Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Surface characterization based on optical phase shifting interferometry

Apparatus, techniques and systems for implementing an optical interferometer to measure surfaces, including mapping of instantaneous curvature or in-plane and out-of-plane displacement field gradients of a sample surface based on obtaining and processing four optical interferograms from a common optical reflected beam from the sample surface that are relatively separated in phase by .pi./2.

47 OTHER INSTRUMENTATION↗

Motion drive system is accurately controlled in the 1-micron range

Motion drive system has been developed for use with interferometers where accurate control of minuscule distance in the 1-micron range is of prime importance. The drive system is applicable to any device that requires extremely accurate positioning control.

Morecroft, J. H.↗

Pulsed laser spectral measurement using a Fabry-Perot interferometer: Limits to resolution

We are developing a Doppler lidar system using the edge technique to measure atmospheric wind profiles. The edge technique requires a laser with a narrow spectral bandwidth and a high resolution optical filter. The lidar system will use a Nd:YAG laser operating at 1.064 microns and a high resolution Fabry-Perot interferometer for the edge filter. The Doppler shift measurement is made by locating the laser on the edge of the filter's spectral response function. Due to the steep slope on the edge, large changes in the filter transmission will be observed for small changes in frequency. The Doppler shift can be determined from a measurement of this change in filter transmission if the filter spectral response function in the region of the measurement is well known. Recently developed injection seeded solid state lasers have made near transform limited laser output readily available for lidar work. Injection-seeded Nd:YAG laser exhibit single mode output with smooth Gaussian temporal pulse shapes. Results of an experiment we conducted to evaluate the effects of a short Gaussian temporal input pulse on the spectral response of a high resolution Fabry-Perot interferometer are presented.

Notari, Anthony↗

Optical multi-species gas monitoring sensor and system

The system includes at least one light source generating light energy having a corresponding wavelength. The system's sensor is based on an optical interferometer that receives light energy from each light source. The interferometer includes a free-space optical path disposed in an environment of interest. The system's sensor includes an optical device disposed in the optical path that causes light energy of a first selected wavelength to continue traversing the optical path whereas light energy of at least one second selected wavelength is directed away from the optical path. The interferometer generates an interference between the light energy of the first selected wavelength so-traversing the optical path with the light energy at the corresponding wavelength incident on the optical interferometer. A first optical detector detects the interference. At least one second detector detects the light energy at the at least one second selected wavelength directed away from the optical path.

Polzin, Kurt A.↗

Exozodiacal Disk Detection Potential with the Keck Interferometer

If the dust content of nearby solar system is comparable to, or larger than, that of our own zodiacal disk, the thermal emission from exozodiacal disks will significantly outshine planetary companions to nearby stars.

exozodiacal disk Keck interferometer MIR Keck null↗

Electron Beam Diagnostics Of The JLAB UV FEL

In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A system of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.

43 PARTICLE ACCELERATORS↗

Entanglement-enhanced matter-wave interferometry in a high-finesse cavity

An ensemble of atoms can operate as a quantum sensor by placing atoms in a superposition of two different states. Upon measurement of the sensor, each atom is individually projected into one of the two states. Creating quantum correlations between the atoms, that is entangling them, could lead to resolutions surpassing the standard quantum limit set by projections of individual atoms. Large amounts of entanglement involving the internal degrees of freedom of laser-cooled atomic ensembles have been generated in collective cavity quantum-electrodynamics systems, in which many atoms simultaneously interact with a single optical cavity mode. Here we report a matter-wave interferometer in a cavity quantum-electrodynamics system of 700 atoms that are entangled in their external degrees of freedom. In our system, each individual atom falls freely under gravity and simultaneously traverses two paths through space while entangled with the other atoms. In this work, we demonstrate both quantum non-demolition measurements and cavity-mediated spin interactions for generating squeezed momentum states with directly observed sensitivity $3.4^{+1.1}_{–0.9}$dB and $2.5^{+0.6}_{–0.6}$dB below the standard quantum limit, respectively. We successfully inject an entangled state into a Mach–Zehnder light-pulse interferometer with directly observed sensitivity $1.7^{+0.5}_{–0.5}$dB below the standard quantum limit. The combination of particle delocalization and entanglement in our approach may influence developments of enhanced inertial sensors, searches for new physics, particles and fields, future advanced gravitational wave detectors and accessing beyond mean-field quantum many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Inscription and Visualization of Tilted Fiber Bragg Gratings

