Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Composition And Electrical Properties Of Dust From Tokamak Compass

In spite of the fact that fusion is a subject of the study for many years, there are still a lot of open questions. One of the interesting topics in fusion research is a presence of dust grains in reactors. In the paper, dust grains born in tokamak Compass are studied and compared with samples of a spherical geometry and well known composition. A unique experimental setup was used for investigations of charging properties of such grains and the SEM and EDX spectroscopy was applied for a study of grain composition. We focus on the secondary emission because this process plays a prominent role when a portion of energetic electrons is present in surroundings of a particular grain. It was shown that depending on the grain size and material, energetic electrons charge the grains to positive potentials comparable with the energy of impinging electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual-source evaporation of silver bismuth iodide films for planar junction solar cells

Non-toxic and air-stable silver bismuth iodide semiconductors are promising light absorber candidates for photovoltaic applications owing to a suitable band gap for multi- or single-junction solar cells. Recently, solution-based film fabrication approaches for several silver bismuth iodide stoichiometries have been investigated. The current work reports on a facile and reproducible two-step coevaporation/annealing approach to deposit compact and pinhole-free films of AgBi 2 I 7 , AgBiI 4 and Ag 2 BiI 5 . X-ray diffraction (XRD) in combination with scanning electron microscopy (SEM)/energy-dispersive X-ray spectroscopy (EDX) analysis reveals formation of pure cubic (Fd$\bar{3}$m) with combining macron]m) phase AgBi 2 I 7 , cubic (Fd$\bar{3}$m) or rhombohedra (R$\bar{3}$m with combining macron]m) phase AgBiI 4 , each with >3 μm average grain size, or the rhombohedral phase (R$\bar{3}$m) Ag 2 BiI 5 with >200 nm average grain size. A phase transition from rhombohedral to cubic structure is investigated via temperature-dependent X-ray diffraction (TD-XRD). Planar-junction photovoltaic (PV) devices are prepared based on the coevaporated rhombohedral AgBiI 4 films, with titanium dioxide (TiO 2 ) and poly(3-hexylthiophene) (P3HT) as electron- and hole-transport layers, respectively. Finally, the best-performing device exhibited a power conversion efficiency (PCE) of as high as 0.9% with open-circuit voltage (VOC) > 0.8 V in the reverse scan direction (with significant hysteresis).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Directly Linking Low-Angle Grain Boundary Misorientation to Device Functionality for GaAs Grown on Flexible Metal Substrates

A new growth method to make highly oriented GaAs thin films on flexible metal substrates has been developed, enabling roll-to-roll manufacturing of flexible semiconductor devices. The grains are oriented in the <001> direction with <1 degree misorientations between them, and they have a comparable mobility to single-crystalline GaAs at high doping concentrations. At the moment, the role of low-angle grain boundaries (LAGBs) on device performance is unknown. A series of electron backscatter diffraction (EBSD) and cathodoluminesence (CL) studies reveal that increased doping concentrations decrease the grain size and increase the LAGB misorientation. Cross-sectional scanning transmission electron microscopy (STEM) reveals the complex dislocation structures within LAGBs. Most importantly, a correlative EBSD/electron beam-induced current (EBIC) experiment reveals that LAGBs are carrier recombination centers and that the magnitude of recombination is dependent on the degree of misorientation. The presented results directly link increased LAGB misorientation to degraded device performance, and therefore, strategies to reduce LAGB misorientations and densities would improve highly oriented semiconductor devices.

36 MATERIALS SCIENCE↗

Nanoimaging of Organic Charge Retention Effects: Implications for Nonvolatile Memory, Neuromorphic Computing, and High Dielectric Breakdown Devices

While a large variety of organic and molecular materials have been found to exhibit charge memory effects, the underlying mechanism is not well-understood, which hinders rational device design. Here, we study the charge retention mechanism of a nanoscale memory system, an organic monolayer on a silicon substrate, with Au nanoparticles on top serving as the electrical contact. Combining scanning probe imaging/manipulation and density functional simulations, we observe stable charge retention effects in the system and attributed it to polaron effects at the amine functional groups. Finally, our findings can pave the way for applications in nonvolatile memory, neuromorphic computing, and high dielectric breakdown devices.

