Modeling of SSME fuel preburner ASI
The Augmented Spark Ignitor (ASI) is a LOX/H2/electrical spark system that functions as an ignition source and sustainer for stable combustion. It is used in the SSME preburner combustor, the SSME main combustion chamber, the J-1 and J-2 engines as well as proposed designs of the Space Transportation Main Engine (STME) main combustor and gas generators. In the SSME it is a long circular cylindrical chamber located along the Main Combustor centerline with a truncated conical dome at the top, which contains two oblique LOX injection ports and two spark plugs offset at 90 degrees. Hydrogen injection is through a number of nearly tangential slots downstream which creates a swirl flow intended to cool the AS1 chamber walls. Past incidents of erosion of the AS1 spark plugs have often led to the need for replacement of these very costly devices. Thus it is desirable to understand the complex reactive flow field within the AS1 both during the initial ignition transient and during the main stage steady state combustion (no sparking).