Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANTIGENS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Piezoelectric cantilever sensors

A piezoelectric cantilever with a non-piezoelectric, or piezoelectric tip useful as mass and viscosity sensors. The change in the cantilever mass can be accurately quantified by monitoring a resonance frequency shift of the cantilever. For bio-detection, antibodies or other specific receptors of target antigens may be immobilized on the cantilever surface, preferably on the non-piezoelectric tip. For chemical detection, high surface-area selective absorbent materials are coated on the cantilever tip. Binding of the target antigens or analytes to the cantilever surface increases the cantilever mass. Detection of target antigens or analytes is achieved by monitoring the cantilever's resonance frequency and determining the resonance frequency shift that is due to the mass of the adsorbed target antigens on the cantilever surface. The use of a piezoelectric unimorph cantilever allows both electrical actuation and electrical sensing. Incorporating a non-piezoelectric tip (14) enhances the sensitivity of the sensor. In addition, the piezoelectric cantilever can withstand damping in highly viscous liquids and can be used as a viscosity sensor in wide viscosity range.

Shih, Wan Y.↗

MEMS reagent and sample handling procedure: Feasibility of viral antibody detection by passive immune agglutination

An attempt was made to develop a test requiring no preadsorption steps for the assessment of antibodies to rubella and mumps viruses using the passive immune agglutination (PIA) method. Both rubella and mumps antigens and antibodies were prepared. Direct PIA tests, using rubella antigen-coated beads, and indirect PIA tests, using rubella antibody-coated beads, were investigated. Attempts, using either method, were unsuccessful. Serum interference along with nonspecific agglutination of beads by the rubella antigen resulted in no specific response under the test conditions investigated. A new, highly sensitive approach, the enzyme immunoassay (EIA) test system, is recommended to overcome the nonspecificity. This system is a logical outgrowth of some of the solid phase work done on MEMS and represents the next generation tests system that can be directly applied to early disease detection and monitoring.

Bailey, G. D.↗

Quality control of murine monoclonal antibodies using isoelectric focusing affinity immunoblot analysis

The quality control of murine hybridoma secretory products has been performed using two approaches for isoelectric focusing affinity immunoblot analysis: (1) a method in which antigen-coated nitrocellulose is placed on top of an acrylamide gel containing isoelectrically focused ascites to bind the antigen specific monoclonal antibody; and (2) a method in which focused ascite proteins were passively blotted onto nitrocellulose and specific monoclonal antibodies were detected with enzyme-conjugated antigen. Analysis by both methods of batches of ascites containing antihuman IgG antibodies that were produced by six hybridomas permitted effective monitoring of immunoreactive antibodies for pI microheterogeneity.

Hamilton, Robert G.↗

Effects of spaceflight on levels and activity of immune cells

Experiments were carried out on cells from rats that had been flown on Soviet Biosputnik Cosmos 1887 to explore the effects of speceflight on immune responses. Rat bone marrow cells were examined for their response to colony stimulating factor-M. Rat spleen and bone marrow cells were stained with antibodies directed against cell surface antigenic markers. The results of the studies indicate that bone marrow cells from flown rats showed a decreased response to colony stimulating factor. There was a higher percentage of spleen cells from flown rats staining positively for pan-T-cell, suppressor-T-cell, and interleukin-2 receptor cell surface antigens. A small increase in the percentage of cells staining positively for helper-T-cell antigens was also noted. In addition, a higher percentage of cells that appeared to be part of the myelogenous population of bone marrow cells from flown rats stained positively for surface immunoglobulin.

Sonnenfeld, Gerald↗

Determination of the Absolute Number of Cytokine mRNA Molecules within Individual Activated Human T Cells

