Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Heat exchanger life extension via in-situ reconditioning

A method of in-situ reconditioning a heat exchanger includes the steps of: providing an in-service heat exchanger comprising a precipitate-strengthened alloy wherein at least one mechanical property of the heat exchanger is degraded by coarsening of the precipitate, the in-service heat exchanger containing a molten salt working heat exchange fluid; deactivating the heat exchanger from service in-situ; in a solution-annealing step, in-situ heating the heat exchanger and molten salt working heat exchange fluid contained therein to a temperature and for a time period sufficient to dissolve the coarsened precipitate; in a quenching step, flowing the molten salt working heat-exchange fluid through the heat exchanger in-situ to cool the alloy and retain a supersaturated solid solution while preventing formation of large precipitates; and in an aging step, further varying the temperature of the flowing molten salt working heat-exchange fluid to re-precipitate the dissolved precipitate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exchange effects in Coulomb quantum plasmas: Dispersion of waves in 2D and 3D quantum plasmas

We describe quantum hydrodynamic equations with the Coulomb exchange interaction for three and two dimensional plasmas. Explicit form of the force densities are derived. We present non-linear Schrödinger equations (NLSEs) for the Coulomb quantum plasmas with the exchange interaction. We show contribution of the exchange interaction in the dispersion of the Langmuir, and ion-acoustic waves. We consider influence of the spin polarization ratio on strength of the Coulomb exchange interaction. This is important since exchange interaction between particles with same spin direction and particles with opposite spin directions are different. At small particle concentrations n{sub 0}≪10{sup 25}cm{sup −3} and small polarization the exchange interaction gives small decrease of the Fermi pressure. With increase of polarization role the exchange interaction becomes more important, so that it can overcome the Fermi pressure. The exchange interaction also decreases contribution of the Langmuir frequency. Ion-acoustic waves do not exist in limit of large polarization since the exchange interaction changes the sign of pressure. At large particle concentrations n{sub 0}≫10{sup 25}cm{sup −3} the Fermi pressure prevails over the exchange interaction for all polarizations. We obtain a similar picture for two dimensional quantum plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE↗

In Situ X-ray Diffraction Study of Cesium Exchange in Synthetic Umbite

The exchange of Cs{sup +} into H{sub 1.22}K{sub 0.84}ZrSi{sub 3}O{sub 9} {center_dot} 2.16H{sub 2}O (umbite-(HK)) was followed in situ using time-resolved X-ray diffraction at the National Synchrotron Light Source. The umbite framework (space group P2{sub 1}/c with cell dimensions of a = 7.2814(3) {angstrom}, b = 10.4201(4) {angstrom}, c = 13.4529(7) {angstrom}, and {beta} = 90.53(1){sup o}) consists of wollastonite-like silicate chains linked by isolated zirconia octahedra. Within umbite-(HK) there are two unique ion exchange sites in the tunnels running parallel to the a-axis. Exchange Site 1 is marked by 8 member-ring (MR) windows in the bc-plane and contains K{sup +} cations. Exchange Site 2 is marked by a larger 8-MR channel parallel to [100], and contains H{sub 2}O molecules. The occupancy of the Cs{sup +} cations through these channels was modeled by Rietveld structure refinements of the diffraction data and demonstrated that there is a two-step exchange process. The incoming Cs{sup +} ions populated the larger 8-MR channel (Exchange Site 2) first and then migrated into the smaller 8-MR channel. During the exchange process a structural change occurs, transforming the exchanger from monoclinic P2{sub 1}/c to orthorhombic P2{sub 1}2{sub 1}2{sub 1}. This structural change occurs when Cs{sup +} occupancy in the small cavity becomes greater than 0.50. The final in situ ion exchange diffraction pattern was refined to yield umbite-(CsK) with the molecular formula H{sub 0.18}K{sub 0.45}Cs{sub 1.37}ZrSi{sub 3}O{sub 9} {center_dot} 0.98H{sub 2}O and possessing an orthorhombic unit cell with dimensions a = 10.6668(8) {angstrom}, b = 13.5821(11) {angstrom}, c = 7.3946(6) {angstrom}. Solid state {sup 133}Cs MAS NMR showed there is only a slight difference between the two cavities electronically. Valence bond sums for the completely occupied Exchange Site 1 demonstrate that Cs-O bonds of up to 3.8 {angstrom} contribute to the coordination of the Cs{sup +} cation.

