SEARCH · Engineering Papers
Results for “Focuses”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Histological evaluation of high-intensity focused ultrasound with lower-intensity focused ultrasound pre-exposure on the treatment of rabbit VX2 liver tumors
This study was to evaluate the effect of pre-exposure lower-intensity focused ultrasound(US), or LIFU, in high-intensity focused ultrasound(HIFU) ablation of rabbit VX2 liver tumors . Liver VX2 tumor models were established in 30 rabbits, which were divided randomly into two groups. The liver tumors of rabbits in Group A underwent single HIFU ablation; those in Group B were given LIFU exposure before HIFU treatment. Five rabbits from each of the two groups were sacrificed at 0 hours, 3 days, and 7 days after HIFU ablation. Tissue samples that included targeted and short-range sounding (s-RS, within 5 mm of the targeted) and far-range sounding (f-RS, more than 5 mm of the targeted) tissues were observed using light microscope and transmission electron microscopy. The histological examination indicated that not only the targeted tumor cells became irreversible damage, but also the short-range sounding tumors were severely damaged by the HIFU with LIFU pre-exposure in group B. It is concluded that LIFU pre-exposure can enhance the effects of HIFU ablation on the destruction of cell ultrastructures and can enlarge the region of HIFU ablation.
DESI 2024: Constraints on physics-focused aspects of dark energy using DESI DR1 BAO data
Baryon acoustic oscillation data from the first year of the Dark Energy Spectroscopic Instrument (DESI) provide near percent-level precision of cosmic distances in seven bins over the redshift range z=0.1–4.2. Here, this paper is the follow-up to the original DESI BAO cosmology paper [A. G. Adame et al. (DESI Collaboration), arXiv:2404.03002], which considered the conventional w 0 w a cold dark matter (CDM) model. We use the novel DESI data, together with other cosmic probes, to constrain the background expansion history using some well-motivated physical classes of dark energy. In particular, we explore three physics-focused behaviors of dark energy from the equation of state and energy density perspectives: the thawing class (matching many simple quintessence potentials), emergent class (where dark energy comes into being recently, as in phase transition models), and mirage class [where phenomenologically the distance to cosmic microwave background (CMB) last scattering is close to that from a cosmological constant Λ despite dark energy dynamics]. All three classes fit the data at least as well as Λ CDM, and indeed can improve on it by Δχ 2 ≈ –5 to –17 for the combination of DESI BAO with CMB and supernova data while having one more parameter. The mirage class does essentially as well as w 0 w a CDM and exhibits moderate to strong Bayesian evidence preference with respect to Λ CDM. These classes of dynamical behaviors highlight worthwhile avenues for further exploration into the nature of dark energy.
Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams
A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.
A laboratory nanoseismological study on deep-focus earthquake micromechanics
Global earthquake occurring rate displays an exponential decay down to ~300 km and then peaks around 550 to 600 km before terminating abruptly near 700 km. How fractures initiate, nucleate, and propagate at these depths remains one of the greatest puzzles in earth science, as increasing pressure inhibits fracture propagation. We report nanoseismological analysis on high-resolution acoustic emission (AE) records obtained during ruptures triggered by partial transformation from olivine to spinel in Mg 2 GeO 4 , an analog to the dominant mineral (Mg,Fe) 2 SiO 4 olivine in the upper mantle, using state-of-the-art seismological techniques, in the laboratory. AEs’ focal mechanisms, as well as their distribution in both space and time during deformation, are carefully analyzed. Microstructure analysis shows that AEs are produced by the dynamic propagation of shear bands consisting of nanograined spinel. These nanoshear bands have a near constant thickness (~100 nm) but varying lengths and self-organize during deformation. This precursory seismic process leads to ultimate macroscopic failure of the samples. Several source parameters of AE events were extracted from the recorded waveforms, allowing close tracking of event initiation, clustering, and propagation throughout the deformation/transformation process. AEs follow the Gutenberg-Richter statistics with a well-defined b value of 1.5 over three orders of moment magnitudes, suggesting that laboratory failure processes are self-affine. The seismic relation between magnitude and rupture area correctly predicts AE magnitude at millimeter scales. A rupture propagation model based on strain localization theory is proposed. Future numerical analyses may help resolve scaling issues between laboratory AE events and deep-focus earthquakes.
