Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Towards Arbitrary Accuracy Inviscid Surface Boundary Conditions

Inviscid nonlinear surface boundary conditions are currently limited to third order accuracy in time for non-moving surfaces and actually reduce to first order in time when the surfaces move. For steady-state calculations it may be possible to achieve higher accuracy in space, but high accuracy in time is required for efficient simulation of multiscale unsteady phenomena. A surprisingly simple technique is shown here that can be used to correct the normal pressure derivatives of the flow at a surface on a Cartesian grid so that arbitrarily high order time accuracy is achieved in idealized cases. This work demonstrates that nonlinear high order time accuracy at a solid surface is possible and desirable, but it also shows that the current practice of only correcting the pressure is inadequate.

Dyson, Rodger W.↗

A Method for Assessing the Accuracy of a Photogrammetry System for Precision Deployable Structures

The measurement techniques used to validate analytical models of large deployable structures are an integral Part of the technology development process and must be precise and accurate. Photogrammetry and videogrammetry are viable, accurate, and unobtrusive methods for measuring such large Structures. Photogrammetry uses Software to determine the three-dimensional position of a target using camera images. Videogrammetry is based on the same principle, except a series of timed images are analyzed. This work addresses the accuracy of a digital photogrammetry system used for measurement of large, deployable space structures at JPL. First, photogrammetry tests are performed on a precision space truss test article, and the images are processed using Photomodeler software. The accuracy of the Photomodeler results is determined through, comparison with measurements of the test article taken by an external testing group using the VSTARS photogrammetry system. These two measurements are then compared with Australis photogrammetry software that simulates a measurement test to predict its accuracy. The software is then used to study how particular factors, such as camera resolution and placement, affect the system accuracy to help design the setup for the videogrammetry system that will offer the highest level of accuracy for measurement of deploying structures.

Moore, Ashley↗

Estimated Accuracy of Three Common Trajectory Statistical Methods

Three well-known trajectory statistical methods (TSMs), namely concentration field (CF), concentration weighted trajectory (CWT), and potential source contribution function (PSCF) methods were tested using known sources and artificially generated data sets to determine the ability of TSMs to reproduce spatial distribution of the sources. In the works by other authors, the accuracy of the trajectory statistical methods was estimated for particular species and at specified receptor locations. We have obtained a more general statistical estimation of the accuracy of source reconstruction and have found optimum conditions to reconstruct source distributions of atmospheric trace substances. Only virtual pollutants of the primary type were considered. In real world experiments, TSMs are intended for application to a priori unknown sources. Therefore, the accuracy of TSMs has to be tested with all possible spatial distributions of sources. An ensemble of geographical distributions of virtual sources was generated. Spearman s rank order correlation coefficient between spatial distributions of the known virtual and the reconstructed sources was taken to be a quantitative measure of the accuracy. Statistical estimates of the mean correlation coefficient and a range of the most probable values of correlation coefficients were obtained. All the TSMs that were considered here showed similar close results. The maximum of the ratio of the mean correlation to the width of the correlation interval containing the most probable correlation values determines the optimum conditions for reconstruction. An optimal geographical domain roughly coincides with the area supplying most of the substance to the receptor. The optimal domain s size is dependent on the substance decay time. Under optimum reconstruction conditions, the mean correlation coefficients can reach 0.70 0.75. The boundaries of the interval with the most probable correlation values are 0.6 0.9 for the decay time of 240 h and 0.5 0.95 for the decay time of 12 h. The best results of source reconstruction can be expected for the trace substances with a decay time on the order of several days. Although the methods considered in this paper do not guarantee high accuracy they are computationally simple and fast. Using the TSMs in optimum conditions and taking into account the range of uncertainties, one can obtain a first hint on potential source areas.