43 PARTICLE ACCELERATORS↗

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

High temperature ceramic heat exchanger for solid oxide fuel cell

A ceramic heat exchanger with high effectiveness and low-pressure drop has been developed for application as a cathode air preheater for a Solid Oxide Fuel Cell (SOFC). At the operating conditions of SOFCs, typical metallic alloys as those used in commercial heat exchangers may undergo chromium volatilization, which is a known cathode degradation mechanism that reduces SOFC performance and life. Use of ceramics such as alumina or alumina-silicate instead of chromium-containing metal is one approach to eliminate the effects of chromium on the SOFC cathode. This project leverages the geometric design of a heat exchanger previously prototyped and tested [1] to fabricate a novel heat exchanger made from a ceramic material. All calculations of heat exchanger performance requirements are based on state of the art SOFC operating conditions. The alumina-silicate material selected to fabricate the modular prototype heat exchanger was made via a heat transfer based trade-off analysis that shows that for low pressure-drop devices, flow convection is the limiting heat transfer mechanism, and therefore wall conductivity becomes less relevant to heat transfer effectiveness. The modular design presented allows for incremental aggregation of modules to target a broad range of operating conditions typical of present and upcoming SOFC applications (e.g., 25 to 400 kWe). The completed prototype was subjected to a series of static leak/pressure tests, dynamic pressure drop tests both at ambient and realistic service temperature conditions, and finally to a matrix of heat transfer experiments to fully characterize its heat transfer effectiveness (including tests at hot gas temperatures up to 1033 K or 1400oF). The stand-alone system was demonstrated in the laboratory to successfully satisfy the design criteria at realistic operating conditions, showing a total pressure drop at the design flow of 8 g/sec of 6 kPa (vs. 3.45 kPa approximate requirement). It was also shown to have heat transfer effectiveness of 76% (with 73% being the design requirement). Moreover, the unit was shown to operate leak-free, and the ceramic elements and seals were capable of withstanding the thermal cycling resulting from the testing procedure. The heat exchanger was then integrated into a modified fuel cell test stand and tested at steady state operation. Unfortunately, the level of performance achieved was lower than expected based on laboratory performance tests. This appears to have been the result of an unforeseen loosening of a heat exchanger structural component, which resulted into a leak that prevented proper supply of hot gas to the heat exchanger. However, in general terms, the heat exchanger/fuel cell integration process provides confidence that a future application of the unit with a SOFC is feasible, assuming structural issues are addressed. It is considered that the difficulties encountered at the last stage of the program provided invaluable input in locating shortcomings of the mechanical design and integration approach. A portion of this work was presented at the ASME Power & Energy Conference, in Charlotte, NC, on June 28th 2016 in a paper entitled “Development of a Ceramic Heat Exchanger for Application as Solid Oxide Fuel Cell Cathode Air Preheater” and the corresponding paper was published in the Proceedings of the ASME 2016 Power & Energy Conference, Paper No.: PowerEnergy2016-59333 [8].

20 FOSSIL-FUELED POWER PLANTS↗

Heat Exchanger Performance Impacts on Optimum Cost Conditions in Thermoelectric Energy Recovery Designs

Cost is just as important as power density or efficiency for the adoption of waste heat recovery thermoelectric generators (TEG). Prior work [1] has shown that the system design that minimizes cost (e.g., the $/W value) can be close to the designs that maximize the system’s efficiency or power density, however, it is important to understand the relationship between those designs to optimize TEG performance-cost compromises. Expanding on recent work [1, 2, 3] the impact of heat exchanger conditions on the optimum TEG fill factors and cost scaling of a waste heat recovery thermoelectric generator with a detailed treatment of the hot side exhaust heat exchanger has been investigated further. The effect of the heat lost to the environment and updated relationships between the hot-side and cold-side conductances [4] that maximize power output are considered. The optimum fill factor to minimize TEG energy recovery system costs is strongly dependent on the heat leakage fraction, σ, the mass flow rate of the exhaust, the hot-side heat exchanger effectiveness, heat exchanger UAh, and heat flux. These relationships are explored and characterized for typical exhaust gas-flow conditions to show the inherent design complexities. The heat exchanger costs often dominate the TEG cost equation and it is critical to fully understand the tradeoff between heat exchanger performance, optimum TEG fill factors, and cost to establish potentially optimum design points within the cost-performance design space. This work will explore the design tradeoffs and relationships within the cost-efficiency-power density design space for a typical thermoelectric energy recovery system application. The interplay between optimum TEG fill factors and heat exchanger design can impact system footprint, volume, and mass in weight-sensitive applications. Less-effective, low-cost heat exchangers may outperform higher cost alternatives from a market adoption perspective. This shift of emphasis acknowledging the interdependence of optimum TEG fill factors and heat exchanger performance has significant implications on thermoelectric waste heat recovery systems designs and their operation. In addition, preferred TEG design regimes exist that accommodate reasonable compromises in TE performance and cost. This effort highlights how the optimum fill factor–heat exchanger performance relations couple to these optimum TEG performance-cost domains based on TEG-system-level analyses and provides a focus for future system research and development efforts.

