At least 469 records · Page 26

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

Rigid-flexible coupling multi-body dynamics modeling of a semi-submersible floating offshore wind turbine

A 14-degree-of-freedom (14-DOF) flexible multibody dynamics model is developed and verified for a semi-submersible floating offshore wind turbine (FOWT). The model considers the coupled dynamics of the platform, tower, nacelle, blades, and mooring subjected to external wind and wave loads. The platform is simplified as a rigid body connected to the seabed by the mooring system. The tower and blade are modeled as flexible cantilever beams. The energy method is used to derive the governing equations of motion, where the kinetic energy, potential energy, and work done by external wind-wave forces are all deduced in a global coordinate system. The 5-MW baseline semi-submersible FOWT is used to verify the derived model against the results simulated from FAST developed by the US National Renewable Energy Laboratory (NREL) at two scenarios: free decay state and different wind-wave load cases. Results show that the established FOWT model can well reflect the vibration characteristics of FAST model. The application of the model to the control of platform pitch with a tuned mass damper is studied. Furthermore, the simplified model could provide a low-order method for the structural dynamics analysis and advanced vibration control design for the multi-body components of the semi-submersible FOWT in the future.

17 WIND ENERGY↗

Neural-Network-Enhanced COTSIM: Advancing Predictive Capabilities for Fast DIII-D Simulations

Sustaining fusion reactions in tokamaks requires heating plasma to thermonuclear temperatures while maintaining confinement and stability. Neutral beam injection (NBI) provides heating, current drive, torque, and fueling, while electron cyclotron (EC) waves are widely used for heating and current drive; together, these actuators shape the plasma current, temperature, and density profiles. The control-oriented tokamak simulator (COTSIM), a predictive, control-oriented code, has been enhanced with neural-network surrogates for transport and sources. Turbulent transport is predicted by MMMnet—a neural-network version of the updated multimode model (MMM 9.0.10)—with significantly reduced computation time relative to MMM; neoclassical transport follows the Chang–Hinton model. NUBEAMnet, a surrogate of the Monte Carlo NUBEAM module, predicts beam-driven heating, current, and torque. EC heating and current drive use a control-oriented, empirically scaled source model; plasma resistivity follows the Spitzer formulation; bootstrap current uses the Sauter model. Equilibrium is computed using both prescribed and fixed-boundary solvers (FBSs), and the pedestal structure is modeled with an empirical pedestal model. For a representative DIII-D discharge, COTSIM predicts electron and ion temperature and safety-factor profiles in close agreement with TRANSP predictive and interpretive simulations while extending predictions through the pedestal region to the plasma edge (versus 80% of the minor radius in TRANSP). Furthermore, the equivalent COTSIM simulation runs in under 3 min compared to about 2 h for TRANSP, enabling rapid scenario planning, optimization of tokamak operation, and between-pulse control design.

Control-oriented tokamak simulator (COTSIM)↗

Development in DIII-D of High Beta Discharges Appropriate for Steady-state Tokamak Operation With Burning Plasmas

Ideally, tokamak power plants will operate in steady-state at high fusion gain. Recent work at DIII-D on the development of suitable high beta discharges with 100% of the plasma current generated noninductively (f{sub NI} = 1) is described. In a discharge with 1.5 < q{sub min} <2, a scan of the discharge shape squareness was used to find the value that maximizes confinement and achievable {beta}{sub N}. A small bias of the up/down balance of the double-null divertor shape away from the ion B x {del}B drift direction optimizes pumping for minimum density. Electron cyclotron current drive with a broad deposition profile was found to be effective at avoidance of a 2/1 NTM allowing long duration at {beta}{sub N} = 3.7. With these improvements, surface voltage {approx} 0-10 mV, indicating f{sub NI} {approx} 1, was obtained for 0.7 {tau}{sub R} (resistive time). Stationary discharges with {beta}{sub N} = 3.4 and f{sub NI} {approx} 0.9 that project to Q = 5 in ITER have been demonstrated for {tau}{sub R}. For use in development of model based controllers for the q profile, transport code models of the current profile evolution during discharge formation have been validated against the experiment. Tests of available actuators confirm that electron heating during the plasma current ramp up to modify the conductivity is by far the most effective. The empirically designed controller has been improved by use of proportional/integral gain and built-in limits to {beta}{sub N} to avoid instabilities. Two alternate steady-state compatible scenarios predicted to be capable of reaching {beta}{sub N} = 5 have been tested experimentally, motivated by future machines that require high power density and neutron fluence. In a wall stabilized scenario with q{sub min} > 2, {beta}{sub N} = 4 has been achieved for 2 s {approx} {tau}{sub R}. In a high internal inductance scenario, which maximizes the ideal no-wall stability limit, {beta}{sub N} {approx} 4.8 has been reached with f{sub NI} > 1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural and Fuzzy Adaptive Control of Induction Motor Drives

