DOE OSTI · 2001056
X-ray Parametric Down Conversion at the APS Synchrotron
Abstract
We present measurements of X-ray Parametric Down Conversion at the Advanced Photon Source synchrotron facility. We use an incoming pump beam at 22 keV to observe the simultaneous, elastic emission of down-converted photon pairs generated in a diamond crystal. The pairs are detected using high count rate silicon drift detectors with low noise. Production by down-conversion is confirmed by measuring time-energy correlations in the detector signal, where photon pairs within an energy window ranging from 10 to 12 keV are only observed at short time differences. By systematically varying the crystal misalignment and detector positions, we obtain results that are consistent with the constant total of the down-converted signal.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Tarvin, Hilary M., Walker, Gary P., Sheehan, Sean M., Wunschel, William L.. 2023-07-01. X-ray Parametric Down Conversion at the APS Synchrotron. https://www.osti.gov/biblio/2001056
Cite the original work for its findings. Save a collection to share your selection of sources.