High strength, wire-reinforced electroformed structures

Using half-round reinforcing wires, electrodeposited matrix metal readily fills spaces between wires in intimate contact with wires and without voids. Procedure combines advantages of electroforming with high-strength of commonly available wire to produce non-welded shell structures for high pressure uses.

Kazaroff, J. M.

Graphical method for predicting life of a rocket thrust chamber with half-hard zirconium-copper liner and electroformed nickel closeout

A method for estimating the life of a regeneratively cooled rocket thrust chamber was developed and is based on the hot-gas wall temperature and the temperature difference between the hot-gas wall and the outside surface of the closeout. This method permits a quick estimate of the life of a thrust chamber when design changes or test-cycle variations are considered. Strain range and life are presented graphically as functions of these temperature parameters for a typical high-performance rocket thrust chamber with a half-hard zirconium-copper liner and an electroformed nickel closeout.

Kasper, H. J.

Study of high performance alloy electroforming

The first series of heat treated nickel manganese alloys are tested for mechanical properties at temperatures of 148.9 C (300 F) and 260 C (500 F). All material receives the same heat treatment in order to provide a common basis for comparison of results. Mechanical property performance improves with increasing manganese content in the alloy. Although all manganese bearing alloy is significantly superior to conventional electroformed nickel, samples containing over 3000 ppm manganese display outstanding ultimate and yield strengths while maintaining reasonably satisfactory ductility. Alloy containing over 6000 ppm of manganese is very competitive to Inconel 718 (mill annealed and age hardened) at all temperatures of interest, although ductility is not as great in the electrodeposited counterpart.

Malone, G. A.

Study of high performance alloy electroforming

Nickel-manganese electroformed specimens and nickel-cobalt-manganese samples were heat treated at 343 C (650 F) for comparison of room temperature ductility with that observed for alloys heat treated at 315.6C (600 F). All heat treatments were for 24 hours. This heat treatment temperature increase generally did not result in significant improvements in ductility. However, increases in yield strength - with slight decreases in tensile strengths - were noted for the nickel-manganese and nickel-cobalt-manganese alloys. For the case of employing fairly high manganese contents in the electrolyte and countering ensuing high tensile stress in the alloy by saccharin additions to the bath, it was noted that nickel-manganese alloys with over 0.4% by weight manganese retained high ultimate and yield strengths after the 343 C (650 F) heat treatment for 24 hours. Elongations were still lower than desired. For alloys with less than 0.4% by weight manganese this heat treatment provided excellent ductility, but very significant reductions in ultimate and yield strengths were noted.

Malone, G. A.

Study of high performance alloy electroforming

The nickel-manganese experimental electrolyte was hydrogen peroxide treated and carbon purified for removal of residual sodium saccharin and related organic decomposition products from the plating of previous test panels. The saccharin additive was used to reduce stress where high concentrations of manganese and high pulse peak current densities were used. A large quantity of nickel-manganese alloy plates containing 0.35 to 0.40 percent by weight manganese was electroformed for testing to supply data for a mechanical property data table. The aluminum billet required for the machining of the subscale SSME main combustion chamber was acquired.

Malone, G. A.

Electroform replication used for multiple X-ray mirror production

The electroforming technique for producing X-ray mirrors is described, and results of X-ray tests performed on copies made from a simple conical mandrel are reported. The design of the mandrel is depicted and the total reflectivity as well as the full-wave half modulation resolution are shown as a function of energy. The reported work has improved on previous studies by providing smaller grazing angles, making measurements at higher energies, producing about four times as many replicas from one mandrel, and obtaining better angular resolution.

Kowalski, M. P.

Electroformed grazing incidence X-ray mirrors for a mirror array telescope

Grazing incidence Wolter type I mirrors for higher-energy X-rays have been replicated from two superpolished mandrels by electroforming. Single mirrors and a nested pair were tested with 1.5- and 6.4-keV X-rays, and their subminute of arc resolution and reflectivity close to the theoretical values are confirmed. The design of the mandrels, the mirror mounting scheme, and results of the X-ray test are presented. The microroughnesses of the mirrors measured using an optical profilometer were compared with the X-ray test results.