THE FIRST FOCUSED HARD X-RAY IMAGES OF THE SUN WITH NuSTAR
We present results from the the first campaign of dedicated solar observations undertaken by the Nuclear Spectroscopic Telescope ARray ( NuSTAR ) hard X-ray (HXR) telescope. Designed as an astrophysics mission, NuSTAR nonetheless has the capability of directly imaging the Sun at HXR energies (>3 keV) with an increase in sensitivity of at least two magnitude compared to current non-focusing telescopes. In this paper we describe the scientific areas where NuSTAR will make major improvements on existing solar measurements. We report on the techniques used to observe the Sun with NuSTAR , their limitations and complications, and the procedures developed to optimize solar data quality derived from our experience with the initial solar observations. These first observations are briefly described, including the measurement of the Fe K-shell lines in a decaying X-class flare, HXR emission from high in the solar corona, and full-disk HXR images of the Sun.
Particle-in-cell modeling for MJ scale dense plasma focus with varied anode shape
Megajoule scale dense plasma focus (DPF) Z-pinches with deuterium gas fill are compact devices capable of producing 10{sup 12} neutrons per shot but past predictive models of large-scale DPF have not included kinetic effects such as ion beam formation or anomalous resistivity. We report on progress of developing a predictive DPF model by extending our 2D axisymmetric collisional kinetic particle-in-cell (PIC) simulations from the 4 kJ, 200 kA LLNL DPF to 1 MJ, 2 MA Gemini DPF using the PIC code LSP. These new simulations incorporate electrodes, an external pulsed-power driver circuit, and model the plasma from insulator lift-off through the pinch phase. To accommodate the vast range of relevant spatial and temporal scales involved in the Gemini DPF within the available computational resources, the simulations were performed using a new hybrid fluid-to-kinetic model. This new approach allows single simulations to begin in an electron/ion fluid mode from insulator lift-off through the 5-6 μs run-down of the 50+ cm anode, then transition to a fully kinetic PIC description during the run-in phase, when the current sheath is 2-3 mm from the central axis of the anode. Simulations are advanced through the final pinch phase using an adaptive variable time-step to capture the fs and sub-mm scales of the kinetic instabilities involved in the ion beam formation and neutron production. Validation assessments are being performed using a variety of different anode shapes, comparing against experimental measurements of neutron yield, neutron anisotropy and ion beam production.
Implementation of focused ion beam (FIB) system in characterization of nuclear fuels and materials
Not Available
Fully kinetic simulations of megajoule-scale dense plasma focus
Dense plasma focus (DPF) Z-pinch devices are sources of copious high energy electrons and ions, x-rays, and neutrons. Megajoule-scale DPFs can generate 10{sup 12} neutrons per pulse in deuterium gas through a combination of thermonuclear and beam-target fusion. However, the details of the neutron production are not fully understood and past optimization efforts of these devices have been largely empirical. Previously, we reported on the first fully kinetic simulations of a kilojoule-scale DPF and demonstrated that both kinetic ions and kinetic electrons are needed to reproduce experimentally observed features, such as charged-particle beam formation and anomalous resistivity. Here, we present the first fully kinetic simulation of a MegaJoule DPF, with predicted ion and neutron spectra, neutron anisotropy, neutron spot size, and time history of neutron production. The total yield predicted by the simulation is in agreement with measured values, validating the kinetic model in a second energy regime.
