Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MS software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

PSpecteR: A User-Friendly and Interactive Application for Visualizing Top-Down and Bottom-Up Proteomics Data in R

Visual examination of mass spectrometry data is necessary to assess data quality and to facilitate data exploration. Graphics provide the means to evaluate spectral properties, test alternative peptide/protein sequence matches, prepare annotated spectra for publication, and fine-tune parameters during wet lab procedures. Visual inspection of MS data is hindered by proprietary proteomics visualization software designed for particular workflows and academic software that lack visualization tools. We built PSpecteR, an open-source and interactive R Shiny web application to address these issues, with support for several steps of proteomics data processing, including: reading various mass spectrometry files, running open-source database search tools, labelling spectra with fragmentation patterns, testing post-translational modifications, plotting where identified fragments map to reference sequences, and visualizing algorithmic output and metadata. All figures, tables, and spectra are exportable within one easy-to-use graphical user interface. Our current software provides a flexible and modern R framework to support fast implementation of additional features. The open source code is readily available (https://github.com/EMSL-Computing/PSpecteR), and a PSpecteR Docker container (https://hub.docker.com/r/emslcomputing) is available for easy local installation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Digitizing Curves from LA-10860 to be Used in CritView

This report documents the digitization of figures from LA-10860-MS in order to import the data into the CritView software application. The original figures were created by Los Alamos National Laboratory and the latest revision was released in 1986. All figures were digitized using Engauge Digitizer (ver. 12.1) .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Applied Meteorology Unit (AMU) Quarterly Report Fourth Quarter FY-13

Ms. Shafer completed the task to determine relationships between pressure gradients and peak winds at Vandenberg Air Force Base (VAFB), and began developing a climatology for the VAFB wind towers; Dr. Huddleston completed the task to develop a tool to help forecast the time of the first lightning strike of the day in the Kennedy Space Center (KSC)/Cape Canaveral Air Force Station (CCAFS) area; Dr. Bauman completed work on a severe weather forecast tool focused on the Eastern Range (ER), and also developed upper-winds analysis tools for VAFB and Wallops Fl ight Facility (WFF); Ms. Crawford processed and displayed radar data in the software she will use to create a dual-Doppler analysis over the east-central Florida and KSC/CCAFS areas; Mr. Decker completed developing a wind pairs database for the Launch Services Program to use when evaluating upper-level winds for launch vehicles; Dr. Watson continued work to assimilate observational data into the high-resolution model configurations she created for WFF and the ER.

Bauman, William↗

Evaluating Software Tools for Lipid Identification from Ion Mobility Spectrometry–Mass Spectrometry Lipidomics Data

The unambiguous identification of lipids is a critical component of lipidomics studies and greatly impacts the interpretation and significance of analyses as well as the ultimate biological understandings derived from measurements. The level of structural detail that is available for lipid identifications is largely determined by the analytical platform being used. Mass spectrometry (MS) coupled with liquid chromatography (LC) is the predominant combination of analytical techniques used for lipidomics studies, and these methods can provide fairly detailed lipid identification. More recently, ion mobility spectrometry (IMS) has begun to see greater adoption in lipidomics studies thanks to the additional dimension of separation that it provides and the added structural information that can support lipid identification. At present, relatively few software tools are available for IMS-MS lipidomics data analysis, which reflects the still limited adoption of IMS as well as the limited software support. This fact is even more pronounced for isomer identifications, such as the determination of double bond positions or integration with MS-based imaging. In this review, we survey the landscape of software tools that are available for the analysis of IMS-MS-based lipidomics data and we evaluate lipid identifications produced by these tools using open-access data sourced from the peer-reviewed lipidomics literature.

