Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plasma devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Transport from electron-scale turbulence in toroidal magnetic confinement devices

Plasma transport driven by turbulence ultimately determines the energy confinement performance of controlled fusion devices regardless of their confinement schemes and configurations. A large variety of plasma instabilities have been proposed for driving turbulence responsible for anomalous plasma transport beyond classical/neoclassical transport due to collisions. Although ion-scale turbulence usually dominates due to its large eddy size and saturation level, electron-scale turbulence has been recognized to be important in regions where ion-scale turbulence is suppressed (e.g., in internal transport barrier and in spherical tokamak H-mode plasmas) or is close to marginality. Electron-scale turbulence has been shown to nonlinearly interact with ion-scale turbulence, which modifies the dynamics of both and affects the resulting plasma transport, particularly when ion-scale instability is weakly driven. In this review paper, we focus on electron-scale turbulence that is believed to operate in magnetically confinement fusion devices and aim to provide a review of theoretical, numerical, and experimental developments in understanding electron-scale turbulence and its role in driving anomalous plasma turbulence. In particular, we focus on the electrostatic electron temperature gradient (ETG) mode which is the most widely recognized plasma instability underlying electron-scale turbulence observed in magnetically confined plasmas. Finally, we note that there are other less studied instabilities that might be responsible for observed electron-scale turbulence, most notably ubiquitous mode, and short-wavelength ion temperature gradient (SWITG) mode, which will be briefly touched on in this review.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inverse Design of Plasma Metamaterial Devices for Optical Computing

We apply inverse-design methods to produce two-dimensional plasma metamaterial (PMM) devices. Backpropagated finite-difference frequency-domain (FDFD) simulations are used to design waveguides and demultiplexers operating under both TE and TM modes. Demultiplexing and waveguiding are demonstrated for devices composed of plasma elements with reasonable plasma densities of approximately 7 GHz, allowing for future in situ training and experimental realization of these designs. We also explore the possible applicability of PMMs to nonlinear boolean operations for use in optical computing. Functionally complete logical connectives (or and and) are achieved in the TM mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Photonics for the Control of Kilojoule Lasers

The main goal of this project was to develop plasma photonic devices (plasma lenses or ellipsoidal plasma mirrors (EPMs)) for controlling the focus of high-energy (kJ-class) laser systems. In order to defocus a kJclass laser beam, a plasma optic must produce a very specific plasma density profile. For a plasma lens, this profile must be peaked on axis and fall off parabolicly with radius. We developed four plasma-lens target designs that were predicted to yield the ideal plasma profile required for defocusing kJ-class laser beams. Particle-in-cell (PIC) simulations using the code OSIRIS were used to explore the design. The resulting plasma lens must also be underdense, which sets an upper limit on the solid density of the plasma-lens targets to ~ 1 mg/cm 3 or less. This low of a density is highly challenging to fabricate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RF sheath induced sputtering on Proto-MPEX. I. Sheath equivalent dielectric layer for modeling the RF sheath

The pulsed linear plasma device Prototype Material Plasma Exposure eXperiment (Proto-MPEX) uses a radio frequency (RF) helicon antenna with an aluminum nitride ceramic window for plasma production. The RF sheath created under the helicon antenna is sufficient to cause ion impact energies to be greater than the sputtering threshold of the AlN helicon window material and for impurities to be created. In this study, we investigate the RF sheath on the inner diameter of the helicon window and its impact on the impurity production rates in Proto-MPEX. Three models—a 3D COMSOL finite element RF model of the Proto-MPEX helicon region, a rectified DC sheath potential model, and the 3D Global Impurity TRansport code—are coupled together to study impurity production and transportation. This novel method of impurity generation and transport modeling spans length scales ranging from the sheath (millimeters or less) up to the full device (meters) and can be applied to other radio frequency sources and antennas in a wide range of plasma physics studies, including basic plasmas, low-temperature processing plasmas, plasma thrusters, and fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the materials analysis and particle probe for Proto-MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being used in plasma source research and development (R&D) for the proposed MPEX. Once the R&D is completed, this device can also be used to perform plasma–material interaction studies. To perform these studies, a new materials analysis and particle probe (MAPP) has been constructed. The MAPP’s components are a sample holder and manipulator and a custom vacuum chamber with ports to facilitate surface chemistry diagnostics. The MAPP’s overall design enables rapid sample turnaround and in vacuo surface characterization. The surface analysis vacuum chamber has ports for x-ray photoelectron spectroscopy, thermal desorption spectroscopy, back-scatter ion scattering spectroscopy, forward-scatter ion scattering spectroscopy, and direct recoil spectroscopy. The sample manipulator and holder is a Lesker/UHV Multi-Centre Analytical Stage, which is used to place the samples in the exposure region of the Proto-MPEX or the analysis position in the MAPP vacuum chamber. The sample holder has a heating capability of up to 1200 °C for heated exposure and for desorption studies. In this work, we present the MAPP’s design and the first tungsten sample exposure with ex situ analysis that shows a surface deposition layer on the exposed target, highlighting the need for additional in situ measurements on the Proto-MPEX.