Focusing, collimation and flux throughput at the IMCA-CAT bending-magnet beamline at the Advanced Photon Source
Abstract not provided
Focused Ion Beam Fabrication of LiPON-based Solid-state Lithium-ion Nanobatteries for In Situ Testing
Solid-state electrolytes are a promising replacement for current organic liquid electrolytes, enabling higher energy densities and improved safety of lithium-ion (Li-ion) batteries. However, a number of setbacks prevent their integration into commercial devices. The main limiting factor is due to nanoscale phenomena occurring at the electrode/electrolyte interfaces, ultimately leading to degradation of battery operation. These key problems are highly challenging to observe and characterize as these batteries contain multiple buried interfaces. One approach for direct observation of interfacial phenomena in thin film batteries is through the fabrication of electrochemically active nanobatteries by a focused ion beam (FIB). As such, a reliable technique to fabricate nanobatteries was developed and demonstrated in recent work. Herein, a detailed protocol with a step-by-step process is presented to enable the reproduction of this nanobattery fabrication process. In particular, this technique was applied to a thin film battery consisting of LiCoO 2 /LiPON/a-Si, and has further been previously demonstrated by in situ cycling within a transmission electron microscope.
Focused-image holography - A method for restoring the third dimension in the recording of conventionally-focused photographs.
Holographic technique for restoration of third- dimension information in recording of conventionally focused photographs
Comparison of SOFC Cathode Microstructure Quantified using X-ray Nanotomography and Focused Ioni Beam-scanning Electron Microscopy
X-ray nanotomography and focused ion beam scanning electron microscopy (FIB-SEM) have been applied to investigate the complex 3D microstructure of solid oxide fuel cell (SOFC) electrodes at spatial resolutions of 45 nm and below. The application of near edge differential absorption for x-ray nanotomography and energy selected backscatter detection for FIB-SEM enable elemental mapping within the microstructure. Using these methods, non-destructive 3D x-ray imaging and FIB-SEM serial sectioning have been applied to compare three-dimensional elemental mapping of the LSM, YSZ, and pore phases in the SOFC cathode microstructure. The microstructural characterization of an SOFC cathode is reported based on these measurements. The results presented demonstrate the viability of x-ray nanotomography as a quantitative characterization technique and provide key insights into the SOFC cathode microstructure.
Mechanisms of nanorod growth on focused-ion-beam-irradiated semiconductor surfaces: Role of redeposition
We have examined the formation and evolution of irradiation-induced nanorod (NR) growth through a comparison of focused-ion-beam irradiation of InSb wafers and InSb/GaAs heterostructures. Above a critical ion dose, cone-shaped NRs capped with In islands form on both InSb surfaces. For InSb wafers, the NR base diameter increases with ion energy. In the case of InSb/GaAs heterostructures, as the milled depth approaches the InSb/GaAs interface, the cone-shaped NRs transition to capless NRs with a truncated cone shape. These results suggest a growth mechanism in which both the NR cap and body are supplied by redeposition of atoms sputtered from InSb.
Focused-ion-beam induced damage in thin films of complex oxide BiFeO{sub 3}
An unexpected, strong deterioration of crystal quality is observed in epitaxial perovskite BiFeO{sub 3} films in which microscale features have been patterned by focused-ion-beam (FIB) milling. Specifically, synchrotron x-ray microdiffraction shows that the damaged region extends to tens of μm, but does not result in measureable changes to morphology or stoichiometry. Therefore, this change would go undetected with standard laboratory equipment, but can significantly influence local material properties and must be taken into account when using a FIB to manufacture nanostructures. The damage is significantly reduced when a thin metallic layer is present on top of the film during the milling process, clearly indicating that the reduced crystallinity is caused by ion beam induced charging.
Atomic-scale thermocapillary flow in focused ion beam milling
Focused ion beams provide a means of nanometer-scale manufacturing and material processing, which is used for applications such as forming nanometer-scale pores in thin films for DNA sequencing. We investigate such a configuration with Ga{sup +} bombardment of a Si thin-film target using molecular dynamics simulation. For a range of ion intensities in a realistic configuration, a recirculating melt region develops, which is seen to flow with a symmetrical pattern, counter to how it would flow were it driven by the ion momentum flux. Such flow is potentially important for the shape and composition of the formed structures. Relevant stress scales and estimated physical properties of silicon under these extreme conditions support the importance thermocapillary effects. A flow model with Marangoni forcing, based upon the temperature gradient and geometry from the atomistic simulation, indeed reproduces the flow and thus could be used to anticipate such flows and their influence in applications.
A new class of focusing crystal shapes for Bragg spectroscopy of small, point-like, x-ray sources in laser produced plasmas
Explore the source record for details and available documents.