59 BASIC BIOLOGICAL SCIENCES↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Software for a Lidar-Altimeter Processor

A report describes the development of software for a digital processor that operates in conjunction with a finite-impulse-response (FIR) chip in a spaceborne lidar altimeter. Processing is started by a laser-fire interrupt signal that is repeated at intervals of 25 ms. For the purpose of discriminating between returns from the ground and returns from such things as trees, buildings, and clouds, the software is required to scan digitized lidar-return data in reverse of the acquisition sequence in order to distinguish the last return pulse from within a commanded ground-return range window. The digitized waveform information within this range window is filtered through 6 matched filters, in the hardware electronics, in order to maximize the probability of finding echoes from sloped or rough terrain and minimize the probability of selecting cloud returns. From the data falling past the end of the range window, there is obtained a noise baseline that is used to calculate a threshold value for each filter. The data from each filter is analyzed by a complex weighting scheme and the filter with the greatest weight is selected. A region around the peak of the ground return pulse associated with the selected filter is placed in telemetry, as well as information on its location, height, and other characteristics. The software requires many uplinked parameters as input. Included in the report is a discussion of major software-development problems posed by the design of the FIR chip and the need for the software to complete its process within 20 ms to fit within the overall 25-ms cycle.

Rosenberg, Jacob S.↗

EI_MS_ML

The unambiguous identification of compounds from their electron ionization mass (EI-MS) spectra remains a significant unsolved problem in the field of metabolomics and analytical chemistry as a whole. Typically EI-MS spectra are compared using various mathematical operations that convert the spectral similarity or differences into a distance-like metric that roughly approximates the similarity of any two spectra. A commonly used metric for this is the cosine similarity metric which has values close to one for very similar spectra and a value of zero for very dissimilar spectra; however, no metric is perfect. Due to the prevalence of structurally-similar compounds such as isomers and the prevalence of certain fragmentation patterns across structurally-dissimilar compounds, the unambiguous assignment of EI-MS spectra compounds remains difficult. Frequently, querying an observed EI-MS spectrum against a large database such as the NIST17 library yields multiple possible assignments requiring the end user to distinguish between multiple high scoring hits, or multiple low scoring hits while keeping in mind that the correct hit may not be in the database at all. Although techniques such as orthogonal information from techniques such as chromatography can greatly aid in unambiguous assignment, this also requires more complicated experimental designs and access to more complicated analytical instrumentation. Substructures can be trivially detected and represented as strings using a previously published technique called node coloring from a known chemical structure. However, for experimentally-derived EI-MS spectra this information must be derived from the spectra itself (i.e., because we do not know what compound it represents). To achieve this, the software uses techniques from the field of machine learning and a large training dataset of EI-MS spectra corresponding to known structures annotated with substructure strings, to build models that can predict the presence of a given chemical substructure from an EI-MS spectrum directly.If these predictions are of high-quality (i.e., are unlikely to be false positives), the presence of one or more predicted substructures can be used to constrain the number of possible hits for a query spectrum. Mathematically, this restriction could be expressed in many forms, but the most straight-forward implementation is to weight the cosine similarity of a query spectrum and a plausible database match with a Tanimoto-like coefficient based on the ratio of the number of substructures predicted to the number of substructures present in the potential database hit. Determining which combination of models best reduces assignment ambiguity will be achieved using a combination of manual curation and optimization techniques such as genetic algorithms. This software will perform all the steps necessary to construct said models from a training dataset and evaluate them using a holdout dataset. Various statistical analyses can be performed to determine if this approach does decrease assignment ambiguity. For example, if this approach works, on average, the rank-order of the correct assignment for the holdout set of EI-MS spectra should decrease and the weighted cosine similarities for most of the possible matches in the database should be better than the unweighted cosine similarities. Furthermore, this same pipeline can be used on real experimental data to generate less ambiguous assignments.

