Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Surface knowledge and risks to landing and roving - The scale problem

The role of surface information in the performance of surface exploration missions is discussed. Accurate surface models based on direct measurements or inference are considered to be an important component in mission risk management. These models can be obtained using high resolution orbital photography or a combination of laser profiling, thermal inertia measurements, and/or radar. It is concluded that strategies for Martian exploration should use high confidence models to achieve maximum performance and low risk.

Bourke, Roger D.↗

Planar Doppler Velocimetry for Large-Scale Wind Tunnel Testing

Recently, Planar Doppler Velocimetry (PDV) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike other optical means of measuring flow velocities, PDV is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDV have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDV in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDV capabilities for applications in large-scale wind tunnels that are intended primarily for the production testing of subsonic aircraft. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes and separations. To accomplish the objectives indicated, the PDV measurement process is first modeled and its performance evaluated computationally. The noise sources considered include those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with coherent illumination from pulsed lasers. The signal noise estimates are incorporated into the PDV signal analysis process and combined with computed scattering signals using a Mie scattering theory for polydisperse smoke particles. The relevant parameters incorporate a range of practical aerodynamic test conditions and facility sizes. The results define the optimum instrument configurations, show that the expected signal levels from a practical PDV system are sufficiently large to allow its useful application in large facilities, and show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing. Experimental studies using several experimental bench-top setups are then described that validate the physics of the PDV model and to calibrate its computed results. The validated model allows estimates of the uncertainties of PDV measurements and a complete definition of the PDV capabilities to be made with sufficient confidence to decide the viability of PDV for large-scale wind tunnel applications.

McKenzie, Robert L.↗

The Burst and Transient Source Experiment(BATSE)Earth Occultation Catalog of Low-Energy Gamma-Ray Sources. Short title: BATSE Earth Occultation Catalog v2.0

The Burst and Transient Source Experiment (BATSE), aboard the Compton Gamma Ray Observatory (CGRO), provided a record of the low-energy gamma-ray sky (approx. 20-1000 keV) between 1991 April and 2000 May (9.1y). BATSE monitored the high energy sky using the Earth occultation technique (EOT) for point sources whose emission extended for times on the order of the CGRO orbital period (approx. 92m) or greater. Using the EOT to extract flux - 2 - information, a catalog of sources using data from the BATSE large area detectors has been prepared. The first part of the catalog consists of results from the all-sky monitoring of 58 sources, mostly Galactic, with intrinsic variability on timescales of hours to years. For these sources, we have included tables of flux and spectral data, and outburst times for transients. Light curves (or flux histories) covering the entire nine mission are being placed on the world wide web. We then performed a deep-sampling of these 58 objects, plus a selection of 121 more objects, combining data from the entire 9.ly BATSE dataset. Source types considered were primarily accreting binaries, but a small number of representative active galaxies, X-ray-emitting stars, and supernova remnants were also included. The sample represents a compilation of sources monitored and/or discovered with BATSE and other high energy instruments between 1991 and 2000, known sources taken from the HEAO 1 A-4 (Levine et al. 1984) and Macomb and Gehrels (1999) catalogs. The deep sample results include definite detections of 82 objects and possible detections of 36 additional objects. The definite detections spanned three classes of sources: accreting black hole and neutron star binaries, active galaxies and supernova remnants. The average fluxes measured for the fourth class, the X-ray emitting stars, were below the confidence limit for definite detection. Flux data for the deep sample are presented in four energy bands: 20-40, 40-70, 70-160, and 160-430 keV. The limiting average flux level (9.1 y) for the sample varies from 3.5 to 20 mCrab (5delta) between 20 and 430 keV, depending on systematic error, which in turn is primarily dependent on the sky location. To strengthen the credibility of detection of weaker sources (approx.5-25 mCrab), we generated Earth occultation images, searched for periodic behavior using FFT and epoch folding methods, and critically evaluated the energy-dependent emission in the four flux bands. The deep sample results are intended for guidance in performing future all-sky surveys or pointed observations in the hard X-ray and low-energy gamma-ray band, as well as more detailed studies with the BATSE EOT.

