Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “functionally graded material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

On the impact of indium distribution on the electronic properties in InGaN nanodisks

We analyze an epitaxially grown heterostructure composed of InGaN nanodisks inserted in GaN nanowires in order to relate indium concentration to the electronic properties. This study was achieved with spatially resolved low-loss electron energy-loss spectroscopy using monochromated electrons to probe optical excitations—plasmons—at nanometer scale. Our findings show that each nanowire has its own indium fluctuation and therefore its own average composition. Due to this indium distribution, a scatter is obtained in plasmon energies, and therefore in the optical dielectric function, of the nanowire ensemble. We suppose that these inhomogeneous electronic properties significantly alter band-to-band transitions and consequently induce emission broadening. In addition, the observation of tailing indium composition into the GaN barrier suggests a graded well-barrier interface leading to further inhomogeneous broadening of the electro-optical properties. An improvement in the indium incorporation during growth is therefore needed to narrow the emission linewidth of the presently studied heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

N08C9 (Alliance): A Phase 3 Randomized Study of Sulfasalazine Versus Placebo in the Prevention of Acute Diarrhea in Patients Receiving Pelvic Radiation Therapy

Purpose: To provide confirmatory evidence on the use of sulfasalazine to reduce enteritis during pelvic radiation therapy (RT), following 2 prior single-institution trials suggestive that benefit existed. Methods and Materials: A multi-institution, randomized, double-blind, placebo-controlled phase 3 trial was designed to assess the efficacy of sulfasalazine versus placebo in the treatment of RT-related enteritis during RT including the posterior pelvis (45.0-53.5 Gy) and conducted through a multicenter national cooperative research alliance. Patients received 1000 mg of sulfasalazine or placebo orally twice daily during and for 4 weeks after RT. The primary endpoint was maximum severity of diarrhea (Common Terminology Criteria for Adverse Events version 4.0). Toxicity and bowel function were assessed by providers through a self-administered bowel function questionnaire taken weekly during RT and for 6 weeks afterward. Results: Eighty-seven patients were enrolled in the trial between April 29, 2011, and May 13, 2013, with evenly distributed baseline factors. At the time of a planned interim toxicity analysis, more patients with grade ≥3 diarrhea received sulfasalazine than received placebo (29% vs 11%, P=.04). A futility analysis showed that trial continuation would be unlikely to yield a positive result, and a research board recommended halting study treatment. Final analysis of the primary endpoint showed no significant difference in maximum diarrhea severity between the sulfasalazine and placebo arms (P=.41). Conclusions: Sulfasalazine does not reduce enteritis during pelvic RT and may be associated with a higher risk of adverse events than placebo. This trial illustrates the importance of confirmatory phase 3 trials in the evaluation of symptom-control agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-Driven Surrogate Modeling with Microstructure-Sensitivity of Viscoplastic Creep in Grade 91 Steel

Abstract To support the development of advanced steel alloys tailored to withstand extreme conditions, it is imperative to account for the mechanical performance of components, while considering the influence of local microstructure on the macroscopic response. To this end, this study focuses on the development of microstructure-sensitive constitutive models for the mechanical response of Grade 91 steel exposed to extreme thermo-mechanical environments. Polynomial chaos expansion (PCE) surrogates are used to emulate high-fidelity polycrystal simulations of the viscoplastic response of Grade 91 steel as a function of the microstructure fingerprint (e.g., dislocations and precipitates). To cover a wide temperature–stress domain, two separate PCE surrogates—one that captures softening and the other that captures hardening behavior—are combined using another (sparse) Gaussian process regression model. The resulting constitutive creep surrogate model is integrated within the MOOSE finite element framework to simulate the intricate effects of microstructure, in particular MX-phase precipitates, on a component with a graded microstructure. Surrogate sensitivity analysis is applied to quantify the relevant impact of spatially varying microstructure on the creep response in a test-case involving a Grade 91 alloy with a prototypical weld.

