At least 55 records · Page 3

Passenger Survey - Washington DC Metrorail - 2012

The primary purposes of the survey were to update ridership by the jurisdiction of residence for use in Metrorail’s operating subsidy allocation and to collect demographic, travel, and access data for Title VI compliance, system planning, and operation analyses. It was not a customer opinion survey; the focus was on ridership and travel characteristics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Metrobus Survey - Washington DC - 2014

The primary purposes of the survey were to update ridership by the jurisdiction of residence for use in Metrobus’ operating subsidy allocation and to collect demographic, travel, and access data for Title VI compliance, system planning, and operation analyses. It was not a customer opinion survey; the focus was on ridership and travel characteristics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

NEXUS-DC: Nuclear Energy eXpedition for US Data Centers [Slides]

This presentation covers the growing interest in utilizing nuclear power to satisfy the increasing energy demands of data centers in the United States, emphasizing the factors that accelerate reactor deployment. It addresses clean and reliable energy needs, highlights the importance of power supply redundancy for reliability, and discusses challenges and solutions related to cooling, waste heat reuse, and techno-economics. Additionally, it includes a strength, weakness, opportunities and threat analysis and emphasizes community engagement and collaboration for accelerating regulatory approvals and reactor deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Scalable Hybrid Large-Scale dc-ac Grid Analysis Methods (Phase II)

The goals of the project included the identification and evaluation of a voltage source converter multiterminal high-voltage direct current (VSC-MTdc) system architecture suitable for a high amount of power transfer through long transmission lines.

24 POWER TRANSMISSION AND DISTRIBUTION

DC Fast Charging Test Procedures

This report has been drafted as an initial effort to develop a standardized test procedure for DCFC for LD EVs. The proposed test procedures are designed to be time-efficient, aligned with EV discharge tests, and practical to implement, thereby minimizing the testing and computational efforts required by OEMs and testing authorities.

33 ADVANCED PROPULSION SYSTEMS

EV-EVSE Fault Study: An Analysis of Thermal Events Caused by Electrical Faults during DC Charging

This report outlines multiple avenues of analysis of electrical faults associated with electric vehicles (EVs) during charging, focusing specifically on the interactions between EVs and EV supply equipment (EVSE). Key concerns include the identification and mitigation of overtemperature events that can result in fires, which are commonly initiated by localized heating of connectors, wiring, or high-impedance fault current paths.

42 - ENGINEERING

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS

Navigating the Use of Direct Current in Residential Settings: Merits and Obstacles

This review paper provides an in-depth analysis of the role of Direct Current (DC) power systems in residential settings, focusing on their safety, efficiency, and environmental advantages. It recognizes the significant contribution of the residential sector to global carbon dioxide emissions and explores how DC power systems can help mitigate these effects. The paper traces the historical evolution of DC power, its resurgence with renewable energy technologies, and the advancements in power electronics that facilitate its integration. Emphasizing the efficiency and safety benefits, especially in low-voltage applications, the paper highlights the seamless integration of DC systems with inherently DC-generating renewable sources like solar PV and wind. The review discusses the critical role of converter technologies in the transition to DC power and examines the compatibility of DC systems with energy storage solutions, underscoring their potential for enhanced energy management. It also addresses the environmental impacts of adopting DC power, aligning with global carbon reduction efforts. The paper analyzes regional case studies, exploring practical applications and outcomes, and addresses challenges such as the need for standardization. It concludes with recommendations for stakeholders and future research directions, emphasizing the economic, technological, and environmental aspects of DC power systems. Overall, the paper presents DC power as a viable and sustainable option for residential energy conservation, contingent upon ongoing technological progress, supportive policies, and standardization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting