Abstract
The GOES-R magnetometer accuracy requirement is 1.7 nanoteslas (nT). During quiet times (100 nT), accuracy is defined as absolute mean plus 3 sigma. During storms (300 nT), accuracy is defined as absolute mean plus 2 sigma. To achieve this, the sensor itself has better than 1 nT accuracy. Because zero offset and scale factor drift over time, it is also necessary to perform annual calibration maneuvers. To predict performance, we used covariance analysis and attempted to corroborate it with simulations. Although not perfect, the two generally agree and show the expected behaviors. With the annual calibration regimen, these predictions suggest that the magnetometers will meet their accuracy requirements.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Kronenwetter, Jeffrey, Carter, Delano R., Todirita, Monica, Chu, Donald. 2016-04-04. Assessing and Ensuring GOES-R Magnetometer Accuracy. https://ntrs.nasa.gov/citations/20160004689