Energy recovery↗

Plate Fin Heat Exchanger Model with Axial Conduction and Variable Properties

Future superconducting radio frequency (SRF) cavities, as part of Project X at Fermilab, will be cooled to superfluid helium temperatures by a cryogenic distribution system supplying cold supercritical helium. To reduce vapor fraction during the final Joule-Thomson (J-T) expansion into the superfluid helium cooling bath, counter-flow, plate-fin heat exchangers will be utilized. Due to their compact size and ease of fabrication, plate-fin heat exchangers are an effective option. However, the design of compact and high-effectiveness cryogenic heat exchangers operating at liquid helium temperatures requires consideration of axial heat conduction along the direction of flow, in addition to variable fluid properties. Here we present a numerical model that includes the effects of axial conduction and variable properties for a plate fin heat exchanger. The model is used to guide design decisions on heat exchanger material choice and geometry. In addition, the J-T expansion process is modeled with the heat exchanger to analyze the effect of heat load and cryogenic supply parameters. A numerical model that includes the effects of axial conduction and variable properties for a plate fin heat exchanger was developed and the effect of various design parameters on overall heat exchanger size was investigated. It was found that highly conductive metals should be avoided in the design of compact JT heat exchangers. For the geometry considered, the optimal conductivity is around 3.5 W/m-K and can range from 0.3-10 W/m-K without a large loss in performance. The model was implemented with an isenthalpic expansion process. Increasing the cold side inlet temperature from 2K to 2.2 K decreased the liquid fraction from 0.856 to 0.839 which corresponds to a 0.12 g/s increase in supercritical helium supply needed to maintain liquid level in the cooling bath. Lastly, it was found that the effectiveness increased when the heat load was below the design value. Therefore, the heat exchanger should be sized on the high end of the required heat load.

43 PARTICLE ACCELERATORS↗

Ion Exchange Column Thermal Modeling: Prevention of Process Effluent Boiling - 18577

The Savannah River Site treats and disposes of legacy high-level waste, which resulted from 60 years of nuclear material production, medical research, and other nuclear related work. Complex mixtures of soluble and insoluble solids occupy tanks of which the South Carolina Department of Health and Environmental Control recognizes as the single largest environmental risk state-wide. The risk is reduced through removal, treatment, and solidification of decontaminated salt waste. Presently, SRS decontaminates the soluble salt component of the waste, a solution containing actinides and cesium, via implementation of the Actinide Removal Process and the Modular Caustic Side Solvent- Extraction Unit. Caustic solvent extraction is set to increase in scale by late 2018, with startup of the newly constructed Salt Waste Processing Facility. In conjunction with Salt Waste Processing Facility startup, Savannah River Remediation has been tasked by the Department of Energy to demonstrate modular ion exchange technology. The Tank Closure Cesium Removal project aims to demonstrate the feasibility of modular ion exchange processes for future Department of Energy applications. The Tank Closure Cesium Removal system is scheduled to begin operation in mid-2018. Dissolved salt solution, or influent, will be fed through a filter and ion exchange columns in lead-lag configuration, producing effluent. The effluent is fed to a separate high-level waste tank, for future disposition at Salt-stone Production Facility. Once the demonstration project is complete, the loaded ion exchange columns will be purged, dried, and placed in interim safe storage, awaiting final disposition. The ion exchange media selected for the Tank Closure Cesium Removal system is Honeywell UOP IONSIV{sup C} R-9120. The media is a prime candidate for separation of cesium from radioactive high-level waste. UOP R-9120{sup C} is inorganic and has high capacity, selectivity, and affinity for cesium. During operation, influent is fed to the ion exchange columns, contacting UOP R-9210{sup C} packed within the media vessel. Contact initiates loading of isotopes, and given ample time the solid phase (ion exchange media) and solution achieve thermodynamic equilibrium. UOP R-9120{sup C} is a prime candidate for separation of cesium and dissolved fission products. Although the properties of UOP R-9120{sup C} are favorable for separation, the same properties lead to accumulation of a heat source in the ion exchange bed. Cesium-137 and its daughter product, barium-137 m, generate a clear majority of heat (i.e. ∼ 94%). During operation salt solution flows through each column and transports heat from the ion exchange bed. Once operation is terminated, the effluent contained within the porous bed volume becomes essentially static. In the absence of engineering controls, the heat generated may boil the effluent. Rapid vaporization of aqueous salt solution would lead to bed over pressurization. Over pressurization and an associated release of high-level waste would result in adverse impacts to human health and the environment. This paper focuses on modeling the heat transfer associated with the Tank Closure Cesium Removal system ion exchange column. The model evaluates the maximum heat generation and the associated radionuclide loadings that prevent boiling within of the media vessel, under no flow conditions. A safety significant control, maintaining loadings less than the established loading limit ensures associated impacts to human health and the environment are prevented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and chemical effects of isopropanol exchange in cement-based materials