36 MATERIALS SCIENCE↗

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗

Effect of Precursor Solution Aging on the Crystallinity and Photovoltaic Performance of Perovskite Solar Cells

Perovskite materials due to their exceptional photophysical properties are beginning to dominate the field of thin‐film optoelectronic devices. However, one of the primary challenges is the processing‐dependent variability in the properties, thus making it imperative to understand the origin of such variations. Here, it is discovered that the precursor solution aging time before it is cast into a thin film, is a subtle but a very important factor that dramatically affects the overall thin‐film formation and crystallinity and therein factors such as grain growth, phase purity, surface uniformity, trap state density, and overall solar cell performance. It is shown that progressive aging of the precursor promotes efficient formation of larger seeds after the fast nucleation of a large density of small seeds. The hot‐casting method then leads to the growth of large grains in uniform thin‐films with excellent crystallinity validated using scanning microscopy images and X‐ray diffraction patterns. The high‐quality films cast from aged solution is ideal for thin‐film photovoltaic device fabrication with reduced shunt current and good charge transport. This observation is a significant step toward achieving highly crystalline thin‐films with reliability in device performance and establishes the subtle but dramatic effect of solution aging before fabricating perovskite thin‐films.

Tsai, Hsinhan↗

Influence of Nitrogen on Hydrogenated Amorphous Carbon Thin Films Deposited by Plasma Focus Device

To carry out our research, a plasma focus device is used to deposit thin films of nitrogen doped hydrogenated amorphous carbon (a-C:H:N) onto the stainless steel-AISI-304 substrates at room temperature. Thin films are deposited with the same numbers of focus shots, at the same distance from the anode tip and with different partial pressures of nitrogen in the mixtures of acetylene/nitrogen as working gas. The nitrogen contents of deposited films are studied using nuclear reaction analysis (NRA) techniques. The results prove that nitrogen contents of the samples do not increase significantly by increasing partial pressure of nitrogen of the working gas for both sets of the samples. Moreover, NRA results exhibit the limitation of nitrogen incorporated into the samples, when this experimental setup is used. G-peak position and peak intensity ratio of the D-band to G-band (I{sub D}/I{sub G}) are used to investigate the diamond characters. Also, they show that sp{sup 2} clustering is highly dependent on the nitrogen atomic contents and angular position of the samples. Scanning electron microscopy (SEM) shows the granular surface morphology of the films. Furthermore, it shows that angular position of the samples with respect to the anode axis plays an important role in the grain size of the surface of the samples. The thickness of the films decreases significantly by increasing angular position of the samples, while it decreases slightly by increasing partial pressure of nitrogen of the working gas. The Vickers surface hardness of the thin films exhibits significant dependency on the sp{sup 2} clustering.

36 MATERIALS SCIENCE↗

Developing quantitative capabilities for a scanning microwave impedance microscope

Currently no instrument exists to quantitatively measure electrical properties (dielectric constant and conductivity) on sub-micron regions, a capability of extreme importance to measure the functioning of sub-micron structures and devices. In particular, such electrical measurements could support the development and manufacture of advanced energy related materials used in technologies such as photovoltaic cells, fuel cells and advanced batteries, thereby increasing performance and/or lowering production costs. The goal of this project is to develop microwave imaging add-on modules and probes capable of quantitatively measuring the electrical properties of small regions of a material using microwaves. These modules for scanning probe microscopes, such as atomic force microscopes, make use of the near-field interaction between the exciting microwaves and a material and can resolve regions 10 nanometers in size (less than a million atoms) with little perturbation of the material. In Phase 1 commercial probes and modified hardware were used to establish the feasibility of using microwave imaging systems to quantify local permittivity and conductivity. Repeatable measurements that vary in a systematic way with electrical parameters were obtained from a variety of samples. In Phase 2 research prototypes of the needed hardware and probes were developed and their performance against test structures and real-world samples was demonstrated. Result of this research project include demonstration of quantification of both permittivity and doping level at precisions up to 10% using multiple technical approaches. The level of performance and ease of use meets market expectations and the technology and protocols researched under this grant are currently being commercialized. Quantitative capabilities of this sort will provide a key capability to energy related technologies, and to a wide variety of semiconductor, biological, and materials science applications. Applications include both materials research in academic and industrial labs, as well as manufacturing applications. In a manufacturing environment the quantitative measurement and imaging capabilities could be used both as metrology for process control and as a tool for failure analysis and yield improvement.

