Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Microscopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A large granite stage and measuring microscope.

A stage and measuring microscope servocontrolled by a computer have been constructed. The travel of the stage is 0.5 x 0.5 m and the travel of the microscope objective is 7.5 cm. The measuring accuracy is 1 micron in the x-y plane and 5 microns along the z axis. The mechanical and optical construction of the stage and microscope, as well as the way in which the control electronics are organized, permit great flexibility of operation. Possible applications include the scanning and measuring of astronomical plates, the laying out of patterns of semiconductor devices of very large sizes, and the measurement of precision grids.

Alston-Garnjost, M.

Study of a quasi-microscope design for planetary landers

The Viking Lander fascimile camera, in its present form, provides for a minimum object distance of 1.9 meters, at which distance its resolution of 0.0007 radian provides an object resolution of 1.33 millimeters. It was deemed desirable, especially for follow-on Viking missions, to provide means for examing Martian terrain at resolutions considerably higher than that now provided. This led to the concept of quasi-microscope, an attachment to be used in conjunction with the fascimile camera to convert it to a low power microscope. The results are reported of an investigation to consider alternate optical configurations for the quasi-microscope and to develop optical designs for the selected system or systems. Initial requirements included consideration of object resolutions in the range of 2 to 50 micrometers, an available field of view of the order of 500 pixels, and no significant modifications to the fascimile camera.

Giat, O.

Microscopic investigation of cavitation erosion damage in metals

The results of research to identify the cavitation erosion damage mechanisms at the microscopic level for three metals (aluminum, stainless steel, and titanium) representing a range of properties and microstructure are presented. The metals were exposed to cavitation generated in distilled water by a 20-kHz ultrasonic facility operating at a vibration amplitude of 2 mils. Representative properties of the metals and experimental details are summarized. Replicas of the eroded surfaces of the specimens obtained periodically during exposure were examined with a transmission electron microscope to follow progression of the erosion damage and identify dominant erosion mechanisms as a function of exposure time. Eroded surfaces of selected specimens were also examined with a scanning electron microscope to assist in the interpretation.

Hackworh, J. V.

Molecular rotation and reorientation - Microscopic and hydrodynamic contributions

The relative roles of microscopic and hydrodynamic contributions to molecular rotation and reorientation are examined within the framework of the microscopic boundary layer theory recently proposed by the authors. The theory is applied to rough spheres, for which computer simulation data are available and to experimental results on spherical top molecules. Attention is focused on rotational diffusion constants, the kappa parameter introduced by Kivelson et al., and orientational relaxation times. It is shown that, while collective effects are present and often nonnegligible, the motion of small molecules is dominated by its microscopic aspects. Experimental trends which can incorrectly suggest dominance by hydrodynamic contributions are discussed in some detail. Finally, the transition to the regime where collective effects are dominant is considered.

Hynes, J. T.

Design of an imaging microscope for soft X-ray applications

An imaging soft X-ray microscope with a spatial resolution of 0.1 micron and normal incidence multilayer optics is discussed. The microscope has a Schwarzschild configuration, which consists of two concentric spherical mirrors with radii of curvature which minimize third-order spherical aberration, coma, and astigmatism. The performance of the Stanford/MSFC Cassegrain X-ray telescope and its relevance to the present microscope are addressed. A ray tracing analysis of the optical system indicates that diffraction-limited performance can be expected for an object height of 0.2 mm.

Hoover, Richard B.

Development of a normal incidence multilayer, imaging X-ray microscope

This paper describes the design, analysis, and fabrication of a normal-incidence multilayer 20x Schwarzschild imaging X-ray microscope. The microscope is being fabricated using much of the technology implemented in the Multispectral Solar Telescope Array. Results of diffraction analysis show that better than 400 A spatial resolution in the object plane up to a 1-mm field of view can be achieved with 125 A radiation. Other microscope systems for use in conjunction with X-ray telescopes are analyzed and designed.

Shealy, David L.