Kabashnikov, Vitaliy P.↗

Achieving Climate Change Absolute Accuracy in Orbit

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

Wielicki, Bruce A.↗

Lunar Reconnaissance Orbiter Orbit Determination Accuracy Analysis

Results from operational OD produced by the NASA Goddard Flight Dynamics Facility for the LRO nominal and extended mission are presented. During the LRO nominal mission, when LRO flew in a low circular orbit, orbit determination requirements were met nearly 100% of the time. When the extended mission began, LRO returned to a more elliptical frozen orbit where gravity and other modeling errors caused numerous violations of mission accuracy requirements. Prediction accuracy is particularly challenged during periods when LRO is in full-Sun. A series of improvements to LRO orbit determination are presented, including implementation of new lunar gravity models, improved spacecraft solar radiation pressure modeling using a dynamic multi-plate area model, a shorter orbit determination arc length, and a constrained plane method for estimation. The analysis presented in this paper shows that updated lunar gravity models improved accuracy in the frozen orbit, and a multiplate dynamic area model improves prediction accuracy during full-Sun orbit periods. Implementation of a 36-hour tracking data arc and plane constraints during edge-on orbit geometry also provide benefits. A comparison of the operational solutions to precision orbit determination solutions shows agreement on a 100- to 250-meter level in definitive accuracy.

Gravitation↗

Assessing and Ensuring GOES-R Magnetometer Accuracy

The GOES-R magnetometer accuracy requirement is 1.7 nanoteslas (nT). During quiet times (100 nT), accuracy is defined as absolute mean plus 3 sigma. During storms (300 nT), accuracy is defined as absolute mean plus 2 sigma. To achieve this, the sensor itself has better than 1 nT accuracy. Because zero offset and scale factor drift over time, it is also necessary to perform annual calibration maneuvers. To predict performance, we used covariance analysis and attempted to corroborate it with simulations. Although not perfect, the two generally agree and show the expected behaviors. With the annual calibration regimen, these predictions suggest that the magnetometers will meet their accuracy requirements.

Magnetometer↗

Assessing and Ensuring GOES-R Magnetometer Accuracy

The GOES-R magnetometer subsystem accuracy requirement is 1.7 nanoteslas (nT). During quiet times (100 nT), accuracy is defined as absolute mean plus 3 sigma. During storms (300 nT), accuracy is defined as absolute mean plus 2 sigma. Error comes both from outside the magnetometers, e.g. spacecraft fields and misalignments, as well as inside, e.g. zero offset and scale factor errors. Because zero offset and scale factor drift over time, it will be necessary to perform annual calibration maneuvers. To predict performance before launch, we have used Monte Carlo simulations and covariance analysis. Both behave as expected, and their accuracy predictions agree within 30%. With the proposed calibration regimen, both suggest that the GOES-R magnetometer subsystem will meet its accuracy requirements.

Magnetometer↗

Cause and Cure - Deterioration in Accuracy of CFD Simulations With Use of High-Aspect-Ratio Triangular Tetrahedral Grids

Traditionally high-aspect ratio triangular/tetrahedral meshes are avoided by CFD re-searchers in the vicinity of a solid wall, as it is known to reduce the accuracy of gradient computations in those regions and also cause numerical instability. Although for certain complex geometries, the use of high-aspect ratio triangular/tetrahedral elements in the vicinity of a solid wall can be replaced by quadrilateral/prismatic elements, ability to use triangular/tetrahedral elements in such regions without any degradation in accuracy can be beneficial from a mesh generation point of view. The benefits also carry over to numerical frameworks such as the space-time conservation element and solution element (CESE), where triangular/tetrahedral elements are the mandatory building blocks. With the requirement of the CESE method in mind, a rigorous mathematical framework that clearly identities the reason behind the difficulties in use of such high-aspect ratio triangular/tetrahedral elements is presented here. As will be shown, it turns out that the degree of accuracy deterioration of gradient computation involving a triangular element is hinged on the value of its shape factor Gamma def = sq sin Alpha1 + sq sin Alpha2 + sq sin Alpha3, where Alpha1; Alpha2 and Alpha3 are the internal angles of the element. In fact, it is shown that the degree of accuracy deterioration increases monotonically as the value of Gamma decreases monotonically from its maximal value 9/4 (attained by an equilateral triangle only) to a value much less than 1 (associated with a highly obtuse triangle). By taking advantage of the fact that a high-aspect ratio triangle is not necessarily highly obtuse, and in fact it can have a shape factor whose value is close to the maximal value 9/4, a potential solution to avoid accuracy deterioration of gradient computation associated with a high-aspect ratio triangular grid is given. Also a brief discussion on the extension of the current mathematical framework to the tetrahedral-grid case along with some of the practical results of this extension is also provided. Furthermore, through the use of numerical simulations of practical viscous problems involving high-Reynolds number flows, the effectiveness of the gradient evaluation procedures within the CESE framework (that have their basis on the analysis presented here) to produce accurate and stable results on such high-aspect ratio meshes is also showcased.