Harmon, B. A.↗

Decision-Making in Flight with Different Convective Weather Information Sources: Preliminary Results

This paper reports preliminary and partial results of a flight experiment to address how General Aviation (GA) pilots use weather cues to make flight decisions. This research presents pilots with weather cue conditions typically available to GA pilots in visual meteorological conditions (VMC) and instrument meteorological conditions (IMC) today, as well as in IMC with a Graphical Weather Information System (GWIS). These preliminary data indicate that both VMC and GWIS-augmented IMC conditions result in better confidence, information sufficiency and perceived performance than the current IMC condition. For all these measures, the VMC and GWIS-augmented conditions seemed to provide similar pilot support. These preliminary results are interpreted for their implications on GWIS display design, training, and operational use guidelines. Final experimental results will compare these subjective data with objective data of situation awareness and decision quality.

Latorella, Kara A.↗

The Burst and Transient Source Experiment (BATSE) Earth Occultation Catalog of Low-Energy Gamma-Ray Sources

The Burst and Transient Source Experiment (BATSE), aboard the Compton Gamma Ray Observatory (CGRO), provided a record of the low-energy gamma-ray sky (approx. 20-1000 keV) between 1991 April and 2000 May (9.1 yr). BATSE monitored the high-energy sky using the Earth occultation technique (EOT) for point sources whose emission extended for times on the order of the CGRO orbital period (approx. 92 min) or greater. Using the EOT to extract flux information, a catalog of sources using data from the BATSE Large Area Detectors has been prepared. The first part of the catalog consists of results from the all-sky monitoring of 58 sources, mostly Galactic, with intrinsic variability on timescales of hours to years. For these sources, we have included tables of flux and spectral data, and outburst times for transients. Light curves (or flux histories) have been placed on the World Wide Web. We then performed a deep sampling of these 58 objects, plus a selection of 121 more objects, combining data from the entire 9.1 yr BATSE data set. Source types considered were primarily accreting binaries, but a small number of representative active galaxies, X-ray-emitting stars, and supernova remnants were also included. The sample represents a compilation of sources monitored and/or discovered with BATSE and other high-energy instruments between 1991 and 2000, known sources taken from the HEAO 1 A-4 and Macomb & Gehrels catalogs. The deep sample results include definite detections of 83 objects and possible detections of 36 additional objects. The definite detections spanned three classes of sources: accreting black hole and neutron star binaries, active galaxies, and Supernova remnants. The average fluxes measured for the fourth class, the X-ray emitting stars, were below the confidence limit for definite detection.

Harmon, B. A.↗

Free-field Calibration of the Pressure Sensitivity of Microphones at Frequencies up to 80 kHz

A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the non-uniformity of the sound field and, as applied here, uses a 1/2 -inch air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that often plague FF measurements. Calibrations were performed on 1/4-inch FF air-condenser, electret, and micro-electromechanical systems (MEMS) microphones in an anechoic chamber. The accuracy of this FF method is estimated by comparing the pressure sensitivity of an air-condenser microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration and is typically 0.3 dB (95% confidence), over the range 2-80 kHz.

Herring, G. C.↗

A Model of Thermal Conductivity for Planetary Soils: 1. Theory for Unconsolidated Soils

We present a model of heat conduction for mono-sized spherical particulate media under stagnant gases based on the kinetic theory of gases, numerical modeling of Fourier s law of heat conduction, theoretical constraints on the gas thermal conductivity at various Knudsen regimes, and laboratory measurements. Incorporating the effect of the temperature allows for the derivation of the pore-filling gas conductivity and bulk thermal conductivity of samples using additional parameters (pressure, gas composition, grain size, and porosity). The radiative and solid-to-solid conductivities are also accounted for. Our thermal model reproduces the well-established bulk thermal conductivity dependency of a sample with the grain size and pressure and also confirms laboratory measurements finding that higher porosities generally lead to lower conductivities. It predicts the existence of the plateau conductivity at high pressure, where the bulk conductivity does not depend on the grain size. The good agreement between the model predictions and published laboratory measurements under a variety of pressures, temperatures, gas compositions, and grain sizes provides additional confidence in our results. On Venus, Earth, and Titan, the pressure and temperature combinations are too high to observe a soil thermal conductivity dependency on the grain size, but each planet has a unique thermal inertia due to their different surface temperatures. On Mars, the temperature and pressure combination is ideal to observe the soil thermal conductivity dependency on the average grain size. Thermal conductivity models that do not take the temperature and the pore-filling gas composition into account may yield significant errors.