Sample holder support for microscopes

A sample filter holder is disclosed for use with a microscope for holding the filter in a planar condition on the stage of the microscope so that automatic focusing of the microscope can be performed on particle samples dispersed on the filter. The holder includes a base having a well that communicates with an inlet port which is connected to a suction pump. A screen assembly is positioned within the well. The screen assembly includes a disk having a screen positioned on its top surface and secured to the disk at the peripheral edge of the screen. Small bores allow the outer surface of the screen to communicate with the well. The filter is placed on the screen and is held in a flat disposition by the suction forces.

Berry, Anthony

Design and analysis of aspherical multilayer imaging X-ray microscope

Spherical Schwarzschild microscopes for soft X-ray applications in microscopy and projection lithography employ two concentric spherical mirrors that are configured such that the third-order spherical aberration and coma are zero. Based on incoherent, sine-wave MTF calculations, the object-plane resolution of a magnification-factor-20 microscope is presently analyzed as a function of object height and numerical aperture of the primary for several spherical Schwarzschild, conic, and aspherical two-mirror microscope configurations.

Shealy, David L.

Determination of the Critical Parameters for Remote Microscope Control

As part of a program to determine the capabilities of Telescience as applied to Microgravity Materials Science the need for a remotely controlled microscope was recognized. For this purpose we equipped a microscope with an X-Y-Z positioning device and motors on the zoom and focus controls. Computer control of these devices allowed remote operation. A standard TV camera was mounted to the computer controlled video board which could compress the image in resolution and grey scale. The operator control console was programmed to display three still video pictures as well as provide command access. A standard data transfer network was used to transmit the video data files and the command interaction was via a high speed phone modem. This system, with the microscope in the Microgravity Materials Science Laboratory (MMSL) at LeRC and the control at RPI, was used to determine the accuracy of setting, time required to achieve setting and the operator ease factor. It was found that the focus setting could be established well within the resolution limit of the TV system and that each motion took about 50 seconds and approximately 12 minutes was required to reach ?best? focus. These times could be reduced significantly with operator experience. The operators were provided with ancillary equipment which provided assistance in making the necessary decisions and they reported satisfaction with the control.

Hahn, R. C.

Fuzzy control system for a remote focusing microscope

Space Station Crew Health Care System procedures require the use of an on-board microscope whose slide images will be transmitted for analysis by ground-based microbiologists. Focusing of microscope slides is low on the list of crew priorities, so NASA is investigating the option of telerobotic focusing controlled by the microbiologist on the ground, using continuous video feedback. However, even at Space Station distances, the transmission time lag may disrupt the focusing process, severely limiting the number of slides that can be analyzed within a given bandwidth allocation. Substantial time could be saved if on-board automation could pre-focus each slide before transmission. The authors demonstrate the feasibility of on-board automatic focusing using a fuzzy logic ruled-based system to bring the slide image into focus. The original prototype system was produced in under two months and at low cost. Slide images are captured by a video camera, then digitized by gray-scale value. A software function calculates an index of 'sharpness' based on gray-scale contrasts. The fuzzy logic rule-based system uses feedback to set the microscope's focusing control in an attempt to maximize sharpness. The systems as currently implemented performs satisfactorily in focusing a variety of slide types at magnification levels ranging from 10 to 1000x. Although feasibility has been demonstrated, the system's performance and usability could be improved substantially in four ways: by upgrading the quality and resolution of the video imaging system (including the use of full color); by empirically defining and calibrating the index of image sharpness; by letting the overall focusing strategy vary depending on user-specified parameters; and by fine-tuning the fuzzy rules, set definitions, and procedures used.

Weiss, Jonathan J.

