Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Indirect Calibration In Electron-Probe Microanalysis

Technique for indirect calibration in electron-probe microanalysis reduces number of measurements needed without significantly degrading precision of measurement data. Advantageous when many analyses must be performed; for example, determining varying chemical composition at many positions across specimen of multicomponent alloy. Time spent acquiring data reduced considerably.

Terepka, F. M.↗

Definition of the Spatial Resolution of X-Ray Microanalysis in Thin Foils

The spatial resolution of X-ray microanalysis in thin foils is defined in terms of the incident electron beam diameter and the average beam broadening. The beam diameter is defined as the full width tenth maximum of a Gaussian intensity distribution. The spatial resolution is calculated by a convolution of the beam diameter and the average beam broadening. This definition of the spatial resolution can be related simply to experimental measurements of composition profiles across interphase interfaces. Monte Carlo calculations using a high-speed parallel supercomputer show good agreement with this definition of the spatial resolution and calculations based on this definition. The agreement is good over a range of specimen thicknesses and atomic number, but is poor when excessive beam tailing distorts the assumed Gaussian electron intensity distributions. Beam tailing occurs in low-Z materials because of fast secondary electrons and in high-Z materials because of plural scattering.

Williams, D. B.↗

Laboratory Astrophysics and Microanalysis with NTD-Germanium-Based X-Ray Microcalorimeter

With the ability to create cosmic plasma conditions in the laboratory it is possible to investigate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources with X-ray optics and a high resolution x-ray microcalorimeter. The same instrumentation can be coupled to scanning electron microscopes or x-ray fluorescence probes to analyze the elemental and chemical composition of electronic, biological, geological and particulate materials. We describe how our microcalorimeter and x-ray optics provide significantly improved capabilities for laboratory astrophysics and microanalysis.

Silver, E.↗

Improvements in Electron-Probe Microanalysis: Applications to Terrestrial, Extraterrestrial, and Space-Grown Materials

Improvement in the accuracy of electron-probe microanalysis (EPMA) has been accomplished by critical assessment of standards, correction algorithms, and mass absorption coefficient data sets. Experimental measurement of relative x-ray intensities at multiple accelerating potential highlights errors in the absorption coefficient. The factor method has been applied to the evaluation of systematic errors in the analysis of semiconductor and silicate minds. Accurate EPMA of Martian soil stimulant is necessary in studies that build on Martian rover data in anticipation of missions to Mars.

Carpenter, Paul↗

Quantitative Electron Probe Microanalysis: State of the Art

Quantitative electron-probe microanalysis (EPMA) has improved due to better instrument design and X-ray correction methods. Design improvement of the electron column and X-ray spectrometer has resulted in measurement precision that exceeds analytical accuracy. Wavelength-dispersive spectrometer (WDS) have layered-dispersive diffraction crystals with improved light-element sensitivity. Newer energy-dispersive spectrometers (EDS) have Si-drift detector elements, thin window designs, and digital processing electronics with X-ray throughput approaching that of WDS Systems. Using these systems, digital X-ray mapping coupled with spectrum imaging is a powerful compositional mapping tool. Improvements in analytical accuracy are due to better X-ray correction algorithms, mass absorption coefficient data sets,and analysis method for complex geometries. ZAF algorithms have ban superceded by Phi(pz) algorithms that better model the depth distribution of primary X-ray production. Complex thin film and particle geometries are treated using Phi(pz) algorithms, end results agree well with Monte Carlo simulations. For geological materials, X-ray absorption dominates the corretions end depends on the accuracy of mass absorption coefficient (MAC) data sets. However, few MACs have been experimentally measured, and the use of fitted coefficients continues due to general success of the analytical technique. A polynomial formulation of the Bence-Albec alpha-factor technique, calibrated using Phi(pz) algorithms, is used to critically evaluate accuracy issues and can be also be used for high 2% relative and is limited by measurement precision for ideal cases, but for many elements the analytical accuracy is unproven. The EPMA technique has improved to the point where it is frequently used instead of the petrogaphic microscope for reconnaissance work. Examples of stagnant research areas are: WDS detector design characterization of calibration standards, and the need for more complete treatment of the continuum X-ray fluorescence correction.

Carpernter, P. K.↗

Calibration Issues and Operating System Requirements for Electron-Probe Microanalysis

Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.

