Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Measurement and analysis of solar cell current-voltage characteristics

Approaches to measurement and analysis of solar cell current-voltage characteristics under dark and illuminated conditions are discussed. Measurements are taken with a computer based data acquisition system for temperatures in the range of -100 to +100 C. In the fitting procedure, the various I(oi) and C(i) as well as R(S) and R(SH) are determined. Application to current-voltage analyses of high efficiency silicon cells and Boeing CdS/CuInSe2 are discussed. In silicon MINP cells, it is found that at low voltages a tunneling mechanism is dominant, while at larger voltages the I-V characteristics are usually dominated by emitter recombination. In the case of Boeing cells, a current transport model based on a tunneling mechanism and interface recombination acting in series has been developed as a result of I-V analyses.

Olsen, Larry C.↗

The voltage threshold for arcing for solar cells in Leo - Flight and ground test results

Ground and flight results of solar cell arcing in low earth orbit (LEO) conditions are compared and interpreted. It is shown that an apparent voltage threshold for arcing may be produced by a storage power law dependence of arc rate on voltage, combined with a limited observation time. The change in this apparent threshold with plasma density is a reflection of the density dependence of the arc rate. A nearly linear dependence of arc rate on density is inferred from the data. A real voltage threshold for arcing for 2 by 2 cm solar cells may exist however, independent of plasma density, near -230 V relative to the plasma. Here, arc rates may change by more than an order of magnitude for a change of only 30 V in array potential. For 5.9 by 5.9 solar cells, the voltage dependence of the arc rate is steeper, and the data are insufficient to indicate the existence of an arcing increased by an atomic oxygen plasma, as is found in LEO, and by arcing from the backs of welded-through substrates.

Ferguson, Dale C.↗

Modulated-Voltage Metastable-Ionization Detector

New detector retains sensitivity of conventional ones but automatically reduces voltage to prevent current saturation at higher values, enabling quantitative determination of relative concentrations approaching 100 percent. Detector includes feedback circuitry to prevent current saturation. When detector current begins to exceed threshold, detector high voltage reduced to keep current from rising much more. Recorder output shows detector-current and voltage-reduction signals from gas mixture with constituents both above and below threshold concentration. Those above threshold cause both current and voltage-reduction peaks. Those below threshold give rise to current peaks only.

Carle, Glenn C.↗

Arc lamp power supply using a voltage multiplier

A power supply is provided for an arc discharge lamp which includes a relatively low voltage high current power supply section and a high voltage starter circuit. The low voltage section includes a transformer, rectifier, variable resistor and a bank of capacitors, while the starter circuit comprises several diodes and capacitors connected as a Cockcroft-Walton multiplier. The starting circuit is effectively bypassed when the lamp arc is established and serves to automatically provide a high starting voltage to re-strike the lamp arc if the arc is extinguished by a power interruption.

Leighty, Bradley D.↗

High-Voltage Digital-To-Analog Converter

High-voltage 10-bit digital-to-analog converter operates under computer control to put out voltages up to 500 V at currents up to 35 mA. Circuit includes high-voltage power supply used to generate high-voltage square wave at frequency set by computer at value between 0.2 Hz and 10 Hz. Used to drive 0.02-microfarad, 1-kV capacitor at slewing rate of 1 V/microsecond to provide signal for robotic imaging system.

Huston, Steven W.↗

Current collection by high voltage anodes in near ionospheric conditions

The authors experimentally identified three distinct regimes with large differences in current collection in the presence of neutrals and weak magnetic fields. In magnetic field/anode voltage space the three regions are separated by very sharp transition boundaries. The authors performed a series of laboratory experiments to study the dependence of the region boundaries on several parameters, such as the ambient neutral density, plasma density, magnetic field strength, applied anode voltage, voltage pulsewidth, chamber material, chamber size and anode radius. The three observed regimes are: classical magnetic field limited collection; stable medium current toroidal discharge; and large scale, high current space glow discharge. There is as much as several orders of magnitude of difference in the amount of collected current upon any boundary crossing, particularly if one enters the space glow regime. They measured some of the properties of the plasma generated by the breakdown that is present in regimes II and III in the vicinity of the anode including the sheath modified electrostatic potential, I-V characteristics at high voltage as well as the local plasma density.