CESE Method↗

Accuracy of Center of Pressure Determination via Motion Capture

BACKGROUND: This study was conducted to support the stability assessment for tasks in lunar gravity and exercises on a Vibration Isolation and Stabilization (VIS) system in microgravity based on the dynamic feasibility criterion of whether the calculated position of the center of pressure (COP) falls within the base of support (BOS) which outlines the subject’s feet. Motion capture data combined with biomechanical modeling and simulation allows the forces and moments between the human and the VIS platform to be computed and the position of the COP as well as the location and shape of the BOS to be determined. The goal of this study was to assess the accuracy of the COP trajectory calculated using motion capture-based data. METHODS AND RESULTS: To obtain the dynamic quantities from which COP is calculated, motion capture data is first collected in the 1g lab environment by recording the trajectories of passive retroreflective markers placed on a subject during exercise or performance of a given task. The OpenSim [1] inverse kinematics (IK) tool is used to fit a scaled subject model to recorded marker trajectories while minimizing marker error to obtain joint angles. Then, a custom OpenSim plugin [2] is used to determine the subject’s time-varying moment of inertia and its time derivative, center of mass (CM) position, velocity, and acceleration, as well as the angular momentum and its time derivative relative to the subject’s CM. Some of these quantities are not needed for modeling tasks performed on a stationary lunar surface but, due to the moving exercise platform, are needed to model VIS response to the subject’s motion. Hand positions, used in calculating a cable force if present, are recorded as well. These quantities are used to calculate the total force (F ⃗^((plate) )) and moment (M ⃗^((plate) )) exerted by the lunar surface or the VIS plate on the subject’s shoe soles. COP is then calculated from the following equations: r_x^((cop) )= M_z^((plate) )/F_y^((plate) ) and r_z^((cop) )= 〖-M〗_x^((plate) )/F_y^((plate) ), where the y axis is normal to the surface. COP accuracy for feasibility assessments is then determined by whether it falls within the BOS, which is also computed by the plugin. To study the accuracy of COP calculated from motion capture, we first investigated whether COP remained within the BOS, as it must, for exercises performed in the 1g lab environment. Standard exercises such as back squat and deadlift were analyzed, as well as more explosive exercises including hang clean and press. Cases in which the COP exited the BOS indicated that COP accuracy required further investigation. In this study, an exercise device with cables was used, so cable force modeling accuracy should also be considered. In a separate study, we collected motion capture and force plate data for twenty-seven motions not involving an exercise device. About a third were genuine countermeasures exercises (e.g., hang clean and press), some were relevant for lunar tasks (e.g., object pick up), and the rest were of a “unit test” nature (e.g., swaying back and forth or side to side). Motion capture-based COP positions were compared with force plate measured COP. We found that while force plate measured COP remained within the BOS, motion capture-based COP was observed to briefly exit the BOS on occasion. Techniques to mitigate IK artifacts and filtering of calculated data could be used to improve the agreement of calculated and measured results, resolving excursions from the BOS within this dataset. The mean error between calculated and measured COP was found to be less than 6 mm. Additionally, we derived and investigated equations for the COP in terms of the cable force, cable location, as well as the human CM position, acceleration, and angular momentum with respect to the CM, and analyzed them for sensitivity to errors in individual quantities. Several were found, but the most significant one was that when the vertical force on the feet approaches zero, indicating a near-detachment or ‘jump off’ condition, errors are amplified. This is consistent with the observation that in the absence of pressure, the concept of the center of pressure would become meaningless.

