Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

Two-dimensional photon-counting detector arrays based on microchannel array plates

The production of simple and rugged photon-counting detector arrays has been made possible by recent improvements in the performance of the microchannel array plate (MCP) and by the parallel development of compatible electronic readout systems. The construction of proximity-focused MCP arrays of novel design in which photometric information from (n x m) picture elements is read out with a total of (n + m) amplifier and discriminator circuits is described. Results obtained with a breadboard (32 x 32)-element array employing 64 charge-sensitive amplifiers are presented, and the application of systems of this type in spectrometers and cameras for use with ground-based telescopes and on orbiting spacecraft discussed.

Timothy, J. G.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Development and test of photon-counting microchannel plate detector arrays for use on space telescopes

The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.

Timothy, J. G.↗

Microchannel plate life tests

The behavior of the gain of a microchannel plate (MCP) during operation of the latter at moderate output currents was investigated. The total charge per unit area, Q, extracted from the MCP is shown to be the relevant quantity for evaluating MCP performance. The shape of the gain versus Q curve provides information on the gain decay process. Long periods of stable gain, frequently exhibited by channeltrons, were not observed in the present experiment.

Sandel, B. R.↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

Multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are described.

Timothy, J. G.↗

A progress report on multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are briefly described.

Timothy, J. G.↗

Two-dimensional ultraviolet imagery with a microchannel-plate/resistive-anode detector

An imaging ultraviolet detector has been designed for use with a precision pointed telescope flown on a sounding rocket. Resolution of better than 80 microns over a field of 5 mm has been achieved. The ultraviolet image is converted to electrons at the front surface of a CsI coated chevron microchannel-plate electron multiplier. For each photoelectron, the multiplier produces a burst of about 3,000,000 electrons, which impinges on a tellurium-coated resistive anode with four evaporated hyperbolic readout electrodes. The sizes of the four resulting output pulses are digitized to 10 bit accuracy and telemetered to the ground, where they are divided in pairs to give the x and y coordinates of the photoelectron event. The coordinates are used to generate a picture in real time, and are recorded for computer processing later. The detector was successfully flown in December 1978. Good images of Jupiter and Capella in hydrogen Lyman alpha emission were obtained.

Opal, C. B.↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗

Multianode microchannel array detectors for Space Shuttle imaging applications

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric, photoncounting array detectors that have been developed and qualified specifically for use in space. MAMA detectors with formats as large as 256 x 1024 pixels are now in use or under construction for a variety of imaging and tracking applications. These photo-emissive detectors can be operated in a windowless configuration at extreme ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. The construction and modes-of-operation of the MAMA detectors are briefly described and the scientific objectives of a number of sounding rocket and Space Shuttle instruments utilizing these detectors are outlined. Performance characteristics of the MAMA detectors that are of fundamental importance for operation in the Space Shuttle environment are described and compared with those of the photo-conductive array detectors such as the CCDs and CIDs.

Timothy, J. G.↗

Curved-channel microchannel array plates

The microchannel array plate (MCP) is a photoelectric detector with an imaging capability comparable to that of a photographic plate. Recently MCPs in which the channels are curved to inhibit ion feedback have become available. These devices represent a major advance in MCP technology, since a single curved-channel MCP can be operated stably at high gain in the pulse-counting mode without any of the problems of stability of response or short lifetime reported for 'chevron' MCP detectors. Attention is given to the mode of operation of channel electron multipliers (CEM) and MCP, curved-channel MCP, test procedures, and performance characteristics. The accumulated test data show that the fundamental operating characteristics of the curved-channel MCP are directly related to those for the CEM.

Timothy, J. G.↗

Microchannel spatial light modulator

The Microchannel Spatial Light Modulator (MSLM), a versatile, highly sensitive, and optically addressed device being developed for real time optical information processing is discussed. The MSLM operates by converting an input optical image into a charge distribution at the surface of an electro-optic crystal. The charge distribution generates an electric field which modulates the refractive index of the crystal and thereby the phase or intensity of an image readout beam. Prototype devices employing 250 micron thick crystals exhibited a spatial resolution of 5 cycles/mm at 50% contrast, an exposure sensitivity of 2.2 nJ/cu cm and framing rates of 40 Hz with full modulation depth. The image processing operations that have been achieved using the internal processing mode of the MSLM include contrast reversal, contrast enhancement, edge enhancement, image addition and subtraction, analog and digital intensity thresholding, and binary level logic operations such as AND, OR, EXCLUSIVE OR, and NOR.

Warde, C.↗

Characteristics of a microchannel plate intensifier

A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

Sandie, W. G.↗

Rocket-borne instrument with a high-resolution microchannel plate detector for planetary UV spectroscopy

A telescope-spectrograph employing a photon-counting microchannel plate (MCP)-CODACON detector has been built, tested, and flown on a sounding rocket. The detector uses a curved-channel MCP proximity focused onto a coded anode array of 1024 channels spaced 25.4-mm center to center. High quantum efficiency is obtained by depositing a cesium iodide photocathode on the front surface of the MCP. The instrument has obtained an ultraviolet spectrum of Jupiter with a spectral resolution of 8 A, which is higher than that of any previously reported observation in this wavelength range.

Mcclintock, W. E.↗

Recent progress with multi-anode microchannel array detector systems

The construction and modes of operation of Multi-Anode Microchannel Arrays (MAMA's) are briefly reviewed. The MAMA detectors, which are a family of photoelectric, photon-counting array detectors being developed specifically for use in instruments on ground-based and space-borne telescopes, combine the high sensitivity and photometric stability of a conventional channel electron multiplier with a high-resolution imaging capability. The MAMA detectors feature low applied potential (less than 3 kV), high gain (greater than 10 to the 6th electrons/pulse), an absolute event timing accuracy of 100 ns or better, a very long count lifetime (greater than 2.5 x 10 to the 11th counts/sq mm), and a power consumption of less than 30 W for a complete system

Timothy, J. G.↗

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.↗

Maximizing the quantum efficiency of microchannel plate detectors - The collection of photoelectrons from the interchannel web using an electric field

High quantum efficiency and two-dimensional imaging capabilities make the microchannel plate (MCP) a suitable detector for a sky survey instrument. The Extreme Ultraviolet Explorer satellite, to be launched in 1987, will use MCP detectors. A feature which limits MCP efficiency is related to the walls of individual channels. The walls are of finite thickness and thus form an interchannel web. Under normal circumstances, this web does not contribute to the detector's quantum efficiency. Panitz and Foesch (1976) have found that in the case of a bombardment with ions, electrons were ejected from the electrode material coating the web. By applying a small electric field, the electrons were returned to the MCP surface where they were detected. The present investigation is concerned with the enhancement of quantum efficiencies in the case of extreme UV wavelengths. Attention is given to a model and a computer simulation which quantitatively reproduce the experimental results.

Taylor, R. C.↗