Drying cement-based materials is a necessary step to characterize the microstructure by microscopy, adsorption, or mercury intrusion. The isopropanol (IPA) exchange method is commonly used to replace the pore solution prior to drying, as it reduces the capillary pressure and thereby helps to preserve the microstructure of the hydrated cementitious materials. However, some physical and chemical effects of IPA on hydration products have been reported. These effects cannot be completely avoided, but can be reduced by shortening the exchange duration, in particular for effects on ettringite. This study carried out experiments with different exchange durations and IPA removal techniques to address research gaps in the literature. For 1-mm cubes of cement paste with IPA diffusion coefficient of 1 × 10{sup −11} m{sup 2}/s, the compared exchange durations are 5 min, 15 min (value from the literature), 40 min (when the mixture at the sample center achieves 95% of the drop in surface tension from water to IPA), 80 min (when the IPA/water mixture at the sample center reaches an azeotrope), 5 h (when over 99% IPA is replaced at the sample center), and 24 h (prolonged exchange). After IPA exchange, samples were either directly dried at 40 °C with flushing N{sub 2} or washed by diethyl ether prior to N{sub 2} drying. Even though the exchange duration of 40 and 80 min, in theory, can reduce the damage from capillary pressure, the nitrogen adsorption results do not show any advantage in preventing microstructural alteration. The 5-h exchange provided results similar to the 24-h exchange, but the latter induced slightly more serious chemical effects resulting from the longer contact of IPA with hydration products. In addition, the compared IPA removal techniques do not show significant differences. Therefore, this study suggests using small samples (~1 mm) for microstructural studies following IPA exchange for a period corresponding to the time when 99% of the water (mole fraction) at the sample center is replaced.

36 MATERIALS SCIENCE↗

Molecular Dynamics Simulation and Theoretical Analysis of Structural Relaxation, Bond Exchange Dynamics, and Glass Transition in Vitrimers

Vitrimers are a class of polymer networks featuring dynamic covalent cross-links that can undergo associative bond exchange. There has been recent interest in these materials due to their promise as recyclable thermosets or self-healing polymers because of the ability of vitrimer networks to rearrange at the molecular level and undergo macroscopic flow. However, the practical use of these materials often occurs in the supercooled regime or glassy state, where the implications of dynamic bonds are complicated by the interplay between slow activated segmental dynamics, cross-link (i.e., bond-exchange) kinetics, and ultimately material properties. Here, in this paper, we combine coarse-grained molecular dynamics simulation and microscopic statistical mechanical theory to understand how cross-linking kinetics affect material dynamics and how this couples to segmental relaxation of the polymeric network strands across a spectrum of length and time scales, especially in the supercooled regime. We characterize the Kuhn segmental alpha relaxation time and bond exchange time for vitrimer systems across various cross-link densities, temperatures, and bond exchange rates. Simulation and theory both exhibit a bending-up behavior for bond exchange time upon cooling, suggesting a coupling between bond exchange dynamics and segmental relaxation that intensifies with faster bond exchange kinetics. We also found bond exchange dynamics have an impact on Kuhn segment alpha relaxation time, which is most significant at higher cross-link densities. Both these effects are most prominent when the bond exchange time is similar to the Kuhn segment alpha relaxation time, and the resulting coupling of these two relaxation processes is tied to both the probability of a free end to find a bonded pair and the time scale of the constraints imposed by the dynamic cross-links. This relationship is reflected by a cross-link dependence of a theoretical parameter which represents the quantitative degree of coupling between bond exchange and segmental dynamics. Overall, the combination of simulation and theory clarifies the intricate interaction between bond kinetics and segmental relaxation and demonstrates the ability to provide molecular-level insights into vitrimer dynamics over a wide temperature range.

