Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “housing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A continuum model for heat and mass transfer in moving-bed reactors for thermochemical energy storage

In this work, a continuum heat and mass transfer model coupling transport phenomena and high-temperature thermochemical reactions is developed for stationary packed-bed and counter-flow moving-bed reactors. After presenting the general modeling framework, we focus on the 2D axisymmetric version of the model for which validation is conducted with experimental results for a packed-bed reactor in the literature for manganese-iron oxide reduction/oxidation and an in-house counter-flow moving-bed reactor for magnesium-manganese oxide reduction up to 1450 °C. Transient simulation results including the local distributions of gas/solid temperatures, oxygen concentration and the extent of reaction, as well as the various energy flow components and energy conversion efficiencies are reported. The results based on the 2D axisymmetric model are also compared with those obtained from a previous 1D model. The comparison shows that capturing the radial variation is critical in reactor modeling and the 2D results demonstrate improved agreement with experiments. Specifically, large temperature variations along the radial direction are observed especially in the reaction zone; this non-uniform radial temperature distribution has a significant effect on the chemical reaction extent due to its strong dependence on temperature; and the overall oxygen concentration at the reactor exit and the predicted system efficiency are slightly lower in the 2D model compared to the 1D model. Finally, the present heat and mass transfer model can provide valuable insights into reactor design, scale-up, and operating conditions selection to maximize system energy storage efficiency.

25 ENERGY STORAGE↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plant-wide modeling and techno-economic analysis of a direct non-oxidative methane dehydroaromatization process via conventional and microwave-assisted catalysis

Direct non-oxidative methane dehydroaromatization (DHA) process via conventional and microwave (MW)-assisted thermo-catalytic catalysis is studied. Rate models for methane DHA reactions, including the effect of catalyst deactivation, are developed by using the in-house experimental data. Model results for gas concentration profile and catalyst deactivation are in good agreement with the experimental data. This rate model is then used for the development of dynamic multi-scale, multi-physics commercial-scale reactor models. Total number of fixed bed reactors desired for a cyclic steady state process is estimated. Plant-wide models are then developed for conventional and MW-assisted processes for producing products of desired specifications. Techno-economic analysis of the methane DHA process is undertaken. Economics of these methane DHA processes are compared with the typical multi-step natural gas to aromatics production process via methanol synthesis. Sensitivity of internal rate of return (IRR) and net present value (NPV) to various economic and process parameters such as plant scale, desired rate of return, reactor cost, feedstock and utility cost, catalyst variable cost, and MW reactor cost is studied. Here, electric equivalent efficiency of the conventional methane DHA process is found to be 69.2 % and 67.3 % at 750 °C and 800 °C, respectively, while the MW-assisted methane DHA process has the electric equivalent efficiency of 48.9 % at 800 °C. IRRs of the conventional methane DHA process at 750 °C and 800 °C, and MW-assisted process are 15.2 %, 17.5 %, and 18.8 %, respectively for a methane feed flowrate of 19,782 kg/h, while the IRR of the multi-step natural gas to aromatics production process is estimated to be 0 % for the same plant scale. Impact of change in the methane price, electricity price, and catalyst cost is found to be considerable on the process economics, while the cost of the MW reactor is found to have negligible impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in benchmarking and round robin testing for PEM water electrolysis: Reference protocol and hardware

While the number of publications in the PEM water electrolysis community increases each year, no common ground concerning reference hardware (test cells and test bench) and testing protocols has been yet established. This would, however, be necessary for the comparability of experimental results. First attempts for such reference hardware and procedures have been made in the framework of the Task 30 Electrolysis within the Technology Collaboration Programme on Advanced Fuel Cells (AFC TCP) of the International Energy Agency (IEA). Since then, improvements of both the test hardware (test cell and components) as well as the measurement protocol were identified, and a revised methodology and key results based on a comprehensive measurement series have been obtained. A detailed protocol for testing commercial reference components with a reference laboratory test cell developed in-house by Fraunhofer ISE is presented. For evaluation of the protocol and the hardware, it was tested at three different institutions at the same time. Impedance spectroscopic and polarization data was acquired and analyzed. The obtained differences in performance were calculated to give the community an expectation window to compare own data to. Finally, the importance of a thorough temperature control and the conditioning phase are demonstrated.

