Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Computer-aided Veress needle guidance using endoscopic optical coherence tomography and convolutional neural networks

During laparoscopic surgery, the Veress needle is commonly used in pneumoperitoneum establishment. Precise placement of the Veress needle is still a challenge for the surgeon. In this study, a computer-aided endoscopic optical coherence tomography (OCT) system was developed to effectively and safely guide Veress needle insertion. This endoscopic system was tested by imaging subcutaneous fat, muscle, abdominal space, and the small intestine from swine samples to simulate the surgical process, including the situation with small intestine injury. Each tissue layer was visualized in OCT images with unique features and subsequently used to develop a system for automatic localization of the Veress needle tip by identifying tissue layers (or spaces) and estimating the needle-to-tissue distance. We used convolutional neural networks (CNNs) in automatic tissue classification and distance estimation. In conclusion, the average testing accuracy in tissue classification was 98.53 ± 0.39%, and the average testing relative error in distance estimation reached 4.42 ± 0.56% (36.09 ± 4.92 μm).

59 BASIC BIOLOGICAL SCIENCES↗

Biaxial Braided Flared Cone Structural Analysis

Computed Tomography (CT) is a useful tool for performing structural analysis on polymer based materials due to its high precision and accuracy. CT data was taken of two flared cones made from carbon fiber and fiberglass. One of the flared cones is pictured below. The variation in braid angle throughout the part was measured using Avizo 3D modelling software while the variation in thickness throughout the part was determined using MATLAB. Samples of pictures from the process of each of these analyses are shown below. The overall goal of this analysis was to collect structural data relevant to future testing of the parts.

Computed Tomography↗

3D analysis of TRISO fuel compacts via X-ray computed tomography

In this study, low-enriched uranium oxycarbide (LEUCO) and surrogate tristructural isotropic (TRISO)- coated-particle compacts with particle volumetric packing fractions of 25%, 40%, and 48% were imaged utilizing X-ray-computed tomography. Subsequent 3D image analysis identified and further quantified kernel size, sphericity, and observed porosity. In addition, the spatial distribution, coordination number, and kernel-nearest neighbors were analyzed and compared for the different packing fractions. Metrics such as observed porosity and sphericity enabled quantification and screening for abnormal kernels within TRISO compacts. Assessment of TRISO particle location confirmed and further quantified a non-uniform distribution of TRISO particles with the spatial distribution in the radial direction being roughly described as a dampened sinusoidal function. The amplitude and frequency of this non-uniform distribution increased with increasing packing fraction. Measured kernel-nearest neighbor distances indicated two regions along the radial surfaces of compacts where TRISO particles are more likely to be in intimate contact with one another. These regions were found: (1) at upper and lower faces of compacts (i.e., corners); (2) offset ~10% of a compact's length from the axial center near the exterior surface. Within these regions, small quantities of defective TRISO surrogate particles (48% packing fraction) and defective LEUCO TRISO particles (40% packing fraction) were found. No defective particles were found within 25% packing fraction LEUCO TRISO compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Additively manufactured Al-Ce-Ni-Mn alloy with improved elevated-temperature fatigue resistance

Here, the high cycle fatigue behavior of an additively manufactured (AM) Al-10.5Ce-3.1Ni-1.2Mn wt% alloy was evaluated at 350 °C. The measured fatigue strength of 50 MPa at this temperature is comparable to the most fatigue resistant wrought Al alloys (2618-T6 and 7079-T6) at 315 °C. Refinement of pore populations through advanced AM processing in the examined alloy led to oxide inclusions becoming dominant fatigue crack initiation sites. The distribution of microstructural features that determine crack initiation was measured by X-ray computed tomography and served as input to make fatigue strength model predictions with various methodologies. A Monte-Carlo based approach that was previously applied to predict the fatigue strength of cast aluminum alloys through pore size distributions yielded accurate predictions for the fatigue strength of this AM alloy. Given the tunability of defect distributions in AM alloys, the sensitivity of the Al-Ce-Ni-Mn alloy fatigue behavior to defect distributions and outstanding elevated-temperature fatigue resistance of this alloy; the results together suggest the possibility of a new generation of fatigue-resistant alloys produced by the additive manufacturing route.