36 MATERIALS SCIENCE↗

Computed Tomography Appearance of Early Radiation Injury to the Lung: Correlation With Clinical and Dosimetric Factors

Purpose: To systematically assess the spectrum of radiologic changes in the lung after radiation therapy for non-small-cell lung cancer. Methods and Materials: We reviewed the cases of 146 patients treated with radical radiotherapy at our institution. All patients had computed tomography (CT) scans performed 3 months after completion of therapy. Radiographic appearances were categorized using a standard grading system. The association of these abnormalities with pretreatment factors and clinical radiation pneumonitis (RP) was investigated. Results: New intrapulmonary abnormalities were seen in 92 patients (63%). These were ground-glass opacity in 16 (11%), patchy consolidation in 19 (13%), and diffuse consolidation in 57 (39%). Twenty-five patients (17%) developed clinical symptoms of RP. Although 80% of the patients with RP had areas of consolidation seen on the posttreatment CT scan, the majority (74%) of patients with such radiographic changes were asymptomatic. For patients with lung infiltrates, the minimum isodose encompassing the volume of radiologic abnormality was usually {>=}27 Gy. Traditional dose-volume metrics, pulmonary function tests, and the coadministration of angiotensin converting enzyme inhibitors (ACE-I) were all strongly correlated with the presence of radiologic injury on univariate analysis (p {<=} 0.002). There was also an inverse correlation between prior smoking history and CT scan changes (p = 0.02). On multivariate analysis, dosimetric parameters and the use of ACE-I retained significance (p = 0.005). Conclusions: Our findings suggest that there is substantial interindividual variation in lung radiosensitivity. ACE-I prevented the radiologic changes seen after high-dose radiation therapy, and their role as radioprotectants warrants further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermionic Energy Conversion Based on Graphene van der Waals Heterostructures

Seeking for thermoelectric (TE) materials with high figure of merit (or ZT), which can directly converts low-grade wasted heat (400 to 500 K) into electricity, has been a big challenge. Inspired by the concept of multilayer thermionic devices, we propose and design a solid-state thermionic devices (as a power generator or a refrigerator) in using van der Waals (vdW) heterostructure sandwiched between two graphene electrodes, to achieve high energy conversion efficiency in the temperature range of 400 to 500 K. The vdW heterostructure is composed of suitable multiple layers of transition metal dichalcogenides (TMDs), such as MoS 2 , MoSe 2 , WS 2 and WSe 2 . From our calculations, WSe 2 and MoSe 2 are identified as two ideal TMDs (using the reported experimental material’s properties), which can harvest waste heat at 400 K with efficiencies about 7% to 8%. To our best knowledge, this design is the first in combining the advantages of graphene electrodes and TMDs to function as a thermionic-based device.

30 DIRECT ENERGY CONVERSION↗

First Annual Report on Pulsed Thermal Tomography Nondestructive Evaluation of Additively Manufactured Reactor Materials and Components: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This report provides results of preliminary performance evaluation of PTT capability in detection of flaws in metallic structures, as well imaging complex geometry AM structures. Performance of PTT was investigated through modeling and experiments, Computer models of PTT were developed using COMSOL Heat Transfer module. Defects were modeled as cylindrical flat bottom holes (FBH), which is a common model of calibrated material flaws in thermal tomography experiments. Materials considered in this study include stainless steel 316 (SS316), stainless steel 304 (SS304), and Inconel 718. Theoretical analyses were conducted to validate inversion of simulated PTT data with COMSOL for a plate. Subsequently, 3D reconstructions were performed on COMSOL simulations for FBH, revealing a decrease in spatial resolution over depth due to thermal diffusion. The results of this study show that the performance of the inversion algorithm for detecting smaller defects depends strongly on the depth of the defect as well as the incident heat flux. The size of detectable defect was estimated by fitting a Gaussian function to surface temperature profile. The criteria for detectability was taken as 20mK noise equivalent temperature difference (NETD), which is currently the sensitivity limit of high-performance infrared cameras. It was determined through computer simulations that the smallest detectable FBH in SS316 has a 50µm diameter and is located 0.5mm below the plate surface. Preliminary experimental studies were performed to evaluate PTT performance in detecting calibrated flaws using metallic specimens with AM defects simulated as drilled-in FBH’s. High strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The diameters of FBH’s varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanical drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. Finally, PTT capability in imaging several AM structures fabricated from Inconel 718 (IN718) powder feedstock was investigated. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of AM IN718 nozzle plate and a particle filter plate. It was shown that PTT can scan through 2/3in-thick Inconel 718 plates in approximately 15s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages. The results demonstrate the capability of PTT in 3-D imaging of complex geometry AM structures. Intermediate results demonstrated in this report will be developed further to investigate detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Men With Intermediate-Risk Prostate Cancer: Analysis of Short- and Medium-Term Toxicity and Quality of Life