This paper proposes an adaptive neural network speed control scheme for an induction motor (IM) drive. The proposed scheme consists of an adaptive neural network identifier (ANNI) and an adaptive neural network controller (ANNC). For learning the quoted neural networks, a back propagation algorithm was used to automatically adjust the weights of the ANNI and ANNC in order to minimize the performance functions. Here, the ANNI can quickly estimate the plant parameters and the ANNC is used to provide on-line identification of the command and to produce a control force, such that the motor speed can accurately track the reference command. By combining artificial neural network techniques with fuzzy logic concept, a neural and fuzzy adaptive control scheme is developed. Fuzzy logic was used for the adaptation of the neural controller to improve the robustness of the generated command. The developed method is robust to load torque disturbance and the speed target variations when it ensures precise trajectory tracking with the prescribed dynamics. The algorithm was verified by simulation and the results obtained demonstrate the effectiveness of the IM designed controller.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small Hydropower Plant Response Improvement Using Energy Storage

Small hydropower plants contribute significantly to global power generation. However, due to limited storage, these can have low ramping capacity and poor load-frequency regulation. These can prevent small hydropower plants from being used in isolated grids as backup power to critical loads and rural areas. In this paper, a control architecture for frequency control is proposed that facilitates the use of energy storage to improve the response of standalone small hydropower plants. The frequency controller generates power commands using proportional control on frequency deviation and a user-defined power setpoint, and this incorporates with a current controller that facilitates power injection. The distinctive feature of the controller design is that it takes into account frequency thresholds and storage constraints to enable power injections, and it provides the capability to perform automated and manual recharge of the energy storage. Simulations using detailed nonlinear models demonstrate the improved performance of the hydropower with energy storage using the proposed controller. Automated and manual recharge and the impact of the energy storage constraints on the performance of the hydropower plant are demonstrated.

13 HYDRO ENERGY↗

Neural Lyapunov Control for Power System Transient Stability: A Deep Learning-Based Approach

We report that power system control and transient stability analysis play essential roles in secure system operation. Control of power systems typically involves highly nonlinear and complex dynamics. Most of the existing works address such problems with additional assumptions in system dynamics, leading to a requirement for a complete and general solution. This paper, therefore, proposes a novel control framework for various power system control and stability problems leveraging a learning-based approach. The proposed framework includes a two-module structure that iteratively and jointly learns the candidate Lyapunov function and control law via deep neural networks in a learning module. Meanwhile, it guides the learning procedure towards valid results satisfying Lyapunov conditions in a falsification module. The introduced termination criteria ensure provable system stability. This control framework is verified through several studies handling different types of power system control problems. The results show that the proposed framework is generalizable and can simplify the control design for complex power systems with the stability guarantee and enlarged region of attraction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-dimensional multi-fidelity Bayesian optimization for quantum control

Abstract We present the first multi-fidelity Bayesian optimization (BO) approach for solving inverse problems in the quantum control of prototypical quantum systems. Our approach automatically constructs time-dependent control fields that enable transitions between initial and desired final quantum states. Most importantly, our BO approach gives impressive performance in constructing time-dependent control fields, even for cases that are difficult to converge with existing gradient-based approaches. We provide detailed descriptions of our machine learning methods as well as performance metrics for a variety of machine learning algorithms. Taken together, our results demonstrate that BO is a promising approach to efficiently and autonomously design control fields in general quantum dynamical systems.

Computer Science↗

Harnessing deep reinforcement learning to construct time-dependent optimal fields for quantum control dynamics

Here, we present an efficient deep reinforcement learning (DRL) approach to automatically construct time-dependent optimal control fields that enable desired transitions in dynamical chemical systems. Our DRL approach gives impressive performance in constructing optimal control fields, even for cases that are difficult to converge with existing gradient-based approaches. We provide a detailed description of the algorithms and hyperparameters as well as performance metrics for our DRL-based approach. Our results demonstrate that DRL can be employed as an effective artificial intelligence approach to efficiently and autonomously design control fields in quantum dynamical chemical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Graph Convolutional Network-Based Topology Embedded Deep Reinforcement Learning for Voltage Stability Control

Topological variations in power system is a common phenomenon and can impose significant challenges to traditional controllers of power system. Recent study revealed the strength of deep reinforcement learning (DRL) based approaches in power system preventive and corrective control. But topological variations are difficult to capture using classical fully connected neural network (FCN) model and has not been explicitly modeled in previous work. Hence, we develop a Graph Convolutional Network (GCN) based DRL framework to tackle topology changes in control design of power system. The GCN model exploits the graph structure of the power network and helps the DRL agent to embed the topology information during learning process. Our GCN based approach is evaluated using the IEEE-39 bus system and it outperforms the FCN-based DRL scheme in terms of training convergence and control performance considering grid topology changes.

