Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Sputtering in mercury ion thrusters

Ground-based tests of Hg ion thrusters have identified sputter erosion of thruster components as one of the main life limiting phenomena. Subsequent measurements have revealed that sputtering rates can be affected by background gases at pressures as low as 10 to the -10th torr. With the recent interest in thin film technology, sputtering in the presence of reactive gases has been studied in great detail. This paper presents the results of many of those studies and applies them to the sputtering of electric thrusters. A model, which assumes that chemisorption is the dominant mechanism, is applied to the sputtering rate measurements of the screen grid of a 30-cm thruster in the presence of nitrogen. The model utilizes inputs from a variety of experimental and analytical sources. The model of environmental effects on sputtering was applied to thruster conditions of low discharge voltage and a discussion of the comparison of theory and experiment is presented.

Mantenieks, M. A.↗

Identification of HgO/x/ species by matrix isolation spectroscopy

The condensation of Hg atoms in an ozone-doped argon matrix gas with irradiation from a medium-pressure mercury arc lamp at 10 K resulted in the formation of several trapped HgO(x) species. Tentative identification of HgO has been made from absorption bands appearing in the visible and IR regions of the spectrum based on (O-16)2 and (O-18)2 isotope studies. The following spectroscopic constants were obtained: nu(00) = 14634 cm, nu(1) = 548 cm, and nu(11) = 676 cm. Some qualitative evidence was obtained for the existence of HgO2.

Butler, R.↗

The factors influencing the formation of Li2CO3 from LiOH and CO2

LiOH is used to remove CO2 from the atmosphere in three environmental control systems of the Shuttle program, and the investigation of the performance dependent parameters for the CO2 reaction with LiOH is reported. Emphasis is placed on LiOH quality acceptance criteria and on identifiying the relationships between the reaction rate and the following independent parameters: temperature, CO2 partial pressure (PP), H2O concentration in the solid, amount of remaining LiOH and the porosity of the LiOH pellets. Results showed that the reaction rate is proportional to the CO2 PP for PP at least as high as 40 mm Hg (5330 N/sq m). It is also noted that a significant difference in the reactivity of wet and dry LiOH was not detected.

Davis, S. H., Jr.↗

Progress report on the ATMOS sensor - Design description and development status

The Atmospheric Trace Molecule Spectroscopy program is a multiflight shuttle borne investigation designed to determine, on a global scale, the compositional structure and spatial variability of the upper atmosphere using the technique of high resolution infrared absorption spectroscopy. The measurement approach is based on an advanced Fourier Transform Spectrometer capable of obtaining high sensitivity spectral measurements of the atmosphere over a wide spectral region (625-5000 kaysers; 2-16 microns) at high spectral resolution (0.01 kaysers) and vertical height spatial resolution (2 km). Additional elements of the sensor system include a suntracker, a telescope, a mechanically cooled (Hg,Cd)Te detector, and a data handling subsystem with a 16 Mbit/s PCM output. A description is given of the sensor design, including performance predictions, followed by a brief summary of the current technical status of the development effort.

Morse, P. G.↗

Hot-film static-pressure probe for surveying flow fields

A static pressure probe employing hot-film sensors has been developed for the rapid measurement of the static pressure fields surrounding analytic shapes in hypersonic flows. The hot-film probe is a modification of the standard static pressure probe, consisting of a front hot-film sensor operated as a resistance thermometer, a rear sensor operated at an overheat ratio of 1.5 to 1.8 and a small sonic orifice installed inside the tubing of a conventional device. The probe has been calibrated in helium and air over a range of temperatures and pressures in a bell jar apparatus, with a repeatability of the data to within + or - 0.015 mm Hg. Comparative tests of the hot-film and conventional static pressure probes in a hypersonic helium wind tunnel at Mach 20 and various Reynolds numbers have indicated the settling time of the hot-film probe to be on the order of milliseconds, as compared with 30 sec for the conventional probe. The pressures measured by the two probes were found to be within 10% of each other. Although the hot-film probe makes flow-field static pressure surveys more practical in blowdown hypersonic wind tunnels, viscous and flow angle effects still must be assessed under the conditions of use.

Ashby, G. C., Jr.↗

Characterization of superfluid helium transfer

The friction factor and steady state flow rate of superfluid helium (He II) are measured, with the driving pressure difference generated by the saturated vapor pressure and a small hydrostatic pressure head. The temperature ranged from 1.5 K to the transition temperature of 2.17 K. Three different lengths and two different internal diameters were used for the stainless steel transfer tubes, and the transfer of liquid helium (He I) was investigated with the same apparatus for comparison. It was found that the friction factor of He II is greater than that of He I for pressure differences greater than 20 mm Hg, and smaller below that magnitude.