A primary function of activated T cells is the expression and subsequent secretion of cytokines, which orchestrate the differentiation of other lymphocytes, modulate antigen presenting cell activity, and alter vascular endothelium to mediate an immune response. Since many features of immune regulation probably result from modest alterations of endogenous rates of multiple interacting processes, quantitative analysis of the frequency and specific activity of individual T cells is critically important. Using a coordinated set of quantitative methods, the absolute number of molecules of several key cytokine mRNA species in individual T cells has been determined. The frequency of human blood T cells activated in vitro by mitogens and recall protein antigens was determined by intracellular cytokine protein staining, in situ hybridization for cytokine mRNA, and by limiting dilution analysis for cytokine mRNA+ cells. The absolute number of mRNA molecules was simultaneously determined in both homogenates of the entire population of cells and in individual cells obtained by limiting dilution, using a quantitative, competitive RT-PCR assay. The absolute numbers of mRNA molecules in a population of cells divided by the frequency of individual positive cells, yielded essentially the same number of mRNA molecules per cell as direct analysis of individual cells by limiting dilution analysis. Mean numbers of mRNA per positive cell from both mitogen and antigen activated T cells, using these stimulation conditions, were 6000 for IL-2, 6300 for IFN-gamma, and 1600 for IL-4.

Karr, Laurel J.↗

Human Peripheral Blood Mononuclear Cells Cultured in Normal and Hyperglycemic Media in Simulated Microgravity Using NASA Bioreactors

We sought answers to several questions this summer at NASA Johnson Space Center. Initial studies involved the in vitro culture of human peripheral blood mononuclear in cells in different conditioned culture media. Several human cancer clones were similarly studied to determine responses to aberrant glycosylation by the argon laser. The cells were grown at unit gravity in flasks and in simulated microgravity using NASA bioreactors. The cells in each instance were analyzed by flow cytometry. Cell cycle analysis was acquired by staining nuclear DNA with propidium iodide. Responses to the laser stimulation was measured by observing autofluorescence emitted in the green and red spectra after stimulation. Extent of glycosylation correlated with the intensity of the laser stimulated auto-fluorescence. Our particular study was to detect and monitor aberrant glycosylation and its role in etiopathogenesis. Comparisons were made between cells known to be neoplastic and normal cell controls using the same Laser Induced Autofluorescence technique. Studies were begun after extensive literature searches on using the antigen presenting potential of dendritic cells to induce proliferation of antigen specific cytotoxic T-cells. The Sendai virus served as the antigen. Our goal is to generate sufficient numbers of such cells in the simulated microgravity environment for use in autologous transplants of virally infected individuals including those positive for hepatitis and HIV.

Lawless, DeSales↗

Demonstration of four immunoassay formats using the array biosensor

The ability of a fluorescence-based array biosensor to measure and quantify the binding of an antigen to an immobilized antibody has been demonstrated using the four different immunoassay formats: direct, competitive, displacement, and sandwich. A patterned array of antibodies specific for 2,4,6-trinitrotoluene (TNT) immobilized onto the surface of a planar waveguide and used to measure signals from different antigen concentrations simultaneously. For direct, competitive, and displacement assays, which are one-step assays, measurements were obtained in real time. Dose-response curves were calculated for all four assay formats, demonstrating the array biosensor's ability to quantify the amount of antigen present in solution.

NASA Discipline Life Sciences Technologies↗

Persistent Seroconversion after Accidental Eye Exposure to Calcifying Nanoparticles

Biosafety of nanomaterials has attracted much attention recently. We report here a case where accidental human eye exposure to biogenic nanosized calcium phosphate in the form of calcifying nanoparticles (CNP) raised a strong IgG immune response against proteins carried by CNP. The antibody titer has persisted over ten years at the high level. The IgG was detected by ELISA using CNPs propagated in media containing bovine and human serum as antigen. The exposure incident occurred to a woman scientist (WS) at a research laboratory in Finland at 1993. CNP, also termed "nanobacteria", is a unique self-replicating agent that has not been fully characterized and no data on biohazards were available at that time. Before the accident, her serum samples were negative for both CNP antigen and anti-CNP antibody using specific ELISA tests (Nanobac Oy, Kuopio, Finland). The accident occurred while WS was harvesting CNP cultures. Due to a high pressure in pipetting, CNP pellet splashed into her right eye. Both eyes were immediately washed with water and saline. The following days there was irritation and redness in the right eye. These symptoms disappeared within two weeks without any treatment. Three months after the accident, blood and urine samples of WS were tested for CNP cultures (2), CNP-specific ELISA tests, and blood cell counts. Blood cell counts were normal, CNP antigen and culture tests were negative. A high IgG anti-CNP antibody titer was detected (see Figure). The antibodies of this person have been used thereafter as positive control and standard in ELISA manufacturing (Nano-Sero IgG ELISA, Nanobac Oy, Kuopio, Finland).