Piqueux, S.↗

The Continual Intercomparison of Radiation Codes (CIRC) Assessing Anew the Quality of GCM Radiation Algorithms

The simulation of changes in the Earth's climate due to solar and thermal radiative processes with global climate models (GCMs) is highly complex, depending on the parameterization of a multitude of nonlinearly coupled physical processes. In contrast, the germ of global climate change, the radiative forcing from enhanced abundances of greenhouse gases, is relatively well understood. The impressive agreement between detailed radiation calculations and highly resolved spectral radiation measurements in the thermal infrared under cloudless conditions (see, for example, Fig. 1) instills confidence in our knowledge of the sources of gaseous absorption. That the agreement spans a broad range of temperature and humidity regimes using instruments mounted on surface, aircraft, and satellite platforms not only attests to our capability to accurately calculate radiative fluxes under present conditions, but also provides confidence in the spectroscopic basis for computation of fluxes under conditions that might characterize future global climate (e.g., radiative forcing). Alas, the computational costs of highly resolved spectral radiation calculations cannot be afforded presently in GCMs. Such calculations have instead been used as the foundation for approximations implemented in fast but generally less accurate algorithms performing the needed radiative transfer (RT) calculations in GCMs. Credible climate simulations by GCMs cannot be ensured without accurate solar and thermal radiative flux calculations under all types of sky conditions: pristine cloudless, aerosol-laden, and cloudy. The need for accuracy in RT calculations is not only important for greenhouse gas forcing scenarios, but is also profoundly needed for the robust simulation of many other atmospheric phenomena, such as convective processes.

Oreopoulos, Lazaros↗

Laser Diffraction Techniques Replace Sieving for Lunar Soil Particle Size Distribution Data

Sieving was used extensively until 1999 to determine the particle size distribution of lunar samples. This method is time-consuming, and requires more than a gram of material in order to obtain a result in which one may have confidence. This is demonstrated by the difference in geometric mean and median for samples measured by [1], in which a 14-gram sample produced a geometric mean of approx.52 micrometers, whereas two other samples of ~1.5 grams resulted in gave means of approx.63 and approx.69 micrometers. Sample allocations for sieving are typically much smaller than a gram, and many of the sample allocations received by our lab are 0.5 to 0.25 grams in mass. Basu [2] has described how the finest fraction of the soil is easily lost in the sieving process, and this effect is compounded when sample sizes are small.

Cooper, Bonnie L.↗

Designing an Exploration Atmosphere Prebreathe Protocol

Extravehicular activities (EVAs) at remote locations must maximize limited resources such as oxygen (O2) and also minimize the risk of decompression sickness (DCS). A proposed remote denitrogenation (prebreathe) protocol requires astronauts to live in a mildly hypoxic atmosphere at 8.2 psia while periodically performing EVAs at 4.3 psia. Empirical data are required to confirm that the protocol meets the current accept requirements: less than or equal to 15% incidence of Type I DCS, less than or equal to 20% incidence of Grade IV venous gas emboli (VGE), both at 95% statistical confidence, with no Type II DCS symptom during the validation trial. METHODS: A repeated measures statistical design is proposed in which groups of 6 subjects with physical characteristics similar to active-duty astronauts would first become equilibrated to an 8.2 psia atmosphere in a hypobaric chamber containing 34% O2 and 66% N2, over 48 h, and then perform 4 simulated EVAs at 4.3 psia over the next 9 days. In the equilibration phase, subjects undergo a 3-h 100% O2 mask prebreathe prior to and during a 5-min ascent to 8.2 psia to prevent significant tissue N2 supersaturation on reaching 8.2 psia. Masks would be removed once 34% O2 is established at 8.2 psia, and subjects would then equilibrate to this atmosphere for 48 h. The hypoxia is equivalent to breathing air at 1,220 meters (4,000 ft) altitude, just as was experienced in the shuttle 10.2 psia - 26.5% O2 staged denitrogenation protocol and the current ISS campout denitrogenation protocol. For simulated EVAs, each subject dons a mask and breathes 85% O2 and 15% N2 during a 3-min depressurization to 6.0 psia, holds for 15 min, and then completes a 3-min depressurization to 4.3 psia. The simulated EVA period starts when 6.0 psia is reached and continues for a total of 240 min (222 min at 4.3 psia). During this time, subjects will follow a prescribed repetitive activity against loads in the upper and lower body with mean metabolic rate approaching 1500 BTU/hr [378 kcal/hr (O2 consumption about 1.3 l(sub STPD)/min)] in ambulatory subjects. Noninvasive Doppler ultrasound bubble monitoring for VGE in the pulmonary artery will be performed on subjects by 2 Doppler Technicians at about 15 min intervals while at 4.3 psia. At the end of this period, a 15-min repressurization returns all subjects back to 8.2 psia and the cycle is repeated 3 additional times with a day of rest between simulated EVAs. RESULTS: With an assumed 1.5% probability of DCS [P(DCS)] and accounting for within-subject correlation, running the proposed study with 20 subjects has a 95% probability of meeting the accept criterion for DCS. But if the true probability of DCS is 3.0%, then 30 subjects would be needed to achieve about the same probability to meet our accept criterion. These results assume a standard deviation of 1.4 for the between-subjects random component of P(DCS) on a logit scale, which was estimated from a previous study.

