Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OMEGA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Absolute calibration of the OMEGA streaked optical pyrometer for temperature measurements of compressed materials

Experiments in high-energy-density physics often use optical pyrometry to determine temperatures of dynamically compressed materials. In combination with simultaneous shock-velocity and optical-reflectivity measurements using velocity interferometry, these experiments provide accurate equation-of-state data at extreme pressures (P > 1 Mbar) and temperatures (T > 0.5 eV). This paper reports on the absolute calibration of the streaked optical pyrometer (SOP) at the Omega Laser Facility. The wavelength-dependent system response was determined by measuring the optical emission from a National Institute of Standards and Technology–traceable tungsten-filament lamp through various narrowband (40 nm-wide) filters. The integrated signal over the SOP’s ~250-nm operating range is then related to that of a blackbody radiator using the calibrated response. We present a simple closed-form equation for the brightness temperature as a function of streak-camera signal derived from this calibration. As a result, error estimates indicate that brightness temperature can be inferred to a precision of <5%.

36 MATERIALS SCIENCE↗

Effects of laser-plasma instabilities on hydro evolution in an OMEGA-EP long-scale-length experiment

Laser-plasma instabilities and hydro evolution of the coronal plasma in an OMEGA EP long-scale-length experiment with planar targets were studied with particle-in-cell (PIC) and hydrodynamic simulations. Plasma and laser conditions were first obtained in a two-dimensional DRACO hydro simulation with only inverse-bremsstrahlung absorption. Using these conditions, an OSIRIS PIC simulation was performed to study laser absorption and hot-electron generation caused by laser-plasma instabilities (LPIs) near the quarter-critical region. The obtained PIC information was subsequently coupled to another DRACO simulation to examine how the LPIs affect the overall hydrodynamics. Lastly, the results showed that the LPI-induced laser absorption increased the electron temperature but did not significantly change the density scale length in the corona.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of cross-beam energy transfer in symmetric implosions on OMEGA using wavelength detuning

The effects of frequency detuning laser beams in direct-drive symmetric implosions were investigated with a 3-D cross-beam energy transfer (CBET) model. Our model shows that interactions between beams with relative angles between 45° and 90° are most significant for CBET in OMEGA direct-drive implosions. There is no net exchange in power between beams but there is significant redistribution of power from the ingoing central portion of the beam profile to the outgoing edge as it is exiting the plasma, reducing the total absorbed power. Furthermore, redistribution of laser power because of CBET increases the root-mean-square (rms) absorption nonuniformity by an order of magnitude. CBET mitigation by shifting relative wavelengths of three groups of laser beams fed by each of the different beamlines was modeled. At an on-target wavelength shift of Δλ ~ 10 Å, the total laser absorption was maximized, and the rms absorption nonuniformity was near minimum. In order to completely decouple the three groups of beams from each other requires wavelength shifts Δλ > 30 Å.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical quantification of shock-timing sensitivities for direct-drive inertial confinement fusion implosions on OMEGA

Using temporally shaped laser pulses, multiple shocks can be launched in direct-drive inertial confinement fusion implosion experiments to set the shell on a desired isentrope or adiabat. The velocity of the first shock and the times at which subsequent shocks catch up to it are measured through the VISAR diagnostic on OMEGA. Simulations reproduce these velocity and shock-merger time measurements when using laser pulses designed for setting mid-adiabat (α ~ 3) implosions, but agreement degrades for lower-adiabat (α ~ 1) designs. Several possibilities for this difference are studied: errors in placing the target at the center of irradiation (target offset), variations in energy between the different incident beams (power imbalance), and errors in modeling the laser energy coupled into the capsule. Simulation results indicate that shock timing is most sensitive to details of the density and temperature profiles in the coronal plasma, which influences the laser energy coupled into the target, and only marginally sensitive to target offset and beam power imbalance. A new technique under development to infer coronal profiles using x-ray self-emission imaging can be applied to the pulse shapes used in shock-timing experiments. In conclusion, this will help identify improved physics models to implement in codes and consequently enhance shock-timing predictive capability for low-adiabat pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of trends in experimental observables: Reconstruction of the implosion dynamics and implications for fusion yield extrapolation for direct-drive cryogenic targets on OMEGA

