Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation of Uranyl Perchlorate Anion Complexes in the Gas Phase via Infrared Multiphoton Dissociation and Collision‐Induced Dissociation

The infrared multiphoton dissociation spectrum of the gas-phase uranyl perchlorate anion ([UO 2 (ClO 4 ) 3 ] − ) was measured. Here, the asymmetric uranyl stretch lies somewhere between 930 and 1030 cm −1 , though it could not be deconvoluted from a closely located perchlorate stretching mode. The experimentally measured spectrum was in good agreement with spectra calculated using density functional theory with the B3LYP and TPSSh functionals and Grimme's D3 dispersion corrections with Becke–Johnson damping. The calculations suggest that the asymmetric uranyl stretch lies in the range of 970–980 cm −1 , about 20–30 cm −1 higher than for the analogous uranyl trinitrato complex and consistent with perchlorate as a weaker ligand than nitrate. Like the uranyl trinitrato anion, fragmentation of [UO 2 (ClO 4 ) 3 ] − by collision-induced dissociation resulted in loss of a ClO 3 • radical to form [UO 3 (ClO 4 ) 2 ] − . Infrared multiphoton dissociation measurements of [UO 3 (ClO 4 ) 2 ] − indicate that the structure of the product ion has an O − ligand bound to the uranyl in a T-arrangement and two perchlorate ligands, matching the findings from uranyl nitrato complexes. The uranyl stretch in this complex was slightly separated from the perchlorate modes and was measured at 906 cm −1 , slightly higher than for the analogous nitrate complex, again consistent with perchlorate as a weaker ligand than nitrate in the gas phase.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{cos θ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in 136 Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neu- trinoless double beta decay search. The analysis considers the combination of 271.6 days of 136 Xe-enriched data and 208.9 days of 136Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50 ± 0.01 kg of 136 Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the $T^{0v}_{1/2} > 5.5 \times 10^{23} - 1.3 \times 10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diverse events have transferred genes for edible seaweed digestion from marine to human gut bacteria

Humans harbor numerous species of colonic bacteria that digest fiber polysaccharides in commonly consumed terrestrial plants. More recently in history, regional populations have consumed edible macroalgae seaweeds containing unique polysaccharides. It remains unclear how extensively gut bacteria have adapted to digest these nutrients. Here, in this work, we show that the ability of gut bacteria to digest seaweed polysaccharides is more pervasive than previously appreciated. Enrichment-cultured Bacteroides harbor previously discovered genes for seaweed degradation, which have mobilized into several members of this genus. Additionally, other examples of marine bacteria-derived genes, and their mobile DNA elements, are involved in gut microbial degradation of seaweed polysaccharides, including genes in gut-resident Firmicutes. Collectively, these results uncover multiple separate events that have mobilized the genes encoding seaweed-degrading-enzymes into gut bacteria. This work further underscores the metabolic plasticity of the human gut microbiome and global exchange of genes in the context of dietary selective pressures.

42 ENGINEERING↗

OzDES Reverberation Mapping of Active Galactic Nuclei: Final Data Release, Black-Hole Mass Results, & Scaling Relations

Over the last decade, the Australian Dark Energy (OzDES) collaboration has used Reverberation Mapping to measure the masses of high redshift supermassive black holes. Here we present the final review and analysis of this OzDES reverberation mapping campaign. These observations use 6-7 years of photometric and spectroscopic observations of 735 Active Galactic Nuclei (AGN) in the redshift range 0.13-3.85 and bolometric luminosity range 44.3 - 47.5 erg/s. Both photometry and spectra are observed in visible wavelengths, allowing for the physical scale of the AGN broad line region to be estimated from reverberations of the H{̱e̱ṯa̱}̱, MgII and CIV emission lines. We successfully use reverberation mapping to constrain the masses of 62 super-massive black holes, and combine with existing data to fit a power law to the lag-luminosity relation for the H{̱e̱ṯa̱}̱ and MgII lines with a scatter of ~0.25 dex, the tightest yet identified, fit specifically for consistency with high redshift AGN. We fit a similarly constrained relation for CIV, resolving a tension with the low luminosity literature AGN by accounting for selection effects arising from finite survey length. We also examine the impact of emission line width and luminosity (related to accretion rate) in reducing the scatter of these scaling relationships and find no significant improvement over the lag-only approach for any of the three lines. Using these relations, we further estimate the masses and accretion rates of 246 AGN with single epoch methods. We also use these relations to estimate the relative sizes of the H{̱e̱ṯa̱}̱, MgII and CIV emitting regions. In short, we provide a comprehensive benchmark of high redshift AGN reverberation mapping at the close of this most recent generation of surveys, including light curves, time-delays, and a set of significantly improved radius-luminosity relations for use with high-redshift populations.

