Engineering Papers⌕ Search

NASA NTRS · 19720008639

Tracer sensitive tapes

Abstract

A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Burrows, W. H.. 1971-11-03. Tracer sensitive tapes. https://engineeringpapers.com/record/nasa%3A19720008639/tracer-sensitive-tapes