Conkin, Johnny↗

IGR J170626143 is an Accreting Millisecond X-Ray Pulsar

We present the discovery of 163.65 Hz X-ray pulsations from IGR J17062−6143 in the only observation obtained from the source with the Rossi X-ray Timing Explorer. This detection makes IGR J17062−6143 the lowest frequency accreting millisecond X-ray pulsar presently known. The pulsations are detected in the 2-12 keV band with an overall significance of 4.3sigma and an observed pulsed amplitude of 5.54% +/-0.67% (in this band). Both dynamic power spectral and coherent phase timing analysis indicate that the pulsation frequency is decreasing during the approx. =1.2 ks observation in a manner consistent with orbital motion of the neutron star. Because the observation interval is short, we cannot precisely measure the orbital period; however, periods shorter than 17 minutes are excluded at 90% confidence. For the range of acceptable circular orbits the inferred binary mass function substantially overlaps the observed range for the AMXP population as a whole.

stars: neutron↗

Pronghorn Porous Media Model Validation with Pressure Drop Measurements

The verification and validation (V&V) of Pronghorn is imperative to assert its accuracy when predicting the fluid velocity, temperature, and pressure in high temperature gas-cooled reactors. Pronghorn is a coarse-mesh, intermediate-fidelity, and multidimensional thermal-hydraulics (TH) code developed by the Idaho National Laboratory (INL). New pebble bed experiments are used to observe the details of the fluid motion and pressure drop in the porous bed under the reactor normal operation. This paper focuses on the validation of the Pronghorn compressible and incompressible Navier-Stokes equations using the pressure drop measurements performed at the engineering-scale pebble bed facility at the Texas A&M university (TAMU). Various pressure drop correlations and porosity functions are implemented in both Pronghorn and STAR-CCM+ to compare the pressure drop due to the combined viscous and inertial resistances in the porous bed. The correlations accounting for the near-wall effect are also utilized to observe if the pressure drop estimates can be improved. Pronghorn porous media models predict the pressure drop well relative to the STAR-CCM+ simulation results and 1D correlations, and both the finite element method (FEM) and finite volume method (FVM) perform accurately. Pronghorn models are also validated with the experimental measurements given the different Reynolds number ranges and specific aspect ratios. The likelihood of the statistical significance between the pressure drop measurements and specific correlations or simulations is low provided that the overlap of their confidence intervals is more than the half of a single arm. Several validation metrics are reasonable in regard to the similar studies from other literature. The precise average pebble bed porosity estimation has much impact on the pressure drop, and the Foumeny and Montillet (dense packing) models carry out the accurate pressure drop prediction by considering the near-wall effect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Temperature Dielectric Properties and Differential Scanning Calorimetry of Lunar Simulants

