Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

Position sensing circuit for an electrostatically driven MEMS device

The present disclosure relates to a system for detecting movement of a microelectromechanical system (MEMS) device. The system uses a drive voltage signal source for generating a low frequency drive voltage signal for driving the MEMS device. An excitation signal source may be used for generating an excitation signal which is also applied to the MEMS device. The excitation signal has a frequency which is above a physical response capability of the MEMS device, such that operation of the MEMS device is not significantly affected by the excitation signal. A sensing impedance is used to help generate a signal which is responsive to the capacitance of the MEMS device. The capacitance of the MEMS device changes in response to movement of the MEMS device. An output subsystem is provided which responds to changes sensed by the sensing impedance, and which produces an output voltage signal. A filter filters the output voltage signal to produce a filtered output voltage signal. The filtered output voltage signal is indicative of a position of the MEMS device.

Panas, Robert Matthew↗

LINAC Electrical Cabinet - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, circuits, and conduits. In addition, high voltage and low conductivity water (LCW) piping are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model was developed for each cabinet and a Finite Element Analysis (FEA) was performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

Field Testing of PID-p Susceptible Bifacial PERC Modules: Impact of Light, Voltage and Module History ​

This work investigates the potential induced degradation-polarization (PID-p) of bifacial passivated emitter and rear contact (PERC) modules installed in the field at the Florida Solar Energy Center. 22 modules were stressed over 1 year under various voltage (-1500V, -3500, +1500V) and mounting configurations (close to ground, 2 meters from ground, close to roof). The positively stressed modules were anticipated to have experiences PID-p on their front side. However, no degradation was observed, as the light-induced recovery effect effectively counteracted the degradation. The negatively stressed modules experienced Pmax drops during 2 weeks before stabilizing at 5-6% loss. I-V and EL characteristics suggest a PID-p degradation on the rear side. Lower degradation rates are observed with lower voltage and when the mounting configuration allows more albedo light on the rear side to compensate for the degradation. PID-p is observed to stabilize at similar level for the voltage and mounting configuration tested with slightly lower Pmax in winter. EL imaging reveals that cells are not degrading at the same rate across a module. Some cells get darker and then brighter which corresponds to the silicon/passivation interface going through depletion and then inversion when enough positive charges are accumulated. After full light-recovery, the modules were tested again along with 22 brand-new ones to assess the impact of the module history. Results confirmed the trends observed in the first year with PID-p occurring at voltage as low as -600V and recovered modules degrading faster than brand-new ones.

14 SOLAR ENERGY↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

TinyTPC: A TEST STAND FOR LAr DOPING

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) that studies how photosensitive dopants can improve the energy resolution of low energy events in LArTPCs. Bench tests to resolve high voltage breakdown issues and to improve the low voltage system readout are described. Experimental data with a radioactive source of Th-228 for the calibration of the pixelated readout and the characterization of TinyTPC's energy resolution is explained. Provisional results from the addition of isobutylene (photosensitive dopant) and xenon (wavelength shifter) to liquid-argon (LAr) are also presented. Further steps to improve voltage system and enhance the data collection are discussed.

Rodriguez Thorne, Paloma↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability Analysis of Large-Area, Low Pressure-Assisted Silver Sintering for Medium-Voltage Power Modules

Multi-layer insulating ceramic substrates can enable medium-voltage (MV) power modules with reduced peak electric field. This benefit is particularly important for MV silicon carbide (SiC) MOSFETs due to their higher operating voltages. Large-area, low-pressure assisted silver sintering is a potential solution for bonding substrates to create a multi-layer structure. The voiding content and defect density of the bond used to create the multi-layer substrate stack-up is critical to the reliability of the power module and the thermal performance, as this bond is in the primary path for heat dissipation in the power module structure. Here, samples of two-layer direct bonded aluminum (DBA) stacks have been fabricated and subjected to thermal cycling to analyze their reliability. Passive thermal cycling from -40 degrees C to 200 degrees C was performed. Cross-sections were cut at pre-determined intervals and imaged with Scanning Electron Microscopy (SEM). After 1000 thermal cycles, adhesive failures are observed between the sintered silver and the DBA surface. Cross-sections were cut and imaged via optical microscope and SEM. Thermal analyzer measurements are recorded on a 10-kV SiC power module utilizing the sintered DBA substrate stacks.

30 DIRECT ENERGY CONVERSION↗

III-Nitride p-down green (520 nm) light emitting diodes with near-ideal voltage drop

We demonstrate p-down green emitting LEDs with low turn-on voltage enabled by efficient tunnel junctions. Due to the polarization field alignment in the (In,Ga)N/GaN interface with the p-down orientation, the electrostatic depletion barrier for electron and hole injection is reduced when compared with the conventional p-up LEDs. A single (In,Ga)N/GaN heterostructure quantum well active region with a GaN homojunction tunnel junction exhibited very low forward operating voltage of 2.42 V at 20 A/cm 2 with a peak electroluminescence emission wavelength of 520 nm for current densities above 100 A/cm 2 . Furthermore, the bottom tunnel junction with minimal voltage drop enabled excellent hole injection into the bottom p-GaN layer.