Yang, L. C.↗

Performance capabilities of the 8-cm Mercury ion thruster

The paper presents an initial characterization of the performance capabilities and constraints of the 8-cm Hg ion thruster system with a view to evaluating its application to large space system propulsion requirements. With minor thruster modifications, the thrust was increased by about a factor of four, while the discharge voltage was reduced from 39 to 22 volts. The thruster was operated over a range of specific impulse of 1950 to 3040 seconds, and a maximum total efficiency of about 54% was attained at a discharge voltage of 24 volts and thruster input power of 0.49 kW.

Mantenieks, M. A.↗

Extended operating range of the 30-cm ion thruster with simplified power processor requirements

A 30-cm-diameter Hg ion thruster similar in design to the J-series thruster was operated at fixed conditions with only five power supplies and was throttled over the baseline power range with six supplies. An analysis of the functional model power processor showed that the component mass and parts count would be reduced by about 14 and 35% respectively, and the electrical efficiency would be increased about 1.5% by replacing power supplies with relays. By introducing new circuit designs, additional reductions in the component mass and parts, as well as an increase in electrical efficiency would be expected. The impact on thruster performance of reducing the number of power supplies was to lower the propellant utilization efficiency about 1.0% and raise the electrical efficiency values from 0.2 to 1.3% over the throttle range.

Rawlin, V. K.↗

Exercise training hypotension - Implications for plasma volume, renin, and vasopressin

The relation of changes in plasma volume, plasma renin activity and arginine vasopressin to changes in resting blood pressure during exercise training is investigated. Resting supine, sitting, and standing systolic and fifth-phase diastolic blood pressures were measured in ten men before and after an eight-day training period on a cycle ergometer in either a hot (39.8 C) or cool (23.8 C) environment, and compared with plasma volume, renin and vasopressin levels, heart rates, maximal oxygen uptakes, rectal temperatures and sweat rates. Following acclimatization, resting supine and sitting diastolic pressures are observed to decrease by 6 and 9 mm Hg, respectively, while no significant changes are found in the diastolic pressures of the control group or the systolic pressures of either group. Resting plasma volume is found to increase by 12.2% in the controls and by 17.6% after acclimatization following the exercise training. Results suggest that the resting hypotension produced is not attributable to changes in resting plasma volume, renin or vasopressin, although heat acclimatization, which leads to large decreases in plasma volume and increases in vasopressin and renin activity, may be useful in the treatment of hypertension.

Greenleaf, J. E.↗

Time-resolved spectroscopy of the Mercury 6 3P1 state

The time-resolved fluorescence was observed from the Hg 6 3P1 state under the influence of the earth's magnetic field and with applied fields of up to 14 G. Modulation of the fluorescence decay signal was observed as a function of both time and space and can be interpreted in terms of a classical precession of the excited atom about the magnetic field or as quantum beats resulting from interference between coherently populated Zeeman sublevels. This modulation was studied for each of the five resolvable components of the hyperfine structure separately. The fluorescence from the even isotopes was determined to be almost completely modulated while the fluorescence from the odd isotopes was only partially modulated. The frequency of modulation of the fluorescence from the mercury-202 isotope was observed as a function of the applied magnetic field and a value for the Lande factor of 1.46 + or - 0.03 was obtained. This is within experimental error of the accepted value of 1.486. In addition, the frequency of modulation as a function of applied magnetic field was determined for each of the three resolvable components with more than one contributing isotopic hyperfine line. An investigation of the effect of radiation trapping on the degree modulation was also made.

Halstead, J. A.↗

Fabricating Thin-Film High-Temperature Thermoset Resins

To prepare an epoxy thin film, quantity of uncured epoxy to be cast placed in vacuum oven and heated to melting temperature. Vacuum of about 30 mm Hg is applied to deaerate epoxy charge. Pressure is cycled with each foaming until all air and excess volatiles are revoved. thermoset (cross-linked) resin is cast between thin, flexible, releasing substrate films. Films less than 0.025 mm in thickness are made routinely with this facility.

