Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Real-time Anomaly Detection for Liquid Argon Time Projection Chambers

We present a real-time anomaly detection framework for liquid argon time projection chambers (LArTPCs), targeting applications in particle physics experiments such as the Short Baseline Near Detector (SBND) or the future Deep Underground Neutrino Experiment (DUNE). These experiments employ detectors that generate and stream high-resolution but sparse images of neutrino and other particle interactions. Our approach utilizes anomaly detection with autoencoders, compressed through knowledge distillation (KD), to enable the detection of anomalous signals in the data through efficient inference on resource-constrained hardware. The framework is targeted for deployment on computing platforms equipped with field-programmable gate arrays (FPGAs), GPUs, or CPUs, allowing low-latency selection of relevant activity directly from the raw detector data stream. We demonstrate that our approach is suitable for the detection and localization of anomalously "high-multiplicity" activity, and outline promising applications for LArTPC online data filtering and triggering.

FOS: Physical sciences↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Gravitational wave timing array

We describe the design of a gravitational wave timing array, a novel scheme that can be used to search for low-frequency gravitational waves by monitoring continuous gravitational waves at higher frequencies. We show that observations of gravitational waves produced by Galactic binaries using a space-based detector like LISA provide sensitivity in the nanohertz to microhertz band. While the expected sensitivity is several magnitudes worse than what can be achieved by pulsar timing arrays, it supplements other recent proposals for gravitational wave searches in the microhertz regime. This regime is below the frequencies to which LISA is directly sensitive, and above the frequency range generally targeted by pulsar timing array searches. Here, the low-frequency extension of sensitivity does not require any experimental design change to space-based gravitational wave detectors, and can be achieved with the data products that would already be collected by them.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational waves from global cosmic strings and cosmic archaeology

Global cosmic strings are predicted in many motivated extensions to the Standard Model of particle physics, with close connections to axion dark matter physics. Recent studies suggest that, although subdominant relative to Goldstone emission, gravitational wave (GW) signals from global strings can be detectable with current and planned GW detectors such as LIGO, LISA, DECIGO/BBO, ET/CE and AEDGE/AION, as well as pulsar timing arrays such as PPTA, NANOGrav and SKA. This work is an extensive, updated study on GWs from a global cosmic string network, taking into account of the most recent developments related to the subject. The main analysis is based on the analytical Velocity-dependent One-Scale (VOS) model calibrated with recent simulation results, which provides a generic protocol for such calculations with details given. We also demonstrate how the GW signal can be influenced with variations to the baseline model: this includes considering the uncertainties of model parameters and the potential deviation from the conventional VOS model prediction (i.e. the scaling behavior) as suggested by some of the recent simulation results. Furthermore, we investigated in detail the effect of a non-standard cosmology (e.g. early matter domination or kination) or new particle species on the GW signals from global strings. We demonstrate that the frequency spectrum of GW background from global cosmic strings can be used to probe the cosmic history prior to the Big Bang nucleosynthesis (BBN) (i.e. the primordial dark age) up to a temperature of T ~ 10 8 GeV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precise measurements of branching fractions for $ {\mathrm{D}}_{\mathrm{s}}^{+} $ meson decays to two pseudoscalar mesons

We measure the branching fractions for seven $D$$^{+}_{s}$ two-body decays to pseudo-scalar mesons, by analyzing data collected at √s = 4.178 ~ 4.226 GeV with the BESIII detector at the BEPCII collider. The branching fractions are determined to be $$ {\displaystyle \begin{array}{c}\mathcal{B}\left({D}_s^{+}\to {K}^{+}\eta \hbox{'}\right)=\left(2.68\pm 0.17\pm 0.17\pm 0.08\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to \eta \hbox{'}{\pi}^{+}\right)=\left(37.8\pm 0.4\pm 2.1\pm 1.2\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}^{+}\eta \right)=\left(1.62\pm 0.10\pm 0.03\pm 0.05\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to \eta {\pi}^{+}\right)=\left(17.41\pm 0.18\pm 0.27\pm 0.54\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}^{+}{K}_S^0\right)=\left(15.02\pm 0.10\pm 0.27\pm 0.47\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}_S^0{\pi}^{+}\right)=\left(1.109\pm 0.034\pm 0.023\pm 0.035\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}^{+}{\pi}^0\right)=\left(0.748\pm 0.049\pm 0.018\pm 0.035\right)\times {10}^{-3},\end{array}} $$ B D s + → K + η ' = 2.68 ± 0.17 ± 0.17 ± 0.08 × 10 - 3 , B D s + → η ' π + = 37.8 ± 0.4 ± 2.1 ± 1.2 × 10 - 3 , B D s + → K + η = 1.62 ± 0.10 ± 0.03 ± 0.05 × 10 - 3 , B D s + → η π + = 17.41 ± 0.18 ± 0.27 ± 0.54 × 10 - 3 , B D s + → K + K S 0 = 15.02 ± 0.10 ± 0.27 ± 0.47 × 10 - 3 , B D s + → K S 0 π + = 1.109 ± 0.034 ± 0.023 ± 0.035 × 10 - 3 , B D s + → K + π 0 = 0.748 ± 0.049 ± 0.018 ± 0.035 × 10 - 3 , where the first uncertainties are statistical, the second are systematic, and the third are from external input branching fraction of the normalization mode $ {D}_s^{+} $ D s + → K + K - π + . Precision of our measurements is significantly improved compared with that of the current world average values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanosecond anomaly detection with decision trees and real-time application to exotic Higgs decays