The microscopic state of the solar wind: Links between composition, velocity distributions, waves and turbulence

An overview is given of the microscopic state of the solar wind with emphasis on recent Ulysses high-latitude observations and previous Helios in-ecliptic observations. The possible links between composition, ionization state. velocity distribution functions of electrons, protons and heavy ions. kinetic plasma waves and MHD-scale turbulence are elaborated. Emphasis is placed on a connection of interplanetary kinetic-scale phenomena with their generating microscopic processes in the corona. The fast streams seem to consist of mesoscale pressure-balanced plasma filaments and magnetic flux tubes, reminiscent of the supergranular-size structures building the open corona, from which copious Alfven waves emanate. The wind from the magnetically structured and active corona shows developed compressive turbulence and considerable abundance and ionization state variations. Some modelling attempts to explain the observed element fractionation are briefly reviewed. The causes of the nonthermal particle features. such as proton-ion differential streaming, ion beams. temperature anisotropies, and skewed distributions associated with collisionless heat conduction, are ultimately to be searched in the fact, that the corona is never quiescent but fundamentally variable in space and time. Consequently, the radial evolution of the internal state of the wind resembles at all latitudes a complicated relaxation process, in the course of which the free (in comparison with LTE conditions) particle kinetic energy is converted into plasma waves and MHD turbulence on a wide range of scales. This leads to intermittent wave-particle interactions and unsteady anomalous transport, mixed with the weak effects of the rare Coulomb collisions. Spherical expansion and large-scale inhomogeneity forces the wind to attain microscopically a complex internal state of dynamic statistical equilibrium.

Marsch, E.

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone Under Microgravity

USA Several microgravity experiments on sounding rockets and the Space Shuttle have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed during the TEXUS36 flight (February 7, 1998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3 Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4 mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Marangoni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies ? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone and Microgravity

A silicon crystal growth experiment has been accomplished using the floating-zone technique under microgravity on a sounding rocket (TEXUS 36). Measurements of temperature fluctuations in the silicon melt zone due to time dependent thermocapillary convection (Marangoni convection) and an observation of the microscopic growth rate were simultaneously performed during the experiment. Temperature fluctuations of about 0.5 - 0.7 C with a frequency range < 0.5Hz were detectable. The microscopic growth rate fluctuates considerably around the average growth rate of 1 mm/min: Growth rates up to 3 to 4mm/min, close to zero mm/min, as well as negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies of temperature fluctuations, microscopic growth rates, and the dopant inhomogeneities correspond quite well, with main frequencies between 0.1 and 0.3 Hz. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, and the characteristic temperature amplitudes and frequencies. At a position 3.4mm above the interface and 1.4mm inside the melt, equivalent to the sensor tip position in the experiment, temperature fluctuations up to 1.8 C and frequencies ? 0.25Hz were found in the simulations.

Schweizer, Markus

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone on TEXUS36

Several pg experiments on sounding rockets and the Space Shuttle have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed during the TEXUS36 flight (February 7, 1 998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Marangoni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone on TEXUS36

Several earlier (micro)g experiments have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed on the TEXUS36 flight (February 7, 1 998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3 Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Maran-goni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies f? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne

Microscope-Based Fluid Physics Experiments in the Fluids and Combustion Facility on ISS

At the NASA Glenn Research Center, the Microgravity Science Program is planning to conduct a large number of experiments on the International Space Station in both the Fluid Physics and Combustion Science disciplines, and is developing flight experiment hardware for use within the International Space Station's Fluids and Combustion Facility. Four fluids physics experiments that require an optical microscope will be sequentially conducted within a subrack payload to the Fluids Integrated Rack of the Fluids and Combustion Facility called the Light Microscopy Module, which will provide the containment, changeout, and diagnostic capabilities to perform the experiments. The Light Microscopy Module is planned as a fully remotely controllable on-orbit microscope facility, allowing flexible scheduling and control of experiments within International Space Station resources. This paper will focus on the four microscope-based experiments, specifically, their objectives and the sample cell and instrument hardware to accommodate their requirements.

Doherty, Michael P.