Tilted fiber Bragg gratings with different tilt angles have been inscribed in single-mode isotropic optical fiber with an increased photorefractivity using Talbot interferometer and KrF-excimer laser system. Their spectra are studied. Using a confocal laser scanning luminescent microscope the images of gratings in transmitted light were obtained. The calculated dependence of the slope angle of the grating recorded in the Talbot interferometer on the angle between the strokes of the interference pattern created in the interferometer and the transverse section of the optical fiber is experimentally verified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evolutionary Design of Controlled Structures

Basic physical concepts of structural delay and transmissibility are provided for simple rod and beam structures. Investigations show the sensitivity of these concepts to differing controlled-structures variables, and to rational system modeling effects. An evolutionary controls/structures design method is developed. The basis of the method is an accurate model formulation for dynamic compensator optimization and Genetic Algorithm based updating of sensor/actuator placement and structural attributes. One and three dimensional examples from the literature are used to validate the method. Frequency domain interpretation of these controlled structure systems provide physical insight as to how the objective is optimized and consequently what is important in the objective. Several disturbance rejection type controls-structures systems are optimized for a stellar interferometer spacecraft application. The interferometric designs include closed loop tracking optics. Designs are generated for differing structural aspect ratios, differing disturbance attributes, and differing sensor selections. Physical limitations in achieving performance are given in terms of average system transfer function gains and system phase loss. A spacecraft-like optical interferometry system is investigated experimentally over several different optimized controlled structures configurations. Configurations represent common and not-so-common approaches to mitigating pathlength errors induced by disturbances of two different spectra. Results show that an optimized controlled structure for low frequency broadband disturbances achieves modest performance gains over a mass equivalent regular structure, while an optimized structure for high frequency narrow band disturbances is four times better in terms of root-mean-square pathlength. These results are predictable given the nature of the physical system and the optimization design variables. Fundamental limits on controlled performance are discussed based on the measured and fit average system transfer function gains and system phase loss.

Masters, Brett P.↗

MSTAR: an absolute metrology system with submicrometer accuracy

Laser metrology systems are a key component of stellar interferometers, used to monitor path lengths and dimensions internal to the instrument. Most interferometers use ‘relative’ metrology, in which the integer number of wavelengths along the path is unknown, and the measurement of length is ambiguous. Changes in the path length can be measured relative to an initial calibration point, but interruption of the metrology beam at any time requires a re- calibration of the system. iThe MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. We describe the design of the system, show results for target distances up to 1 meter, and demonstrate how the system can be scaled to kilometer-scale distances. In recent experiments, we have used white light interferometry to augment the ‘truth’ measurements and validate the zero-point of the system. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications.

Lay, Oliver↗

Controlled structures technology and the design of an optical interferometer spacecraft

The impact of extremely stringent structural control requirements and controlled structures techniques on the overall design of a spacecraft system is examined. A space-based optical interferometer presents a design case that necessitates the application of controlled structures technology. In order for interferometry to succeed, differential pathlengths between the optical components need to be identical within a fraction of a wavelength of the light (about 25 nm for visible light). This high level of precision must be maintained on a large, flexible structure in the face of common spacecraft vibrational disturbances. Aspects of spacecraft design are examined to determine the impact of structural control on the 'normal' design process. Structural control objectives can drive several choices in subsystem component selection and sizing that minimize the vibrational environment.

Nisbet, Andrew M.↗

MSTAR: an absolute metrology system with submicrometer accuracy

Laser metrology systems are a key component of stellar interferometers, used to monitor path lengths and dimensions internal to the instrument. Most interferometers use ‘relative’ metrology, in which the integer number of wavelengths along the path is unknown, and the measurement of length is ambiguous. Changes in the path length can be measured relative to an initial calibration point, but interruption of the metrology beam at any time requires a re-calibration of the system. The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. We describe the design of the system, show results for target distances up to 1 meter, and demonstrate how the system can be scaled to kilometer-scale distances. In recent experiments, we have used white light interferometry to augment the ‘truth’ measurements and validate the zero-point of the system. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications

Fetterman, Harrold R.↗

Descriptions of a linear device developed for research on advanced plasma imaging and dynamics

