High Cooperativity Using a Confocal-Cavity–QED Microscope

Cavity quantum electrodynamics (QED) with cooperativity far greater than unity enables high-fidelity quantum sensing and information processing. The high-cooperativity regime is often reached through the use of short single-mode resonators. More complicated multimode resonators, such as the near-confocal optical Fabry-Pérot cavity, can provide intracavity atomic imaging in addition to high cooperativity. This capability has recently proved important for exploring quantum many-body physics in the driven-dissipative setting. In this work, we show that a confocal-cavity–QED microscope can realize cooperativity in excess of 110. This cooperativity is on par with the very best single-mode cavities (which are far shorter) and 21 times greater than single-mode resonators of similar length and mirror radii. The 1.7-µm imaging resolution is naturally identical to the photon-mediated interaction range. We measure these quantities by determining the threshold of cavity superradiance when small optically tweezed BoseEinstein condensates are pumped at various intracavity locations. Transmission measurements of an ex situ cavity corroborate these results. We provide a theoretical description that shows how cooperativity enhancement arises from the dispersive coupling to the atoms of many near-degenerate modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-mass vector-meson production at forward rapidity in 𝑝 + 𝑝 and Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV

The PHENIX experiment at the Relativistic Heavy Ion Collider has measured low-mass vector-meson (𝜔+𝜌 and 𝜙) production through the dimuon decay channel at forward rapidity (1.2 < |y| < 2.2) in 𝑝 + 𝑝 and Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV. The low-mass vector-meson yield and nuclear-modification factor were measured as a function of the average number of participating nucleons, ⟨𝑁 part ⟩, and the transverse momentum 𝑝 𝑇 . These results were compared with those obtained via the kaon decay channel in a similar 𝑝 𝑇 range at midrapidity. The nuclear-modification factors in both rapidity regions are consistent within the uncertainties. A comparison of the 𝜔 + 𝜌 and 𝐽/𝜓 mesons reveals that the light and heavy flavors are consistently suppressed across both 𝑝 𝑇 and ⟨𝑁 part ⟩. Finally, in contrast, the 𝜙 meson displays a nuclear-modification factor consistent with unity, suggesting strangeness enhancement in the medium formed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal nature of confining strings

We investigate the quantum statistical properties of the confining string connecting a static fermion-antifermion pair in the massive Schwinger model. By analyzing the reduced density matrix of the subsystem located in between the fermion and antifermion, we demonstrate that as the interfermion separation approaches the string-breaking distance, the overlap between the microscopic density matrix and an effective thermal density matrix exhibits a pronounced, narrow peak, approaching unity at the onset of string breaking. This behavior reveals that the confining flux tube evolves toward a genuinely thermal state as the separation between the charges grows, even in the absence of an external heat bath. In other words, one cannot tell whether a reduced state of the subsystem arises from a surrounding heat bath or from entanglement with the rest of the system. The entanglement spectrum near the critical string-breaking distance exhibits a rapid transition from the dominance of a single state describing the confining electric string towards a strongly entangled state containing virtual fermion-antifermion pairs. Our findings establish a quantitative link between confinement, entanglement, and emergent thermality, and suggest that string breaking corresponds to a microscopic thermalization transition within the flux tube.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parametric coincidence in the baryon to dark matter ratio from Affleck-Dine baryogenesis and UV freeze-in dark matter

We highlight that the observed concurrence between the baryon and dark matter relic densities can be explained via a parametric coincidence between two distinct production mechanisms: Affleck-Dine baryogenesis and dark matter UV freeze-in. In the Affleck-Dine mechanism, the baryon asymmetry is naturally proportional to the inflationary reheating temperature 𝑇 rh , which also plays a critical role in setting the relic abundance of UV freeze-in dark matter. Since Affleck-Dine baryogenesis requires flat directions in the potential, the framework is inherently supersymmetric, offering compelling UV freeze-in dark matter candidates such as the gravitino. We outline scenarios in which 𝑇 rh simultaneously determines both relic abundances, resulting in a baryon-to-dark matter ratio of order unity that is largely insensitive to 𝑇 rh . We also discuss the conditions required to avoid Q-ball formation or dark matter production by other mechanisms, such as next-to-lightest supersymmetric particle decays, to preserve the parametric coincidence between baryon and dark matter abundances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observing dark matter decays to gravitons via graviton-photon conversion