C A Bell↗

Investigating Photogrammetric Accuracy of a Lunar-lander-induced Crater Measurement System

Laboratory measurements have been made to validate the performance of the Stereo CAmeras for Lunar Plume-Surface Studies (SCALPSS) stereo photogrammetry systems which will be flying to the moon on two of NASA’s upcoming Commercial Lunar Payload Services (CLPS) missions. Until recently, the system’s accuracy had only been studied using idealized geometric shapes as measurement targets. A realistic crater model of representative scale and an idealized ‘staircase’ target have been used to compare measurement accuracy of ideal versus lunar-like objects, with the commercial V-STARS® system being used to provide the known reference values for comparison. In a parametric study, altitude, lens focal length, and camera separation are varied to assess each parameter’s impact on photogrammetric accuracy in relation to the scaling law prediction developed previously. The SCALPSS 1.0 and 1.1 configurations have been validated on the crater model within acceptable accuracy for the missions, performing significantly better than the scaling law prediction in some cases. A semi-automated post-processing routine was developed in MATLAB® and proved successful for the cross-correlation of features between two stereo images. For some cases of extreme convergence angles between a camera pair, manual feature detection and matching was required. By using this manual process, the crater depth map was reconstructed but with worse accuracy than the idealized staircase measurements; refinements to the processing algorithm are expected to improve future results. Also examined in this work is the impact of illumination environments, both natural (e.g., Sun angles) and artificial (diffuse or structured illumination sources), on the camera system’s ability to measure the erosion of the lunar terrain.

Plume-surface interaction↗

Investigating Photogrammetric Accuracy of a Lunar-lander-induced Crater Measurement System

Laboratory measurements have been made to validate the performance of the Stereo CAmeras for Lunar Plume-Surface Studies (SCALPSS) stereo photogrammetry systems which will be flying to the moon on two of NASA’s upcoming Commercial Lunar Payload Services (CLPS) missions. Until recently, the system’s accuracy had only been studied using idealized geometric shapes as measurement targets. A realistic crater model of representative scale and an idealized ‘staircase’ target have been used to compare measurement accuracy of ideal versus lunar-like objects, with the commercial V-STARS® system being used to provide the known reference values for comparison. In a parametric study, altitude, lens focal length, and camera separation are varied to assess each parameter’s impact on photogrammetric accuracy in relation to the scaling law prediction developed previously. The SCALPSS 1.0 and 1.1 configurations have been validated on the crater model within acceptable accuracy for the missions, performing significantly better than the scaling law prediction in some cases. A semi-automated post-processing routine was developed in MATLAB® and proved successful for the cross-correlation of features between two stereo images. For some cases of extreme convergence angles between a camera pair, manual feature detection and matching was required. By using this manual process, the crater depth map was reconstructed but with worse accuracy than the idealized staircase measurements; refinements to the processing algorithm are expected to improve future results. Also examined in this work is the impact of illumination environments, both natural (e.g., Sun angles) and artificial (diffuse or structured illumination sources), on the camera system’s ability to measure the erosion of the lunar terrain.