Purpose: To determine the short- and medium-term effects of a single high-dose-rate brachytherapy fraction of 15Gy and hypofractionated external beam radiation therapy for prostate cancer. Methods and Materials: Eligible patients had localized prostate cancer with a Gleason score of 7 and a prostate-specific antigen (PSA) concentration of <20 ng/ml or a Gleason score of 6 with a PSA concentration of 10 to 20 ng/ml. Patients received high-dose-rate brachytherapy as a single 15-Gy dose, followed by external beam radiation therapy at 37.5Gy in 15 fractions, and were followed prospectively for toxicity (using Common Terminology Criteria for Adverse Events version 3.0), urinary symptoms (using the International Prostate Symptom Score [IPSS]), erectile function (with the International Index of Erectile Function [IIEF]), and health-related quality of life (with the Expanded Prostate Cancer Index Composite [EPIC]). Clinical examinations and PSA measurements were performed at every visit, and prostate biopsies were repeated at 2 years. The trial accrued 125 patients, with a median follow-up of 1.14 years. Results: Acute grade 2 and 3 genitourinary toxicity occurred in 62% and 1.6% of patients, respectively, and acute grade 2 gastrointestinal toxicity occurred in 6.5% of patients. No grade 3 late toxicity has occurred: 47% of patients had grade 2 genitourinary and 10% of patients had grade 2 gastrointestinal toxicity. Median IPSSs rose from 5 at baseline to 12 at 1 month and returned to 7 at 3 months. Of the total number of patients who were initially potent (IIEF, >21), 8% of patients developed mild to moderate dysfunction, and 27% of patients developed severe erectile dysfunction. Baseline EPIC bowel, urinary, and sexual bother scores decreased by 9, 7, and 19 points, respectively, at 1 year. No patient has experienced biochemical failure, and 16 of the first 17 biopsy results showed no malignancy. Conclusions: Treatment is well tolerated in the short and medium term, with low toxicity and encouraging early indicators of disease control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Progress In Developing Laser Based Post Irradiation Examination Infrastructure

To be able to understand the performance of reactor fuels and materials, irradiated materials must be characterized effectively and efficiently in a high rad environment. The characterization work must be performed remotely and in an environment hostile to instrumentation. Laser based characterization techniques provide the ability to be remote and robust in a hot-cell environment. Laser based instrumentation also can provide high spatial resolution suitable for scanning and imaging large areas. The INL is currently developing three laser based Post Irradiation Examination (PIE) stations for the Hot Fuel Examination Facility at the INL. These laser based systems will characterize irradiated materials and fuels. The characterization systems are the following: Laser Shock Laser based ultrasonic C-scan system Gas Assay, Sample, and Recharge system (GASR, up-grade to an existing system). The laser shock technique will characterize material properties and failure loads/mechanisms in various materials such as LWR fuel, plate fuel, and next generation fuel forms, for PIE in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad bond. The shock wave travels as a compression wave through the material to the free (unconfined) back surface and reflects back through the material under test as a rarefaction (tensile) wave. This rarefaction wave is the physical mechanism that produces internal de-lamination failure. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize debonding caused by the laser shock technique. The laser ultrasonic system will be fully capable of performing classical non-destructive evaluation testing and imaging functions such as microstructure characterization, flaw detection and dimensional metrology in complex components. The purpose of the GASR is to measure the pressure/volume of the plenum of an irradiated fuel element and obtain fission gas samples for analysis. The study of pressure and volume in the plenum of an irradiated fuel element and the analysis of fission gases released from the fuel is important to understanding the performance of reactor fuels and materials. This system may also be used to measure the pressure/volume of other components (such as control blades) and obtain gas samples from these components for analysis. The main function of the laser in this application is to puncture the fuel element to allow the fission gas to escape and if necessary to weld the spot close. The GASR station will have the inherent capability to perform cutting welding and joining functions within a hot-cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risk Factors for Regional Nodal Relapse in Breast Cancer Patients With One to Three Positive Axillary Nodes