Antoniades, John A.↗

LDEF Space Plasma-High Voltage Drainage Experiment post-flight results

The Space Plasma-High Voltage Drainage Experiment (SP-HVDE) was comprised of two identical experimental trays. With one tray located on the leading (ram facing, B10) edge and the other located on the trailing (wake facing, D4) edge of the Long Duration Exposure Facility (LDEF), it was possible to directly compare the effects of ram and wake spacecraft environments on charged dielectric materials. Six arrays of Kapton dielectric samples of 2 mil, 3 mil, and 5 mil thicknesses maintained at +/- 300, +/- 500, and +/- 1000 voltage bias formed the experimental matrix of each tray. In addition, each tray carried two solar cell strings, one biased at +300 volts and the other at -300 volts, to study current leakage from High Voltage Solar Arrays (HVSA). The SP-HVDE provides the first direct, long-term, in-flight measurements of average leakage current through dielectric materials under electric stress. The experiment also yields information on the long term stability of the bulk dielectric properties of such materials. Data and findings of the SP-HVDE are an extension of those from shorter term flight experiments such as the PIX-1 (Plasma Interaction Experiment) and PIX-2 and are therefore valuable in the design and evaluation of long-lived space systems with high voltage systems exposed to the low earth orbital environment. A summary of the SP-HVDE post flight analysis final report delivered to the LDEF Project Office under contract to the National Aeronautics and Space Administration is presented.

Yaung, J. Y.↗

System for improving measurement accuracy of transducer by measuring transducer temperature and resistance change using thermoelectric voltages

A constant current loop measuring system measures a property including the temperature of a sensor responsive to an external condition being measured. The measuring system includes thermocouple conductors connected to the sensor, sensing first and second induced voltages responsive to the external condition. In addition, the measuring system includes a current generator and reverser generating a constant current, and supplying the constant current to the thermocouple conductors in forward and reverse directions generating first and second measured voltages, and a determining unit receiving the first and second measured voltages from the current generator and reverser, and determining the temperature of the sensor responsive to the first and second measured voltages.

Anderson, Karl F.↗

Insulation Requirements of High-Voltage Power Systems in Future Spacecraft

The scope, size, and capability of the nation's space-based activities are limited by the level of electrical power available. Long-term projections show that there will be an increasing demand for electrical power in future spacecraft programs. The level of power that can be generated, conditioned, transmitted, and used will have to be considerably increased to satisfy these needs, and increased power levels will require that transmission voltages also be increased to minimize weight and resistive losses. At these projected voltages, power systems will not operate satisfactorily without the proper electrical insulation. Open or encapsulated power supplies are currently used to keep the volume and weight of space power systems low and to protect them from natural and induced environmental hazards. Circuits with open packaging are free to attain the pressure of the outer environment, whereas encapsulated circuits are imbedded in insulating materials, which are usually solids, but could be liquids or gases. Up to now, solid insulation has usually been chosen for space power systems. If the use of solid insulation is continued, when voltages increase, the amount of insulation for encapsulation also will have to increase. This increased insulation will increase weight and reduce system reliability. Therefore, non-solid insulation media must be examined to satisfy future spacecraft power and voltage demands. In this report, we assess the suitability of liquid, space vacuum, and gas insulation for space power systems.