Carpenter, P.↗

Correlated Microanalysis of Cometary Organic Grains Returned by Stardust

Preliminary examination (PE) of samples returned from Comet 81P/Wild 2 by the NASA Stardust mission revealed a wide variety of carbonaceous samples [e.g. 1]. Carbonaceous matter is present as inclusions, rinds, and films in polyminerallic terminal particles [2-4], as carbon-rich particles along track walls [2, 5, 6], and as organic matter in aerogel around tracks [7, 8]. The organic chemistry of these samples ranges from purely aliphatic hydrocarbons to highly-aromatic material, often modified by various organic functional groups [2, 4, 5, 9-11]. Difficulty arises when interpreting the genesis of these carbonaceous samples, since contaminants could be introduced from the spacecraft [12], aerogel [1, 8], or during sample preparation. In addition, hypervelocity capture into aerogel may have heated cometary material in excess of 1000 C, which could have significantly altered the structure and chemistry of carbonaceous matter. Fortunately, much of this contamination or alteration can be identified through correlated microanalysis with transmission electron microscopy (TEM), scanning-transmission X-ray microscopy (STXM), and nanoscale secondary ion mass spectroscopy (SIMS).

DeGregorio, B. T.↗

Impacts on the Hubble Space Telescope Wide Field and Planetary Camera 2: Microanalysis and Recognition of Micrometeoroid Compositions

Postflight surveys of the Wide Field and Planetary Camera 2 (WFPC2) on the Hubble Space Telescope have located hundreds of features on the 2.2 by 0.8 m curved plate, evidence of hypervelocity impact by small particles during 16 years of exposure to space in low Earth orbit (LEO). The radiator has a 100 - 200 micron surface layer of white paint, overlying 4 mm thick Al alloy, which was not fully penetrated by any impact. Over 460 WFPC2 samples were extracted by coring at JSC. About half were sent to NHM in a collaborative program with NASA, ESA and IBC. The structural and compositional heterogeneity at micrometer scale required microanalysis by electron and ion beam microscopes to determine the nature of the impactors (artificial orbital debris, or natural micrometeoroids, MM). Examples of MM impacts are described elsewhere. Here we describe the development of novel electron beam analysis protocols, required to recognize the subtle traces of MM residues.

Kearsley, A. T.↗

Performance of a Commercial Silicon Drift Detector for X-ray Microanalysis

Silicon drift detectors (SDDs) are rapidly becoming the energy dispersive spectrometer of choice especially for scanning electron microscopy applications. The complementary features of large active areas (i.e., collection angle) and high count rate capability of these detector contribute to their popularity, as well as the absence of liquid nitrogen cooling of the detector. The performance of an EDAX Apollo 40 SDD on a JEOL 6500F SEM will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated Microanalysis of Cometary Organic Grains Returned by Stardust

Carbonaceous matter in Stardust samples returned from comet 81P/Wild 2 is observed to contain a wide variety of organic functional chemistry. However, some of this chemical variety may be due to contamination or alteration during particle capture in aerogel. We investigated six carbonaceous Stardust samples that had been previously analyzed and six new samples from Stardust Track 80 using correlated transmission electron microscopy (TEM), X-ray absorption near-edge structure spectroscopy (XANES), and secondary ion mass spectroscopy (SIMS). TEM revealed that samples from Track 35 containing abundant aliphatic XANES signatures were predominantly composed of cometary organic matter infilling densified silica aerogel. Aliphatic organic matter from Track 16 was also observed to be soluble in the epoxy embedding medium. The nitrogen-rich samples in this study (from Track 22 and Track 80) both contained metal oxide nanoparticles, and are likely contaminants. Only two types of cometary organic matter appear to be relatively unaltered during particle capture. These are (1) polyaromatic carbonyl-containing organic matter, similar to that observed in insoluble organic matter (IOM) from primitive meteorites, interplanetary dust particles (IDPs), and in other carbonaceous Stardust samples, and (2) highly aromatic refractory organic matter, which primarily constitutes nanoglobule-like features. Anomalous isotopic compositions in some of these samples also confirm their cometary heritage. There also appears to be a significant labile aliphatic component of Wild 2 organic matter, but this material could not be clearly distinguished from carbonaceous contaminants known to be present in the Stardust aerogel collector.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of the Component of Bias of X-Ray Microanalysis Related to Surface Relief of the Specimen

A semiempirical approach to the a priori evaluation of the effect of the surface relief on the results of X-ray spectral analysis of binary compounds is proposed. Dimensionless parameter k characterizing the effect of the relief on the intensity of intrinsic X-ray radiation is determined using the experimental data obtained for reference monocrystal specimens GaAs with known geometrical parameters of the relief.