36 MATERIALS SCIENCE↗

Magnetic microscopic imaging with an optically pumped magnetometer and flux guides

Here, by combining an optically pumped magnetometer (OPM) with flux guides (FGs) and by installing a sample platform on automated translation stages, we have implemented an ultra-sensitive FG-OPM scanning magnetic imaging system that is capable of detecting magnetic fields of ~20 pT with spatial resolution better than 300 μm (expected to reach ~10 pT sensitivity and ~100 μm spatial resolution with optimized FGs). As a demonstration of one possible application of the FG-OPM device, we conducted magnetic imaging of micron-size magnetic particles. Magnetic imaging of such particles, including nano-particles and clusters, is very important for many fields, especially for medical cancer diagnostics and biophysics applications. For rapid, precise magnetic imaging, we constructed an automatic scanning system, which holds and moves a target sample containing magnetic particles at a given stand-off distance from the FG tips. We show that the device was able to produce clear microscopic magnetic images of 10 μm-size magnetic particles. In addition, we also numerically investigated how the magnetic flux from a target sample at a given stand-off distance is transmitted to the OPM vapor cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Buried Interfaces in Organic Photocathodes for H 2 Evolution: Fermi-Level Pinning and Recombination

Herein, we demonstrate how Fermi-level pinning at buried contacts impacts solar fuel generation in all-polymer photocathodes by systematically comparing the effects of work function, hydroxyl coverage, and hydrogen evolution using chemically modified indium tin oxide (ITO) supports. Photovoltages and net photocathode performance are improved when the ITO is passivated using phosphonic acids, independent of work function, suggesting that the passivation reduces Fermi-level pinning at the buried interface arising from blended heterojunction interactions with surface metal hydroxyls. Transient photovoltage decay reveals differences in recombination mechanisms, supported by light intensity-dependent measurements. Briefly, nonpassivated, hydrophilic contacts exhibit trap-assisted recombination, while passivated, hydrophobic contacts follow bimolecular recombination. We then investigate changes in electroactivity of hole-transfer processes as a function of scan rate and repetitive cycling using a diffusion-controlled molecular redox probe, analogous to a hole-only device achieved via the electrolyte. The nonpassivated buried contacts exhibit higher overpotentials for oxidation, indicative of hole injection/extraction barriers. We observe irreversible electron transfer via the hole-transport level of the blended heterojunction and a strong cycle dependence, consistent with changes in the hole trap state density. Passivation results in more reversible redox behaviors, consistent with more Ohmic-like contacts. Collectively, these results provide context toward the realization of durable organic photoelectrodes with optimized photovoltages and net solar-to-hydrogen conversion efficiencies via fundamental understanding of the rates of carrier generation, recombination, and transport in high-dielectric aqueous environments and opportunities to characterize buried interfaces under device-relevant electric fields.

buried interfaces↗

Spatio-Kinetic Electronic Heterogeneity in MoS 2 Revealed by Ultrafast Electron Microscopy: Implications for Optoelectronics

There is broad interest in layered, two-dimensional (2D) semiconductors owing to their high optical absorption and ability to heterogeneously integrate with various substrates. In such layered semiconductors, mesoscopic imperfections, such as surface step edges, may affect charge carrier kinetics and device performance, but studying their effects on carrier transport with sufficient spatial and temporal resolution is a challenge. Using scanning ultrafast electron microscopy, we image the near-surface charge carrier kinetics with μm/ps spatiotemporal resolution in single-crystal MoS 2 samples with surface steps tens of nanometers in height. We find an approximately 3-fold increase in surface trap density near such surface steps compared to the uniform, flat surface regions. Despite the difference in trap state density, filling of the traps occurs over the same time scale (∼100 ps), but carrier recovery is much slower near the step compared to the uniform regions of the material. Furthermore, these results provide an approach to measure ultrafast dynamics and determine the required uniformity of layered materials depending on the speed limit constraints for specific applications.