36 MATERIALS SCIENCE↗

Optimization of catholyte for halide-based all-solid-state batteries

Halide solid electrolytes gain significant attention due to their high ionic conductivity, low processing temperature, dry air compatibility, and high-voltage stability. However, low cathode active material (CAM) loading in the composite cathode constrains the realization of high energy density for halide-based all-solid-state batteries. In this study, three halide materials, raw Li 3 YBrCl 5 (LYBC-R, <30μm), milled LYBC (LYBC-M, <5 μm) and freeze-dried Li 3 InCl 6 (LIC, <500 nm), were used as catholytes, combined with LYBC-M as the electrolyte and LiIn alloy as the anode. The CAM:catholyte ratio was investigated as well as stack pressure and operating temperature. Our study demonstrates that particle size of the catholyte plays an important role only for high CAM loading or high C-rate cycling. At moderate CAM loading (65 and 70wt% LiNi 0.83 Mn 0.06 Co 0.11 O 2 ) and 0.1 C-rate, all the three catholytes perform well, providing initial discharge capacities >177 mAh/g. At high CAM loading (85wt%) and 0.1 C-rate, a cathode with the nano-scale LIC catholyte provides discharge capacity of 175 mAh/g, while the larger particle size catholytes suffer significantly reduced capacity. Both LYBC and LIC catholytes provided capacity retention >80% after 200 cycles at 0.5C. These results imply that cathode particle size is critically important for performance at high CAM loading. Furthermore, both electrolyte and cathode were tape cast to scale up size and prepare realistic layer thicknesses. A small amount of binder was used in both layers, to balance the electrochemical performance and mechanical properties. Further, the discharge capacity of a tape cell was 152mA h/g at 0.1C with a capacity retention of 81.8% after 20 cycles at 0.5C. The results demonstrate the excellent performance of LYBC as an electrolyte, and provide guidance for halide-based cathode design.

25 ENERGY STORAGE↗

Using Distributed Dynamic Voltage Restorers to Improve the Frequency Stability of Low-Inertia Networked Microgrids

This paper elucidates the novel concept of using distributed dynamic voltage restorers (DVRs), which are traditionally used to compensate for voltage sags, to improve the frequency stability of low-inertia networked microgrids. During frequency transients, the distributed DVRs rapidly regulate load voltages within an acceptable range, resulting in a fast change of load power consumption and helping improve frequency stability. To enable large-scale network simulation, a phasor-based model of DVRs is developed and validated against real data from a commercially available device. Finally, simulation results of a modified IEEE 123-node test feeder that comprises three microgrids and six DVRs verify the effectiveness of the proposed method.

Du, Wei↗

Doping- and Strain-Dependent Electrolyte-Gate-Induced Perovskite to Brownmillerite Transformation in Epitaxial La 1– x Sr x CoO 3–δ Films

Much recent attention has focused on the voltage-driven reversible topotactic transformation between the ferromagnetic metallic perovskite (P) SrCoO 3-&delta; and oxygen-vacancy-ordered antiferromagnetic insulating brownmillerite (BM) SrCoO 2.5 . This is emerging as a paradigmatic example of the power of electrochemical gating (using, e.g., ionic liquids/gels), the wide modulation of electronic, magnetic, and optical properties generating clear application potential. SrCoO 3 films are challenging with respect to stability, however, and there has been little exploration of alternate compositions. Here, we present the first study of ion-gel-gating-induced P. BM transformations across almost the entire La 1-x SrxCoO 3 phase diagram (0 ≤ x ≤ 0.70), under both tensile and compressive epitaxial strain. Electronic transport, magnetometry, and operando synchrotron X-ray diffraction establish that voltage-induced P &rarr; BM transformations are possible at essentially all x, including x ≤ 0.50, where both P and BM phases are highly stable. Under small compressive strain, the transformation threshold voltage decreases from approximately +2.7 V at x = 0 to negligible at x = 0.70. Both larger compressive strain and tensile strain induce further threshold voltage lowering, particularly at low x. The P &rarr; BM threshold voltage is thus tunable, via both composition and strain. At x = 0.50, voltage-controlled ferromagnetism, transport, and optical transmittance are then demonstrated, achieving Curie temperature and resistivity modulations of similar to 220 K and at least 5 orders of magnitude, respectively, and enabling estimation of the voltage-dependent Co valence. The results are analyzed in the context of doping- and strain-dependent oxygen vacancy formation energies and diffusion coefficients, establishing that it is thermodynamic factors, not kinetics, that underpin the decrease in the threshold voltage with x, that is, with increasing formal Co valence. These findings substantially advance the practical and mechanistic understanding of this voltage-driven transformation, with fundamental and technological implications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and Harmonic Stability of MMC-HVDC With Passive Circulating Current Filters

