Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Search for Electron Neutrino Anomalies with the MicroBooNE Detector

The Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) located in the Booster Neutrino Beam at Fermi National Accelerator Laboratory. The experiment was devised to investigate a series of observed anomalies concerning short-baseline neutrino oscillation physics. The LArTPC technology enables the experiment to study neutrino-argon scattering with unprecedented detail.This thesis presents a cosmic-ray characterisation and rate measurement. The understanding of cosmic activity in the detector - MicroBooNE's dominant background - is then used to develop cosmic rejection tools. A flavour-agnostic neutrino selection is constructed, which forms the cornerstone of this and further analyses. Inclusive muon and electron charged-current neutrino interaction selections with unprecedented purity and efficiency are presented.The first fully-automated characterisation of electron neutrinos in a muon neutrino beam with the LArTPC detector technology is performed. The Booster Neutrino Beam has an energy peaking around 1GeV and an intrinsic electron content of approximately 0.5%. The analysis investigates electrons produced in charged-current electron neutrino interactions. The kinematics of the electrons are measured along with comparisons to simulation. Most of the systematic uncertainties are constrained using a data-driven sample of charged-current muon neutrino events. The measurement of electron neutrinos originating from the Booster Neutrino Beam is a crucial component towards understanding the nature of the observed excess of low-energy electromagnetic-like events at its predecessor, MiniBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for solar axions produced through the axion-electron coupling gae using a new GridPix detector at CAST

We present a search for solar axions produced through the axion-electron coupling (g ae ) using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride windows and multiple veto systems, collected approximately 160 hours of solar tracking data between 2017–2018. Using machine learning techniques and the veto systems, we achieved a background rate of 1.06 × 10 −5 keV −1 cm −2 s −1 at a signal efficiency of about 80% in the 0.2 to 8 keV range. Analysis of the data yielded no significant excess above background, allowing us to set a new upper limit on the product of the axion-electron and axion-photon couplings of g ae · g aγ < 7.35 × 10 −23 GeV −1 at 95% confidence level for axion masses below 10 meV. This result improves upon the previous best helioscope limit and demonstrates the potential of GridPix technology for rare event searches. Additionally, we derived a limit on the axion-photon coupling of g aγ < 9.0 × 10 −11 GeV −1 at 95% CL, which, while not surpassing CAST’s best limit, provides complementary constraints on axion models.

Beyond Standard Model↗

Electron calibration on a high-energy cosmic ray detector.

The response of the GSFC High Energy Cosmic Ray Detector has been studied using electrons in the energy range from 5.4 to 18 GeV. A semiempirical analytic form has been developed to determine the starting points and the energies of electron-induced cascade showers. The energy resolution thus obtained has a full width at half maximum of 17%, and the starting point can be determined to within 0.1 to 0.2 radiation length. The results of this response calibration provide a basis on which cosmic ray electrons can be reliably identified and analyzed in the presence of a large proton background.

Crannell, C. J.↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Controlling the Focus in Electron-Beam Welders

Detector using two whirling wires measures focus of beam in electronbeam welder. Multiple-wire beam-sampling method provides for simple nullmeter focus indication easily controlled by operator. Detector not only operates at high beam currents but eliminates need for oscilloscope.

Macfarlane, D. I.↗

Measurement of space charge effects in the MicroBooNE LArTPC using cosmic muons

Large liquid argon time projection chambers (LArTPCs), especially those operating near the surface, are susceptible to space charge effects. In the context of LArTPCs, the space charge effect is the build-up of slow-moving positive ions in the detector primarily due to ionization from cosmic rays, leading to a distortion of the electric field within the detector. This effect leads to a displacement in the reconstructed position of signal ionization electrons in LArTPC detectors ("spatial distortions"), as well as to variations in the amount of electron-ion recombination experienced by ionization throughout the volume of the TPC. We present techniques that can be used to measure and correct for space charge effects in large LArTPCs by making use of cosmic muons, including the use of track pairs to unambiguously pin down spatial distortions in three dimensions. Finally, the performance of these calibration techniques are studied using both Monte Carlo simulation and MicroBooNE data, utilizing a UV laser system as a means to estimate the systematic bias associated with the calibration methodology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nighttime observations of 0.2- to 26-keV electrons in the South Atlantic anomaly made by Atmosphere Explorer C

Atmosphere Explorer C satellite observations have determined that the flux of low energy ions in the South Atlantic Anomaly is much smaller than that of electrons, allowing the satellite's low-energy ion detector to monitor the high-energy background and correct the low-energy electron detector accordingly. It is shown that the electron spectra can be represented by a power law in the range 0.2-26.0 keV, with the spectral index close to -1.0, and that the mean energy flux carried by electrons in the middle of the anomaly is about 0.003 erg/sq cm/sec and may reach 5 times this value. Maps of the downward energy flux are included.