Ulmer, Melville P.

X-ray and optical profiler analysis of electroformed X-ray optics

Electroformed grazing incidence mirrors were tested with X-rays and were measured with an optical profiler. Their total effective areas are greater than about 70 percent of the theoretical values both for 1.5- and 6.4-keV X-rays. The half-power diameters are less than about 2 min of arc at 1.5 keV. A design of the mirror array telescope for high energies which has a total effective area of about 1000 sq cm for 7-keV X-rays is presented.

Matsui, Yutaka

Electroforming Repair Of Adjacent Unconnected Layers

Procedure devised to improve repair of hole through nickel-alloy layer and nickel layer that are parts of larger structure, and separated by thin gap. Involves established techniques of electroforming, grinding, filling, and masking. Conductive coat serves as weak fracture layer between repaired layers.

Burbach, Daniel J.

Electroform Welding

Electroform welding used to join variety of parts without addition of detrimental heat. Technique developed so large and/or complexly shaped parts joined without degrading properties of materials. Commercial uses include joining dissimilar alloys. Beneficial for suppression of distortion or maintenance of close tolerances in precise components.

Kazaroff, John M.

Mach 5 electroformed nickel nozzle refurbishment FNAS investigation of ultra-smooth surfaces

This task is in support of the Quiet Hypersonic Wind Tunnel effort currently in effect at NASA Langley Research Center, VA. A laminar flow wind tunnel nozzle has been previously fabricated by electroforming pure nickel over a machined and polished two piece stainless steel mandrel. The mandrel was removed leaving the replicate nozzle surface. The nozzle was then pressed into a heavy stainless steel jacket for mounting features and rigidity. The original nickel surface was a replication of the polished mandrel but had degraded due to oxidation. The inside surface requirements are very stringent in order to achieve laminar or quiet flow at the desired pressure and temperature for the specific design of Mach 5. The throat area of the axisymmetric device must have a surface finish with no defects greater than 16 microinches. This requires an rms average background of about four microinches or better for inspection purposes. A coating of nickel-phosphorous alloy was applied by catalytic deposition and then the inside of the nozzle was polished retaining dimensional and surface finish tolerances as specified per drawings supplied. Since the unit is not an optical component, conventional optical inspection methods for surface finish and figure are not readily achieved. Measurements were made using surface profilometry.

Rood, Robert

Electroformed Nickel Mirrors for the Next Generation Space Telescope

This paper summarizes the work to date on a novel mirror fabrication technique being developed at the Marshall Space Flight Center for potential use on the Next Generation Space Telescope (NGST). This technique involves forming an extremely lightweight mirror by electroplating nickel and nickel based alloys onto a highly polished precision mandrel. The resulting mirror shell can then be backed up with or attached to a lightweight structure to produce a mirror element that is on the order of 15 kg/sq m areal density. Since the mirrors are fabricated from a mandrel (or master), subsequent mirrors can be made with very high economy; this technique is particularly suited to segmented mirrors schemes whereby large apertures are achieved through the deployment of smaller segments. Control of the electroplating process is the key element for producing high quality optics; bath chemistry and real time control of the plating current density yields uniform grained electroforms with zero residual stress. To accomplish this, a special electronic sensor was developed whereby the residual stress can be monitored as the nickel is electrolytically deposited. This information is used in a feedback loop to modulate current density which, in turn, directly governs the residual stress. Details pertaining to this and other aspects of the fabrication of a half meter mirror will be published along with test results and metrology data.

Redmon, John W.

Replication of Low Density Electroformed Normal Incidence Optics

Replicated electroformed light-weight nickel alloy mirrors can have high strength, low areal density (<3kg/m2), smooth finish, and controllable alloy composition. Progress at NASA MSFC SOMTC in developing normal incidence replicated Nickel mirrors will be reported.

Ritter, Joseph M.