08 HYDROGEN↗

A high-performance intermediate temperature reversible solid oxide cell with a new barrier layer free oxygen electrode

The best solution to address the critical durability issue of solid oxide electrolytic cells (SOECs) for high-efficiency and high-rate H 2 production is to lower the operating temperature without sacrificing the performance. Developing high performance oxygen electrodes (OEs) is a key to capitalizing this solution. Here, in this paper, we report on a highly active OE for intermediate temperature ZrO 2 -based SOECs without a CeO 2 barrier layer. The new barrier-layer-free (BLF) OE is a composite of two materials, (Bi 0.75 Y 0.25 ) 0.93 Ce 0.07 O 1.5±δ (BYC) that exhibits high oxide-ion conductivity and La 0.8 Sr 0.2 MnO 3 (LSM) that possesses a high electronic conductivity to enable fast oxygen reduction/evolution reactions (ORR/OER). Featuring a microscale porous BYC scaffold decorated with high surface area LSM nanoparticles (NPs), the new BLF-OE exhibited a low area specific resistance (ASR) of 0.10 Ω cm 2 at 650 °C in air. With 50%H 2 -50%H 2 O as a feed to hydrogen electrode (HE) and air to OE, the single cell performance achieved 588 mA cm -2 at 0.80 V in the fuel cell mode and 688 mA cm -2 at 1.30 V in the electrolytic mode at 650 °C. Our in-house testing showed that this level of performance was ~3.5x higher than the cell with the benchmark La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ -Ce 0.9 Gd 0.1 O 2-δ OE. The long-term durability testing under alternating fuel cell and electrolytic modes showed a low degradation rate of 0.10 mA cm -2 h -1 over 550 hours. These encouraging results showed the great promise of the newly developed BYC-LSM to be an excellent OE candidate for intermediate temperature SOECs.

25 ENERGY STORAGE↗

Upgrade of the mechanically pumped CO 2 two-phase cooling system for the alpha magnetic spectrometer on the international space station

This study describes the successful upgrade of a mechanically pumped CO 2 two-phase cooling system in space by designing a new pump module for the Alpha Magnetic Spectrometer-02 on the International Space Station. Key factors for mission success are emphasized, including achieving high coolant filling accuracy within 10% of the target and maintaining system stability within ±1 °C. The impact of adding radiators to improve cooling efficiency is examined, and it is found that operating multi-radiators out-of-phase does not significantly affect system reliability. The centrifugal pump design is shown to allow for better lubricant circulation, while the in-house designed controller incorporates protective measures to prevent cavitation, overheating, and over-current. Further, this research advances the understanding of circulation loop systems and their upgrades in space and demonstrates the potential for extending the lifetime of space-borne mechanically pumped two-phase cooling systems.

42 ENGINEERING↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Tribological properties of PDA + PTFE coating in oil-lubricated condition

In this work the tribological properties of 45 ± 2 μm-thick polytetrafluoroethylene (PTFE) and polydopamine (PDA) + PTFE coatings in oil-lubricated conditions were investigated under a normal load of 10 N and a linear reciprocating speed of 0.1 m/s. Both the PTFE and the PDA + PTFE coatings were deposited using an in-house spray-coating method. The PDA + PTFE coating was five times more durable compared to the PTFE coating in oil-lubricated conditions. Both PTFE and PDA + PTFE coatings showed lower COF in oil-lubricated conditions than in dry conditions. The nanomechanical properties measured by PeakForce Quantitative Nanomechanical (PFQNM) characterization method showed an increase in Young’s modulus and adhesion force for the PDA + PTFE coatings compared to the PTFE coatings. Chemical analysis showed that the cross-linking between PDA and PTFE polymer chains occurred during the high-temperature sintering procedure. Finally, the higher adhesion of PDA + PTFE coating to the cast iron substrate and the stronger cohesion due to the cross-linking between PDA and PTFE contributed to the higher durability of the PDA + PTFE composite coatings.

36 MATERIALS SCIENCE↗

Association of residential energy efficiency retrofits with indoor environmental quality, comfort, and health: A review of empirical data

This paper reviews empirical data from evaluations of the influence of residential energy efficiency retrofits on indoor environmental quality conditions and self-reported thermal comfort and health. The data were extracted from 36 studies described in 44 papers plus two reports. Nearly all reviewed studies were performed in Europe or United States. Most studies evaluated retrofits of homes with low-income occupants. Indoor radon and formaldehyde concentrations tended to increase after retrofits that did not add whole-house mechanical ventilation. Study-average indoor concentrations of nitrogen dioxide and volatile organic compounds other than formaldehyde increased and decreased with approximately equal frequency. Average indoor temperatures during winter typically increased after retrofits, usually by less than 1.5 °C. Dampness and mold, usually based on occupant's reports, almost always decreased after retrofits. Subjectively reported thermal comfort, thermal discomfort, non-asthma respiratory symptoms, general health, and mental health nearly always improved after retrofits. For asthma symptoms, the evidence of improvement slightly outweighed the evidence of worsening. There was insufficient evidence to determine whether changes in thermal comfort and health outcomes varied depending on the type of energy efficiency retrofit. The published research has numerous limitations including a lack of data from retrofits in warm-humid climates and minimal data on changes in objective health outcomes. Suggestions for future research are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart thermostat data-driven U.S. residential occupancy schedules and development of a U.S. residential occupancy schedule simulator