This paper describes a technique for identifying trends in performance degradation for inertial con finement fusion implosion experiments. It is based on reconstruction of the implosion core with a combination of low- and mid-mode asymmetries. This technique was applied to an ensemble of hydro-equivalent deuterium-tritium implosions on OMEGA that achieved inferred hot-spot pressures ≈56 ± 7 Gbar [S. Regan et al., Phys. Rev. Lett. 117, 025001 (2016)]. All the experimental observables pertaining to the core could be reconstructed simultaneously with the same combination of low and mid modes. This suggests that in addition to low modes, that can cause a degradation of the stagnation pressure, mid modes are present that reduce the size of the neutron and x-ray producing volume. The systematic analysis shows that asymmetries can cause an overestimation of the total areal density in these implosions. Finally, it is also found that an improvement in implosion symmetry resulting from correction of either the systematic mid or low modes would result in an increase of the hot-spot pressure from 56 Gbar to ≈ 80 Gbar and could produce a burning plasma when the implosion core is extrapolated to an equivalent 1.9 MJ symmetric direct illumination [A. Bose et al., Phys. Rev. E 94, 011201(R) (2016)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

First experiments on Revolver shell collisions at the OMEGA laser

The results of recent experiments on the OMEGA laser are presented, demonstrating the ablator-driver shell collision relevant to the outer two shells of the Revolver triple-shell inertial-confinement-fusion concept [K. Molvig et al., Phys. Rev. Lett. 116, 255003 (2016)]. These nested two-shell experiments measured the pre and postcollision outer-surface trajectory of the 7.19 g/cc chromium inner shell. Measurements of the shell trajectory are in excellent agreement with simulations; the measured outer-surface velocity was 7.52 ± 0.59 cm/μs compared to the simulated value of 7.27 cm/μs. Agreement between the measurements and simulations provides confidence in our ability to model collisions with features which have not been validated previously. Notable features include the absence of ~40 mg/cc foam between shells commonly used in double shell experiments, a dense (7.19 g/cc) inner shell representative of the densities to be used at full scale, approximately mass matched ablator payload and inner shells, and the inclusion of a tamping-layer-like cushion layer for the express purpose of reducing the transfer of high mode growth to the driver shell and mediation of the shell collision. These experiments test the modeling of the radiative heating, expansion, recompression, and acceleration of the chromium inner shell. Agreement of experimental measurements with simulation improves our confidence in the models used to design the Revolver ignition target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized x-ray sources for x-ray diffraction measurements at the Omega Laser Facility

The use of x-ray diffraction (XRD) measurements in laser-driven dynamic compression experiments at high-power laser facilities is becoming increasingly common. Diffraction allows one to probe in situ the transformations occurring at the atomic level at extreme conditions of pressure, temperature, and time scale. In these measurements, the x-ray source is generated by irradiation of a solid foil. Under certain laser drive conditions, quasimonochromatic He-α radiation is generated. Careful analysis of the x-ray source plasma spectra reveals that this radiation is not a single line emission and that monochromaticity is highly dependent on the laser irradiance. In this work, we analyze how the spectra emitted by laser-irradiated copper, germanium, and iron foils at the Omega Laser vary depending on different laser drive conditions and discuss the implications for XRD experiments.

47 OTHER INSTRUMENTATION↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗

An x-ray penumbral imager for measurements of electron–temperature profiles in inertial confinement fusion implosions at OMEGA

Hot-spot shape and electron temperature (T e ) are key performance metrics used to assess the efficiency of converting shell kinetic energy into hot-spot thermal energy in inertial confinement fusion implosions. X-ray penumbral imaging offers a means to diagnose hot-spot shape and T e , where the latter can be used as a surrogate measure of the ion temperature (T i ) in sufficiently equilibrated hot spots. We have implemented a new x-ray penumbral imager on OMEGA. We demonstrate minimal line-of-sight variations in the inferred T e for a set of implosions. Furthermore, we demonstrate spatially resolved T e measurements with an average uncertainty of 10% with 6 μm spatial resolution.