SEM↗

High-resolution tunnelling spectroscopy of fractional quantum Hall states

Strong interactions between electrons in two-dimensional systems in the presence of a high magnetic field give rise to fractional quantum Hall states that host quasiparticles with a fractional charge and fractional exchange statistics. Here, in this work, we demonstrate high-resolution scanning tunnelling microscopy and spectroscopy of fractional quantum Hall states in ultra-clean Bernal-stacked bilayer graphene devices. Spectroscopy measurements show sharp excitations that have been predicted to emerge when electrons fractionalize into bound states of quasiparticles. We found energy gaps for candidate non-abelian fractional states that are larger by a factor of five than those in other related systems, for example, semiconductor heterostructures, and this suggests that bilayer graphene is an ideal platform for manipulating these quasiparticles and for creating topological quantum bits. We also found previously unobserved fractional states in our very clean graphene samples.

quantum Hall↗

Finite-difference time-domain methods

The finite-difference time-domain (FDTD) method is a widespread numerical tool for full-wave analysis of electromagnetic fields in complex media and for detailed geometries. Applications of the FDTD method cover a range of time and spatial scales, extending from subatomic to galactic lengths and from classical to quantum physics. Technology areas that benefit from the FDTD method include biomedicine — bioimaging, biophotonics, bioelectronics and biosensors; geophysics — remote sensing, communications, space weather hazards and geolocation; metamaterials — sub-wavelength focusing lenses, electromagnetic cloaks and continuously scanning leaky-wave antennas; optics — diffractive optical elements, photonic bandgap structures, photonic crystal waveguides and ring-resonator devices; plasmonics — plasmonic waveguides and antennas; and quantum applications — quantum devices and quantum radar. This Primer summarizes the main features of the FDTD method, along with key extensions that enable accurate solutions to be obtained for different research questions. Additionally, hardware considerations are discussed, plus examples of how to extract magnitude and phase data, Brillouin diagrams and scattering parameters from the output of an FDTD model. Furthermore, the Primer ends with a discussion of ongoing challenges and opportunities to further enhance the FDTD method for current and future applications.

42 ENGINEERING↗

Multimachine analysis of intermittent fluctuations in the scrape-off layer of magnetically confined fusion plasmas

Far scrape-off layer fluctuations, also known as blobs/filaments, are compared for the first time across six tokamaks: Alcator C-Mod, DIII-D, TCV, KSTAR, MAST, and MAST-U, under the context of stochastic modeling in Ohmic and low confinement mode scenarios. In this model, which well describes these fluctuations, measurements from Langmuir probes are modeled as a superposition of uncorrelated, two-sided exponential temporal pulses. The key parameters of this model are the mean waiting times between consecutive pulses, the pulse duration times and the mean of the pulse amplitudes. The study examines the influence of line-averaged density, plasma current, magnetic field and aspect ratio. The mean amplitudes and pulse waiting times increase with the line-averaged density across devices, while the pulse duration times remain constant. Whereas the variation in waiting times is gradual across the density scan, the mean amplitudes increase abruptly as the density profile broadens and flattens for Alcator C-Mod. The blob waiting times decrease with increasing plasma current and the toroidal magnetic field, while they increase with aspect ratio for conventional tokamaks. The duration times follow the same trends as the waiting times in these parameters but vary more slowly, resulting in the trends in the waiting times dominating the intermittency level of the fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The management of tumor motions in the stereotactic irradiation to lung cancer under the use of Abches to control active breathing