To guide development of microwave process technology that could be used during in situ construction on the Moon, we measured the high-temperature basic dielectric properties (εʹ and εʺ) of 17 lunar simulants and related materials. In order to confidently use these data one needs to understand the data’s strengths and weaknesses. Therefore, a goal of this publication is to provide insights into the comparative effects of sample composition, pre-treatments, experimental variables, high temperatures, and other factors on the measured response. The dielectric measurements were performed using the cavity perturbation method over a temperature range between room temperature to 1000 °C, or higher, and provided the real and imaginary components of permittivity at six frequencies. The utility of the original values was limited by the varying density of the pellets used in the measurement. Therefore, all of the εʹ and εʺ measurements at the frequency of 2466 MHz have been scaled to a constant density, 1.75 g/cm 3 . Here the data are presented as graphs chosen to aid analysis within and across simulant groups. To gain additional insight into the processes happening at the elevated temperatures in the dielectric measurements, heat capacity data was obtained using differential scanning calorimetry (DSC) on several of the simulant materials. Our data show that over the frequency range 397 MHz – 2985 MHz a material’s behavior does not greatly change, as compared to the scale of differences observed between lunar mare and highland simulants at high temperatures. For example at 1000 °C, the mare simulant JSC-1A absorbs 10 times more power than the highland simulant NUW-LHT-5M. We observe that as melting temperatures are reached both permittivity and dielectric loss rise non-linearly, helping to explain thermal runaway during microware heating. Our data show that even less than a few weight % of many non-lunar minerals, and the use of mixtures in simulants can affect the dielectric behavior at higher temperatures. A comparison of our results with published dielectric data for Apollo samples and with remote sensing of the Moon supports the conclusion the simulants and lunar material at room temperature have very similar dielectric values.

Differential Scanning Calorimetry↗

Flash photolysis resonance fluorescence investigation of the reaction of Cl/2P/ atoms with ClONO2

Rate constants for the removal of Cl(2P) atoms by homogeneous gas phase reaction with ClONO2 were measured using the flash photolysis resonance fluorescence technique at 224, 250, and 273 K. The values obtained have been used to derive the above Arrhenius equation. The uncertainties expressed are 95% confidence limits obtained using the statistical standard deviation of the individual rate constants plus a 15% additional estimated uncertainty attributed to difficulties in chlorine nitrate concentration measurements. The results indicate that destruction of chlorine nitrate by reaction with chlorine atoms is perhaps the least important of the atmospheric reactive channels, and is at least three orders of magnitude slower than calculated photodissociation rates at all stratospheric altitudes.

Kurylo, M. J.↗

The Uncertainty of Biomass Estimates from Modeled ICESat-2 Returns Across a Boreal Forest Gradient

The Forest Light (FLIGHT) radiative transfer model was used to examine the uncertainty of vegetation structure measurements from NASA's planned ICESat-2 photon counting light detection and ranging (LiDAR) instrument across a synthetic Larix forest gradient in the taiga-tundra ecotone. The simulations demonstrate how measurements from the planned spaceborne mission, which differ from those of previous LiDAR systems, may perform across a boreal forest to non-forest structure gradient in globally important ecological region of northern Siberia. We used a modified version of FLIGHT to simulate the acquisition parameters of ICESat-2. Modeled returns were analyzed from collections of sequential footprints along LiDAR tracks (link-scales) of lengths ranging from 20 m-90 m. These link-scales traversed synthetic forest stands that were initialized with parameters drawn from field surveys in Siberian Larix forests. LiDAR returns from vegetation were compiled for 100 simulated LiDAR collections for each 10 Mg · ha(exp -1) interval in the 0-100 Mg · ha(exp -1) above-ground biomass density (AGB) forest gradient. Canopy height metrics were computed and AGB was inferred from empirical models. The root mean square error (RMSE) and RMSE uncertainty associated with the distribution of inferred AGB within each AGB interval across the gradient was examined. Simulation results of the bright daylight and low vegetation reflectivity conditions for collecting photon counting LiDAR with no topographic relief show that 1-2 photons are returned for 79%-88% of LiDAR shots. Signal photons account for approximately 67% of all LiDAR returns, while approximately 50% of shots result in 1 signal photon returned. The proportion of these signal photon returns do not differ significantly (p greater than 0.05) for AGB intervals greater than 20 Mg · ha(exp -1). The 50m link-scale approximates the finest horizontal resolution (length) at which photon counting LiDAR collection provides strong model fits and minimizes forest structure uncertainty in the synthetic Larix stands. At this link-scale AGB greater than 20 Mg · ha(exp -1) has AGB error from 20-50% at the 95% confidence level. These results suggest that the theoretical sensitivity of ICESat-2 photon counting LiDAR measurements alone lack the ability to consistently discern differences in inferred AGB at 10 Mg · ha(exp -1) intervals in sparse forests characteristic of the taiga-tundra ecotone.