Since dark matter is only known to have gravitational interactions, it may plausibly decay to gravitons on cosmological timescales. Although such a scenario can be easily realized, there are currently no known limits on this possibility based on indirect-detection methods. We propose a new search strategy that exploits the Gertsenshtein effect, whereby the gravitons produced in dark matter decays can convert to photons in large-scale magnetic fields along the line of sight to an observer. These conversions primarily occur within cosmological filaments which occupy a large (order unity) volume fraction and contain ∼ 10 – 100 nG fields with ∼ Mpc coherence lengths. Thus, dark matter decays to gravitons predict an irreducible population of extragalactic photons, which we constrain using the extragalactic gamma-ray background measured by the Fermi-LAT telescope. Using this method, we derive the first-ever constraints on the dark matter lifetime in the 0.1 GeV - 10 8 GeV mass range, contingent on the assumed filament magnetic field strength. We also make projections for the Advanced Particle-astrophysics Telescope, which can improve sensitivity to this dark matter decay channel by an order of magnitude beyond those we set using Fermi-LAT data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolving pseudosymmetry in γ-TiAl using cross-correlation electron backscatter diffraction with dynamically simulated reference patterns

Pseudosymmetry is a phenomenon that occurs when grains with different lattice parameters produce nearly identical diffraction patterns such that conventional electron backscatter diffraction (EBSD) techniques are unable to unambiguously differentiate the lattice orientations. This commonly occurs in materials with near-unity tetragonality, such as γ-TiAl. The current study uses cross-correlation EBSD to resolve pseudosymmetry in γ-TiAl. Three dynamically simulated reference patterns are generated for each point in the scan, one for each of the three potential pseudosymmetric orientations, which are subsequently correlated with the original pattern using six different methods in order to identify the correct orientation. The methods are first applied to a scan of dynamically simulated patterns, which is used to evaluate the sensitivity of the method to pattern resolution, pattern noise and pattern center error. It was determined that all six methods were 100% successful up to about 13 µm of pattern center error and pattern resolutions of about 80 × 80 pixels, and hence the methods were applied to an experimental sample of lamellar γ-TiAl. A hybrid combination of two of the methods was shown to successfully select the correct pseudosymmetry for about 96% of the points in the scan, improving upon the 70% accuracy of the Hough-based methods for the current study and 90% accuracy for previous studies resolving pseudosymmetry in lamellar γ-TiAl.

36 MATERIALS SCIENCE↗

A Novel AC to AC Wireless Power Transfer System for EV Charging Applications

In this paper, a novel ac to ac wireless power transfer (WPT) system is introduced for electric vehicle (EV) charging applications to reduce cost and design complexity. The presented wireless power transfer concept achieves unity power factor (UPF) on the grid-side by using a hybrid frequency ac / ac converter without an additional converter stage and closed loop control compared to the conventional systems. Due to inherent merit of the proposed ac / ac converter, ac input with 60 Hz grid frequency can be directly transferred to the load by superimposing with high frequency switching signal through the wireless coils. To validate the theoretical analysis of the proposed WPT system, the experimental results of the proposed converter are provided for 650 W output power by using 6 inches air gap between the couplers with the input of 110 VRMS ac source. The system overall efficiency is measured 89 % achieving 0.99 power factor (PF) and 1.5 % current total harmonic distortion (THD).

Asa, Erdem↗

A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic in Dual-Active-Bridge Converters

The Dual-Active-Bridge (DAB) converter transformer flux unbalance, or dc bias, could be a critical issue due to the mismatches of converter circuit parameters and control transients. In this paper, a steady-state flux balancing scheme, based on the second-order harmonic of magnetizing current has been proposed. The relationship between steady-state flux/magnetizing current unbalance and its harmonic contents has been analyzed, with which a new current sensing method and control strategy are introduced. The proposed magnetizing current sensing method can be implemented for both unity and complicated fractional turns ratios, without high sensitivity to dc offset from the analog circuitry. The proposed scheme has been validated with experimental results on 850-V/850-V DAB converters within a system, as well as in an 850-V/6700-V medium voltage DAB unit.

