Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Instrumentation for heavy-ion accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,872 records · Page 3

Collapse of magnetized white dwarfs as site of heavy-element formation and kilonova signal

We present the first end-to-end calculation connecting the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf to observable kilonova signatures, combining two-dimensional (2D) general-relativistic neutrino-magnetohydrodynamic simulations, followed by radiation hydrodynamics with in-situ nuclear network and 2D Monte Carlo radiative transfer with spatially resolved heating rates. Unlike all previous unmagnetized AIC models – which predicted proton-rich, $^{56}$Ni-dominated ejecta – strong magnetic fields eject ${\approx }\, 0.2\, \mathrm{ M}_\odot$ of neutron-rich material ($\langle Y_e \rangle \sim 0.24$) on dynamical time-scales, before neutrino irradiation can raise the electron fraction, enabling strong r-process nucleosynthesis up to and beyond the third peak. The resulting kilonova is lanthanide-rich ($X_{\rm lan} \approx 8~{{\ \rm per\ cent}}$) and dominated by near-infrared emission. We compute synthetic light curves in the Large Synoptic Survey Telescope and J ames Webb Space Telescope bands and find striking agreement, without parameter tuning, between the observations of AT 2023vfi/GRB 230307A and our broadband light curves for polar viewing angles. These results establish magnetized AIC as a viable channel for heavy r-process element production and a compelling progenitor candidate for long-duration gamma-ray bursts with kilonova signatures.

MHD

Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

Deng, Yi

ELECTRIC PROPULSION- A NEW TECHNOLOGY

Within the past 3 years, electric thrust devices have passed from the first exploratory feasibility experiments to the flight-engineered hardware phase. This rapid surge of development has been punctuated by equally rapid improvements in the performance figures of electrical thrust devices. The most spectacular advances were made in ion engine technology. Total energy expenditure per ion pair has gone from 35,000 ev in 1958 to about 600 ev at the present time leading to power utilization efficiencies of up to 80 per cent, depending upon the specific impulse. The percentage of the particles intercepting the accelerating and focusing electrodes has been reduced from more than 50 per cent in 1958 to less than 0.01 per cent at the present time. Great improvements in ion current per unit area have also been realized, leading to greater thrust "pressures."

ELECTRIC PROPULSION

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying [Pacific Northwest National Laborato

Nonlinear reversal of photoexcitation on the attosecond time scale improves ultrafast X-ray diffraction images

The complex refractive index of a material governs its light-matter interactions, with intense light fields enabling tailored nonlinear optical responses. In the X-ray regime, rapid photoionization limits the potential of nonlinear techniques by inducing irreversible electronic damage. Here we demonstrate that intense, sub-femtosecond X-ray pulses, shorter than typical Auger decay times, can partially reverse photoexcitation via stimulated emission near atomic resonances. By analyzing thousands of coherent diffraction patterns and ion spectra from neon nanoparticles exposed to sub-fs and 15-fs pulses, we observe enhanced X-ray diffraction alongside reduced energy absorption for sub-fs pulses. Theoretical modeling attributes this to dynamics akin to Rabi flopping that prolong the lifetime of resonant states and suppress electronic bleaching. These findings suggest that ultrashort, intense X-ray pulses enable active control of X-ray refractive index and damage pathways, opening avenues for improved high-resolution imaging and nonlinear spectroscopy in complex nanoscale systems.

Ulmer, Anatoli [Universität Hamburg (Germany)] (OR

On-Orbit Calibration Assessment of NOAA-21 VIIRS Thermal Emissive Bands and Implications for JPSS-4 VIIRS