dynamic relaxation↗

Disorder effects on the band structure of ZnGeN 2 : Role of exchange defects

The role of exchange defects on the band structure of ZnGeN 2 is investigated. Exchange defects are defined through the exchange of cations Zn and Ge starting from the ideal Pna2 1 crystal structure, which obeys the local octet rule. Each such exchange creates several nitrogen-centered tetrahedra which violate the local octet rule, although overall charge neutrality is preserved. We study several distributions of exchange defects, some with all antisites making up the exchange defect close to each other and with increasing numbers of exchange defects, and others where the two types of antisites Zn Ge and Ge Zn are kept separated from each other. We also compare the results for these models with a fully random distribution of Zn and Ge on the cation sites. We show that for a single-nearest-neighbor exchange defect, the band gap is narrowed by about 0.5 eV due to two effects: (1) the Zn Ge antisites form filled acceptor states just above and merging with the valence-band maximum (VBM) of perfect crystal ZnGeN 2 and (2) the Ge Zn antisites form a resonance in the conduction band which lowers the conduction-band minimum (CBM). When more exchange defects are created, these acceptor states broaden into bands which can lower the gap further. When tetrahedra occur surrounded completely by four Zn atoms, states even deeper in the gap are found localized all near these tetrahedra, forming a separate intermediate band. Finally, for phase-segregated Zn Ge and Ge Zn , the gap is significantly more reduced, but no separate band is found to occur. The Zn Ge acceptorlike states now form a percolating defect band which is significantly wider and hence reaches deeper into the gap. In all cases, the wave functions near the top of the new VBM remain, to some extent, localized near the Zn Ge sites. For a fully random case, the gap is even more severely reduced by almost 3 eV. The total energy of the system increases with the number of octet-rule-violating tetrahedra and the energy cost per exchange defect of order 2 eV is quite high.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

2011 Performance Assessment Community of Practice Technical Exchange – Summary

The Performance Assessment Community of Practice (PA CoP) was developed in 2008 to improve consistency and quality in the preparation of performance assessments (PAs) and risk assessments across the Department of Energy (DOE) Complex. The term, PA, is used to represent all of these modeling applications in this report. The PA CoP goals are to foster the exchange of information among PA practitioners and to share lessons learned from PAs conducted for DOE, commercial disposal facilities, and international entities. Technical exchanges and workshops are a cornerstone of PA CoP activities. Previous technical exchanges have addressed Engineered Barriers (2009 - http://www.cresp.org/education/workshops/pacop/), the Advanced Simulation Capability for Environmental Management and the Cementitious Barriers Partnership (2010 - http://srnl.doe.gov/copexchange/links.htm). Each technical exchange also includes summary presentations regarding activities at DOE, the Nuclear Regulatory Commission (NRC) and other organizations (e.g., International Atomic Energy Agency (IAEA)) as well as a number of presentations from selected sites to provide insight and perspective from on-going modeling activities. Through the deployment of PA Assistance Teams, the PA CoP has also been engaged in the development of new PAs across the DOE Complex. As a way of improving consistency in the preparation of new PAs, the teams provide technical advice and share experiences, noteworthy practices, and lessons learned from previous Low-Level Waste Disposal Facility Federal Review Group (LFRG) reviews. Teams have provided support for PAs at Hanford, Idaho, Paducah and Portsmouth. The third annual PA CoP Technical Exchange was held on May 25-26, 2011 in Atlanta, GA. The PA CoP Steering Committee Meeting held its first meeting on May 24 prior to the Technical Exchange. Decision making using models and software quality assurance were the topical emphasis for the exchange. A new feature at the 2011 technical exchange was the use of panel discussions to solicit feedback from regulators and practitioners. This report summarizes discussions and recommendations from the steering committee meeting and presentations and feedback obtained at the technical exchange. Appendix I includes the steering committee meeting agenda and Appendix II includes the agenda for the technical exchange and a screenshot of the presentations and video files that are available online.