LiDAR↗

Measurement of the CP-violating phase ϕ s in B$_s^0$→J/ψϕ decays in ATLAS at 13 TeV

A measurement of the B$_s^0$→J/ψϕ decay parameters using 80.5 fb -1 of integrated luminosity collected with the ATLAS detector from 13 Te proton–proton collisions at the LHC is presented. The measured parameters include the CP-violating phase ϕ s , the width difference Δ Γ s between the B$_s^0$ meson mass eigenstates and the average decay width Γ s . The values measured for the physical parameters are combined with those from 19.2fb -1 of 7 and 8 Te data, leading to the following: ϕs=-0.087±0.036(stat.)±0.021(syst.)rad ΔΓ s =0.0657±0.0043(stat.)±0.0037(syst.)ps -1 Γ s =0.6703±0.0014(stat.)±0.0018(syst.)ps -1 Results for ϕ s and Δ Γ s are also presented as 68% confidence level contours in the ϕ s –Δ Γ s plane. Furthermore the transversity amplitudes and corresponding strong phases are measured. ϕ s and Δ Γ s measurements are in agreement with the Standard Model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Energy Survey: A 2.1% measurement of the angular baryonic acoustic oscillation scale at redshift z eff = 0.85 from the final dataset

Here, we present the angular diameter distance measurement obtained with the baryonic acoustic oscillation (BAO) feature from galaxy clustering in the completed Dark Energy Survey, consisting of six years (Y6) of observations. We use the Y6 BAO galaxy sample, optimized for BAO science in the redshift range 0.6 < z <1.2, with an effective redshift at z eff = 0.85 and split into six tomographic bins. The sample has nearly 16 million galaxies over 4,273 square degrees. Our consensus measurement constrains the ratio of the angular distance to sound horizon scale to D M ⁡(z eff )/r d = 19.51 ± 0.41 (at 68.3% confidence interval), resulting from comparing the BAO position in our data to that predicted by planck Λ⁢CDM via the BAO shift parameter α =(D M /r d )/(D M /r d ) PLANCK . To achieve this, the BAO shift is measured with three different methods, angular correlation function (ACF), angular power spectrum (APS), and projected correlation function (PCF), obtaining α = 0.952 ± 0.023, 0.962 ± 0.022, and 0.955 ± 0.020, respectively, which we combine to α = 0.957 ± 0.020, including systematic errors. When compared with the Λ⁢CDM model that best fits planck data, this measurement is found to be 4.3% and 2.1⁢σ below the angular BAO scale predicted. To date, it represents the most precise angular BAO measurement at z > 0.75 from any survey and the most precise measurement at any redshift from photometric surveys. The analysis was performed blinded to the BAO position, and it is shown to be robust against analysis choices, data removal, redshift calibrations, and observational systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

A data analysis method to rapidly characterize gallium concentration in plutonium matrices using LIBS

The processing of actinide samples is a complex and costly endeavor that requires compositional analysis at various stages. Laser-induced breakdown spectroscopy (LIBS) has been used to analyze actinide-containing samples in many nuclear applications including waste management, fuel processing and forensics. The LIBS spectrum obtained from actinide materials are generally extremely complex, exhibiting many thousands of strong emission lines. This makes it difficult to identify other elements within the sample of interest, given the rich and dominant actinide spectrum. Here, in this article, we describe a recent effort to identify and quantify impurities and alloying constituents in plutonium matrices using a hand-held LIBS instrument that is used to rapidly and efficiently measure an emission spectrum from a material sample. We tabulate the emission line positions and intensities of plutonium. We report the development of machine-learning software that can identify gallium and quantify its concentration in plutonium matrices. This work has the potential to provide a rapid and nearly non-destructive technique that allows more confidence in characterizing the composition of materials that are present within complex actinide associated targets. We describe how our LIBS measurements and data analysis methods have successfully quantified the gallium concentration in a variety of samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