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the NOAA-21 (N21) satellite has been successfully operating for over three years collecting valuable scientific measurements. A large suite of weather forecasting models and scientific research applications are supported with the VIIRS measurements from N21 combined with those acquired from the VIIRS instrument onboard the S-NPP and NOAA-20 spacecraft. Among the 22 VIIRS spectral bands, there are seven thermal emissive bands (TEB) covering the 3.7 to 12.2 µm spectral range at two different spatial resolutions. The VIIRS TEB detectors are calibrated onboard using a blackbody at a controlled temperature and a space view for background signal measurement. In this paper, we discuss the on-orbit performance of the N21 VIIRS TEB using various parameters such as the detector gain, noise, and offset. This on-orbit assessment provides critical insights into instrument behavior and calibration performance that will inform pre-launch testing and post-launch validation strategies for the upcoming JPSS-4 VIIRS mission scheduled for launch in 2027. The methodologies and lessons learned from characterizing the N21 TEB performance will enable more efficient and comprehensive radiometric assessment of the next VIIRS instrument. Specific focus is placed on identifying performance trends and anomaly signatures observed during the N21 commissioning phase that can enhance the JPSS4 instrument checkout procedures and accelerate the transition to routine on-orbit operations. The established performance baselines and uncertainty estimates will serve as an acceptance criterion for the JPSS-4 commissioning activities, ensuring mission readiness and data continuity for operational users.

Amit Angal

Agentic workflow enables the recovery of critical materials from complex feedstocks via selective precipitation

We present a multi-agentic workflow for critical materials recovery that deploys a series of AI agents and automated instruments to recover critical materials from produced water and magnet leachates. This approach achieves selective precipitation from real-world feedstocks using simple chemicals, accelerating the development of efficient, adaptable, and scalable separations to a timeline of days, rather than months and years.

Ritchhart, Andrew J.

Recommended Practice for Use of ExB Probes in Electric Propulsion Testing

An ExB probe is an electric propulsion plume diagnostic that has at its core a Wien filter. Ions entering the instrument experience perpendicular electric and magnetic fields and are filtered based on their velocity. While the ExB probe can be used to estimate the ion velocity distribution function, in the electric propulsion community, it is commonly used to measure species fractions. There are numerous probe designs, implementation and operation procedures, and data analysis approaches described and in use across the community. This paper provides recommendations and descriptions of best practices for design, implementation, and data analysis for the ExB probe, with a particular emphasis on Hall and ion thrusters. This work contributes to the broader community goal to standardize the use of diagnostics in electric propulsion testing.

ExB probe

Performance of AEA 80 Ah Battery Under GEO Profile

To date completed three Solar Dynamic Observatory SDO real-time eclipse seasons. Sony 18650HC has a low rate of capacity fade under GEO cycling regime. Real time test results correlate with accelerated GEO lifetest data and AEA capacity fade prediction tool. This data, together with other AEA test data, justify the SDO Project decision to baseline Lithium-Ion chemistry for the spacecraft battery.

Russel, N.

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Additively manufactured refractory high-entropy alloys with superior radiation resistance

Refractory high-entropy alloys (RHEAs) are promising candidates for next-generation nuclear and high-temperature applications. Among many approaches to manufacture RHEAs, additive manufacturing (AM) represents the most recent and advanced metal manufacturing method which allows near-net-shape manufacturing to reduce material waste and post-processing time. However, performance of AM RHEAs under complex irradiation conditions remains largely unexplored. Here, in this study, we demonstrate for the first time the response of directed energy deposition (DED) AM quaternary RHEAs (HfTaVW, CrTaVW) subjected to sequential dual-beam ion irradiation, consisting of helium pre-implantation followed by high-dose heavy ion bombardment. Compositions of DED AM RHEAs were selected using Monte Carlo (MC) simulations based on a cluster expansion (CE) Hamiltonian parameterized by density functional theory (DFT). Post-irradiation microstructural characterization revealed that the AM RHEA maintained remarkable stability, with suppressed helium bubble growth and reduced defect accumulation compared to conventional alloys. Even at high doses (∼100 dpa), the alloy exhibited no void swelling, a low density of dislocation loops, and no evidence of severe degradation. These results highlight the intrinsic ability of AM-derived microstructures and multicomponent chemistry to synergistically mitigate irradiation effects. Our findings establish AM RHEAs as a class of materials with superior resistance to radiation damage under conditions relevant to advanced fusion and fission environments and demonstrate the importance of sequential ion beam studies in evaluating their long-term performance.