Qureshi, A. Haq↗

Study of Bulk and Elementary Screw Dislocation Assisted Reverse Breakdown in Low-Voltage (< 250 V) 4H-SiC p(sup +)n Junction Diodes--Part II: Dynamic Breakdown Properties: Dynamic Breakdown Properties - Part 2

This paper outlines the dynamic reverse-breakdown characteristics of low-voltage (<250 V) small-area <5 x 10(exp -4) sq cm 4H-SiC p(sup +)n diodes subjected to nonadiabatic breakdown-bias pulsewidths ranging from 0.1 to 20 microseconds. 4H-SiC diodes with and without elementary screw dislocations exhibited positive temperature coefficient of breakdown voltage and high junction failure power densities approximately five times larger than the average failure power density of reliable silicon pn rectifiers. This result indicates that highly reliable low-voltage SiC rectifiers may be attainable despite the presence of elementary screw dislocations. However, the impact of elementary screw dislocations on other more useful 4H-SiC power device structures, such as high-voltage (>1 kV) pn junction and Schottky rectifiers, and bipolar gain devices (thyristors, IGBT's, etc.) remains to be investigated.

Neudeck, Philip G.↗

High Voltage Design Concepts for Launch Vehicles and Orbital Spacecraft Applications

With the advent of design concepts such as, electromechanical actuation and "more electric" initiatives, has come the need for electrical power buses and electronic equipment to operate at higher than normal dc voltages to meet power requirements while keeping current levels to manageable levels. This new bus voltage has been typically 270 Volts dc nominal for launch vehicles, and 120 Volt dc for the International Space Station. This paper will discuss the new design applications for high voltage dc power in existing and future launch vehicles and spacecraft and the potential problems associated therewith. These new applications must be operational from lift-off, ascent, on orbit and descent in all of the pressure and temperature conditions for each, i.e. through the "Paschen region" twice. This paper will also attempt to stimulate an interest in the academic and professional communities to support and conduct research needed for design data applicable to high voltage dc usage.

Hall, David K.↗

High Voltage TAL Performance

The performance of a two-stage, anode layer Hall thruster was evaluated. Experiments were conducted in single and two-stage configurations. In single-stage configuration, the thruster was operated with discharge voltages ranging from 300 to 1700 V. Discharge specific impulses ranged from 1630 to 4140 sec. Thruster investigations were conducted with input power ranging from 1 to 8.7 kW, corresponding to power throttling of nearly 9: 1. An extensive two-stage performance map was generated. Data taken with total voltage (sum of discharge and accelerating voltage) constant revealed a decrease in thruster efficiency as the discharge voltage was increased. Anode specific impulse values were comparable in the single and two-stage configurations showing no strong advantage for two-stage operation.

Jacobson, David T.↗

Minimum Arc Threshold Voltage Experiments on Extravehicular Mobility Unit Samples

The International Space Station (ISS) is now under construction in Low Earth Orbit (LEO). The process of building the ISS requires that astronauts carry out many Extravehicular Activities. To protect the astronauts form the hazardous space environment, they are required to wear a suit known as the Extravehicular Mobility Unit (EMU). For most Extra-Vehicular Activities (EVAs) the EMU is tethered to ISS via a steel safety tether. During the course of an EVA it is common for the safety tether to contact exposed metal on both the ISS and the EMU. In this case, the single point ground of the EMU would be at the same potential as the ISS with respect to the LEO Plasma. In the event that the metal structure of the ISS begins to charge negative of the plasma potential as a result of electron collection by the ISS photovoltaic arrays, then the EMU would also be driven to a negative potential. Anodized aluminum components on the EMU would then begin to develop a charge across their amortization layer as ions from the plasma are collected. In the case where large negative potentials are applied to the EMU, dielectric breakdown may occur as a large voltage difference is developed across the thin amortization layer (oxide). The resulting arc plasma may in turn couple to the charge accumulated on the nearby ISS anodized debris shields and thereby generate a large current flow through the metal EMU structure. Current flow through the EMU could result in an electrocution hazard for the Crew Member inside the EMU - and therefore represents an important safety concern. To address this concern, a series of experiments have been undertaken. In each experiment specially prepared anodized aluminum samples were placed in a LEO representative plasma and charged until dielectric breakdown occurred in the form of an arc. This process was repeated a number of times for three sets of samples. During each test the arc voltage and current were monitored. A statistical treatment of the arc voltage threshold will be presented. In addition, safe operating voltages for the EMU are suggested.