47 OTHER INSTRUMENTATION↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

A transmitted-beam diagnostic for the wavelength-tunable UV drive beam on OMEGA

A transmitted-beam diagnostic (P9TBD) was developed as part of a new experimental platform used to study laser–plasma interactions on OMEGA. Located in the opposing port to the wavelength-tunable (350 nm to 353 nm) UV drive beam, the P9TBD characterizes the beam after it propagates through an undersense plasma. The instrument consists of a large-aperture window that allows light to exit the target chamber and project onto a thin sheet of semi-transparent diffuser material. Light transmitted through the diffuser is recorded using a time-integrated camera and a fiber-optically coupled streaked spectrometer, providing measurements of the energy, power, fluence, polarization, and spectrum of the transmitted beam. Here, the diagnostic enables direct observation of a variety of cross-beam energy transfer phenomena, such as wavelength detuning, polarization effects, and gain saturation.

47 OTHER INSTRUMENTATION↗

Yield degradation due to laser drive asymmetry in D 3 He backlit proton radiography experiments at OMEGA

Mono-energetic proton radiography is a vital diagnostic for numerous high-energy-density-physics, inertial-confinement-fusion, and laboratory-astrophysics experiments at OMEGA. With a large number of campaigns executing hundreds of shots, general trends in D 3 He backlighter performance are statistically observed. Each experimental configuration uses a different number of beams and drive symmetry, causing the backlighter to perform differently. Here, we analyze the impact of these variables on the overall performance of the D 3 He backlighter for proton-radiography studies. This study finds that increasing laser drive asymmetry can degrade the performance of the D 3 He backlighter. The results of this study can be used to help experimental designs that use proton radiography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved imaging using Mn He- α x rays at OMEGA EP

In this paper, we report on a crystal based x-ray imaging system fielded at the OMEGA EP laser facility. This new system has a pointing accuracy of +/100 μm, a temporal resolution down to 100 ps (depending on backlighter characteristics), variable magnification, and a spatial resolution of 21.9 µm at the object plane at a magnification of 15×. The system is designed to use a crystal along the crystal plane that satisfies the Bragg condition for the x ray of interest. The thin crystal is then bent into a spherical geometry and attached to a glass backing substrate to hold it in the diagnostic, and the x rays are imaged onto a charge coupled device. We report on data acquired with the new Los Alamos National Laboratory supplied spherical quartz crystal to image the Mn He-α 6.15 keV line emission.

Fiedler Kawaguchi, C. (ORCID:0000000175522370)↗

Aerosol jet printed 3 omega sensors for thermal conductivity measurement

The 3 omega (3ω) method is a trusted technique for measuring thermal conductivity—a fundamental material property of critical importance in a broad range of applications. However, traditional 3ω sensor processing requires some form of physical vapor deposition, such as metal evaporation or sputtering. These 3ω sensor deposition techniques limit the materials and sample sizes applicable to the 3ω method. This work demonstrates an aerosol jet printing method to directly print silver 3ω sensors that yield accurate temperature-dependent measurement up to 300 °C on materials with thermal conductivity ranging from 1 to 150 W/m K. The interrelationship between printed sensor geometry, sensor thermal stability, and applicability to the 3ω method is examined. Thermal conductivity measurement with 3ω sensors conventionally sintered at 300 °C agrees to independent laser flash measurement within 4% from room temperature to 150 °C. An unconventional rapid high-temperature sintering method is shown to produce sensors that agree within 3% of the laser flash measurements from room temperature to 300 °C. The rapid sintering profiles also reduced the sensor–substrate thermal boundary resistance of the printed sensors by as much as 88%. The direct printing of 3ω sensors creates opportunities for measurement of thermal transport properties in applications previously inapplicable to the 3ω method.

47 OTHER INSTRUMENTATION↗

Extension of charged-particle spectrometer capabilities for diagnosing implosions on OMEGA, Z, and the NIF

New designs and a new analysis technique have been developed for an existing compact charged-particle spectrometer on the NIF and OMEGA. The new analysis technique extends the capabilities of this diagnostic to measure arbitrarily shaped ion spectra down to 1 MeV with yields as low as 10 6 . Three different designs are provided optimized for the measurement of DD protons, T 3 He deuterons, and 3 He 3 He protons. The designs are highly customizable, and a generalized framework is provided for optimizing the design for alternative applications. Additionally, the understanding of the detector’s response and uncertainties is greatly expanded upon. A new calibration procedure is also developed to increase the precision of the measurements.

47 OTHER INSTRUMENTATION↗