Purpose: In many centers, supraclavicular fossa radiotherapy (SCF RT) is not routinely offered to breast cancer patients with one to three positive lymph nodes. We aimed to identify a subgroup of these patients who are at high risk of supra or infraclavicular fossa relapse (SCFR) such that they can be offered SCFRT at the time of diagnosis to improve long term locoregional control. Methods and Materials: We performed a retrospective analysis of the pathological features of 1,065 cases of invasive breast cancer with one to three positive axillary lymph nodes. Patients underwent radical breast conserving surgery or mastectomy. A total of 45% of patients received adjuvant chest wall/breast RT. No patients received adjuvant SCFRT. The primary outcome was SCFR. Secondary outcomes were chest wall/breast recurrence, distant metastasis, all death, and breast-cancer specific death. Kaplan-Meier estimates were used to calculate actuarial event rates and survival functions compared using log-rank tests. Multivariate analyses (MVA) of factors associated with outcome were conducted using Cox proportional hazards models. Results: Median follow-up was 9.7 years. SCFR rate was 9.2%. Median time from primary diagnosis to SCFR was 3.4 years (range, 0.7-14.4 years). SCFR was associated with significantly lower 10-year survival (18% vs. 65%; p < 0.001). Higher grade and number of positive lymph nodes were the most significant predictors of SCFR on MVA (p < 0.001). 10 year SCFR rates were less than 1% in all patients with Grade 1 cancers compared with 30% in those having Grade 3 cancers with three positive lymph nodes. Additional factors associated with SCFR on univariate analysis but not on MVA included larger nodal deposits (p = 0.002) and proportion of positive nodes (p = 0.003). Conclusions: Breast cancer patients with one to three positive lymph nodes have a heterogenous risk of SCFR. Patients with two to three positive axillary nodes and/or high-grade disease may warrant consideration of SCFRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of surface roughness and absorption on light propagation in graded-profile waveguides

This paper examines the effects of surface roughness and absorption on laser light propagation in graded-profile waveguiding structures. We derive analytical expressions for the scattering and absorption coefficients of guided waves and analyse these coefficients in relation to parameters of the waveguiding structure and the roughness of its boundary. A new approach is proposed to measuring roughness parameters of precision dielectric surfaces. Experimental evidence is presented which supports the main conclusions of the theory. (integraled-optical waweguides)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

National Center of Excellence for Energy Storage Technology 168.10 (Final Report for Period 10/1/2010-12/31/2011)