The research on advanced plasma imaging and dynamics (RAPID) device is a newly developed linear electron cyclotron resonance (ECR) plasma device. It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. A 6 kW 2.45 GHz magnetron is used to produce steady-state ECR plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). The cylindrical stainless steel vacuum chamber is 300 mm in diameter and 750 mm in length and has eight radial and ten axial ports including 6-in. and 8-in. viewing windows for heating and diagnostics. Experimental observation of ECR plasma heating has been recently carried out during the initial plasma operation. The main diagnostic systems including a 94 GHz heterodyne interferometer, a high-resolution 25 channel one-dimensional array spectrometer, a single channel survey spectrometer, and an electric probe have been also prepared. The RAPID device is a flexible simulator for the understanding of tokamak edge plasma physics and new diagnostic system development. In this work, we describe the RAPID device and initial operation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A real-time laser feedback control method for the three-wave laser source used in the polarimeter-interferometer diagnostic on Joint-TEXT tokamak

A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (∼100–∼500 kHz/10 min) and decay of laser power (∼10%–∼20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabry-Perot interferometer utilized for displacement measurement in a large measuring range

The optical configuration of a Fabry-Perot interferometer is uncomplicated. This has already been applied in different measurement systems. For the displacement measurement with the Fabry-Perot interferometer, the result is significantly influenced by the tilt angles of the measurement mirror in the interferometer. Hence, only for the rather small measuring range, the Fabry-Perot interferometer is available. The goal of this investigation is to enhance the measuring range of Fabry-Perot interferometer by compensating the tilt angles. To verify the measuring characteristic of the self-developed Fabry-Perot interferometer, some comparison measurements with a reference standard have been performed. The maximum deviation of comparison experiments is less than 0.3 {mu}m in the traveling range of 30 mm. The experimental results show that the Fabry-Perot interferometer is highly stable, insensitive to environment effects, and can meet the measuring requirement of the submicrometer order.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Status of the Development of a Transportable and Compact VLBI System by NICT and GSI

MARBLE (Multiple Antenna Radio-interferometer for Baseline Length Evaluation) is under development by NICT and GSI. The main part of MARBLE is a transportable VLBI system with a compact antenna. The aim of this system is to provide precise baseline length over about 10 km for calibrating baselines. The calibration baselines are used to check and validate surveying instruments such as GPS receiver and EDM (Electro-optical Distance Meter). It is necessary to examine the calibration baselines regularly to keep the quality of the validation. The VLBI technique can examine and evaluate the calibration baselines. On the other hand, the following roles are expected of a compact VLBI antenna in the VLBI2010 project. In order to achieve the challenging measurement precision of VLBI2010, it is well known that it is necessary to deal with the problem of thermal and gravitational deformation of the antenna. One promising approach may be connected-element interferometry between a compact antenna and a VLBI2010 antenna. By measuring repeatedly the baseline between the small stable antenna and the VLBI2010 antenna, the deformation of the primary antenna can be measured and the thermal and gravitational models of the primary antenna will be able to be constructed. We made two prototypes of a transportable and compact VLBI system from 2007 to 2009. We performed VLBI experiments using theses prototypes and got a baseline length between the two prototypes. The formal error of the measured baseline length was 2.7 mm. We expect that the baseline length error will be reduced by using a high-speed A/D sampler.

Ishii, Atsutoshi↗

Interferometric null test of a deep parabolic reflector generating a Hertzian dipole field

We report on interferometric characterization of a deep parabolic mirror with a depth of more than five times its focal length. The interferometer is of Fizeau type; its core consists of the mirror itself, a spherical null element, and a reference flat. Because of the extreme solid angle produced by the paraboloid, the alignment of the setup appears to be very critical and needs auxiliary systems for control. Aberrations caused by misalignments are removed via fitting of suitable functionals provided by means of ray tracing simulations. It turns out that the usual misalignment approximations fail under these extreme conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TARGET SELECTION FOR THE LBTI EXOZODI KEY SCIENCE PROGRAM

The Hunt for Observable Signatures of Terrestrial planetary Systems (HOSTS) on the Large Binocular Telescope Interferometer will survey nearby stars for faint emission arising from ∼300 K dust (exozodiacal dust), and aims to determine the exozodiacal dust luminosity function. HOSTS results will enable planning for future space telescopes aimed at direct spectroscopy of habitable zone terrestrial planets, as well as greater understanding of the evolution of exozodiacal disks and planetary systems. We lay out here the considerations that lead to the final HOSTS target list. Our target selection strategy maximizes the ability of the survey to constrain the exozodi luminosity function by selecting a combination of stars selected for suitability as targets of future missions and as sensitive exozodi probes. With a survey of approximately 50 stars, we show that HOSTS can enable an understanding of the statistical distribution of warm dust around various types of stars and is robust to the effects of varying levels of survey sensitivity induced by weather conditions.

79 ASTRONOMY AND ASTROPHYSICS↗