Beers, C. J. (ORCID:0000000150985459)↗

An extended variational method for the resistive wall mode in toroidal plasma confinement devices

The external-kink stability of a toroidal plasma surrounded by a rigid resistive wall is investigated. The well-known analysis of Haney and Freidberg is rigorously extended to allow for a wall that is sufficiently thick that the thin-shell approximation does not necessarily hold. A generalized Haney–Freidberg formula for the growth-rate of the resistive wall mode is obtained. Thick-wall effects do not change the marginal stability point of the mode but introduce an interesting asymmetry between growing and decaying modes. Growing modes have growth-rates that exceed those predicted by the original Haney–Freidberg formula. On the other hand, decaying modes have decay-rates that are less than those predicted by the original formula. The well-known Hu–Betti formula for the rotational stabilization of the resistive wall mode is also generalized to take thick-wall effects into account. Increasing wall thickness facilitates the rotational stabilization of the mode, because it decreases the critical toroidal electromagnetic torque that the wall must exert on the plasma. On the other hand, the real frequency of the mode at the marginal stability point increases with increasing wall thickness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of tantalum deposition and growth on TiB2 and ZrB2 from PISCES-RF deuterium and helium plasma exposures

Deuterium and helium plasma exposures on bulk TiB2 and ZrB2 samples were performed using the PISCES-RF linear plasma device. 40 and 90 eV deuterium ion plasma exposures were performed at 240 and 800 °C sample temperatures, and 80 eV helium ion plasma exposures were performed at 800 °C sample temperatures. Following plasma exposures, it was discovered that two plasma conditions (90 eV deuterium and 80 eV helium at 800 °C) resulted in thick (>200 nm) tantalum-rich (>10 at%) surface features on the targets, presumably from tantalum sourced from a tantalum adapter mask or cap used as part of the target holder. This work aims to characterize these tantalum-rich features and examine the mechanisms of impurity deposition.Plasma-induced surface morphology of the tantalum-rich surface layers depends on plasma properties and target temperature and chemistry. Greater titanium sputtering compared to zirconium resulted in more distinct surface features in the TiB2 samples compared to the ZrB2 samples via increased, prompt deposition onto tantalum surface impurities. There is still uncertainty as to why thick tantalum deposition only occurred under some plasma exposure conditions but not others; it is likely due to tantalum sputtering by a combination of boron molecules from the targets and carbon-impurities in the tantalum mask or targets. Impurity driven surface features are a well-documented phenomena in samples exposed to plasma from linear plasma device facilities—this work confirms the occurrence of this and emphasizes the need for chemistry characterization of isolated post-mortem surface features in plasma-exposed samples.

Nuckols, Lauren↗

Simulation of plasma and neutral transport in PISCES-RF using SOLPS-ITER

In this research, the fluid plasma transport code SOLPS-ITER is applied and validated against experimental data from the plasma interaction surface component experimental station (PISCES)-RF linear plasma device to establish a physics basis for plasma and neutral transport in its two magnetic field (B-field) geometry setups-(1)the cusp and (2) non-cusp or linear B-field. The main focus of this study is to understand (1) radial plasma transport (2) heat and particle loads on the upstream dump and downstream target plate, and (3) the physics of plasma-neutral interactions in PISCES-RF. The simulation setup adheres to typical PISCES-RF experimental conditions, with a 2D helicon power deposition profile as an input heating source. SOLPS-ITER simulations reproduce experimental conditions with the Bohm diffusion model for both B-field configurations of the PISCES-RF experiment. Major energy loss channels include neutral radiation and power deposited on the wall and dump plate, with only 1% of the input power reaching the target. The ionization front is well confined near the dump plate due to the heating and puffing regions. Additionally, SOLPS-ITER simulation results are also found to be in very good agreement with the particle-in-cell calculations using the code-PICOS++ which supports the validity of SOLPS in low collisionality regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The magnetic gradient scale length explains why certain plasmas require close external magnetic coils