Gledhill, J. A.↗

Equatorial X-rays and their effect on the lower mesosphere

On the night of May 23/24, 1975, a sequence of rocket and balloon experiments was launched from Chilca Base, Peru (12.5 deg S, 76.8 deg W, magnetic dip = - 0.7 deg). Detailed analysis and comparisons of the data yielded the first direct measurement of lower mesospheric response to a galactic X-ray source. This result could only have been determined at the equator, where cosmic ray background effects are minimal. The objective of the experiments was to seek out the equatorial energetic electron belt, sporadically reported to contain fluxes near auroral levels, measure the bremsstrahlung radiation produced by this particle belt, and determine the influence of this radiation on the middle atmosphere. High altitude rocket payloads (Nike Tomahawk 18.170 and 18.171) were launched to probe the thermosphere during and following the anticipated downward drift period. Each carried an on-axis X-ray scintillation detector and Geiger Mueller energetic electron detectors. Magnetometers and lunar sensors were used to determine payload aspect.

Goldberg, R. A.↗

Spaceflight KID Readout Electronics Development for PRIMA

We present the design and testing of spaceflight multiplexing kinetic inductance detector (KID) readout electronics for the PRobe far-Infrared Mission for Astrophysics (PRIMA). PRIMA is a mission proposed to the 2023 NASA Astrophysics Probe Explorer (APEX) Announcement of Opportunity that will answer fundamental questions about the formation of planetary systems, as well as the formation and evolution of stars, supermassive black holes, and dust over cosmic time. The readout electronics for PRIMA must be compatible with operation at Earth-Sun L2 and capable of multiplexing more than 1000 detectors over 2 GHz bandwidth while consuming around 30 W per readout chain. The electronics must also be capable of switching between the two instruments, which have different readout bands,: the hyperspectral imager (PRIMAger, 2.5-5.0 GHz) and the spectrometer (FIRESS, 0.4-2.4 GHz). We present the driving requirements, design, and measured performance of a laboratory brassboard system.

Sumit Dahal↗

Observation of time-dependent internal charge amplification in a planar germanium detector at cryogenic temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 min after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keVγ rays from a 241 Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold (< 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

Studies of the earth-limb absorptions in the near ultraviolet

The use of solar occultation techniques as a means of obtaining data on the photochemistry of the ozone layer was investigated. A spectrometer equipped with a photomultiplier detector and associated electronics necessary to amplify the output of the detector up to a level suitable for on-board recording and also for telemetering to the ground, was packaged with a solar telescope and flown by balloon in order to obtain solar spectra in the region between 3080 A and 3100 A with a resolution of close to 0.05 A. Data reduction techniques required to remove solar OH lines from atmospheric OH line spectra are described as well as the instrument package.

Murcray, D. G.↗

Primary cosmic ray electrons above 10 GeV - Measurements using a thick detector

A balloon-borne measurement of the cosmic ray electron spectrum from 10 to 200 GeV is reported in which two new techniques have been used to remove proton background contamination. First, the depth of the spectrometer was more than 40 radiation lengths, the equivalent of more than 3 mean free paths of material, enabling hadronically and electromagnetically induced cascades to be differentiated for a subset of the data. Second, electromagnetic cascade starting points were determined to within plus or minus 0.1 radiation lengths on the basis of a calibration with electrons from 5.4 to 18 GeV at the Stanford Linear Accelerator, greatly reducing the chances for a proton to simulate an electron. The resulting spectrum, when fitted with a power law, is quite steep, -3.2 plus or minus 0.1, but the fit to a power law is marginal.

Silverberg, R. F.↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The recent discovery of high temperature ceramic superconductors with transition temperatures above 90 K has opened the possibilities for new space applications. One application is the fabrication of an electrically conducting and thermally isolating electronic link to connect IR detectors to data acquisition electronics on remote sensing platforms. The Spectroscopy of the Atmosphere using Far Infra-Red Emission (SAFIRE) mission is an example of a platform which employs hybrid dewars and combines both mechanical and cryogenic liquid cooling. This new technology is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). This link must be made of material that has high electrical conductivity and high thermal resistance. The YBa2Cu3O(x) superconductor with a transition temperature, T(sub c), of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. A reduction of the thermal load due to the link by a factor of four will increase the lifetime of a seven year mission by about one year.

Selim, Raouf L.↗

Improved Electromechanical Infrared Sensor

Proposed electromechanical infrared detector improved version of device described in "Micromachined Electron-Tunneling Infrared Detectors" (NPO-18413). Fabrication easier, and undesired sensitivity to acceleration reduced. In devices, diaphragms and other components made of micromachined silicon, and displacements of diaphragms measured by electron tunneling displacement transducer {see "Micromachined Tunneling Accelerometer" (NPO-18513)}. Improved version offers enhanced frequency response and less spurious response to acceleration.

Kenny, Thomas W.↗

Search for two neutrino double electron capture of 124 Xe and 126 Xe in the full exposure of the LUX detector

Two-neutrino double electron capture is a process allowed in the Standard Model of Particle Physics. This rare decay has been observed in $^{78}$Kr, $^{130}$Ba and more recently in $^{124}$Xe. In this publication we report on the search for this process in $^{124}$Xe and $^{126}$Xe using the full exposure of the Large Underground Xenon (LUX) experiment, in a total of of 27769.5~kg-days. No evidence of a signal was observed, allowing us to set 90\% C.L. lower limits for the half-lives of these decays of $2.0\times10^{21}$~years for $^{124}$Xe and $1.9\times10^{21}$~years for $^{126}$Xe.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The upgrade of the ALICE TPC with GEMs and continuous readout

The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.

47 OTHER INSTRUMENTATION↗