSTEMS↗