Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

REGULATORY TESTING AND POSTTEST ANALYSIS OF THE DPP-3 TYPE B SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. Therefore, a comprehensive and rigorous system of packaging requirements are required. The purpose of this test protocol is to determine the effects of drop testing on package performance in a Type B shipping package (DPP-3). Required physical tests for the DPP-3 package include normal conditions of transport and hypothetical accident conditions test requirements. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73 were measured. The posttest helium leak test showed a leak rate less than 1 × 10-7 He-cc/sec which means that the containment boundary was maintained after the regulatory testing, therefore maintaining a leak tight environment. To determine the amount of change in the package performance measurements, statistical analyses were conducted using SPSS version 26. The null hypothesis of the testing was that there would not be a change in the measurements from pre to post-testing large enough to find statistical significance. Therefore, a finding of statistical significance indicated too much variability in the package design and was deemed an unfavorable finding. A repeated measures t-test was used to analyze the drum lids and CV torques. A one-way ANOVA was used to analyze height and diameter packages. Results of the repeated measures t-test indicated that all six containment vessel lid torques were statistically significant. However only three out of the six drum lid torques were statistically significant. Therefore, design of the lids caused more variability than necessary when subjected to the following drop tests: 1.) horizontal and cold; 2.) vertical lid down; and 3.) corner with lid up. Results of the one-way ANOVA analysis on height indicated that four out of the six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to the following drop tests: 1.) horizontal hot; 2.) horizontal cold; 3.) corner lid up; and 4.) corner lid down. Results of the one-way ANOVA analysis on diameter indicated that all six CTUs were statistically significant. Thus, design of the CTUs caused more variability then necessary when subjected to all of the tests. The DPP-3 design has been shown to be an acceptable design for the transport of radioactive materials. However, results of the statistical analysis reveal a possible improvement in package and test design to reduce variability in package performance measurement before and after testing.

Martinez, Oscar↗

REGULATORY TESTING AND 3D SCANNING METHODOLOGY OF THE DPP-1 TYPE SHIPPING CONTAINER FOR NCT AND HAC TESTS

The safe transportation of radioactive material using appropriately designed and certified transportation packages is important to protect the public and environment. In the United States of America all transportation of radioactive material is regulated by the Department of Transportation (DOT) along with input by the Nuclear Regulatory Commission (NRC). All packages that contain radioactive material requires that it be transported and regulated by the requirements set by the DOT Class 7 hazardous material transportation. Federal regulations place strict administrative controls on the transport of radioactive materials. The two main goals for transporting radioactive materials are 1. Safety should be the primarily focused on the package because it is the first line of defense. 2. Package integrity should be directly related to the degree of the hazard of the radioactive material contents. The two-part goal ensures that the right package is used. Type B packages are designed to transport radioactive materials with the highest level of radioactivity. Examples of material transported in Type B packagings include spent nuclear fuel, high-level radioactive waste, and high concentrations of other radioactive materials. The purpose of this test protocol is to determine the effects of drop and thermal testing on package performance in a Type B shipping package (DPP-1). Required physical tests for the DPP-1 package include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The preparation, regulatory testing, and post-test evaluation of a Type B shipping package tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. Six packages were tested and the responses when subjected to the HAC sequence of free drop, puncture, and thermal tests according to 10 CFR 71.73(c)(1), (c)(2), (c)(3) and (c)(4) were measured. The Free Drop, Crush and Puncture tests were performed at the NTRC in Knoxville, TN, and the Thermal tests were performed Southwest Research Institute in San Antonio, TX. The test units were subjected to a pre-operational leak testing before the NCT and HAC tests and a post-operational leak test and a helium leak test once regulatory testing was complete. Finally, all test units were scanned with a handheld blue light scanner to capture a 3D CAD geometry of the test units in the deformed shape. The handheld scanner provided the most effective and reliable way to acquire accurate 3D measurements of the test unit. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeatable results of the deformed shape of the test units.

Martinez, Oscar↗

BOS Gas Detection Pipeline (Integrated System for Optical Hydrogen Detection Using Background Oriented Schlieren and Machine Learning) [SWR-26-007]

This software is the world's first integrated background oriented schlieren and machine learning-based leak detection system. The system provides real time visualization of gas leaks and machine learning interpenetration of leak severity. The software is supplemented by SWR-25-177, "gpu_piv (Graphics Processing Unit Accelerated Background Oriented Schlieren Algorithm", also developed by the National Laboratory of the Rockies. SEE DOECODE ID 182832.