Hossain, Ramij Raja↗

Active Power Controls from Wind Power: Bridging the Gaps

This paper details a comprehensive study undertaken by the National Renewable Energy Laboratory, Electric Power Research Institute, and the University of Colorado to understand how the contribution of wind power providing active power control (APC) can benefit the total power system economics, increase revenue streams, improve the reliability and security of the power system, and provide superior and efficient response while reducing any structural and loading impacts that may reduce the life of the wind turbine or its components. The study includes power system simulations, control simulations, and actual field tests using turbines at NREL's National Wind Technology Center (NWTC). The study focuses on synthetic inertial control, primary frequency control, and automatic generation control, and analyzes timeframes ranging from milliseconds to minutes to the lifetime of wind turbines, locational scope ranging from components of turbines to large wind plants to entire synchronous interconnections, and additional topics ranging from economics to power system engineering to control design.

17 WIND ENERGY↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

Hydrodynamic Modelling for Tidal Energy Kites: Cooperative Research and Development Final Report, CRADA Number CRD-24-30123

The primary goal of the work is to improve accuracy of hydrodynamic loads acting on the lifting surface of the kite turbine due to complex air-water-lifting body interaction in a low-order numerical model using high-fidelity numerical input. The result of this study will help the Participant better design control algorithms for the kite turbine so that the turbine can harvest more energy while maintaining stability of the platform as well as its reliability. The use of hydrodynamic coefficients/load components from computational fluid dynamic simulation will inform better inputs for a medium-fidelity dynamic model (specifically an OrcaFlex model) which is intended for use in rapid design iterations in the design process.

16 TIDAL AND WAVE POWER↗

Controlling of grid connected photovoltaic lighting system with fuzzy logic

In this study, DC electrical energy produced by photovoltaic panels is converted to AC electrical energy and an indoor area is illuminated using this energy. System is controlled by fuzzy logic algorithm controller designed with 16 rules. Energy is supplied from accumulator which is charged by photovoltaic panels if its energy would be sufficient otherwise it is supplied from grid. During the 1-week usage period at the semester time, 1.968 kWh energy is used from grid but designed system used 0.542 kWh energy from photovoltaic panels at the experiments. Energy saving is determined by calculations and measurements for one education year period (9 months) 70.848 kWh. (author)

14 SOLAR ENERGY↗

Smart building HVAC control challenge: experience and solutions from the ADRENALIN project

A smart building HVAC control competition crowdsourced and compared algorithms on fair and equal ground using the standardized BOPTEST framework. The competition attracted 138 participants, but only 9% submitted valid solutions for the final stage, highlighting the complexity of advanced HVAC control design. The winning solutions showed significant potential to reduce energy use and cost by shifting demand, without compromising occupant comfort. Across scenarios, thermal energy cost reductions of 36–76% relative to a baseline, were achieved. In peak heat periods, the cost reduction leveraged limited energy use reduction (0–15%), but more significant energy price reduction (34–62%). This shows smart controls' ability to avoid as much as possible consumption during the morning peak hours, when spot prices are tendentially the highest. Hosting the competition has highlighted challenges in creating competitions that both are fair and promotes solutions that are transferable to real life implementation.

BOPTEST↗

Development of an Air-Source Heat Pump Integrated with a Water Heating / Dehumidification Module

A residential-sized dual air-source integrated heat pump (AS-IHP) concept is under development in partnership between ORNL and a manufacturer. The concept design consists of a two-stage air-source heat pump (ASHP) coupled on the air distribution side with a separate novel water heating/dehumidification (WH/DH) module. The motivation for this unusual equipment combination is the forecast trend for home sensible loads to be reduced more than latent loads. Integration of water heating with a space dehumidification cycle addresses humidity control while performing double-duty. This approach can be applied to retrofit/upgrade applications as well as new construction. A WH/DH module capable of ~1.47 L/h water removal and ~2 kW water heating capacity was assembled by the manufacturer. A heat pump system model was used to guide the controls design; lab testing was conducted and used to calibrate the models. Performance maps were generated and used in a TRNSYS sub-hourly simulation to predict annual performance in a well-insulated house. Annual HVAC/WH energy savings of ~35% are predicted in cold and hot-humid U.S. climates compared to a minimum efficiency baseline.

dehumidification↗

Wind Energy Modeling and Simulation, Volume 1: Atmosphere and Plant

In order to optimise the yield of wind power from existing and future wind plants, the entire breadth of the system of a plant, from the wind field to the turbine components, needs to be modelled in the design process. The modelling and simulation approaches used in each subsystem as well as the system-wide solution methods to optimize across subsystem boundaries are described in this reference. Chapters are written by technical experts in each field, describing the current state of the art in modelling and simulation for wind plant design. This comprehensive, two-volume research reference will provide long-lasting insight into the methods that will need to be developed for the technology to advance into its next generation. Volume 1 covers the computing challenges in full turbine modelling, then discusses bridging scales in the atmosphere and turbulence modelling, wind forecasting, wind plant flow, and plant level controller design.

17 WIND ENERGY↗