Gao, Zihan↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

Optimal Modulation and DM Filter Design for a High Switching Frequency Single-Stage Microinverter

This paper presents an optimal modulation and systematic filter design approach for a single-stage dual-active-bridge (DAB) based dc-ac microinverter to achieve improved differential-mode (DM) noise performance for electromagnetic interference (EMI) tests. As DM filters contribute significantly to the overall converter volume, the main objective of this work is to leverage the degrees of freedom in the DAB converters to effectively attenuate the EMI noise. In addition, the DM filter design method needs to ensure near unity power factor converter operation. To achieve these targets, this paper analyzes three modulation strategies based on fixed or variable switching frequency operation where the different control modulation variables are varied to find the simulated DM noise spectrum. Based on the required DM attenuation, a constrained optimization problem is formulated to determine minimal DM filter parameters. Simulation results show that a spread spectrum approach with variable switching frequency is shown to minimize the DM EMI attenuation effort by spreading the noise profile. A fully GaN 400 W hardware prototype demonstrated the spread-sprectrum approach.

14 SOLAR ENERGY↗

Skipper-CCD Output Sensitivity Improvement with a Common Source Cascode Amplifier

A Skipper-CCD output has been traditionally readout in a source follower configuration, also known as common drain, mainly because in this configuration a good compromise between sensitivity, noise and speed is achieved. In this work a different approach is presented: the output transistor is connected in a common source configuration and an external cascode device is added in series, obtaining a voltage gain higher than unity without increasing significantly the parasitic capacitance due to Miller effect and thus increasing the obtained voltage per electron of charge. The proposed output stage improves the sensitivity 3.4 times when compared with the traditionally used stage while keeping almost the same equivalent noise charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and Control of a Back to Back Modular Multilevel Converter System for Grid Forming Application with Advanced Grid Support Functionalities

The main focus of this paper is to investigate the possibility of using modular multilevel converter based back-to-back system for grid forming applications. A decentralized hierarchical control architecture with a modified local controller based on nonlinear techniques for grid forming application have been investigated. Grid functionalities based on IEEE 1547-2018 for grid forming converters have been utilized. The local controllers ensure distortion free balanced sinusoidal output voltage on the grid forming side with unbalanced or nonlinear loading condition. The grid following side ensures unity power factor currents under unbalanced grid voltage condition. The dc bus voltage control ensures oscillation free voltage under balanced conditions and control of the average voltage under unbalanced condition. Efficacy of the overall system is verified by modeling the system in MATLAB/Simulink and PLECS domain and the most important case studies are presented.

advanced grid support functionalities↗

Secondary Active Rectifier Control Scheme for a Wireless Power Transfer System with Double-Sided LCC Compensation Topology

This paper proposes a secondary control method using an active rectifier for a double-sided LCC tuned wireless power transfer system (WPT) to reduce the communication requirements of the system. As the active rectifier regulates the output power with a constant primary coil current, the secondary circulating time interval is adjusted while maintaining a unity power factor. First, circuit modelling and sensitivity analyses for the voltage gain, input impedance, coil current rating and power transfer are investigated with a design example of 20kW WPT. Subsequently, the control scheme is developed by considering the four operation modes with the phase difference as the control variable. To prove the effectiveness of the proposed control method, a simulation model is built, and the results demonstrate good dynamic performance with high accuracy for voltage regulation. Compared with the conventional secondary control, it improves the performance of the system along with a well-developed converter gain by maintaining the equivalent load resistive and reduced circulating time intervals, which further improves the system efficiency. The proposed system also eliminates the need for an additional de/de converter on the secondary side.

Zou, Shenli↗

Power Converter Topologies for Electrolyzer Applications to Enable Electric Grid Services

Hydrogen electrolyzers, with their operational flexibility, can be configured as smart dynamic loads which can provide grid services and facilitate the integration of more renewable energy sources into the electrical grid. However, to enable this ability, the electrolyzer system should be able to control both active and reactive power in coordination with the low-level controller of the electrolyzer via the power electronics system interface between the utility grid and electrolyzer. This paper discusses power converter topologies and the control scheme of this power electronics interface for electrolyzer applications to enable electricity grid services. For the sake of unity, in this paper, we consider the power converter system interfacing the utility grid at the line-to-line root mean square (RMS) value of 480 VAC-60 Hz and supplying to the 3500 A-750 kW PEM electrolyzer stack.