Palin, Ian [National Laboratory of the Rockies (NL↗

Using Models to Predict the Hygrothermal Performance of Equipment and Piping Insulation

The development of hygrothermal models began in earnest in the 1990s, with the initial emphasis on the performance of building envelope systems. Numerous large-scale building envelope failures associated with water intrusion drove this development. The physical principles of moisture transfer that apply to building envelopes are equally valid for equipment and piping insulation systems. The main advantage of modeling is that carefully characterized models can predict the long-term hygrothermal performance of any system under different climatic and interior conditions. Thermal insulations are commonly used on outdoor equipment and piping for different applications, such as thermal energy conservation and freeze protection. The insulated equipment usually experiences moisture intrusion due to many factors, such as the duration and frequency of moisture exposure, equipment operating temperature, insulation type, exposure temperature, weather conditions, equipment thermal cycling, and weatherproofing condition. Hygrothermal models have been employed to estimate the moisture pickup of insulated equipment and piping systems, as well as the moisture redistribution and subsequent change in thermal performance as these systems become contaminated with moisture. The hygrothermal model provides insights on the parameters influencing the time of wetness, the lateral redistribution of moisture along the pipe away from the leak, and the ease by which water escapes the insulation/jacketing systems. It has been shown that the moisture leak effect decreases rapidly with distance from the leak and that one- and two-dimensional hygrothermal simulations help to identify solutions to reduce conditions that support corrosion under insulation (CUI).

Shrestha, Som↗

Thin Film Hydrogen Sensor Development, Testing and Integration Into Low Cost Wireless Sensing Systems (SBIR Phase 1 Final Report)

Element One, Inc. is reporting on the results of its DOE SBIR Phase I project for the development and testing of low-cost thin film hydrogen sensors and their subsequent integration into wireless sensing systems and networks. This work is based on Element One’s chemo-chromic sensing technology which indicates hydrogen presence (leaks) colorimetrically and electronically with no power required. The lack of required power makes them particularly suitable for passive Radio Frequency Identification Device (RFID) technology which can be deployed affordably and abundantly to detect leaks in hazardous environments. Element One built upon its experience with chemochromic materials that change color in the presence of hydrogen. Both thin films and pigments have been used, but thin films have the ability to change conductivity by more than three orders of magnitude making them ideal for resistive sensors. Prototype sensors were fabricated, tested and characterized. For the wireless component, Element One partnered with Esensor, Inc. to construct and test a wireless sensing network. The network was tested and validated at the National Renewable Energy Laboratory (NREL) in February and March. The tests involved exposing the wireless system to hydrogen gas concentrations of 1% and 5%. There were no significant problems encountered, and the system is ready for commercial development. The system demonstrated the viability of wireless hydrogen sensing networks for hydrogen leak detection and other applications.

08 HYDROGEN↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Technical Justifications for Liquid Hydrogen Exposure Distances

The previous separation distances in the National Fire Protection Association (NFPA) Hydrogen Technologies Code (NFPA 2, 2020 Edition) for bulk liquid hydrogen systems lack a well-documented basis and can be onerous. This report describes the technical justifications for revisions of the bulk liquid hydrogen storage setback distances in NFPA 2, 2023 Edition. Distances are calculated based on a leak area that is 5% of the nominal pipe flow area. Models from the open source HyRAM+ toolkit are used to justify the leak size as well as calculate consequence-based separation distances from that leak size. Validation and verification of the numerical models is provided, as well as justification for the harm criteria used for the determination of the setback distances for each exposure type. This report also reviews mitigations that could result in setback distance reduction. The resulting updates to the liquid hydrogen separation distances are well-documented, retrievable, repeatable, revisable, independently verified, and use experimental results to verify the models.

08 HYDROGEN↗

Assessing the Value of Seismic Amplitude Versus Offset (AVO) Attributes for CO2 Storage Project Using a Bayesian Network Model for Decision Support

Attributes versus offset (AVO) are a set of measurements to analyze how the characteristics of reflected seismic waves change as a function of the offset. It can be useful for monitoring CO2 storage sites because the presence of leaked CO2 into the overlying aquifer can change the properties of the rocks and pore fluids composition that can alter the way seismic waves reflect and their amplitudes. The time-lapse changes in AVO attributes derived from repeat seismic surveys can help identify anomalies or shifts in the subsurface that could potentially be used as an indicator for CO2 leak detection. Our study leverages multiple seismic attributes derived from synthetic seismic data and Bayesian network model to quantify the probability of leak detection in the overlying aquifer above the storage reservoir. It helps to quantify the value of individual seismic attributes at multiple monitoring periods based upon their sensitivities.