This report documents the performance of the Ohio State University (OSU) and Edison Welding Institute (EWI) in the period from 10/1/2010 to 12/31/2012. The objective of the project is to establish a Center of Excellence that leverages the strengths of the partners to establish a unique capability to develop and transfer energy storage industries to establish a unique capability in the development and transfer of energy storage system technology through a fundamental understanding of battery electrical and thermal performance, damage and aging mechanisms, and through the development of reliable, high-speed processes for joining substrates in battery cell, module and pack assemblies with low manufacturing variability. During this period, the OSU activity focused on procuring the equipment, materials and supplies necessary to conduct the experiments planned in the statement of project objectives. In detail, multiple laboratory setups were developed to enable for characterizing the open-circuit potential of cathode and anode materials for Li-ion batteries, perform experiments on calorimetry, and finally built multiple cell and module battery cyclers to be able to perform aging campaign on a wide variety of automotive grade battery cells and small modules. This suite of equipment feeds directly into the development, calibration of battery models ranging from first principle electrochemical models to electro-thermal equivalent circuit models suitable for use in control and xEV vehicle simulations. In addition, it allows to develop and calibrate ‘aging’ models for Li-ion batteries that enable the development of diagnostics and prognostics tools to characterize and predict battery degradation from automotive usage under a wide array of environmental and usage scenarios. The objective of the EWI work scope is to develop improved processes for making metal-tometal joints in advanced battery cells and packs. It will focus on developing generic techniques for making functional (electrically conductive and mechanically robust) metal-to-metal joints between thin substrates. Joints with multiple layers and bimetallic constituents will be investigated. During the current period of performance, EWI has defined the test matrix to evaluate the application of different welding technologies (laser welding, ultrasonic welding, resistance welding) to specific components of battery cells and modules, such as foils-to-tabs, tabs-to-tabs, and tabs-to-bus bars. The test matrix also includes a range of substrates (aluminum 1145 and 1100, copper 110 and nickel 200 as substrates). Furthermore, a set of procedures was defined to perform mechanical and electrical testing of the samples, including metallography, and non-destructive evaluations. Both on the OSU and EWI, this project enabled to leverage very significant industrial collaborations with a wide array of companies ranging from battery manufacturers and pack integrator all the ways to Tier 1 automotive suppliers and OEMs during the period of exercise of the project, and in the future for years to come.

25 ENERGY STORAGE↗

Long-Term Outcome and Morbidity After Treatment With Accelerated Radiotherapy and Weekly Cisplatin for Locally Advanced Head-and-Neck Cancer: Results of a Multidisciplinary Late Morbidity Clinic

Purpose: To evaluate the long-term outcome and morbidity after intensified treatment for locally advanced head-and-neck cancer. Methods and Materials: Between May 2003 and December 2007, 77 patients with Stage III to IV head-and-neck cancer were treated with curative intent. Treatment consisted of accelerated radiotherapy to a dose of 68 Gy and concurrent cisplatin. Long-term survivors were invited to a multidisciplinary outpatient clinic for a comprehensive assessment of late morbidity with special emphasis on dysphagia, including radiological evaluation of swallowing function in all patients. Results: Compliance with the treatment protocol was high, with 87% of the patients receiving at least five cycles of cisplatin and all but 1 patient completing the radiotherapy as planned. The 5-year actuarial disease-free survival and overall survival rates were 40% and 47%, respectively. Locoregional recurrence-free survival at 5 years was 61%. The 5-year actuarial rates of overall late Radiation Therapy Oncology Group (RTOG)/European Organization for Research and Treatment of Cancer (EORTC) Grade 3 and Grade 4 toxicity were 52% and 25% respectively. Radiologic evaluation after a median follow-up of 44 months demonstrated impaired swallowing in 57% of the patients, including 23% with silent aspiration. Subjective assessment using a systematic scoring system indicated normalcy of diet in only 15.6% of the patients. Conclusion: This regimen of accelerated radiotherapy with weekly cisplatin produced favorable tumor control rates and survival rates while compliance was high. However, comprehensive assessment by a multidisciplinary team of medical and paramedical specialists revealed significant long-term morbidity in the majority of the patients, with dysphagia being a major concern.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent Stereotactic Radiosurgery and Bevacizumab in Recurrent Malignant Gliomas: A Prospective Trial

