Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control of Distributed Energy Resources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Valuation of Distributed Wind in an Isolated System

Remote communities are increasingly adopting renewable energy, such as wind, as they transition away from diesel energy generation. It is important to understand the benefits and costs of wind energy to isolated systems so that decision-makers can optimize their choices in these communities. There are few examples of valuation of wind energy as a distributed resource and numerous differences in valuation approaches, especially in the inclusion of environmental and economic impacts. We apply a distributed wind valuation framework to calculate the benefits and costs of wind in St. Mary’s, Alaska, to the local electric cooperative and to society, finding that the project does not have a favorable benefit-to-cost ratio unless societal benefits are included, in which case the benefit-to-cost ratio is nearly double. Government funding is important to reducing the initial capital expenditures of this wind project and will likely be the case for projects with similar characteristics. Additional fuel savings benefits are potentially possible for this project through technological additions such as energy storage and advanced controls.

17 WIND ENERGY↗

Federated Architecture for Secure and Transactive Distributed Energy Resource Management Solutions (FAST-DERMS)

This document provides system-level specifications for a federated architecture for secure and transactive distributed energy resource management solutions (FAST-DERMS), presents a solution, and describes operational concepts for the proposed solution. FAST-DERMS enables the provision of reliable, resilient, and secure transmission and distribution (T&D) grid services through the scalable aggregation and near-real-time management of utility-scale and small-scale distributed energy resources (DERs). We first present the principles and objectives of FAST-DERMS. Then, after discussing important system concepts, we present the specifications for FAST-DERMS and a solution that employs a distributed and federated control methodology in which the DERs connected to a single point of common coupling with the rest of the system, such as individual substations, are optimized coordinately to provide system-level grid services. FAST-DERMS aims to aggregate and coordinate the operations of DERs to support T&D grid operations. The key optimization and control component of this FAST-DERMS reference implementation is a flexible resource scheduler (FRS) that aggregates the DERs within a substation service area. These FRSs operate at the substation level and perform constrained economic dispatch of DERs, either directly or through a transactive market or aggregator, as shown in Figure ES-1. An FRS Coordinator at the distribution system operator (DSO) level aggregates distribution substations operated by FRSs and interfaces with the transmission system operator (TSO) to provide transmission services. FAST-DERMS also allows for the integration of the FRS Coordinator with an existing distribution utility management system that could be employed by the DSO to enhance distribution grid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Application of DLT cybersecurity stack to TES applications for a scalable, cybersecure, and interoperable future

Transactive Energy Systems (TES) are expected to improve upon existing grid operations and capabilities by enabling the integration of traditional grid resources with distributed energy resources (DER). Distributed Ledger Technology or DLT (e.g., blockchain) presents itself as a viable instrument to support decentralized, autonomous, and tamper-evident applications, which can be leveraged within TES's ecosystem. DLTs can provide pertinent security controls including access controls, data immutability, and traceability in addition to other well-known advantages such as decentralization and scalability. This work demonstrates the DLT Cybersecurity stack and its applicability to TES-based use-cases/applications. The seven-layer DLT cybersecurity stack is a DLT-agnostic framework that can quickly be used to classify and group the individual needs of an application into the different processing and cybersecurity layers offered by a DLT using a common taxonomy and an architectural mapping framework. This enables application engineers to demystify and strengthen the overall security aspects of their systems while maintaining an open perspective towards features and drawbacks that may hinder their performance in real-world scenarios. The paper leverages the work performed by the IEEE P2418.5 - Blockchain for Energy Standards working group.