A Hydrodynamic Theory for Spatially Inhomogeneous Semiconductor Lasers: Microscopic Approach

Starting from the microscopic semiconductor Bloch equations (SBEs) including the Boltzmann transport terms in the distribution function equations for electrons and holes, we derived a closed set of diffusion equations for carrier densities and temperatures with self-consistent coupling to Maxwell's equation and to an effective optical polarization equation. The coherent many-body effects are included within the screened Hartree-Fock approximation, while scatterings are treated within the second Born approximation including both the in- and out-scatterings. Microscopic expressions for electron-hole (e-h) and carrier-LO (c-LO) phonon scatterings are directly used to derive the momentum and energy relaxation rates. These rates expressed as functions of temperatures and densities lead to microscopic expressions for self- and mutual-diffusion coefficients in the coupled density-temperature diffusion equations. Approximations for reducing the general two-component description of the electron-hole plasma (EHP) to a single-component one are discussed. In particular, we show that a special single-component reduction is possible when e-h scattering dominates over c-LO phonon scattering. The ambipolar diffusion approximation is also discussed and we show that the ambipolar diffusion coefficients are independent of e-h scattering, even though the diffusion coefficients of individual components depend sensitively on the e-h scattering rates. Our discussions lead to new perspectives into the roles played in the single-component reduction by the electron-hole correlation in momentum space induced by scatterings and the electron-hole correlation in real space via internal static electrical field. Finally, the theory is completed by coupling the diffusion equations to the lattice temperature equation and to the effective optical polarization which in turn couples to the laser field.

Li, Jianzhong

Microscopic Foundation and Simulation of Coupled Carrier-Temperature Diffusions in Semiconductor Lasers

A typical semiconductor-based optoelectronic device, such as a diode laser, consists of three subsystems: an optical field, an electron-hole plasma (EHP), and a host crystal lattice. The physics of such a device involves the interplay of optical, electrical and thermal processes. A proper description of such a device requires that all three processes are treated on equal footing and in a self-consistent fashion. Furthermore, since a semiconductor laser has intrinsic spatial inhomogeneity, such a self-consistency naturally leads to a set of partial differential equations in space and time. There is a significant lacking of research interest and results on the transport aspects of optical devices in the literature with only a few exceptions. Even the most important carrier diffusion coefficient has not been properly derived and studied so far for optically excited plasma, while most of the work adopted results from electronics community where heavily doped semiconductors with mainly one type of carriers are dealt with. The corresponding transport equation for plasma energy or temperature has received even less attention. In this talk we describe our recent results on such a self-consistent derivation of temperature and carrier-density diffusion equations coupled with the lasing process. Starting from the microscopic semiconductor Bloch equations (SBEs) including the Boltzmann transport terms in the distribution function equations for electrons and holes, we derived a closed set of diffusion equations for carrier densities and temperatures with self-consistent coupling to Maxwell's equation and to an effective optical polarization equation. The coherent many-body effects are included within the screened Hartree-Fock approximation, while scatterings are treated within the second Born approximation including both the in- and out-scatterings. Microscopic expressions for electron-hole (e-h) and carrier-LO (c-LO) phonon scatterings are directly used to derive the momentum and energy relaxation rates. These rates expressed as functions of temperatures and densities lead to microscopic expressions for self- and mutual-diffusion coefficients in the coupled density-temperature diffusion equations. Approximations for reducing the general two-component description of the electron-hole plasma (EHP) to a single-component one are discussed. In particular, we show that a special single-component reduction is possible when e-h scattering dominates over c-LO phonon scattering. The ambipolar diffusion approximation is also discussed and we show that the ambipolar diffusion coefficients are independent of e-h scattering, even though the diffusion coefficients of individual components depend sensitively on the e-h scattering rates. Our discussions lead to new perspectives into the roles played in the single-component reduction by the electron-hole correlation in momentum space induced by scatterings and the electron-hole correlation in real space via internal static electrical field. Finally, the theory is completed by coupling the diffusion equations to the lattice temperature equation and to the effective optical polarization which in turn couples to the laser field. The equations derived above are implemented in various limiting cases to a typical diode laser to study the consequences of nonlinear diffusion and the cross diffusion terms on laser behavior, especially the dynamic behavior of a diode laser under modulation. Detailed results will be presented by comparing with the standard rate equation results.

Li, J.