36 MATERIALS SCIENCE

Review of Particle Physics

The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 3,200 new measurements from 903 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Most of the 118 reviews are updated, including many that are heavily revised.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Kondo effect in ferromagnetic quantum critical CeRh 6 ⁢Ge 4

The mechanism of a pressure-induced quantum critical point in the heavy fermion ferromagnet CeRh 6 ⁢Ge 4 has attracted interest, as ferromagnetic quantum criticality in a clean itinerant Ce compound is typically avoided. The localized versus itinerant character of the 4⁢𝑓 electrons is a key aspect for understanding this behavior. We investigated the electronic structure of the 4⁢𝑓 shell in CeRh 6 ⁢Ge 4 using core-level photoelectron and x-ray absorption spectroscopy, demonstrating the hybridization of Ce 4⁢𝑓 with the conduction electrons. Linearly polarized x-ray absorption reveals a temperature-dependent linear dichroism consistent with the crystal-electric-field sequence as inferred from the static susceptibility. This dichroism cannot be described by an ionic full-multiplet model alone, but is reproduced by including the Kondo effect within a single-impurity Anderson model in the noncrossing approximation. The Kondo effect mixes higher-lying crystal-field states into a resulting multiorbital ground state with 4⁢𝑓 occupancy, 𝑛 𝑓 ∼ 0.9. Deviations at low temperatures between the measured linear dichroism and calculated dichroism suggest an orbital-dependent Kondo effect. A scenario in which there is a multiorbital ground state and orbital-dependent Kondo hybridization should be a starting point for a model of pressure-induced criticality in CeRh 6 ⁢Ge 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]

Enhancing cathode composites with conductive alignment synergy for solid-state batteries

Enhancing transport and chemomechanical properties in cathode composites is crucial for the performance of solid-state batteries. Our study introduces the filler-aligned structured thick (FAST) electrode, which notably improves mechanical strength and ionic/electronic conductivity in solid composite cathodes. The FAST electrode incorporates vertically aligned nanoconducting carbon nanotubes within an ion-conducting polymer electrolyte, creating a low-tortuosity electron/ion transport path while strengthening the electrode’s structure. This design not only mitigates recrystallization of the polymer electrolyte but also establishes a densified local electric field distribution and accelerates the migration of lithium ions. The FAST electrode showcases outstanding electrochemical performance with lithium iron phosphate as the active material, achieving a high capacity of 148.2 milliampere hours per gram at 0.2 C over 100 cycles with substantial material loading (49.3 milligrams per square centimeter). This innovative electrode design marks a remarkable stride in addressing the challenges of solid-state lithium metal batteries.

Science & Technology - Other Topics

An integrated in-situ coordination strategy enabling high-performance layered cathodes for sodium-ion batteries

O3-type layered transition metal oxide cathodes hold tremendous potential in sodium-ion batteries (SIBs) due to their low cost and high energy density. However, the structure instability associated with detrimental phase transitions and severe interface parasitic reactions exacerbate the material's electrochemical performance degradation. Herein, we develop an integrated in-situ coordination strategy via heteroatomic modulation inducing coherent epitaxial layer to collaboratively enhance the overall framework robustness from surface to bulk. The theoretical calculation and multiple in/ex-situ characterizations demonstrate the charge density around oxygen is redistributed, which promotes the electron localization, thus widening the NaO 2 lattice space and accelerating the Na + transport dynamics. Furthermore, the formed strengthened oxygen bond energy effectively distributes the long-range coordination of Mn 3+ O 6 octahedron, thereby alleviating Jahn-Teller distortion and local stress. Importantly, the in-situ formed conformal buffer layer dramatically relieves the adverse interface side reactions, facilitating the construction of robust cathode-electrolyte interface, which ameliorate the whole structure stability of designed materials. Consequently, the optimized NFMZ@NZO-1.0 exhibits the excellent cycling stability with 80.2% capacity retention after 300 cycles at 1C, and delivers a high discharge capacity of 107.1 mAh g −1 at 10C. In conclusion, this distinctive coupling strategy provides valuable insights for developing high-performance layered cathode materials in SIBs.

Coherent epitaxial layer