36 MATERIALS SCIENCE↗

Effect of impurities on phase transformation and precipitation in a low-carbon steel

Impurity elements have been added to a commercial low carbon steel grade to simulate the levels that could arise as a result of increased scrap recycling during steel production. In this study, continuous cooling transformation (CCT) diagrams were constructed for the steels with varying levels of impurities, and it is shown that impurities suppress the phase transformation across a wide range of cooling rates. It was found that a step was formed in the start temperature curve, separating the reconstructive and displacive transformations. The influence of impurities on both the reconstructive transformation and displacive transformation are discussed. Additionally, Cu precipitates were observed using scanning transmission electron microscopy (STEM) in the highest impurity-containing steel after slow cooling (0.05°C/s), fast cooling (5°C/s) and interrupted cooling. It was found that the precipitation kinetics is in the following order: cementite within the secondary phase and cementite at secondary phase-ferrite interface> ferrite grain boundaries> ferrite grain matrix. Atom-probe tomography (APT) revealed Cu precipitates formed on the surface of cementite lamellae, but not within it. This work offers insights for the phase transformation control and precipitation regulation during the thermomechanical processing of low carbon steels containing impurity elements due to scrap recycling.

36 MATERIALS SCIENCE↗

Thermal Inspection of Composite Honeycomb Structures

Composite honeycomb structures continue to be widely used in aerospace applications due to their low weight and high strength advantages. Developing nondestructive evaluation (NDE) inspection methods are essential for their safe performance. Pulsed thermography is a commonly used technique for composite honeycomb structure inspections due to its large area and rapid inspection capability. Pulsed thermography is shown to be sensitive for detection of face sheet impact damage and face sheet to core disbond. Data processing techniques, using principal component analysis to improve the defect contrast, are presented. In addition, limitations to the thermal detection of the core are investigated. Other NDE techniques, such as computed tomography X-ray and ultrasound, are used for comparison to the thermography results.

Zalameda, Joseph N.↗

Fabrication and Characterization of A Lunar Simulant-Based Sintered Construction Material

In-situ resource utilization (ISRU) is critical to enable future efforts to have a long-term human presence on the Moon as well as Mars. ISRU technologies are being developed for radiation protection, dust mitigation, thermal insulation, and other applications. One such ISRU technology for creating construction materials out of lunar and Martian regolith is sintering, which is a thermal-based construction process that bonds finely grained material together at temperatures below the melting point. However, the conditions employed during the sintering, such as temperature, atmospheric composition, duration of the process, and pressure, can have a significant impact on the quality and strength of the resulting materials. In parallel, the development of methods for characterizing the quality, porosity, density, and other properties of these materials is critical. X-ray computed tomography (X-ray CT) can image large changes in density within a material, such as the presence of pores throughout an otherwise uniform medium, with relatively high spatial resolution. Similarly, Terahertz time-domain spectroscopic (THz-TDS) imaging is sensitive to density variations within samples, but is restricted to non-conducting materials. Specifically, previous work has shown that the refractive index (n eff ) values obtained through the analysis of THz-TDS images increases with increasing density within plastic samples. Even further, this work showed that it is possible to create a calibration curve for a given material from samples of different, but known density, which can enable one to directly convert n eff to density for samples having the same composition, but unknown density. Here, we report on the fabrication of a lunar simulant-based sintered construction material using vacuum hot pressed (VHP) sintering, then show X-ray CT and THz-TDS imaging results of the sample, which show spatial variations in the material. This has important implications for efforts to improve these types of lunar construction material processes and verify the quality of these materials in terms of consolidation. To the best of our knowledge, there is no previous work utilizing VHP sintering to make lunar simulant-based construction materials or exploring the feasibility of THz imaging to spatially map the density variation through a lunar simulant-based construction material.

Terahertz time-domain spectroscopic imaging↗

Embedding of Optical Fibers with Electric Field Assisted Sintering

The Electric Field Assisted Sintering (EFAS) technique was used for embedding the fibers, involving rapid heating via an electric current and pressure, reducing fiber exposure to high temperatures. Stainless steel guide tubes were inserted at the fiber-matrix junctions to prevent fiber breakage during the sintering process. The study varied key EFAS parameters—temperature (800°C to 980°C), pressure (40-50 MPa), and hold time (5-10 minutes)—to assess how they influenced fiber embedding. After embedding, the fibers were inspected using optical frequency domain reflectometry (OFDR) to evaluate optical losses and strain along the fiber length. The OFDR scans confirmed that the fibers remained intact, and subsequent transmission tests demonstrated no macroscopic fractures. The embedded samples were also analyzed using scanning electron microscopy (SEM) and X-ray computed tomography (CT) scans. These tests confirmed good bonding between the fiber and matrix with no cracking, though some porosity was present in samples fabricated at lower temperatures. At higher temperatures (980°C), the fiber-matrix bonding was continuous and defect-free, with metal coatings aiding in the bonding process. Elemental analysis showed interdiffusion between the fiber coatings and matrix materials, particularly between the gold coating and stainless steel. Helium leak tests revealed that lower sintering temperatures resulted in matrix porosity, causing leaks, but samples fabricated at 980°C were leak-tight.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimating biofuel contaminant concentration from 4D ERT with mixing models