Kumar, Abhash↗

Methane Integrated Monitoring and Measurement System Design

Methane (CH 4 ), an abundant greenhouse gas, is the second largest contributor to global warming after carbon dioxide (CO 2 ). In comparison to CO 2 , CH 4 has a larger warming effect over a much shorter lifetime. While technologies to radically reduce global carbon dioxide emissions are materializing, rapid reductions in methane emissions are needed to limit near-term warming. Methane is primarily emitted as a byproduct from agricultural activities and energy extraction/utilization and is currently monitored via bottom-up (i.e., activity level) or top-down (via airborne or satellite retrievals) approaches. However, significant methane leaks remain undetected, and emission rates are challenging to characterize with current monitoring frameworks. In this report, we study methane leaks from oil and gas infrastructure using a tiered monitoring approach that combines bottom-up and top-down approaches in an integrated framework. We describe the individual advantages of bottom-up and top-down sensors in both stationary and mobile settings before characterizing how a fully integrated framework can improve predictions and uncertainties of potential leak locations and their emission rates. Further, we study the impact of different atmospheric (wind) conditions on integrated methane monitoring and develop a probabilistic approach to optimal sensor placement, thereby shortening detection times and improving monitoring capabilities. Last, we discuss how biogenic flux modeling can be used to improve assessment of background methane concentrations needed to fully assess the sensitivity of a tiered monitoring system.

54 ENVIRONMENTAL SCIENCES↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An initial effort to study the influence of pitting in SAVY containers

As part of a broader effort to investigate a critical pit depth, below which SAVY containers fail a leak test after a drop test, surrogate testing using pristine SAVY container material was investigated. The original study involved producing pits in a SAVY wall to depths 35% to 55% of the wall thickness and subjecting the pitted container to a drop test under prototypic conditions. Subsequent leak testing after drop testing showed the container passed and that the pit size distribution and drop conditions were not sufficient to cause a leak test failure in this specific container.

36 MATERIALS SCIENCE↗

Reducing Methane Emissions with an Engine Fuel Reformer

Southwest Research Institute (SwRI) designed and demonstrated a compact, plasma-based fuel reformer designed to reduce methane leaks from natural-gas engines used in pipeline compression and industrial power applications. The system uses pulsed electrical discharges to convert a small portion of methane (CH4) into hydrogen (H2) and light hydrocarbons, promoting more complete combustion and reducing unburned methane in the exhaust. The reformer was evaluated through bench-scale testing, high-flow facility testing, and engine-integration testing on representative low-speed and high-speed natural-gas engines. Measured methane-leak reductions ranged from 1 to 27 percent, depending on engine type and operating condition, while reformer energy consumption remained below one percent of total engine output. Design refinements addressed thermal and electrical challenges, resulting in reliable operation with minimal impact on engine control systems. The project achieved all performance objectives within budget and schedule, produced a patentable pulsed-power system design, and established a scalable, energy-efficient pathway for mitigating methane leaks from existing natural-gas engine infrastructure.

03 NATURAL GAS↗

Development of a Digital Twin for Hydrogen Dispersion and Safety Assessment in an Electrolyzer Based Hydrogen Production Facility

Digital twin models are virtual representations of physical systems that use real-time data to simulate and optimize performance. This study presents the development and initial implementation of a digital twin (DT) for the electrolyzer-based hydrogen production facility at NREL's Advanced Research on Integrated Energy Systems (ARIES), focused on enhancing safety and optimizing sensor placement through physics-based simulations and metadata integration. The DT incorporates detailed facility-specific information, including component layout, leak locations, and controlled release parameters, to model hydrogen dispersion under varying environmental conditions. Using steady-state computational fluid dynamics (CFD) simulations informed by real meteorological data, such as wind speed, direction, and vertical wind profiles, the DT enables visualization of hydrogen plume behavior and spatial concentration distributions. Comparative analysis between high and low wind speed scenarios illustrates the significant influence of wind dynamics on plume shape and extent, with horizontal momentum dominating dispersion at higher speeds, while buoyancy effects become more prominent under low wind conditions. These simulations generate a rich dataset embedded within the DT, allowing users to assess potential leak outcomes and identify optimal sensor locations based on concentration thresholds. The model supports scenario-based analysis to guide safety strategies and equipment deployment for open-area hydrogen infrastructure. The digital twin thus serves as a dynamic platform for virtual prototyping, providing predictive insight into hydrogen behavior and enhancing risk-informed decision-making. This initial phase establishes a validated foundation for future integration of transient, uncontrolled leak scenarios and real-time sensor feedback, positioning the DT as a critical tool for safety design, operational planning, and adaptive monitoring in hydrogen systems. Overall, the approach demonstrates the value of combining environmental data with digital simulations to inform safer and more efficient deployment of hydrogen technologies.

