Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

From ETROC to VTROC

The Endcap Timing ReadOut Chip (ETROC) is designed to process LGAD signals with time resolution down to about 40-50ps per hit, to reach 30-35ps per track with two detector layers. The ETROC2 is the first full size (16x16) prototype design and is fully compatible with the final chip specifications in terms of functionality. The ETROC2 has been extensively tested recently. In this talk, the testing results of the ETROC2 will be presented first, including performance study using charge injection, laser and beam, as well as TID testing and wafer probe testing to study the yield. In addition, future challenges of precision position and timing ASIC design will be discussed, based on what we have learned from the ETROC development, and how the challenges could be addressed in the VTROC, Vertically integrated Timing ReadOut chip (funded as SBIR phase 2) for precision position and timing detector R&D.

Liu, Ted↗

A geometrical result regarding time-of-arrival lightning location

One reason for investigating Lightning Detection And Ranging (LDAR) is to validate data from the Optical Transient Detector (OTD). A Time-Of-Arrival (TOA) procedure may be used with radio wave portions of lighting signatures. An antenna is in place at KSC.

Solakiewicz, Richard↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Parametric Down Conversion at the APS Synchrotron

We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. We use an incoming pump beam at 22 keV to observe the simultaneous, elastic emission of down-converted photon pairs generated in a diamond crystal. The pairs are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed by measuring time-energy correlations in the detector signal, where photon pairs within an energy window ranging from 10 to 12 keV are only observed at short time differences. By systematically varying the crystal misalignment and detector positions, we obtain results that are consistent with the constant total of the down-converted signal.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NuSTAR and IXO Missions

NuSTAR (Nuclear Spectroscopic Telescope Array) and IXO (International X-ray Observatory) missions are two of NASA X-ray missions for the coming decade. NuSTAR is a small explorer class mission that will for the first time use a multilayer-coated X-ray mirror assemblies to focus X-rays up to 80 keV. Among other objectives, its major science objective will be to conduct surveys to identify hard X-ray sources and to resolve the diffuse X-ray background. IXO, a collaborative mission of NASA, ESA, and JAXA, will be an observatory class mission. It will have a 3m in diameter X-ray mirror assembly with unprecedented photon collection area with a suite of focal plane detectors: a grating system, a large format CCD imaging system, a calorimeter, a polarimeter, and a high resolution and fast timing detector. It will significantly advance the spectroscopic studies of black holes, neutron stars, AGN, IGM, and nearly every other aspect of the X-ray universe. In this talk I will describe the instruments and scientific objectives of these two missions.

Zhang, William W.↗

Heat Transfer Issues in Thin-Film Thermal Radiation Detectors

The Thermal Radiation Group at Virginia Polytechnic Institute and State University has been working closely with scientists and engineers at NASA's Langley Research Center to develop accurate analytical and numerical models suitable for designing next generation thin-film thermal radiation detectors for earth radiation budget measurement applications. The current study provides an analytical model of the notional thermal radiation detector that takes into account thermal transport phenomena, such as the contact resistance between the layers of the detector, and is suitable for use in parameter estimation. It was found that the responsivity of the detector can increase significantly due to the presence of contact resistance between the layers of the detector. Also presented is the effect of doping the thermal impedance layer of the detector with conducting particles in order to electrically link the two junctions of the detector. It was found that the responsivity and the time response of the doped detector decrease significantly in this case. The corresponding decrease of the electrical resistance of the doped thermal impedance layer is not sufficient to significantly improve the electrical performance of the detector. Finally, the "roughness effect" is shown to be unable to explain the decrease in the thermal conductivity often reported for thin-film layers.

Barry, Mamadou Y.↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Trends in measurement of solar vector magnetic fields using the Zeeman effect

Trends in spectropolarimetry as applied to the problem of Zeeman effect measurement are discussed. The use of detector arrays to improve observing efficiency is obtained. Which required new polarization modulation schemes that match the time required to read detector arrays. Another significant trend is narrowband filters, to improve angular and temporal coverage, and to Fourier transform spectrometers, to improve spectral coverage and precision. Low-polarization designs and improved methods for compensating instrumental polarization were developed. A requirement for high angular resolution suggests using adaptive optical devices to subdue the effects of bad seeing. The ultimate strategy to beat the seeing is to loft the telescope above the atmosphere such as is planned with a 30-cm telescope in 1985 and a 1250-cm telescope in 1990.

Harvey, J. W.↗

Angular resolution of air-shower array-telescopes

A fundamental limit on the angular resolution of air shower array-telescopes is set by the finite number of shower particles coupled with the finite thickness of the particle swarm. Consequently the angular resolution which can be achieved in practice depends in a determinant manner on the size and number of detectors in an array-telescope, as well as on the detector separation and the timing resolution. It is also necessary to examine the meaning of particle density in whatever type of detector is used. Results are given which can be used to predict the angular resolution of a given instrument for showers of various sizes, and to compare different instruments.