Here, we present the results of a lab-scaled feasibility study to assess the performance of electrical resistivity tomography for detection, characterization, and monitoring of fuel grade ethanol releases to the subsurface. Further, we attempt to determine the concentration distribution of the ethanol from the electrical resistivity tomography data using mixing-models. Ethanol is a renewable fuel source as well as an oxygenate fuel additive currently used to replace the known carcinogen methyl tert-butyl ether; however, ethanol is preferentially biodegraded and a cosolvent. When introduced to areas previously impacted by nonethanol-based fuels, it will facilitate the persistence of carcinogenic fuel compounds like benzene and ethylbenzene, as well as remobilize them to the ground water. These compounds would otherwise be retained in the soil column undergoing active or passive remediation processes such as soil vapor extraction or natural attenuation. Here, we introduce ethanol to a saturated Ottawa sand in a tank instrumented for four-dimensional geoelectrical measurements. Forward model results suggest pure phase ethanol released into a water saturated silica sand should present a detectable target for electrical resistivity tomography relative to a saturated silica sand only. We observe the introduction of ethanol to the closed hydraulic system and subsequent migration over the duration of the experiment. One-dimensional and three–dimensional temporal data are assessed for the detection, characterization, and monitoring of the ethanol release. Results suggest one-dimensional geoelectrical measurements may be useful for monitoring a release, while three-dimensional geoelectrical field imaging would be useful to characterize, monitor, and design effective remediation approaches for an ethanol release, assuming field conditions do not preclude the application of geoelectrical methods. We then attempt to use predictive mixing models to calculate the distribution of ethanol concentration within the measurement domain. For this study we examine four different models: a nested parallel mixing model, a nested cubic mixing model, the complex refractive index model (CRIM), and the Lichtenecker-Rother (L-R) model. The L-R model, modified to include an electrical formation factor geometry term, provided the best agreement with expected EtOH concentrations.

09 BIOMASS FUELS↗

EGS Collab Experiment 2: Shear Stimulation ERT Monitoring Data

This repository contains the electrical resistivity tomography (ERT) monitoring data that was collected before, during, and after shear stimulation attempts were conducted at EGS Collab. These tests were carried out on the SURF 4100 level during Experiment 2 in March, 2022. Flow and stimulation data corresponding to this dataset are available in a different GDR dataset, which is linked below. Also included here are the E4D input files that were used to process the ERT data. E4D is an open source ERT monitoring and inversion code which is linked for use below.

15 GEOTHERMAL ENERGY↗

Multimodal Defect Imaging of Pure Tungsten Components Fabricated via Electron Beam Powder Bed Fusion

The utilization of additive manufacturing (AM) techniques for refractory materials in high-temperature environments has significantly expanded because of the ability to fabricate geometrically complex components. Electron beam powder bed fusion (EB-PBF), which provides lower residual stress, a cleaner vacuum environment, and better efficiency for high melting point, is one of the best-suited AM methods to produce advanced refractory components. However, the property variation attributed to the heterogeneous microstructure and process-induced defects has hindered the widespread adoption of EB-PBF-produced material like tungsten. While numerous in-situ monitoring and defect detection methods have been demonstrated for EB-PBF, a workflow that compares and evaluates process-induced abnormalities from different imaging perspectives is still limited. This study examines a feature-embedded tungsten component manufactured via the EB-PBF process to demonstrate the defect detection capabilities of a multimodal defect imaging workflow. The predefined and process-induced defects are evaluated by harnessing various imaging techniques, including in-situ electron imaging, layerwise near-infrared (NIR) imaging, post-build high-energy x-ray computed tomography (CT), and conventional destructive metallography. The results highlight the strengths and limitations of distinctive defect imaging techniques concerning specific defect types, sizes, and conditions. It was found that electron imaging can provide more abnormal detection capabilities while maintaining a higher measuring accuracy, against the conventional metallography in this case study, compared with NIR and CT imaging techniques.

36 MATERIALS SCIENCE↗

Ultrasparse View X-ray Computed Tomography for 4D Imaging

X-ray computed tomography (CT) is a noninvasive, nondestructive approach to imaging materials, material systems, and engineered components in two and three dimensions. Acquisition of three-dimensional (3D) images requires the collection of hundreds or thousands of through-thickness X-ray radiographic images from different angles. Such 3D data acquisition strategies commonly involve suboptimal temporal sampling for in situ and operando studies (4D imaging). Herein, we introduce a sparse-view imaging approach, Tomo-NeRF, which is capable of reconstructing high-fidelity 3D images from <10 twodimensional radiographic images. Experimental 2D and 3D X-ray images were used to test the reconstruction capability in two-view, four-view, and six-view scenarios. Tomo-NeRF is capable of reconstructing 3D images with a structural similarity of 0.9971–0.9975 and a voxel-wise accuracy of 81.83–89.59% from 2D experimentally obtained images. Furthermore, the reconstruction accuracy for the experimentally obtained images is less than the synthetic structures. Experimentally obtained images demonstrate a similarity of 0.9973–0.9984 and a voxelwise accuracy of 84.31–95.77%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adorym: a multi-platform generic X-ray image reconstruction framework based on automatic differentiation