Blockchain, blockchain interoperability, Cybersecu↗

Distributed Minimization of the Power Generation Cost in Prosumer-Based Distribution Networks: Preprint

Traditionally, electrical power was generated in big power plants. The cost of producing energy was related to the cost of fuel, e.g., carbon or gas, and by the cost of maintaining the power plants. With the advent of distributed energy resources, power can be produced directly at the edge of the electrical network by a new type of agents: the prosumers. Prosumers are entities that both consume and generate power, e.g., by means of photovoltaic panels. The cost of the power produced by prosumers is no longer related to fuel consumption since energy coming from distributed generators is essentially free. Rather, the cost is related to the remuneration that is due to the prosumers for the services they provide. The proposed control strategy minimizes the active power generation cost in the aforementioned scenario. The control scheme requires that the prosumers measure their voltage and then adjust the amount of injected power, according to a continuous time feedback control law that is indeed a projected gradient descent strategy. Simulations are provided in order to illustrate the algorithm behavior.

distributed control↗

Data-driven quantum approximate optimization algorithm for power systems

Abstract Quantum technology provides a ground-breaking methodology to tackle challenging computational issues in power systems. It is especially promising for Distributed Energy Resources (DERs) dominant systems that have been widely developed to promote energy sustainability. In those systems, knowing the maximum sections of power and data delivery is essential for monitoring, operation, and control. However, high computational effort is required. By leveraging quantum resources, Quantum Approximate Optimization Algorithm (QAOA) provides a means to search for these sections efficiently. However, QAOA performance relies heavily on critical parameters, especially for weighted graphs. Here we present a data-driven QAOA, which transfers quasi-optimal parameters between weighted graphs based on the normalized graph density. We verify the strategy with 39,774 expectation value calculations. Without parameter optimization, our data-driven QAOA is comparable with the Goemans-Williamson algorithm. This work advances QAOA and pilots its practical application to power systems in noisy intermediate-scale quantum devices.

Jing, Hang (ORCID:0000000256343489)↗

Adaptive Control Algorithm to Adjust Settings in Photovoltaic Inverters for Electric Grid Cybersecurity (DERAC) v0.1

Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability in real-time. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. This repository provides code to simulate the algorithm in experiments on the IEEE 37 node test feeder.

Arnold, Daniel↗

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗

Common Information Model for Electromagnetic Transients (CIM for EMT): CRADA 533 [Abstract only}

The control and protection functions of inverter-based resources (IBR) have raised concerns with bulk system reliability. Most of the current interest lies with solar photovoltaic generation but increasing amounts of storage would pose the same risks. Newer North American Electric Reliability Corporation (NERC) guidelines call for electromagnetic transient (EMT) studies of IBR and recommend that transmission operators collect distributed energy resource (DER) data to support such modeling. IEEE Standard P2800.1 is defining tests for model parameterization, so good model data should become available from inverter vendors. (EMT studies also apply to large power transformer reliability, and transformer vendors can provide EMT models.) Utilities don’t currently have the rest of the bulk system represented for EMT studies at large scale. An International Electrotechnical Commission (IEC) standard Common Information Model (CIM) provides a way of supporting these detailed models from physical asset data, e.g., conductors, towers, transformer data sheets, control block diagrams, while avoiding software vendor lock-in. CIM-for-EMT, with proposed schema extensions and open-source converters, provides a way to exchange EMT data between organizations and tools. This project leverages Office of Electricity (OE) funding of CIM-for-EMT code base through the GridAPPS-DTM project, and of GridPACKTM (parallelized transmission solver), for interoperability testing in CIM-for-EMT. The project also leverages partner PGSTech investments in EMTP® interoperability with CIM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parallel derivative-free optimization for simulation-based design of behind-the-meter energy systems