electrolyzer↗

A Novel Three Phase Oak Ridge DC / AC Converter for Wireless Grid Tied Applications

In this study, a novel three phase oak ridge dc to ac converter is introduced for wireless mobility energy storage (WMES) applications to support the grid demand during peak times. The proposed topology can be used in a bi-directional operation between ac grid and dc terminals of energy storage by accomplishing unity power factor. Inherent merit of the technology can directly merge dc input to the high frequency and 60 Hz grid frequency by superimposing through the wireless coils. Theoretical and simulation results are validated by the simulation analysis for 20 kW output power. The functionality of the proposed three phase system is established by using 6 inches air gap between the couplers with the input of 675 V DC and output of 277 V AC, RMS . The system overall design analysis is demonstrated for simulation analysis and simulation results are presented achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load 20 kW wireless power transfer.

Asa, Erdem↗

Uniform Mechanical Loading Can Test for Nonuniform Loading Durability

In this work, we present a method to evaluate the equivalency between any module mechanical loading conditions. The method is developed to address the specific failure mode of glass fracture and is based on Weibull analysis and weakest link theory. It considers the varying stress profile across the module to calculate the probability of glass fracture, which is used as the metric of equivalency. An idealized nonuniform loading scheme is employed to demonstrate the method and introduce the concept of the equivalent uniform load factor: a factor applied to the maximum pressure of the nonuniform load to obtain the equivalent uniform load value. It is demonstrated that this factor is less than unity for all nonuniform load cases considered, including snow and various characters of wind loading. These significant results suggest that uniform loading may be reliably, and practically, employed to evaluate photovoltaic module glass for nonuniform loading durability.

14 SOLAR ENERGY↗

Inverter Reliability Estimation for Advanced Inverter Functionality

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous modes, which will produce new stresses on the grid-interfacing power electronics components, such as DC/AC inverters. In previous work, multiple DER devices were instrumented to evaluate additional component stress under multiple reactive power setpoints. We utilize quasi-static time-series simulations to determine voltage-reactive power mode (volt-var) mission profile of inverters in an active power system. Mission profiles and loss estimates are then combined to estimate the reduction of the useful life of inverters from different reactive power profiles. It was found that the average lifetime reduction was approximately 0.15% for an inverter between standard unity power factor operation and the IEEE 1547 default volt-var curve based on thermal damage due to switching in the power transistors. For an inverter with an expected 20-year lifetime, the 1547 volt-var curve would reduce the expected life of the device by 12 days. This framework for determining an inverter's useful life from experimental and modeling data can be applied to any failure mechanism and advanced inverter operation.

component degradation↗

Microinhomogeneities in Semi-Insulating Cd(Zn)Te

Here, we investigated the temperature dependences (TDs) in the range of 290-423 K for the Hall constant R H and the Hall carrier mobility μn (σ R H ) in semi-insulating Cd 0.9 Zn 0.1 Te:In (CZT) crystals. As-grown, CZT material has nonequilibrium distributions of native and impurity-related defects. Thus, before taking any measurements, the samples were kept inside the test chamber in the dark at 423 K to reach an equilibrium state at T <; 423 K. For all the tested samples, the R H TD could be described by two activation energies. At the transitional point, the TD of the carrier mobility also changes from “normal” at high temperatures to “exponential” at low temperatures. The latter is a result of the collective effect of drift barriers due to microinhomogeneity. Therefore, only the high-temperature activation energies can be assigned to the ionization energies of the compensated deep donors (ε D ). For different samples, the values for ε D 0 (at absolute zero) were found to be in the range of 0.50-0.78 eV, and the degree of donor compensation [D + ]/[D] is between 0.3 and 0.98. The low-temperature region, where there are strong effects of crystal microinhomogeneities, cannot be used to characterize the ionization energy of donors. Therefore, we describe the activation energy as ε 1 = ε D - αε b , where ε b is the drift barrier height found from the TD of the carrier mobility and α takes a value close to unity. Values of ε b for our studied samples lie within (0.05-0.35) eV.

36 MATERIALS SCIENCE↗