Purpose: Virtually all patients with malignant glioma (MG) eventually recur. This study evaluates the safety of concurrent stereotactic radiosurgery (SRS) and bevacizumab (BVZ), an antiangiogenic agent, in treatment of recurrent MG. Methods and Materials: Fifteen patients with recurrent MG, treated at initial diagnosis with surgery and adjuvant radiation therapy/temozolomide and then at least 1 salvage chemotherapy regimen, were enrolled in this prospective trial. Lesions <3 cm in diameter were treated in a single fraction, whereas those 3 to 5 cm in diameter received 5 5-Gy fractions. BVZ was administered immediately before SRS and 2 weeks later. Neurocognitive testing (Mini-Mental Status Exam, Trail Making Test A/B), Functional Assessment of Cancer Therapy-Brain (FACT-Br) quality-of-life assessment, physical exam, and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) were performed immediately before SRS and 1 week and 2 months following completion of SRS. The primary endpoint was central nervous system (CNS) toxicity. Secondary endpoints included survival, quality of life, microvascular properties as measured by DCE-MRI, steroid usage, and performance status. Results: One grade 3 (severe headache) and 2 grade 2 CNS toxicities were observed. No patients experienced grade 4 to 5 toxicity or intracranial hemorrhage. Neurocognition, quality of life, and Karnofsky performance status did not change significantly with treatment. DCE-MRI results suggest a significant decline in tumor perfusion and permeability 1 week after SRS and further decline by 2 months. Conclusions: Treatment of recurrent MG with concurrent SRS and BVZ was not associated with excessive toxicity in this prospective trial. A randomized trial of concurrent SRS/BVZ versus conventional salvage therapy is needed to establish the efficacy of this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication and Evaluation of Large Alumina Crucibles by Vat Photopolymerization Additive Manufacturing for High-Temperature Actinide Chemistry

Additive manufacturing (AM) offers opportunities to advance the design and function of ceramic tooling in high temperature actinide pyrochemistry. In technical ceramics such as alumina, conventional forming techniques often restrict design flexibility and can limit experimental progress. In this study, we investigate the use of vat photopolymerization (VP) with commercial resins to fabricate large-scale alumina crucibles, reaching dimensions up to 125 mm, which is significantly larger than typically reported for dense VP ceramics. Notably, these additively manufactured components are produced using consumer-grade hardware, which limits process control, but offers significant upside in scalability and accessibility. Using microscopy and X-ray computed tomography, the VP alumina parts have high bulk densities above 95%, but also the prevalence of AM-induced artifacts and surface defects. Mechanical testing showed these defects to significantly reduce flexural strength and compromise part reliability. Electrorefining trials under sustained exposure to molten salts and metals reveal mixed results, with the AM material exhibiting high chemical compatibility, but mechanical failures due to the reduced strength were prevalent. Our findings illustrate both the promise and current limitations of AM ceramics for actinide chemistry, and point toward future improvements in process optimization, design strategies, and part screening to enhance performance and reliability.

Materials science↗

Phase 3 Trial of Domiciliary Humidification to Mitigate Acute Mucosal Toxicity During Radiation Therapy for Head-and-Neck Cancer: First Report of Trans Tasman Radiation Oncology Group (TROG) 07.03 RadioHUM Study

Purpose: To assess the impact of domicile-based humidification on symptom burden during radiation therapy (RT) for head-and-neck (H and N) cancer. Methods and Materials: From June 2007 through June 2011, 210 patients with H and N cancer receiving RT were randomized to either a control arm or to receive humidification using the Fisher and Paykel Healthcare MR880 humidifier. Humidification commenced on day 1 of RT and continued until Common Terminology Criteria for Adverse Events (CTCAE), version 3.0, clinical mucositis (CMuc) grade ≤1 occurred. Forty-three patients (42%) met a defined benchmark for humidification compliance and contributed to per protocol (PP) analysis. Acute toxicities, hospitalizations, and feeding tube events were recorded prospectively. The McMaster University Head and Neck Radiotherapy Questionnaire (HNRQ) was used for patient-reported outcomes. The primary endpoint was area under the curve (AUC) for CMuc grade ≥2. Results: There were no significant differences in AUC for CMuc ≥2 between the 2 arms. Humidification patients had significantly fewer days in hospital (P=.017). In compliant PP patients, the AUC for CTCAE functional mucositis score (FMuc) ≥2 was significantly reduced (P=.009), and the proportion who never required a feeding tube was significantly greater (P=.04). HNRQ PP analysis estimates also in the direction favoring humidification with less symptom severity, although differences at most time points did not reach significance. Conclusions: TROG 07.03 has provided efficacy signals consistent with a role for humidification in reducing symptom burden from mucositis, but the influence of humidification compliance on the results moderates recommendations regarding its practical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-Ray Diffraction of Slag-Based Sodium Salt Waste Forms