Ciftcioglu, Neva↗

A Preliminary Analysis of Calcifying Particles in the Serum and Prostates of Patients with Prostatic Inflammation

Chronic diseases of the prostate such as benign prostatic hyperplasia (BPH) & chronic pelvic pain syndrome (CPPS) have associated findings of chronic inflammation, despite a lack of causal relationship. Numerous attempts to define an infectious agent responsible for the clinical findings have been inconsistent. The possibility of an infectious agent, that has not been uncovered with routine culturing methods, forms the basis for this study. Serum from 940 healthy Finnish men were compared with serum from 40 Crohn's, 40 path dx prostatitis, & 40 with path dx carcinoma, using an enzyme-linked immunosorbant assay (ELISA), to detect antigens specific to Nanobacteria(NB) utilizing monoclonal antibodies (Ab) 5/3 and 8D10. This ELISA has not been validated for detecting NB-associated with clinical prostatic disease, yet cross-reactivity with other bacterial species is low. Immunohistochemistry was performed on de-paraffinized prostatic tissue slides, de-calcified with EDTA and stained with the DAKO Catalyzed Signal Amplification kit, employing 8D10 as the primary (target/antigen-detecting) Ab. The mean (plus or minus SD) & median concentrations of NB antigen (U/50 L) were 379.59 (plus or minus 219.28) & 640.00 for patients with prostatitis (BPH) vs 3.31 (plus or minus 3.55) & 2.94 for prostate adenocarcinoma, 1.88 (plus or minus 2.94) & 0.80 for Crohn's disease, & 7.43 (plus or minus 25.57) & 0.00 for patients with no clinical prostatic disease. Unpaired t-tests revealed statistically significant differences between the prostatitis (BPH) sera & each of the other groups with p less than 0.005, but no differences between the other groups themselves. Preliminary studies with immunohistochemistry & 3-D confocal microscopy reveal 16/24 tissue sections + for NB Ag in BPH vs. only 2/22 tissue sections with prostate cancer. The preliminary findings of this serum screening study suggest that NB antigen may be commonly found in the serum of patients with the pathological diagnosis of prostatitis. Preliminary immunohistologic studies, suggest that NB may be found within the gland itself at a higher rate in patients with BPH relative to patients with adenocarcinoma, however confirmatory studies with a more specific ELISA technique, primary cultures, & with larger numbers of patients in a prospective design are required to determine if 1) NB are a causative organism for clinical hyperplastic and inflammatory disease, & if 2) serological testing can be used to discriminate patients with nanobacterial-associated prostatic disease.

Jones, Jeffrey A.↗

Gamma-ray mutagenesis studies in a new human-hamster hybrid, A(L)CD59(+/-), which has two human chromosomes 11 but is hemizygous for the CD59 gene

Kraemer, S. M., Vannais, D. B., Kronenberg, A., Ueno, A. and Waldren, C. A. Gamma-Ray Mutagenesis Studies in a New Human-Hamster Hybrid, A(L)CD59(+/-), which has Two Human Chromosomes 11 but is Hemizygous for the CD59 Gene. Radiat. Res. 156, 10-19 (2001).We have developed a human-CHO hybrid cell line, named A(L)CD59(+/-), which has two copies of human chromosome 11 but is hemizygous for the CD59 gene and the CD59 cell surface antigen that it encodes. Our previous studies used the A(L) and A(L)C hybrids that respectively contain one or two sets of CHO chromosomes plus a single copy of human chromosome 11. The CD59 gene at 11p13.5 and the CD59 antigen encoded by it are the principal markers used in our mutagenesis studies. The hybrid A(L)CD59(+/-) contains two copies of human chromosome 11, only one of which carries the CD59 gene. The incidence of CD59 (-) mutants (formerly called S1(-)) induced by (137)Cs gamma rays is about fivefold greater in A(L)CD59(+/-) cells than in A(L) cells. Evidence is presented that this increase in mutant yield is due to the increased induction of certain classes of large chromosomal mutations that are lethal to A(L) cells but are tolerated in the A(L)CD59(+/-) hybrid. In addition, significantly more of the CD59 (-) mutants induced by (137)Cs gamma rays in A(L)CD59(+/-) cells display chromosomal instability than in A(L) cells. On the other hand, the yield of gamma-ray-induced CD59 (-) mutants in A(L)CD59(+/-) cells is half that of the A(L)C hybrid, which also tolerates very large mutations but has only one copy of human chromosome 11. We interpret the difference in mutability as evidence that repair processes involving the homologous chromosomes 11 play a role in determining mutant yields. The A(L)CD59(+/-) hybrid provides a useful new tool for quantifying mutagenesis and shedding light on mechanisms of genetic instability and mutagenesis.