We describe and demonstrate an optimization-based X-ray image reconstruction framework called Adorym. Our framework provides a generic forward model, allowing one code framework to be used for a wide range of imaging methods ranging from near-field holography to fly-scan ptychographic tomography. By using automatic differentiation for optimization, Adorym has the flexibility to refine experimental parameters including probe positions, multiple hologram alignment, and object tilts. It is written with strong support for parallel processing, allowing large datasets to be processed on high-performance computing systems. We demonstrate its use on several experimental datasets to show improved image quality through parameter refinement.

36 MATERIALS SCIENCE↗

Nondestructive Evaluation (NDE) for Inspection of Composite Sandwich Structures

Composite honeycomb structures are widely used in aerospace applications due to their low weight and high strength advantages. Developing nondestructive evaluation (NDE) inspection methods are essential for their safe performance. Flash thermography is a commonly used technique for composite honeycomb structure inspections due to its large area and rapid inspection capability. Flash thermography is shown to be sensitive for detection of face sheet impact damage and face sheet to core disbond. Data processing techniques, using principal component analysis to improve the defect contrast, are discussed. Limitations to the thermal detection of the core are investigated. In addition to flash thermography, X-ray computed tomography is used. The aluminum honeycomb core provides excellent X-ray contrast compared to the composite face sheet. The X-ray CT technique was used to detect impact damage, core crushing, and skin to core disbonds. Additionally, the X-ray CT technique is used to validate the thermography results.

Zalameda, Joseph N.↗

Using X-Ray Computed Tomography to Image Apollo Drive Tube 73002

The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the Moon. Although most Apollo samples are well characterized, several types of samples remain wholly or largely unstudied since their return: unopened and/or sealed drive tube samples, samples frozen upon return, and samples stored in a He-purged environment. NASA selected nine teams to participate in the Apollo Next Generation Sample Analysis (ANGSA) Program to study representative samples from each of these categories. The first sample studied as part of the ANGSA program is drive tube 73002, a 4 cm diameter unopened (but unsealed) drive tube collected on a landslide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube, and the bottom half of the tube (73001)was sealed under vacuum on the Moon (and will be studied next). As part of the preliminary examination of sample 73002, the entire drive tube was imaged with a high resolution X-ray Computed Tomography (XCT) scan prior to opening and dissecting the sample. Additionally, >50 XCT scans have been made of “large” clasts (>4 mm) removed from the core as part of the ongoing dissection process. Here we will present both the whole drive tube XCT data showing the overall structure of sample 73002 prior to dissection, as well as XCT scans of individual clasts that reveal the types and abundance of different lithologies present within the drive tube. We will also discuss the utility of the scans as part of the curation and preliminary examination process, as well as the potential for future science returns from the XCT scans.

Ryan A Zeigler↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

Using X-Ray Computed Tomography as a Tool for Preliminary Examination Tool of Current and Future Extraterrestrial Sample Return Missions

The Astromaterials Acquisition and Curation Office at the Johnson Space Center is the past, present, and future home of all of NASA’s astromaterials sample collections. The primary goals of the curation office are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future. To this end, we perform fundamental research in advanced curation initiatives to better prepared for future sample return missions. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new sample collections, or getting new results from existing sample collections. As part of these advanced curation efforts, we have installed and are operating a Nikon XTH 320 X-ray Computed Tomography(XCT) system in the JSC curation office with four interchangeable X-ray sources, a large-area detector, and a heavy-duty stage. These instrument characteristics allow us exceptional flexibility to analyze a wide range of sample sizes, from sub-mm soil particles to rocks >10 cm in diameter. The penetrative nature of the XCT scans allows for astromaterials samples to be analyzed within sealed low-density containers (e.g., Teflon bags), preserving the pristinity of the samples. We have begun scanning of the Apollo and Antarctic Meteorite sample suites in order to non-destructively map out lithic clasts (and other features) within the samples. The data from these scans will be made available to scientists via the JSC curation website and the Astromaterials Curation Newsletter. We anticipate sample requests from these “new” lithic clasts identified in these “old” samples. We also anticipate that XCT analyses like these would be useful for future sample return missions, like the OSIRIS REx mission, as well as future sample return missions.

Zeigler, Ryan↗