Cementitious materials are used to solidify and stabilize aqueous based radioactive waste containing sodium salts. The types and proportions of cementitious ingredients used to treat aqueous radioactive waste streams containing sodium salts depend on the performance objectives for the waste forms and the compositions of the waste streams. Matrix phases can stabilize certain contaminants (co-precipitation, substitution, ion exchange, and / or sorption), influence processing properties, and are responsible for physical properties and durability of the cured waste forms. Consequently, characterization of the matrix (binder) mineralogy (chemical compositions and crystalline / non crystalline structures) is important for predicting contaminant leaching and evolution of the materials as a function of time and changing conditions This report documents sample preparation and x-ray diffraction results for a series of mixtures of sodium salt waste and cementitious binders. The objective of this study was to provide initial phase characterization for the CBP reference case cementitious salt waste form. This information can be used to: 1) generate a base line for the evolution of the waste form as a function of time and conditions, 2) potentially to design new binders based on mineralogy of the binder, 3) understand and predict anion and cation leaching behavior of contaminants of concern, and 4) predict performance of the waste forms for which phase solubility and thermodynamic data are available. Characterization of the mineralogy is also important for understanding the buffering effects that the waste form has on infiltrating water / leachates. More specifically, identification of hydrated phases capable of sequestering anions in the structures and crystallinity of the calcium silicate binder phases were of particular interest. The intent was to use this characterization data as a starting point for more detailed phase characterization using neutron diffraction techniques in addition to quasi-elastic neutron scattering techniques for characterization of water at the ORNL Spallation Neutron Source, Oak Ridge, TN. The initial characterization is complete. Due to extensive substitutions of cations and anions in the layered double hydroxide phases and the very fine intermixing of poorly crystalline hydrated phases in the reference case blend (10 : 45 : 45 cement : slag : fly ash), electron diffraction and transmission electron spectroscopy are recommended as the next step for characterization. In summary, the hydrated mixtures of Type II portland cement, Grade 100 ground granulated blast furnace slag (GGBFS) and carbon burn-out (CBO) Class F Fly ash contained hydrated phase assemblages which were typical of those reported in the literature. Based on x-ray diffraction results, no significant differences were detected in samples cured 2 months and 14 months in sealed containers at ambient indoor temperatures.

36 MATERIALS SCIENCE↗

Development of local-power-free, remote α -particle detection using optical fibers

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.

alpha particles↗

MAR flow mapping of Analytical Chemistry Operations (Preliminary Report)

The recently released Supplemental Directive, NA-1 SD 1027, updates the radionuclide threshold values in DOE-STD-1027-92 CN1 to reflect the use of modern parameters for dose conversion factors and breathing rates. The directive also corrects several arithmetic errors within the original standard. The result is a roughly four-fold increase in the amount of weapons-grade nuclear material allowed within a designated radiological facility. Radiological laboratory space within the recently constructed Radiological Laboratory Office and Utility Building (RLUOB) is slated to house selected analytical chemistry support activities in addition to small-scale actinide R&D activities. RLUOB is within the same facility operations envelope as TA-55. Consolidation of analytical chemistry activities to RLUOB and PF-4 offers operational efficiency improvements relative to the current pre-CMRR plans of dividing these activities between RLUOB, PF-4, and CMR. RLUOB is considered a Radiological Facility under STD-1027 - 'Facilities that do not meet or exceed Category 3 threshold criteria but still possess some amount of radioactive material may be considered Radiological Facilities.' The supplemental directive essentially increases the allowable material-at-risk (MAR) within radiological facilities from 8.4 g to 38.6 g for 239 Pu. This increase in allowable MAR provides a unique opportunity to establish additional analytical chemistry support functions in RLUOB without negatively impacting either R&D activities or facility operations. Individual radiological facilities are tasked to determine MAR limits (up to the Category 3 thresholds) appropriate to their operational conditions. This study presents parameters that impact establishing MAR limits for RLUOB and an assessment of how various analytical chemistry support functions could operate within the established MAR limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