NASA Discipline Radiation Health↗

Antibody binding in altered gravity: implications for immunosorbent assay during space flight

A single antibody-incubation step of an indirect, enzyme-linked immunosorbent assay (ELISA) was performed during microgravity, Martian gravity (0.38 G) and hypergravity (1.8 G) phases of parabolic flight, onboard the NASA KC-135 aircraft. Antibody-antigen binding occurred within 15 seconds; the level of binding did not differ between microgravity, Martian gravity and 1 G (Earth's gravity) conditions. During hypergravity and 1 G, antibody binding was directly proportional to the fluid volume (per microtiter well) used for incubation; this pattern was not observed during microgravity. These effects in microgravity may be due to "fluid spread" within the chamber (observed during microgravity with digital photography), leading to greater fluid-surface contact and subsequently antibody-antigen contact. In summary, these results demonstrate that: i) ELISA antibody-incubation and washing steps can be successfully performed by human operators during microgravity, Martian gravity and hypergravity; ii) there is no significant difference in antibody binding between microgravity, Martian gravity and 1 G conditions; and iii) a smaller fluid volume/well (and therefore less antibody) was required for a given level of binding during microgravity. These conclusions indicate that reduced gravity would not present a barrier to successful operation of immunosorbent assays during spaceflight.

NASA Discipline Environmental Health↗

Anti-Ig autoantibody and complement-mediated destruction of neoplastic cells

Some immune response are effected through immunoglobulins (Ig), of which five classes have been recognized, namely, IgA, IgD, IgE, IgG, and IgM. Auto-antibodies associated with rheumatoid arthritis, termed rheumatoid factors (RF) react with antigenic determinants on IgG heavy chains. RF has predominant but not complete IgM specificity. This auto-antibody response was not detected in treated patients with primary brain tumors (where tissue is sequestered from the immune system by an intact bloodbrain barrier) or with multiple myeloma where humoral immunity is usually impaired. In addition, the prevalence of RF is not increased with solid tumors prior to initiation of chemotherapy or radiotherapy. It is proposed that RF is related to prior chemotherapy or radiotherapy of tumors anatomically accessible to immunologic tissues capable of antibody responses. A primary IgG response occurs, antigen-antibody complexes form, complexed IgG becomes immunologic, and an RF response results.

Towmey, J. J.↗

Functional colloidal particles for immunoresearch

The paper deals with the development of a new class of immunological reagents consisting of antibodies covalently bonded to polymeric microspheres to serve as convenient markers for detection of cell surface antigens by scanning electron and light microscopy. Attention is focused on the design and synthesis of spherical particles containing hydroxyl and carboxyl groups on their surface in a wide range of sizes (30-340 nm diam) by emulsion copolymerization, the preparation of spherical particles ranging from 300 nm to 3 microns and containing a variety of functional groups by means of ionizing radiation, and the experimental conditions for the covalent bonding of fluorescent molecules and antibodies to the spheres by means of the cyanogen bromide, carbodiimide and glutaraldehyde methods. These reagents are used to locate antigens on red blood cells, on mouse and human lymphocytes, and on the surface of photoreceptors. They offer a number of advantages and applications for the study of cell surfaces for immunodiagnosis.