A modular multilevel converter (MMC) is an emerging converter technology widely used in wind power applications using high-voltage direct current (HVDC) transmission, and it has been largely investigated in medium-voltage solar harvesting as well as electric motor drives. Different from studies dealing with active circulating current control loops, this paper focuses on impedance modeling and harmonic stability studies for MMCs with passive circulating current filters (PCCFs). A power stage circuit including a PCCF is transformed and remodeled to obtain small-signal formulations. This transformation leads to additional high-order matrix computing complexity due to the added impedance subnetwork matrix from the PCCF as well as relevant crossed-frequency impacts. To simplify the computational burden, the proposed model aims to solve one arm equation instead of all six MMC arm equations. To achieve this result, additional challenges occur when the MMC is connected to a renewable energy source instead of the grid voltage, where low-level zero-sequence components might exist in the neutral point of three phases, especially in the case of no integrated advanced modular voltage balancing control, which prevents computational simplification. To overcome this challenge, further impedance matrix adjustments are conducted in this paper to theoretically suppress the impact of zero-sequence harmonics when obtaining small-signal impedance, taking into account the frequency coupling effect. Finally, simulations are carried out to validate the developed impedance model under different operating scenarios. Harmonic stability case studies of MMCs with PCCFs connected to renewable energy current sources are also presented, where frequency-domain stability analyses based on Bode diagrams are compared to time-domain simulation waveforms and FFTs, which validate the effectiveness of the proposed impedance model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium-Voltage Isolated Auxiliary Power Supply Design for High Insulation Capability, Ultra-Low Coupling Capacitance, and Small Size

To fully utilize the benefits of medium-voltage (MV) silicon carbide (SiC)-based converter and achieve high power density, the isolated auxiliary power supply (IAPS) needs to be as small as possible. However, the high insulation and low coupling capacitance requirements, considering the high voltage and high dv / dt , are constraints of size reduction. This article proposes an MV IAPS design for high insulation capability, ultra-low coupling capacitance, and small size. The topology selection, efficiency, load regulation, coupling capacitance, and size reduction considerations are discussed. A 2.5 W MV IAPS is designed and built for a 10 kV SiC mosfet -based 13.8 kV/100 kW three-phase converter, achieving a partial discharge (PD) inception voltage of higher than 15 kV rms, ultra-low coupling capacitance of 1.03 pF, and smaller size than that of the commercial products as well as the state-of-art research prototypes. Experimental results of PD test, 10 kV SiC mosfet -based half-bridge test, and 13.8 kV/100 kVA three-phase converter full rating test are conducted for design validation.

42 ENGINEERING↗

Imaging Power Losses in CdSeTe Solar Cells

Much of the research on CdSeTe photovoltaics is focused on improving the open-circuit voltage (V oc ) of the solar cell. But solar cells operate at the maximum power point (MPP) rather than at V oc . The recombination processes at MPP may be different than those at V oc , and increasing the power output at MPP is the key to advancing efficiency. Here, we introduce a camera-based PL imaging system that enables power loss analysis under operating conditions and across cm-sized areas covering multiple cells. The instrument is demonstrated with CdSeTe devices having efficiencies greater than 19%. An implied current density versus implied voltage (iJV) curve can be produced at each pixel with <20 µm resolution. We find that regions with high implied open circuit voltage are often those with low implied fill factor, showing that voltage loss analysis at open circuit is not sufficient to understand power losses under operating conditions. Measurement of JV curves as a function of irradiance can also be performed in the system, which allows series resistance-free pseudo JV (pJV) curves to be produced. Comparison of pJV to measured JV and iJV curves allows further analysis of the operational losses, pointing the way to higher efficiency.

14 SOLAR ENERGY↗

Stabilizing magnesium plating by a low-cost inorganic surface membrane for high-voltage and high-power Mg batteries

Mg batteries with halide-free electrolytes suffer from poor stability of the Mg metal anode due to electrolyte decomposition. Here, we report a low-cost zeolite membrane supported on Mg to address this challenge. It vastly reduces the population (hence decomposition) of free diglyme at the Mg/electrolyte interface, while allowing facile transport of Mg 2+ cations through the membrane. We demonstrate dendrite-free Mg plating/stripping performance in a magnesium tetrakis(hexafluoroisopropyloxy)borate/diglyme electrolyte with a 750-fold extended lifetime (over 6,000 h) and a high coulombic efficiency of ~98%. The prototype Mo 3 S 4 cathode paired with the protected Mg anode shows 91% capacity retention over 200 cycles. Importantly, this membrane protects soluble species in a high-voltage organic polymer cathode from being reduced at the anode via shuttling, achieving a full cell with a 3.5 V cutoff voltage. This results in a high specific energy density of 320 Wh kg –1 and a power density of 1,320 W kg –1 based on cathode mass.

25 ENERGY STORAGE↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