Plume-surface interaction↗

Comparative Accuracies of Models for Drag Prediction During Geomagnetically Disturbed Periods: A First Principles Model Versus Empirical Models

We examine the accuracy of density prediction by the first principles model Thermosphere Ionosphere Electrodynamics General Circulation Model (TIEGCM) developed by the National Center for Atmospheric Research and compare it to the accuracy of three empirical models: Jacchia 71, the Naval Research Laboratory Mass Spectrometer Incoherent Scatter Extended 2000 (NRLMSIS), Jacchia 1971, and Jacchia-Bowman 2008. Comparisons are made for three large storms: the October 2003 storm, the March 2013 storm, and the March 2015 storm. To evaluate the accuracy of these models we use tracking data for nine space objects in low Earth orbit. Additionally, we evaluate the accuracy of the TIEGCM and NRLMSIS with data from high precision accelerometers on the Challenging Minisatellite Payload (CHAMP) and Gravity field and Circulation Explorer (GOCE) satellites. The goal is to assess the use of a first principles model as a potential tool for forecasting satellite drag during large magnetic storms. For the storms considered, we found the TIEGCM, JB2008, and NRLMSIS models to be substantially more accurate than the Jacchia 71 model. The accuracies of the TIEGCM and JB2008 models were similar, but overall, the TIEGCM was more accurate. We found smaller differences for TIEGCM versus CHAMP than for NRLMIS for the Halloween Storm, and smaller differences than results published for JB2008 and the assimilative model HASDM. The empirical models are at present more practical for operational purposes, but the TIEGCM, developed as a research model, with a greater focus on operational use offers the potential for improved utility during stressing conditions.

R. L. Walterscheid↗

Methodology to Define Delivery Accuracy Under Current Day ATC Operations

In order to enable arrival management concepts and solutions in a NextGen environment, ground- based sequencing and scheduling functions have been developed to support metering operations in the National Airspace System. These sequencing and scheduling algorithms as well as tools are designed to aid air traffic controllers in developing an overall arrival strategy. The ground systems being developed will support the management of aircraft to their Scheduled Times of Arrival (STAs) at flow-constrained meter points. This paper presents a methodology for determining the undelayed delivery accuracy for current day air traffic control operations. This new method analyzes the undelayed delivery accuracy at meter points in order to understand changes of desired flow rates as well as enabling definition of metrics that will allow near-future ground automation tools to successfully achieve desired separation at the meter points. This enables aircraft to meet their STAs while performing high precision arrivals. The research presents a possible implementation that would allow delivery performance of current tools to be estimated and delivery accuracy requirements for future tools to be defined, which allows analysis of Estimated Time of Arrival (ETA) accuracy for Time-Based Flow Management (TBFM) and the FAA's Traffic Management Advisor (TMA). TMA is a deployed system that generates scheduled time-of-arrival constraints for en- route air traffic controllers in the US. This new method of automated analysis provides a repeatable evaluation of the delay metrics for current day traffic, new releases of TMA, implementation of different tools, and across different airspace environments. This method utilizes a wide set of data from the Operational TMA-TBFM Repository (OTTR) system, which processes raw data collected by the FAA from operational TMA systems at all ARTCCs in the nation. The OTTR system generates daily reports concerning ATC status, intent and actions. Due to its availability, ease of use, and vast collection of data across several airspaces it was determined that the OTTR data set would be the best method to utilize moving forward with this analysis. The particular variables needed for further analysis were determined along with the necessary OTTR reports, by working closely with the repository team additional analysis reports were developed that provided key ETA and STA information at the freeze horizon. One major benefit of the OTTR data is that using the correct reports the data across several airports could be analyzed over large periods of time. The OTTR data processes the TBFM data daily and is stored in various formats across several airspaces. This allowed us to develop our own parsing methods and raw data processing that would not rely on other computationally expensive tools that perform more in depth analysis of similar sets of data. The majority of this work consisted of the development of the ability to filter flights to create a subset of flights that could be considered undelayed, which is defined as a flight at the freeze horizon with an ETA and STA difference that was minimal or close to zero. This was a broad method that allowed the consideration of a large data set which consisted of all the traffic across a two month period in 2013, the hottest and coldest months, arriving into four airports: George Bush Intercontinental, Denver International, Los Angeles International, and Phoenix Sky Harbor.

delivery accuracy↗

STRAP IV - High accuracy, low drift attitude control system.