36 MATERIALS SCIENCE↗

Low-Voltage Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of the Interface of Multilayer Polymer Composite

The morphology of the layer of polyelectrolyte complex, which is formed in the composite based on chitosan and sulfoethyl cellulose during the contact of a solution of one of them with a gel film of the other one, has been investigated by the low-voltage (≤3 kV) scanning electron microscopy. A technique for eliminating the effects related to charge accumulation on the dielectric film surface is proposed.

36 MATERIALS SCIENCE↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Integrated Microanalysis of Nanomaterials (06-ERI-001)

Comets--small extraterrestrial bodies of ice, dust, and small rocky particles--are considered the oldest, most primitive bodies in the solar system. They were thought to be composed of preserved interstellar particles from 4.6 billion years ago, when the Sun and the planets began to form from a primordial disk of dust and gas. The nonvolatile mineral components of comets are probably natural nanomaterials that include preserved interstellar dust as well as the first solids condensed in the solar system. Thus, comet samples may be considered as forensic 'time capsules' from the presolar molecular cloud and the earliest stages of solar system formation. Cometary material was captured in 2004, when the National Aeronautics and Space Administration's Stardust spacecraft flew through the coma of comet Wild as it neared the orbit of Mars. As Stardust approached the 4.5-kilometer-diameter comet, the spacecraft briefly extended a collector filled with lightweight aerogel glass foam to capture thousands of tiny particles. On January 15, 2006, the spacecraft ejected its sample return capsule onto the Utah desert southwest of Salt Lake City. Researchers at LLNL supported by this LDRD were part of a collaborative team investigating the mineralogical, chemical, and isotopic compositions of natural cometary nanomaterials from the Stardust mission using the unique array of analytical facilities at Livermore. The studies have provided provide new insight into cosmically primitive materials that will enable a better understanding of the earliest stages of disk accretion around stars. The skills and analysis techniques developed for the characterization of these natural nanomaterials are synergistic with several Livermore programmatic needs in the emerging fields of nanomaterials, nanotechnology and forensics. The Stardust samples are also ideal training materials for a new generation of young scientists using state-of-the-art analytical instruments at the Laboratory.

99 GENERAL AND MISCELLANEOUS↗

ELECTRON PROBE MICROANALYSIS OF IRRADIATED AND 1600°C SAFETY-TESTED AGR-1 TRISO FUEL PARTICLES WITH LOW AND HIGH RETAINED 110MAG

AGR-1 fuel Compact 4-3-3 achieved 18.63% FIMA and was exposed subsequently to a safety test at 1600°C. Two particles, AGR1-433-003 and AGR1-433-007, with measured-to-calculated 110mAg inventories of <22% and 100%, respectively, were selected for comparative electron microprobe analysis to determine whether the distribution or abundance of fission products differed proximally and distally from the deformed kernel in AGR1-433-003, and how this compared to fission product distribution in AGR1-433-007. On the deformed side of AGR1-433-003, Xe, Cs, I, Eu, Sr, and Te concentrations in the kernel buffer interface near the protruded kernel were up to six times higher than on the opposite, non-deformed side. At the SiC-inner pyrolytic carbon (IPyC) interface proximal to the deformed kernel, Pd and Ag concentrations were 1.2 wt% and 0.04 wt% respectively, whereas on the SiC-IPyC interface distal from the kernel deformation those elements measured 0.4 and 0.01 wt%, respectively. Palladium and Ag concentrations at the SiC-IPyC interface of AGR1-433-007 were 2.05 and 0.05 wt.%, respectively. Rare earth element concentrations at the SiC-IPyC interface of AGR1-433-007 were a factor of ten higher than at the SiC-IPyC interfaces measured in particle AGR1-433-003. Palladium permeated the SiC layer of AGR1-433-007 and the non-deformed SiC layer of AGR1-433-003.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