Abstract We present an interpretable implementation of the autoencoding algorithm, used as an anomaly detector, built with a forest of deep decision trees on FPGA, field programmable gate arrays. Scenarios at the Large Hadron Collider at CERN are considered, for which the autoencoder is trained using known physical processes of the Standard Model. The design is then deployed in real-time trigger systems for anomaly detection of unknown physical processes, such as the detection of rare exotic decays of the Higgs boson. The inference is made with a latency value of 30 ns at percent-level resource usage using the Xilinx Virtex UltraScale+ VU9P FPGA. Our method offers anomaly detection at low latency values for edge AI users with resource constraints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

19 Ne level structure for explosive nucleosynthesis

Ne 19 is an important isotope in nuclear astrophysics due to its role in both the F 18 ( p , α ) O 15 and O 15 ( α , γ ) Ne 19 reactions in novae and Type I x-ray bursts, respectively. The energy levels of Ne 19 near the α and proton thresholds ( S α = 3529 keV, S p = 6410 keV) correspond to resonances in both of these reactions. Previous measurements to study the structure of Ne 19 have focused on both regions in an effort to constrain these reaction rates. Discrepancies in the energies, spins, and parities for levels in Ne 19 from previous measurements contribute to the reaction-rate uncertainties. Gamma rays from the depopulation of excited states in Ne 19 were measured to reduce the level-energy uncertainties and inconsistencies in previous spin-parity assignments.The F 19 ( He 3 , t ) Ne 19 reaction was used to elucidate the structure of Ne 19 levels up to E x = 6.9 MeV. The reaction products were measured using Gammasphere ORRUBA: Dual Detectors for Experimental Structure Studies—a coupling of the Oak Ridge Rutgers University Barrel Array and Gammasphere at Argonne National Laboratory. Tritons produced in the reaction were measured in coincidence with γ rays from the deexcitation of Ne 19 energy levels. Previously unobserved transitions allowed for discrepancies in the resonance properties relevant to these two reactions to be resolved. In total, 41 transitions from 21 energy levels were measured in Ne 19 , with 21 of those transitions being previously unobserved. Of particular importance, transitions from two 3 / 2 + states with energies of 6423(3) and 6441(3) keV, crucial for accurate estimations of the F 18 ( p , α ) O 15 reaction rate, were found. Energies and spin-parities of important energy levels near the proton and α thresholds were measured and some of the discrepancies in previous measurements were resolved. Overall, measurement of the two near-threshold 3 / 2 + states reduced the calculated upper limit of the F 18 ( p , α ) O 15 reaction rate by factors of 1.5–17 in the nova temperature range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The background model of the CUPID-Mo $0\nu\beta\beta$ experiment

CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation 0vββ decay experiment, CUPID. It consisted of an array of 20 enriched Li 2 100 MoO 4 bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the 2vββ decay and other processes with high precision. We also measure the radio-purity of the Li 2 100 MoO 4 crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7 $^{+0.9}_{-0.8}$ (stat) $^{+1.5}_{-0.7}$ (syst) x 10 -3 counts/ ΔE FWHM / mol iso / year the lowest in a bolometric Ovββ decay experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of CMOS Sensors for HEP with a US-based foundry

We will present a program to establish the first development and manufacturing of HEP-specific sensors monolithically integrated into a standard CMOS process using a US-based foundry. In collaboration with several US universities the project aims to develop Monolithic Active Pixel Sensors (MAPS) designs implemented in the 90 nm technology node, including simple test structures and multi-pixel arrays, and monolithic CMOS sensors with readout integrated circuits, perform detailed characterization of the detector prototypes and quantify their performance for HEP applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