Occupancy schedule is one of the key inputs in Building Energy Modeling (BEM) to reflect the interaction between buildings and occupants. Over the past decades, standardized occupancy schedules, developed mainly by engineering rule-of-thumb, have been widely used in BEM due to its simplicity and lack of real measured occupancy data. However, the BEM community has recognized their association with uncertainty and reliability in simulation results from BEM. This study introduces representative occupancy schedules in the U.S. residential buildings, derived from a large smart thermostat dataset and time-series K-means clustering, and an open-source tool to generate a stochastic residential occupancy schedule. Over 90,000 residential occupancy schedules were estimated from the ecobee Donate Your Data dataset. Then, the representative occupancy schedules were identified through clustering. This study further investigated the impacts of three parameters (day, house type, and state) on residential occupancy schedules. Then, a tool, the Residential Occupancy Schedule Simulator (ROSS), is developed using the representative occupancy schedules derived in this study. Details of this tool are presented in this paper. In conclusion, the derived representative occupancy schedules and the ROSS tool can help improve the energy modeling of residential buildings.

42 ENGINEERING↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Enhanced flexibility and thermal conductivity of HfC decorated carbon nanofiber mats

Future-generation spacecraft components allude discovery of novel materials that can withstand extreme environments (>2000 °C). The combined effect of ultra-high temperature ceramics (UHTCs) and carbon fibers (C f ) can satisfy the demanding requirements of aerospace applications. A novel, hybrid, and flexible hafnium carbide (HfC)-decorated carbon nanofiber (C nf ) mat was fabricated via electrospinning. Enhanced thermal stability of the flexible HfC decorated C nf over C nf can be elucidated from the 20-fold increment in thermal conductivity and the onset of degradation at higher temperatures (840 °C). Successful integration of multi-layered sandwich lattice using in-housed fabricated HfC decorated C nf showed retention of the fibrous structure even after extreme spark plasma sintering (SPS) process at 1850 °C. Fabricating a similar multi-layered structure using procured C f was unsuccessful due to bundled agglomeration and micron-sized fibers. High-load indentation suggests that HfC decorated C nf interlayer is stronger (~2.3 times) than the parent UHTC with no cracking at the interface. Compared with the HfC matrix, the indentation-damaged area at the interface reduced up to ~56% due to toughening mechanisms such as C nf , fiber pull-out and bridging. The synthesized HfC decorated Cnf mat is proposed as an ultra-thin filler material for joining similar or dissimilar UHTCs while maintaining similar chemistry and better mechanical integrity at the interface. Furthermore, the findings insinuate a new paradigm in designing hybrid and flexible ceramic-containing materials for thermal protection systems (TPS) of future-generation spacecraft components that can mitigate failure in extreme environments (>2000 °C).

36 MATERIALS SCIENCE↗

Metal leaching from Lithium-ion and Nickel-metal hydride batteries and photovoltaic modules in simulated landfill leachates and municipal solid waste materials

Photovoltaic (PV) modules and batteries can either be recycled or disposed of in landfills at end-of-life (EoL). This work focuses on disposal since the benefit of recycling PV modules and batteries is well established. This study characterizes the potential toxicity due to metals leaching from selected PV modules and batteries through both the Toxicity Characteristic Leaching Procedure (TCLP) and in-house batch leaching protocols to probe the impact on metallic ion mobility as a function of the different types of e-waste entering the waste stream, the magnitude of device damage when placed into the waste stream, and the simulated municipal solid waste (SMSW) composition. Our results showed that one PV module and three battery types in this study should be classified as hazardous waste within the U.S. However, for some of the other e-wastes, metals of concern including Cr, Cu, Hg, Ni, Pb, and Zn leached during the batch tests but not in the TCLP regulatory method. For most of the waste types, the amounts of metals that leached in the TCLP test and batch tests were much lower than the total extractable amounts, demonstrating the potential for additional unaccounted for amounts of metals to leach. Our results demonstrate that the TCLP regulatory method might fail at predicting potential leaching and at capturing the complexity of e-waste leaching in landfill conditions. It confirms that additional work is needed urgently to develop appropriate EoL procedures for MSW with PV and battery e-waste.

42 ENGINEERING↗

Meso-scale modelling of compressive fracture in concrete with irregularly shaped aggregates

This paper presents a meso-scale modelling framework to investigate the fracture process in concrete subjected to uniaxial and biaxial compression accounting for its mesostructural characteristics. 3D mesostructure of concrete consisting of coarse aggregates, mortar and interfacial transition zone between them was developed using an in-house code based on the Voronoi tessellation and splining method, which enables to generate the realistic-look aggregates with controllable structural features such as content, location, size and shape. Based on the generated 3D mesostructure, the concrete damage plasticity approach was employed to simulate the compressive fracture behaviour of concrete in terms of crack morphology and stress-strain response against the shape parameters of aggregate. Results indicate that the shape of aggregate has a negligible effect on compressive strength of concrete, which is highly associated with the random location and size distribution of aggregate. The aggregate irregularity has a significant influence on crack initiation and growth of concrete.

36 MATERIALS SCIENCE↗