Purpose: Breathing control is crucial to ensuring the accuracy of stereotactic irradiation for lung cancer. This study monitored respiration in patients with inoperable nonsmall-cell lung cancer using a respiration-monitoring apparatus, Abches, and investigated the reproducibility of tumor position in these patients. Methods: Subjects comprised 32 patients with nonsmall-cell lung cancer who were administered stereotactic radiotherapy under breath-holding conditions monitored by Abches. Computed tomography (CT) was performed under breath-holding conditions using Abches (Abches scan) for treatment planning. A free-breathing scan was performed to determine the range of tumor motions in a given position. After the free-breathing scan, Abches scan was repeated and the tumor position thus defined was taken as the intrafraction tumor position. Abches scan was also performed just before treatment, and the tumor position thus defined was taken as the interfraction tumor position. To calculate the errors, tumor positions were compared based on Abches scan for the initial treatment plan. The error in tumor position was measured using the BrainSCAN treatment-planning device, then compared for each lung lobe. Results: Displacements in tumor position were calculated in three dimensions (i.e., superior-inferior (S-I), left-right (L-R), and anterior-posterior (A-P) dimensions) and recorded as absolute values. For the whole lung, average intrafraction tumor displacement was 1.1 mm (L-R), 1.9 mm (A-P), and 2.0 mm (S-I); the average interfraction tumor displacement was 1.1 mm (L-R), 2.1 mm (A-P), and 2.0 mm (S-I); and the average free-breathing tumor displacement was 2.3 mm (L-R), 3.5 mm (A-P), and 7.9 mm (S-I). The difference between using Abches and free breathing could be reduced from approximately 20 mm at the maximum to approximately 3 mm in the S-I direction for both intrafraction and interfraction positions in the lower lobe. In addition, maximum intrafraction tumor displacement with the use of Abches was 4.5 mm (S-I) in the lingular segment. These results suggest that use of the Abches system can reduce deviations in tumor position to levels below those achieved under free breathing, irrespective of the tumor location. Conclusions: Respiratory control with high accuracy and reproducibility is required for high-precision radiotherapy of inoperable nonsmall-cell lung cancer and was achieved using Abches in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-207-04: Reconstruction Artifact Reduction in X-Ray Cone Beam CT Using a Treatment Couch Model

Purpose: to mitigate artifacts induced by the presence of the RT treatment couch in on-board CBCT and improve image quality Methods: a model of a Varian IGRT couch is constructed using a CBCT scan of the couch in air. The model is used to generate a set of forward projections (FP) of the treatment couch at specified gantry angles. The model couch forward projections are then used to process CBCT scan projections which contain the couch in addition to the scan object (Catphan phantom), in order to remove the attenuation component of the couch at any given gantry angle. Prior to pre-processing with the model FP, the Catphan projection data is normalized to an air scan with bowtie filter. The filtered Catphan projections are used to reconstruct the CBCT with an in-house FDK algorithm. The artifact reduction in the processed CBCT scan is assessed visually, and the image quality improvement is measured with the CNR over a few selected ROIs of the Catphan modules. Results: Sufficient match between the forward projected data and the x-ray projections is achieved to allow filtering in attenuation space. Visual improvement of the couch induced artifacts is achieved, with a moderate expense of CNR. Conclusion: Couch model-based correction of CBCT projection data has a potential for qualitative improvement of clinical CBCT scans, without requiring position specific correction data. The technique could be used to produce models of other artifact inducing devices, such as immobilization boards, and reduce their impact on patient CBCT images.

60 APPLIED LIFE SCIENCES↗

A self-driving microscope and the Atomic Forge

The electron microscope predates the transistor and the charge-coupled device (CCD). The opportunity to integrate these advancements into the electron microscope was seized and revolutionized in the modern (scanning) transmission electron microscope (STEM). Real-time analysis became possible and is now routine. Consider the efforts one would have to undertake to perform a Fourier transform in the days when images were acquired by exposing photographic plates. Indeed, it was real-time data analysis that enabled the measurement and correction of aberrations in modern instrumentation.1 What are the next opportunities on the horizon for the STEM?

36 MATERIALS SCIENCE↗

Ultrafast Electron Microscopy for Spatial-Temporal Mapping of Charge Carriers

This LDRD supported efforts to significantly advance the scanning ultrafast electron microscope (SUEM) for spatial-temporal mapping of charge carrier dynamics in semiconductor materials and microelectronic devices. Sandia's SUEM capability in Livermore, CA, was built and demonstrated with previous LDRD funding; however, the stability and usability of the tool limited the throughput for analyzing samples. A new laser alignment strategy improved the stability of the SUEM, and the design and characterization of a new micro-channel plate (MCP)- based detector improved the signal-to-noise of the SUEM signal detection. These enhancements to the SUEM system improved throughput by over two orders of magnitude (before, a single time series of SUEM measurements would take several days to several weeks to acquire; now, the same measurements can be completed in~90 minutes in an automated fashion). The SUEM system can now be routinely used as an analytical instrument and will be a central part of several multi-year projects starting in FY22.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