Mitchell, Joshua↗

A Software Package for Neural Network Applications Development

Original Backprop (Version 1.2) is an MS-DOS package of four stand-alone C-language programs that enable users to develop neural network solutions to a variety of practical problems. Original Backprop generates three-layer, feed-forward (series-coupled) networks which map fixed-length input vectors into fixed length output vectors through an intermediate (hidden) layer of binary threshold units. Version 1.2 can handle up to 200 input vectors at a time, each having up to 128 real-valued components. The first subprogram, TSET, appends a number (up to 16) of classification bits to each input, thus creating a training set of input output pairs. The second subprogram, BACKPROP, creates a trilayer network to do the prescribed mapping and modifies the weights of its connections incrementally until the training set is leaned. The learning algorithm is the 'back-propagating error correction procedures first described by F. Rosenblatt in 1961. The third subprogram, VIEWNET, lets the trained network be examined, tested, and 'pruned' (by the deletion of unnecessary hidden units). The fourth subprogram, DONET, makes a TSR routine by which the finished product of the neural net design-and-training exercise can be consulted under other MS-DOS applications.

Baran, Robert H.↗

Thermomechanical Multiaxial Fatigue Testing Capability Developed

Structural components in aeronautical gas turbine engines typically experience multiaxial states of stress under nonisothermal conditions. To estimate the durability of the various components in the engine, one must characterize the cyclic deformation and fatigue behavior of the materials used under thermal and complex mechanical loading conditions. To this end, a testing protocol and associated test control software were developed at the NASA Lewis Research Center for thermomechanical axial-torsional fatigue tests. These tests are to be performed on thin-walled, tubular specimens fabricated from the cobalt-based superalloy Haynes 188. The software is written in C and runs on an MS-DOS based microcomputer.

Source record↗

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Here, an automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO 2 F 2 ), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO 3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235 U/ 238 U and 234 U/ 238 U isotope ratios for the UO 2 F 2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of –0.041% and –1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235 U/ 238 U isotope ratio of 0.00206(7), a –0.96% relative difference from the reference value of 0.00208(1). The 234 U/ 238 U and 236 U/ 238 U isotope ratios were 0.000008(1) and 0.000031(4), –5.1% RD and –4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface – including blanks, mass bias, and triplicate extractions – was completed in less than an hour without any sample preparation necessary.

47 OTHER INSTRUMENTATION↗

Prototype high speed optical delay line for stellar interferometry

The long baselines of the next-generation ground-based optical stellar interferometers require optical delay lines which can maintain nm-level path-length accuracy while moving at high speeds. NASA-JPL is currently designing delay lines to meet these requirements. The design is an enhanced version of the Mark III delay line, with the following key features: hardened, large diameter wheels, rather than recirculating ball bearings, to reduce mechanical noise; a friction-drive cart which bears the cable-dragging forces, and drives the optics cart through a force connection only; a balanced PZT assembly to enable high-bandwidth path-length control; and a precision aligned flexural suspension for the optics assembly to minimize bearing noise feedthrough. The delay line is fully programmable in position and velocity, and the system is controlled with four cascaded software feedback loops. Preliminary performance is a jitter in any 5 ms window of less than 10 nm rms for delay rates of up to 28 mm/s; total jitter is less than 10 nm rms for delay rates up to 20 mm/s.

Colavita, M. M.↗

Yeast Transformation on Hamilton Vantage (YT Vantage) v1

Our software program is designed for the Hamilton Vantage liquid handling robot, automating the Build step in the Design-Build-Test-Learn (DBTL) cycle for Saccharomyces cerevisiae. This program minimizes human intervention, enabling rapid identification of pathway bottlenecks and genes that enhance verazine production. The program takes competent yeast and plasmid DNA as input and generates an output library of engineered strains compatible with automated colony picking, high-throughput culturing, and chemical extraction for downstream LC-MS analysis. A user-friendly interface, developed using the Hamilton Method Editor software, allows for on-demand parameter customization. By automating this process, our program streamlines the construction of Saccharomyces cerevisiae, reducing manual labor and increasing efficiency. While the manual process is well-documented, integration with robotic automation is less common, making our program a valuable tool for researchers. With this software, we achieved 2-5 fold increases in verazine production, demonstrating its potential to accelerate research in this field.

Louie, Randy [Lawrence Berkeley National Laborator↗