Linsley, J.↗

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two wavelength satellite laser ranging using SPAD

When ranging to satellites with lasers, there are several principal contributions to the error budget: from the laser ranging system on the ground, from the satellite retroarray geometry, and from the atmosphere. Using a single wavelength, we have routinely achieved a ranging precision of 8 millimeters when ranging to the ERS-1 and Starlette satellites. The systematic error of the atmosphere, assuming the existing dispersion models, is expected to be of the order of 1 cm. Multiple wavelengths ranging might contribute to the refinement of the existing models. Taking into account the energy balance, the existing picosecond lasers and the existing receiver and detection technology, several pairs or multiple wavelengths may be considered. To be able to improve the atmospheric models to the subcentimeter accuracy level, the differential time interval (DTI) has to be determined within a few picoseconds depending on the selected wavelength pair. There exist several projects based on picosecond lasers as transmitters and on two types of detection techniques: one is based on photodetectors, like photomultipliers or photodiodes connected to the time interval meters. Another technique is based on the use of a streak camera as an echo signal detector, temporal analyzer, and time interval vernier. The temporal analysis at a single wavelength using the streak camera showed the complexity of the problem.

Prochazka, Ivan↗

Further characterization of IRAS doped silicon detectors

Measurements made on several doped-silicon detectors are reported. Topics discussed include: Si:Sb detector, the effects of detector bias on dielectric relaxation; characterization of spontaneous noise and gamma-induced spikes and their circumvention; and the time response of two detectors to step changes in the background photon flux density. Several potential system programs are indicated.

Source record↗

Analysis of STIS time-tag data

Very high time resolution data can be obtained from the Space Telescope Imaging Spectrograph (STIS) Multi-Anode Microchannel Array (MAMA) detectors using the time-tag observing mode. In this mode, the photon events are not accumulated onboard the spacecraft. Instead, each event is recorded internally and transmitted to the ground as an X and Y location with an event time. Event times are recorded in units of 125 microseconds. Analysis of STIS Crab Pulsar data demonstrates that a time resolution of approaching 125 microseconds can be achieved. Furthermore, the time-tag observing mode has been demonstrated to be a very powerful diagnostic tool and can be used to increase the resolution of both imaging and spectral data.

Lindler, Don J.↗

Excess Heat Capacity in Mo/Au Transition Edge Sensor Bolometric Detectors

Excessheat capacity in a bolometric detector has the consequence of increasing or leading to multiple device time con-stants.The Mo/Au bilayer transition edge sensor (TES) bolo-metric detectors intended for the high resolution mid-infrared spectrometer (HIRMES) have two response time, one of which is a few times longer than that estimated from materials used in the design. The relative contribution of this settling time to the overall time response of the detectors is roughly proportional with the pixel area, which ranges between ~0.3 and 2.6 mm2.Use of laser ablation to remove sections of the silicon membranes comprising the pixels results in a detector response with a smaller contribution from the secondary time constant.Additional information about the nature of this excess heat capacity is gleaned from glancing in-cidence x-ray diffraction, which reveals the presence of molyb-denum silicides near the silicon surface from the bi-layer deposi-tion.Quantitative analysis of the concentration of excess molyb-denum, estimated with secondary ion mass spectroscopy, is com-mensurate to the additional heat capacity needed to explain the anomalous time response of the detectors.

HIRMES↗

Late Prompt Fission Gamma Rays from 235 U(n,f) and 252 Cf(sf)

Two measurements of fission γ rays were performed with the DANCE and NEUANCE arrays using the reactions 235 U(n, f) and 252 Cf(sf). Utilizing the fast time response of the detectors and a method for estimating the accidental background, we obtained the energy spectrum of the late prompt fission γ rays as a function of the time since fission. The experimental results are compared with predictions of the code CGMF folded with GEANT4 simulations of the detector response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Alignment of the ATLAS Inner Detector in Run 2

The performance of the ATLAS Inner Detector alignment has been studied using pp collision data at s√=13TeV collected by the ATLAS experiment during Run 2 (2015–2018) of the Large Hadron Collider (LHC). The goal of the detector alignment is to determine the detector geometry as accurately as possible and correct for time-dependent movements. The Inner Detector alignment is based on the minimization of track-hit residuals in a sequence of hierarchical levels, from global mechanical assembly structures to local sensors. Subsequent levels have increasing numbers of degrees of freedom; in total there are almost 750,000. The alignment determines detector geometry on both short and long timescales, where short timescales describe movements within an LHC fill. The performance and possible track parameter biases originating from systematic detector deformations are evaluated. Momentum biases are studied using resonances decaying to muons or to electrons. The residual sagitta bias and momentum scale bias after alignment are reduced to less than ~0.1 TeV -1 and 0.9×10 -3 , respectively. Impact parameter biases are also evaluated using tracks within jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulated Energy Response in a Multiplicity Detector

Neutron multiplicity analysis is used for many applications, including nonproliferation and criticality safety. Multiplicity detectors have advantages over total neutron counting as they provide the ability to assess both multiplication and mass in fissionable material. In addition, multiplicity detectors can generate real-time information, e.g., dose estimation. The ability to evaluate the detector efficiency in each application is of primary importance in producing meaningful analyses. Multiplicity detectors usually house 3 He tubes within a polyethylene moderator. If the tubes are located behind different thickness of polyethylene, they will have different energy responses. This paper assesses 3 He tube efficiency as a function of neutron energy for a specific multiplicity detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