The STRAP IV attitude control system was designed, tested, and successfully launched to provide stable high accuracy pointing at nontrackable X-ray sources. On its initial flight (May 19, 1972), the STRAP IV control system updated its high accuracy, rate integrating gyros on two successive stellar targets and then maneuvered the rocket body to point the experimental payload at two separate X-ray sources and an X-ray-free background location. The third axis, which remained under the control of a coarse free gyro, was updated by a technique of successive star-target coordinate transformation to ensure the correct fine-axis azimuth alignment for the high accuracy inertial maneuvers. Pointing accuracies of 4 arc min with limit cycle stability of less than 20 arc sec peak to peak were obtained on all targets.

Shrewsberry, D. J.↗

The accuracy of far-field noise obtained by the mathematical extrapolation of near-field noise data

Results are described of an analytical study of the accuracy and limitations of a technique that permits the mathematical extrapolation of near-field noise data to far-field conditions. The effects of the following variables on predictive accuracy of the far-field pressure were examined: (1) number of near-field microphones; (2) length of source distribution; (3) complexity of near-field and far-field distributions; (4) source-to-microphone distance; and (5) uncertainties in microphone data and imprecision in the location of the near-field microphones. It is shown that the most important parameters describing predictive accuracy are the number of microphones, the ratio of source length to acoustic wavelength, (L/wavelength), and the error in location of near-field microphones. If microphone measurement and location errors are not included, then far-field pressures can be accurately predicted up to L/wavelength values of 15 using approximately 50 microphones. For maximum microphone location errors of + or - 1 cm, only an accuracy of + or - 2-1/2 db can be attained with approximately 40 microphones for the highest L/wavelength of 10.

Ahtye, W. F.↗

A study of orbit determination accuracies for future earth observatory missions

It is anticipated that global orbital accuracies of 10 meters will be required for future earth observatory missions. Results are presented of a study of the LANDSAT-1 orbit to determine position accuracies obtainable today so as to assess what future advancements are necessary to meet a 10-meter goal. Accuracies of 50 meters were determined to be achievable now from two-day tracking arcs. One-half-day arcs yield accuracies of about 30 meters. The dominant error source was found to be geopotential model uncertainty. All other systematic errors produced less than 10 meters total position error.

Bryant, W. C., Jr.↗

The accuracy of far-field noise obtained by the mathematical extrapolation of near-field noise data

Results are presented for an analytical study of the accuracy and limitations of a technique that permits the mathematical extrapolation of near-field noise data to far-field conditions. The effects of the following variables on predictive accuracy of the far-field pressure were examined: (1) number of near-field microphones; (2) length of source distribution; (3) complexity of near-field and far-field distributions; (4) source-to-microphone distance; and (5) uncertainties in microphone data and imprecision in the location of the near-field microphones. It is shown that the most important parameters describing predictive accuracy are the number of microphones, the ratio of source length to acoustic wavelength (L/lambda), and the error in location of near-field microphones. For maximum microphone location errors of plus or minus 1 cm, only an accuracy of plus or minus 2.5 dB can be attained with approximately 40 microphones for the highest L/lambda of 10.

Ahtye, W. F.↗

Future timing accuracy requirements and procedures for data processing

Timing accuracy requirements for satellite experiment data are discussed. Although time accuracies of 100 milliseconds were sufficient when OSO-3, 4, 5 were launched in the mid-60s, time accuracies of 100 microseconds are necessary for OSO-8, HEAO-A, and Seasat, and it is thought likely that accuracies of 10 microseconds will become routine in the 1980s. An approach to the problem of identifying the sources of spacecraft timing errors - from the onboard counters to the final tagging of data - is considered.

Smith, G. A.↗