McDougall, Hugh [Queensland U.]↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TMTpro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level

Multiplexed proteomics is a powerful tool to assay cell states in health and disease, but accurate quantification of relative protein changes is impaired by interference from co-isolated peptides. Most widely, this issue is alleviated by MS3-based quantification, reducing sensitivity and requiring specialized instrumentation. An alternative approach is quantification by complementary ions, which allows accurate and precise multiplexed quantification at the MS2 level and is compatible with the most widely distributed instruments. However, complementary ions of the popular TMT tag form inefficiently and plexing is limited to five channels. In this work, we evaluate and optimize complementary ion quantification for the recently released TMTPro tag, which increases plexing capacity to 8 channels (TMTProC). We find that the beneficial fragmentation properties increase quantification signal five-fold compared to TMT. This increased sensitivity results in ~50% more proteins quantified compared to TMTPro-MS3 and even slightly outperforms TMTPro-MS2. Furthermore, TMTProC quantification is more accurate than TMTPro-MS2 and even superior to TMTPro-MS3. To demonstrate the power of TMTProC, we analyzed a human and yeast interference sample and were able to quantify 13,290 proteins in 24 fractions. Thus, TMTProC advances multiplexed proteomics data quality and widens access to accurate multiplexed proteomics beyond laboratories with MS3-capable instrumentation.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring Fluoropyridine Electrolytes in Li–S Batteries: Balancing Performance and Stability across Temperatures

A novel high-donor 3-fluoropyridine (3FPy) electrolyte has been introduced for use in Li-S batteries, demonstrating an inhibition effect on the polysulfide shuttle, even without the addition of LiNO 3 . In this study, fluoropyridine electrolytes, including 2-fluoropyridine (2FPy) and 3FPy electrolytes, are studied using electrochemical analysis, mass spectrometry (MS), and high-performance liquid chromatography (HPLC) methods. Collision-induced dissociation spectra revealed that Li + preferentially solvates with different fluoropyridines, with 2FPy exhibiting a stronger interaction due to ortho-fluorine's influence, compared to 4FPy and 3FPy. However, MS and HPLC analyses showed that 2FPy is reactive with polysulfides, while 3FPy offers high solubility for polysulfides and sulfur without reacting with them at room temperature. Further, despite 3FPy performing well at room temperature, further electrochemistry studies at elevated (60 °C) and reduced (0 °C) temperatures reveal the challenges. At high temperatures, LiNO 3 is essential to suppress the polysulfide shuttle; and at low temperatures, the performance with the 3FPy electrolyte significantly lags behind that of the ether-based electrolyte.

25 ENERGY STORAGE↗

Identification of Unique Fragmentation Patterns of Fentanyl Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls uniquely exhibited two baseline separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. In conclusion, our new observations on the IM and MS/MS properties of fentanyls can be exploited to positively identify them as fentanyls without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence imaging of individual ions and molecules in pressurized noble gases for barium tagging in 136Xe

Abstract The imaging of individual Ba 2+ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba 2+ ion imaging inside a high-pressure xenon gas environment. Ba 2+ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1 × 1 cm 2 located inside 10 bar of xenon gas. This form of microscopy represents key ingredient in the development of barium tagging for neutrinoless double beta decay searches in 136 Xe. This also provides a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface to enable bottom-up design of catalysts and sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-technique approach to understanding delithiation damage in LiCoO2 thin films

Abstract We report on the delithiation of LiCoO 2 thin films using oxalic acid (C 2 H 2 O 4 ) with the goal of understanding the structural degradation of an insertion oxide associated with Li chemical extraction. Using a multi-technique approach that includes synchrotron radiation X-ray diffraction, scanning electron microscopy, micro Raman spectroscopy, photoelectron spectroscopy and conductive atomic force microscopy we reveal the balance between selective Li extraction and structural damage. We identify three different delithiation regimes, related to surface processes, bulk delithiation and damage generation. We find that only a fraction of the grains is affected by the delithiation process, which may create local inhomogeneities. However, the bulk delithiation regime is effective to delithiate the LCO film. All experimental evidence collected indicates that the delithiation process in this regime mimics the behavior of LCO upon electrochemical delithiation. We discard the formation of Co oxalate during the chemical extraction process. In conclusion, the chemical route to Li extraction provides additional opportunities to investigate delithiation while avoiding the complications associated with electrolyte breakdown and simplifying in-situ measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadening the scope of high structural dimensionality nanomaterials using pyridine-based curcuminoids

We present a new heteroditopic ligand (3pyCCMoid) that contains the typical skeleton of a curcuminoid (CCMoid) decorated with two 3-pyridyl groups. The coordination of 3pyCCMoid with ZnII centres results in a set of novel coordination polymers (CPs) that display different architectures and dimensionalities (from 1D to 3D). Our work analyses how synthetic methods and slight changes in the reaction conditions affect the formation of the final materials. Great efforts have been devoted toward understanding the coordination entities that provide high dimensional systems, with emphasis on the characterization of 2D materials, including analyses of different types of substrates, stability and exfoliation in water. Here, we foresee the great use of CCMoids in the field of CPs and emphasize 3pyCCMoid as a new-born linker.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Barium ion sensing with IPG K + molecular probes

Fluorophores covalently bound to azacrown ether ionophores can be assembled into sensitive turn-on chemosensors. The size specificity and electron-rich nature of the ionophore's binding domain contribute to both selectivity and strong turn-on fluorescence sensing by various mechanisms when properly constructed. Aza-18-crown-6 ethers are quite selective for binding to K + and Ba 2+ , yet the more electron-withdrawing dicationic nature of barium imposes a larger electronic effect on turn-on fluorescent sensors. Barium chemosensors can be important for measuring soluble Ba 2+ in drinking water and have gained recent attention for their potential to enhance the detection of rare events in xenon decay. Here we quantify the capability of three chemosensors, marketed for biologically useful K + sensing, as effective probes for Ba 2+ ions. Here, we present measurements from bulk spectrofluorometry to characterize the system in aqueous solutions and demonstrate the usefulness of these species for low-background single-ion fluorescence microscopy, revealing new candidates for Ba 2+ sensing.

Miller, R. L. [Department of Chemistry and Biochem↗