Dickerson, G. E.↗

Advanced methods for preparation and characterization of infrared detector materials

Differential thermal analysis data were obtained on mercury cadmium telluride alloys in order to establish the liquidus temperatures for the various alloy compositions. Preliminary theoretical analyses was performed to establish the ternary phase equilibrium parameters for the metal rich region of the phase diagram. Liquid-solid equilibrium parameters were determined for the pseudobinary alloy system. Phase equilibrium was calculated and Hg(l-x) Cd(x) Te alloys were directionally solidified from pseudobinary melts. Electrical resistivity and Hall coefficient measurements were obtained.

Lehoczky, S. L.↗

Preprototype independent air revitalization subsystem

The performance and maturity of a preprototype, three-person capacity, automatically controlled and monitored, self-contained independent air revitalization subsystem were evaluated. The subsystem maintains the cabin partial pressure of oxygen at 22 kPa (3.2 psia) and that of carbon dioxide at 400 Pa (3 mm Hg) over a wide range of cabin air relative humidity conditions. Consumption of water vapor by the water vapor electrolysis module also provides partial humidity control of the cabin environment. During operation, the average carbon dioxide removal efficiency at baseline conditions remained constant throughout the test at 84%. The average electrochemical depolarized concentrator cell voltage at the end of the parametric/endurance test was 0.41 V, representing a very slowly decreasing average cell voltage. The average water vapor electrolysis cell voltage increased only at a rate of 20 mu/h from the initial level of 1.67 V to the final level of 1.69 V at conclusion of the testing.

Schubert, F. H.↗

Ultraviolet spectroscopy of F and G supergiants with IUE. II - The hot companions of HR 2786 and HR 2859

Hot companion stars in two binary systems are analyzed by means of IUE low-dispersion spectra. HR 2859B is found to be a B2 IV or V star, and analysis of ultraviolet to near-infrared photometry indicates the primary to be an early G star only one magnitude brighter in V with a magnitude of -4.0. A third star probably associated with this system was classified B9p Hg a probable visual absolute magnitude of about -1.6 is obtained for it. HR 2786 is now confirmed to have a hot secondary, for which a spectral class of B9-9.5 is obtained. With an assumed luminosity for this component, the G2 Ib primary then has a magnitude of -3.8.

Parsons, S. B.↗

Extended Performance 8-cm Mercury Ion Thruster

A slightly modified 8-cm Hg ion thruster demonstrated significant increase in performance. Thrust was increased by almost a factor of five over that of the baseline thruster. Thruster operation with various three grid ion optics configurations; thruster performance as a function of accelerator grid open area, cathode baffle, and cathode orifice size; and a life test of 614 hours at a beam current of 250 mA (17.5 mN thrust) are discussed. Highest thruster efficiency was obtained with the smallest open area accelerator grid. The benefits in efficiency from the low neutral loss grids were mitigated, however, by the limitation such grids place on attainable ion beam current densities. The thruster components suffered negligible weight losses during a life test, which indicated that operation of the 8-cm thruster at extended levels of thrust and power is possible with no significant loss of lifetime.

Mantenieks, M. A.↗

J series thruster isolator failure analysis

Three Hg propellant isolators (two cathode and one main) failed during testing in the Mission Profile Life Test. These failures involved contamination of the surface of the alumina insulating body which resulted in heating of the vaporizer by leakage current from the high voltage supply, with subsequent loss of propellant flow rate control. Failure analysis of the isolators showed the surface resistance was temperature dependent and that the alumina could be restored to its original insulating state by grit blasting the surface. The contaminant was identified as carbon and the most likely sources identified as ambient facility hydrocarbons, directed back-sputtered facility materials, and outgassing from organic insulating materials within the thruster envelope. Methods to eliminate contamination from each of these sources are described.

Campbell, J. W.↗

A comparison of limb plethysmograph systems proposed for use on the Space Shuttle

Comparisons of a Whitney mercury-filled double-stranded strain gauge with two plethysmographs proposed for Shuttle use - an ultrasound and an impedance plethysmograph - were performed on 20 subjects. An occlusive thigh pressure cuff, inflated to 50 mm Hg, caused partial venous occlusion and subsequent blood pooling distal to the cuff. The average maximum volume changes observed in the Whitney/ultrasound test were 2.07% and 3.35%, respectively, and 2.12% and 2.53% for the Whitney/Impedance comparison. Applying the ratio of the maximum volume changes to the gain of each test system caused the impedance and ultrasound volume change determinations to be essentially identical to the Whitney gauge. The three different limb parameters measured result in significant magnitude differences but the three systems track their respective changes identically.

Levitan, B. M.↗