08 HYDROGEN↗

Industry Scan of Non-SF6 Gas-Insulated Technologies

Sulfur Hexafluoride (SF 6 ) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF 6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF 6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF 6 one of the leading sources of anthropogenic climate change. Since SF 6 recognition as a significant contributor to climate change, most governments and organizations have sought ways to reduce or eliminate their use of this gas. Many utilities have initiated leak monitoring and repair programs which have significantly reduced emissions of this gas into the atmosphere. While leak reduction programs have been effective at reducing emission rates in the developed world, leak rates remain frozen at ~1% annually. However, one of the largest and fastest growing markets for this gas is in the developing world where emissions standards are often lacking (P&S Intelligence. 2023). To fully eliminate the environmental impacts of SF 6 , alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF 6 , at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. This report was commissioned by the United States Department of Energy’s Office of Electricity under the Transformer Resilience and Advanced Components (TRAC) program to assess the state of industry adoption and manufacturing capability for SF 6 -free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption. While this report is tailored to the United States, the findings should be relevant to all stakeholders seeking to reduce SF 6 emissions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Embedding of Optical Fibers with Electric Field Assisted Sintering

The Electric Field Assisted Sintering (EFAS) technique was used for embedding the fibers, involving rapid heating via an electric current and pressure, reducing fiber exposure to high temperatures. Stainless steel guide tubes were inserted at the fiber-matrix junctions to prevent fiber breakage during the sintering process. The study varied key EFAS parameters—temperature (800°C to 980°C), pressure (40-50 MPa), and hold time (5-10 minutes)—to assess how they influenced fiber embedding. After embedding, the fibers were inspected using optical frequency domain reflectometry (OFDR) to evaluate optical losses and strain along the fiber length. The OFDR scans confirmed that the fibers remained intact, and subsequent transmission tests demonstrated no macroscopic fractures. The embedded samples were also analyzed using scanning electron microscopy (SEM) and X-ray computed tomography (CT) scans. These tests confirmed good bonding between the fiber and matrix with no cracking, though some porosity was present in samples fabricated at lower temperatures. At higher temperatures (980°C), the fiber-matrix bonding was continuous and defect-free, with metal coatings aiding in the bonding process. Elemental analysis showed interdiffusion between the fiber coatings and matrix materials, particularly between the gold coating and stainless steel. Helium leak tests revealed that lower sintering temperatures resulted in matrix porosity, causing leaks, but samples fabricated at 980°C were leak-tight.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Study to develop improved methods to detect leakage in fluid systems, phase 2

An ultrasonic contact sensor engineering prototype leak detection system was developed and its capabilities under cryogenic operations demonstrated. The results from tests indicate that the transducer performed well on liquid hydrogen plumbing, that flow and valve actuation could be monitored, and that the phase change from gaseous to liquid hydrogen could be detected by the externally mounted transducers. Tests also demonstrate the ability of the system to detect internal leaks past valve seats and to function as a flow meter. Such a system demonstrates that it is not necessary to break into welded systems to locate internal leaks.

Janus, J. C.↗

Tracer sensitive tapes

A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

Burrows, W. H.↗

Hydrogen detection study

The effectiveness was assessed of a hydrogen (H2) detection concept for regenerative environmental control life support systems (EC/LSS). The concept evaluated was that utilized for the electrochemical depolarized concentrator (EDC) design, constructed, and tested for the EC/LSS space station prototype program. The EDC contains combustible gas detectors (CGDs) which were evaluated with H2. The CGDs were evaluated for linearity, position sensitivity, reproducibility, ambient effects, repeatability, speed of response, recovery time, and interchangeability. The effectiveness of CGDs located within the EDC for sensing H2 leaks at various line replaceable units in the subsystem was determined. The effects of H2 leak rate, H2 concentration of leaking gas and air currents in the vicinity of the EDC were determined. Proposed improvements for the H2 detection concept were documented and alternative H2 detection approaches were identified and analyzed.

Shumar, J. W.↗