Abstract The separation between the last closed flux surface of a plasma and the external coils that magnetically confine it is a limiting factor in the construction of fusion-capable plasma devices. This plasma-coil separation must be large enough so that components such as a breeding blanket and neutron shielding can fit between the plasma and the coils. Plasma-coil separation affects reactor size, engineering complexity, and particle loss due to field ripple. For some plasmas it can be difficult to produce the desired flux surface shaping with distant coils, and for other plasmas it is infeasible altogether. Here, we seek to understand the underlying physics that limits plasma-coil separation and explain why some configurations require close external coils. In this paper, we explore the hypothesis that the limiting plasma-coil separation is set by the shortest scale length of the magnetic field as expressed by the ∇ B tensor. We tested this hypothesis on a database of > 40 stellarator and tokamak configurations. Within this database, the coil-to-plasma distance compared to the minor radius varies by over an order of magnitude. The magnetic scale length is well correlated to the coil-to-plasma distance of actual coil designs generated using the REGCOIL method (Landreman 2017 Nucl. Fusion 57 046003). Additionally, this correlation reveals a general trend that larger plasma-coil separation is possible with a small number of field periods.

Physics↗

Considerations for in situ, real time measurement of plasma-material interactions using Digital Holographic imaging

Digital Holographic (DH) imaging is a laser-based measurement technique, which can be used to monitor a material surface as it is being exposed to fusion-relevant plasmas. Both single-laser and dual-laser DH measurements have been demonstrated ex situ at Oak Ridge National Laboratory (ORNL). A DH diagnostic system is being assessed for deployment at ORNL to make in situ, real-time measurements of plasma erosion/redeposition in the Prototype Material Plasma Exposure eXperiment (Proto-MPEX). In situ, real time measurements pose unique challenges to diagnostic systems, which are not encountered by ex situ analysis techniques. The absolute surface height (tracked at the nm to μm position) during plasma exposure can be modified by: 1) surface movement due to vibration or thrust exerted by the plasma device, 2) surface growth due to the thermal expansion of the material under steady MW/m2 or transient GW/m2 plasma heat loads, and 3) surface modification due to plasma erosion/redeposition of the material substrate. To assess these effects, 1) the vibration spectrum of the diagnostic and the pulsed plasma device have been measured, 2) the thermal growth of the surface has been measured for an applied heat flux, and 3) the surface modification has been measured ex situ post plasma exposure, and ex situ post laser ablation as a proxy for the plasma. This paper will provide an overview of the results that have been achieved in the development of a DH diagnostic for in situ real-time measurements of plasma exposed surfaces in the Proto-MPEX device.

Biewer, Theodore↗

Deuterium plasma induced preferential erosion in ultra-high temperature ceramics TiB 2 and ZrB 2 *

Abstract Steady-state deuterium plasma exposures were performed on ultra-high temperature ceramics titanium diboride (TiB 2 ) and zirconium diboride (ZrB 2 ) using the PISCES-RF linear plasma device (LPD) as early screening for first wall, plasma-facing applications. Deuterium plasma exposures were performed using 40 eV ion energies at 240, 525, and 800 °C sample temperatures and 90 eV ion energies at 240 °C sample temperatures to analyze TiB 2 and ZrB 2 surface morphology and chemistry evolution behavior. Post-plasma exposure chemistry characterization of the near surface ( < 50 nm) region of the samples all show transition metal enrichment, indicating boron preferential erosion. Transition metal to boron fractions vary with plasma exposure temperature under the 40 eV ion energy; metal enrichment is maximized at 800 °C and then minimized at 525 °C. SEM micrographs of all plasma exposed sample surfaces show no significant or noticeable plasma induced damage from cracking or blistering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven, ion-scale magnetospheres in laboratory plasmas. II. Particle-in-cell simulations