99 GENERAL AND MISCELLANEOUS↗

Prediction of Total Dissolved Gas Exchange at Hydropower Dams

Total dissolved gas (TDG) supersaturation in waters released at hydropower dams can cause gas bubble trauma in fisheries resulting in physical injuries and eyeball protrusion that can lead to mortality. Elevated TDG pressures in hydropower releases are generally caused by the entrainment of air in spillway releases and the subsequent exchange of atmospheric gasses into solution during passage through the stilling basin. The network of dams throughout the Columbia River Basin (CRB) are managed for irrigation, hydropower production, flood control, navigation, and fish passage that frequently result in both voluntary and involuntary spillway releases. These dam operations are constrained by state and federal water quality standards for TDG saturation which balance the benefits of spillway operations designed for Endangered Species Act (ESA)-listed fisheries versus the degradation to water quality as defined by TDG saturation. In the 1970s, the United States Environmental Protection Agency (USEPA), under the federal Clean Water Act (Section 303(d)), established a criterion not to exceed the TDG saturation level of 110% in order to protect freshwater and marine aquatic life. The states of Washington and Oregon have adopted special water quality standards for TDG saturation in the tailrace and forebays of hydropower facilities on the Columbia and Snake Rivers where spillway operations support fish passage objectives. The physical processes that affect TDG exchange at hydropower facilities have been studied throughout the CRB in site-specific studies and routine water quality monitoring programs. These data have been used to quantify the relationship between project operations, structural properties, and TDG exchange. These data have also been used to develop predictive models of TDG exchange to support real-time TDG management decisions. These empirically based predictive models have been developed for specific projects and account for both the fate of spillway and powerhouse flows in the tailrace channel and resultant exchange in route to the next downstream dam. Currently, there exists a need to summarize the general finding from operational and structural TDG abatement programs conducted throughout the CRB and for the development of a generalized prediction model that pools data collected at multiple projects with similar structural attributes. A generalized TDG exchange model can be tuned to specific projects and coupled with water regulation models to allow the formulation of optimal daily water regulation schedules subject to water quality constraints for TDG supersaturation. A generalized TDG exchange model can also be applied to other hydropower dams that affect TDG pressures in tailraces and can be used to develop alternative operational and structural measures to minimize TDG generation. It is proposed to develop a methodology for predicting TDG levels downstream of hydropower facilities with similar structural properties as a function of a set of variables that affect TDG exchange; such as tailwater depth, spill discharge and pattern, project head, and entrainment of powerhouse releases. TDG data from hydropower facilities located throughout the northwest region of the United States will be used to identify relationships between TDG exchange and relevant dependent variables. Data analysis and regression techniques will be used to develop predictive TDG exchange expressions for various structural categories.

13 HYDRO ENERGY↗

Online Lead/Water Heat Exchanger Sensor/System Feasibility-PNNL (Final Report)

On-line structural health corrosion monitoring in advanced lead fast reactor heat exchangers and molten salt reactor heat exchangers is desirable for detecting tube degradation prior to leaks that may allow mixing of heat exchanger fluids or release of radiological contamination beyond the design containment boundary. This program, On-Line Lead/Water Heat Exchanger Sensor/System Feasibility – PNNL 76092, demonstrates feasibility for an ultrasonic torsional wave mode sensor attached to the outside of a long (30.5-m) heat exchanger tube in the stagnant flow area where the tube joins a heat exchanger plenum and where it is possible to protect a sensor and cable from high-force flows. The sensor must be cable connected to a monitoring instrument near the heat exchanger. The sensor and cable management approach for periodic in-service inspection will be impractical to implement on existing heat exchangers; rather permanently mounted sensors must be installed in conjunction with heat exchanger fabrication. Previous work has shown low-temperature lead zirconate titanate (PZT) piezoceramic sensors are able to detect anomalies of interest in 3.0-m long tubes. These sensors have hereby been extended to a 30.5-m long tube more representative of commercial power heat exchanger designs. The program will continue to investigate higher temperature piezoelectric ceramics and long-term performance of high temperature adhesives and sealants and mechanical pressure coupling for 350-500 °C lead reactor environments and higher temperature (700 °C) molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