In this work, the integrated design and dispatch of behind-the-meter or distributed resources (e.g. stationary battery storage and solar PV generation) is considered. A simulation-based framework is employed, generating high-fidelity results with closed-loop predictive control at a fine resolution, at the expense of high computational cost (several minutes to a few hours per design point). To address this challenge, parallel derivative-free design methods are considered. Four methods are compared, including state-of-the-art surrogate-based methods (Radial-Basis Functions and Gaussian processes) and sampling strategies, an evolutionary-based method, and a simple sequential grid refinement method. As a case study, two types of design problem with increasing complexity are considered, namely, the design of behind-the-meter resources (three design variables) and the inclusion of grid capacity (four design variables). The second yields a constrained design problem for which violations can only be determined after solving the computationally expensive simulation. For the three-dimensional case, all methods present a good performance, achieving a solution within 1% of the optimum after the first iteration, with the sequential grid refinement exhibiting the fastest convergence and achieving the best final objective value. This indicates that the parallel evaluation of multiple sampling points may be more important than the choice of method for small decision spaces. For the four-dimensional constrained case, the Genetic Algorithm presents the best tradeoff between performance and computational effort, while the rough objective function terrain generated by constraint violation penalties reduces the performance of surrogate-based methods. Contour plots with flat regions indicate flexibility in the optimal design and highlight the importance of characterizing the solution space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed ADMM Using Private Blockchain for Power Flow Optimization in Distribution Network With Coupled and Mixed-Integer Constraints

The optimization problem for scheduling distributed energy resources (DERs) and battery energy storage systems (BESS) integrated with the power grid is important to minimize energy consumption from conventional sources in response to demand. Conventionally this optimization problem is solved in a centralized manner, limiting the size of the problem that can be solved and creating a high communication overhead because all the data is transferred to the central controller. These limitations are addressed by the proposed distributed consensus-based alternating direction method of multiplier (DC-ADMM) optimization algorithm, which decomposes the optimization problem into subproblems with private cost function and constraints. The distribution feeder is partitioned into low coupling subnetworks/regions, which solves the private subproblem locally and exchanges information with the neighboring regions to reach consensus. The relaxation strategy is employed for mixed-integer and coupled constraints introduced in the optimal power flow (OPF) problem by stationary and transportable BESS because DC-ADMM convergence is only guaranteed for strict convex problems. The information exchange and synchronization between subnetworks/regions are vital for distributed optimization. In this work, both of these aspects are addressed by the blockchain. The smart contract deployed on the blockchain network acts as a mediator for secure data exchange and synchronization in distributed computation. The blockchain-based distributed optimization problem’s effectiveness is tested for a 0.5-MW laboratory microgrid for one hour ahead and day-ahead for the IEEE 123-bus and EPRI J1 test feeders, and results are compared with a centralized solution.

25 ENERGY STORAGE↗

Forest stand and canopy development unaltered by 12 years of CO2 enrichment*

Abstract Canopy structure—the size and distribution of tree crowns and the spatial and temporal distribution of leaves within them—exerts dominant control over primary productivity, transpiration and energy exchange. Stand structure—the spatial arrangement of trees in the forest (height, basal area and spacing)—has a strong influence on forest growth, allocation and resource use. Forest response to elevated atmospheric CO2 is likely to be dependent on the canopy and stand structure. Here, we investigated elevated CO2 effects on the forest structure of a Liquidambar styraciflua L. stand in a free-air CO2 enrichment experiment, considering leaves, tree crowns, forest canopy and stand structure. During the 12-year experiment, the trees increased in height by 5 m and basal area increased by 37%. Basal area distribution among trees shifted from a relatively narrow distribution to a much broader one, but there was little evidence of a CO2 effect on height growth or basal area distribution. The differentiation into crown classes over time led to an increase in the number of unproductive intermediate and suppressed trees and to a greater concentration of stand basal area in the largest trees. A whole-tree harvest at the end of the experiment permitted detailed analysis of canopy structure. There was little effect of CO2 enrichment on the relative leaf area distribution within tree crowns and there was little change from 1998 to 2009. Leaf characteristics (leaf mass per unit area and nitrogen content) varied with crown depth; any effects of elevated CO2 were much smaller than the variation within the crown and were consistent throughout the crown. In this young, even-aged, monoculture plantation forest, there was little evidence that elevated CO2 accelerated tree and stand development, and there were remarkably small changes in canopy structure. Questions remain as to whether a more diverse, mixed species forest would respond similarly.

59 BASIC BIOLOGICAL SCIENCES↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