Ion-scale magnetospheres have been observed around comets, weakly magnetized asteroids, and localized regions on the Moon and provide a unique environment to study kinetic-scale plasma physics, in particular in the collision-less regime. In this work, we present the results of particle-in-cell simulations that replicate recent experiments on the large plasma device at the University of California, Los Angeles. Using high-repetition rate lasers, ion-scale magnetospheres were created to drive a plasma flow into a dipolar magnetic field embedded in a uniform background magnetic field. The simulations are employed to evolve idealized 2D configurations of the experiments, study highly resolved, volumetric datasets, and determine the magnetospheric structure, magnetopause location, and kinetic-scale structures of the plasma current distribution. We show the formation of a magnetic cavity and a magnetic compression in the magnetospheric region, and two main current structures in the dayside of the magnetic obstacle: the diamagnetic current, supported by the driver plasma flow, and the current associated with the magnetopause, supported by both the background and driver plasmas with some time-dependence. From multiple parameter scans, we show a reflection of the magnetic compression, bounded by the length of the driver plasma, and a higher separation of the main current structures for lower dipolar magnetic moments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of a portable diagnostic system for Thomson scattering measurements on an electrothermal arc source

To fulfill the increasing needs of diagnostic support for researchers in plasma technology, a portable diagnostic package (PDP) equipped for both laser Thomson scattering (TS) and optical emission spectroscopy has been designed and constructed at Oak Ridge National Laboratory (ORNL), aiming to measure the temperature and number density of electrons and temperatures of ions in plasma devices. The PDP has been initially implemented on a high density and low temperature electrothermal arc source (ET-arc) at ORNL to test its TS capability. TS from the plasmas in the ET-arc has been obtained using the PDP. The electron temperature and number density were determined from TS spectra. These results were then compared to measurements from previous studies on the ET-arc. The TS diagnostic measured 0.8 ± 0.1, 1.3 ± 0.2, and 0.7 ± 0.1 eV and (4.4 ± 0.5) × 1021, (5.9 ± 0.7) × 1021, and (4.3 ± 0.5) x 1021 m-3, respectively, from three lines of sight that transect the plasma column.

He, Z. (ORCID:0000000183159882)↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of machine learning for a helium line intensity ratio method in Magnum-PSI

Optical emission spectroscopy (OES) of helium (He) line intensities has been used to measure the electron density, ne, and temperature, Te, in various plasma devices. In this study, a neural network with five hidden layers is introduced to model the relation between the OES data and ne/Te from laser Thomson scattering in the linear plasma device Magnum-PSI and compared to multiple regression analysis. It is shown that the neural network reduces the residual errors of prediction values (ne and Te) less than half those of the multiple regression analysis. We checked two different data splitting methods for training and validation data, i.e., with and without considering the unit of discharge. A comparison of the splitting methods suggests that the residual error will decrease to ~10% even for a new discharge data when accumulating a sufficient data set.

Kajita, Shin↗

Multi-electrode/multi-modal atmospheric pressure glow discharge plasma ionization device

Apparatus include an atmospheric pressure glow discharge (APGD) analyte electrode defining an analyte discharge axis into an APGD volume, and a plurality of APGD counter electrodes having respective electrical discharge ends directed to the APGD volume, wherein the APGD analyte electrode and the APGD counter electrodes are configured to produce an APGD plasma in the APGD volume with a voltage difference between the APGD analyte electrode and one or more of the AGPD counter electrodes. An electrode can be integrated into an ion inlet. Apparatus can be configured to perform auto-ignition and/or provide multi-modal operation through selectively powering electrodes. Electrode holder devices are disclosed. Related methods are disclosed.

Koppenaal, David W.↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New application of hyperspectral imaging to steady-state plasma observations

A new application of hyperspectral imaging (HSI) to steady-state plasma emission observations is proposed because of its prominent feature: an HSI camera records a two-dimensional image, and each spatial pixel contains spectral data typically with more than a hundred bands, while conventional digital cameras have only three bands. The characterization of an HSI camera (Specim IQ) has been performed during steady-state plasma–material interaction experiments using the linear plasma device PISCES-A. By easily subtracting the background/continuum emission in contrast to conventional filter cameras, two-dimensional images of multiple emission lines at different wavelengths are simultaneously obtained during a single measurement, demonstrating the advantage in plasma emission observations.

47 OTHER INSTRUMENTATION↗