Yen, S. P. S.↗

Effect of space flight on cell-mediated immunity

The cell-mediated immune response to Listeria monocytogenes was studied in rats subjected to 20 days of flight aboard the Soviet biosatellite Kosmos 7820. Groups of rats were immunized with 1,000,000 formalin-killed Listeria suspended in Freunds Complete Adjuvant, 5 days prior to flight. Immunized rats subjected to the same environmental factors as the flight rats, except flight itself, and immunized and nonimmunized rats held in a normal animal colony served as controls. Following recovery, lymphocyte cultures were harvested from spleens of all rats, cultured in vitro in the presence of L. monocytogenes antigens, Phytohemagglutinin, Conconavlin A, or purified protein derivative (PPD), and measured for their uptake of H-3-thymidine. Although individual rats varied considerably, all flight and immunized control rats gave a blastogenic response to the Listeria antigens and PPD. With several mitogens, the lymphocytes of flight rats showed a significantly increased blastogenic response over the controls. The results of this study do not support a hypothesis of a detrimental effect of space flight on cell-mediated immunity. The data suggest a possible suppressive effect of stress and gravity on an in vitro correlate of cell-mediated immunity.

Mandel, A. D.↗

The effects of hypergravity on the rate of antibody formation in the rat

This experiment was designed to measure the immune response in acutely stressed and chronically centrifuged hyper-G-adapted male rats. Rats were exposed to 2.1 and 3.1 G. Acutely stressed animals were injected with sheep red blood cells (SRBC) on the day of inital exposure to hyper-G, and were chronically centrifuged for 10 to 15 days after immunization. Hyper-G-adapted rats were chronically centrifuged for 28 days prior to antigen injection and for 21 days after injection. Booster injections were given and serum samples taken at intervals from 3 to 9 days after the initial and booster injections. Antigen dose, injected ip, ranged between 1.35 x 10 to the 6th and 1.38 x 10 to the 9th SRBC/100 g. body weight. Pair-fed and ad libitum fed noncentrifuged controls were used. No significant differences in anti-SRBC antibody titers were found between centrifuged and control animals, although there were some changes in WBC counts and a significant increase in adrenal-gland size in acutely stressed animals.

Scibetta, S. M.↗

Experiment K-6-23. Effect of spaceflight on levels and function of immune cells

Two different immunology experiments were performed on samples received from rats flown on Cosmos 1887. In the first experiment, rat bone marrow cells were examined in Moscow for their response to colony stimulating factor-M. In the second experiment, rat spleen and bone marrow cells were stained in Moscow with a variety of antibodies directed against cell surface antigenic markers. These cells were preserved and shipped to the United States where they were subjected to analysis on a flow cytometer. The results of the studies indicate that bone marrow cells from flown rats showed a decreased response to colony stimulating factor than did bone marrow cells from control rats. There was a higher percentage of spleen cells from flown rats staining positively for pan-T-cell, suppressor-T-cell and innate interleukin-2 receptor antigens than from control animals. In addition, a higher percentage of cells that appeared to be part of the myelogenous population of bone marrow cells from flown rats stained positively for surface immunoglobulin than did equivalent cells from control rats.

Mandel, A. D.↗

Production Of Human Antibodies

Process for making human monoclonal antibodies based on combination of techniques. Antibodies made active against specific antigen. Process involves in vivo immunization of human B lymphocyte cells in mice. B cells of interest enriched in vitro before fusion. Method potentially applicable to any antigen. Does not rely on use of Epstein-Barr virus at any step. Human lymphocytes taken from any source.

Sammons, David W.↗

In vivo testing confirms a blunting of the human cell-mediated immune mechanism during space flight

The cell-mediated immune (CMI) mechanism was evaluated in 10 space shuttle astronauts by measuring their delayed-type hypersensitivity response to seven common recall antigens. The Multitest CMI test system was used to administer antigens of tetanus, diphtheria, Streptococcus, Proteus, old tuberculin, Candida, and Trichophyton to the forearm 46 h before nominal mission termination; readings were conducted 2 h after landing. The mean number of reactions was reduced from 4.5 preflight to 3.0 inflight, and the mean reaction score was reduced from 21.4 to 13.7 mm inflight. The data presented suggest that the CMI system is still being degraded by space flight conditions on day 4 and that between day 5 and day 10, the depression maximizes and the system begins to adjust to the new conditions. The relation of these in vivo findings to previously reported in vitro results is discussed.

Taylor, G. R.↗