Schneider, Todd↗

Performance of Li-Ion Cells Under Battery Voltage Charge Control

Li-ion cells manufactured by YTP, SAFT, and MSA have completed 6714, 6226, and 3441 cycles, respectively. An increase in the charge voltage limit was required in all cases to maintain the discharge voltage. SAFT and MSA cells were capable of cycling at -10 C and 0 C with an increase in the charge voltage limit, whereas Yardney cells could not be cycled. Reconditioning improved the discharge voltage of SAFT and MSA cells; it is important to note that the effect has been temporary as in Ni-H and Ni-Cd batteries. It was demonstrated that the charge operation with VT clamp at battery rather than at cell level is feasible. Continuation of testing depends on the health of the cells and on the funding situation.

Vaidyanathan, Hari↗

Boeing's High Voltage Solar Tile Test Results

Real concerns of spacecraft charging and experience with solar array augmented electrostatic discharge arcs on spacecraft have minimized the use of high voltages on large solar arrays despite numerous vehicle system mass and efficiency advantages. Boeing's solar tile (patent pending) allows high voltage to be generated at the array without the mass and efficiency losses of electronic conversion. Direct drive electric propulsion and higher power payloads (lower spacecraft weight) will benefit from this design. As future power demand grows, spacecraft designers must use higher voltage to minimize transmission loss and power cable mass for very large area arrays. This paper will describe the design and discuss the successful test of Boeing's 500-Volt Solar Tile in NASA Glenn's Tenney chamber in the Space Plasma Interaction Facility. The work was sponsored by NASA's Space Solar Power Exploratory Research and Technology (SERT) Program and will result in updated high voltage solar array design guidelines being published.

Reed, Brian J.↗

Plasma Interactions with High Voltage Solar Arrays for a Direct Drive Hall Effect Thruster System

The Environmental Effects Group of NASA s Marshall Space Flight Center (MSFC) is conducting research into the effects of plasma interaction with high voltage solar arrays. These high voltage solar arrays are being developed for a direct drive Hall Effect Thruster propulsion system. A direct drive system configuration will reduce power system mass by eliminating a conventional power-processing unit. The Environmental Effects Group has configured two large vacuum chambers to test different high-voltage array concepts in a plasma environment. Three types of solar arrays have so far been tested, an International Space Station (ISS) planar array, a Tecstar planar array, and a Tecstar solar concentrator array. The plasma environment was generated using a hollow cathode plasma source, which yielded densities between 10(exp 6) - 10(exp 7) per cubic centimeter and electron temperatures of 0.5-1 eV. Each array was positioned in this plasma and biased in the -500 to + 500 volt range. The current collection was monitored continuously. In addition, the characteristics of arcing, snap over, and other features, were recorded. Analysis of the array performance indicates a time dependence associated with the current collection as well as a tendency for "conditioning" over a large number of runs. Mitigation strategies, to reduce parasitic current collection, as well as arcing, include changing cover-glass geometry and layout as well as shielding the solar cell edges. High voltage performance data for each of the solar array types tested will be presented. In addition, data will be provided to indicate the effectiveness of the mitigation techniques.

Schneider, T.↗

High Voltage Solar Array ARC Testing for a Direct Drive Hall Effect Thruster System

The deleterious effects of spacecraft charging are well known, particularly when the charging leads to arc events. The damage that results from arcing can severely reduce system lifetime and even cause critical system failures. On a primary spacecraft system such as a solar array, there is very little tolerance for arcing. Motivated by these concerns, an experimental investigation was undertaken to determine arc thresholds for a high voltage (200-500 V) solar array in a plasma environment. The investigation was in support of a NASA program to develop a Direct Drive Hall-Effect Thruster (112HET) system. By directly coupling the solar array to a Hall-effect thruster, the D2HET program seeks to reduce mass, cost and complexity commonly associated with the power processing in conventional power systems. In the investigation, multiple solar array technologies and configurations were tested. The cell samples were biased to a negative voltage, with an applied potential difference between them, to imitate possible scenarios in solar array strings that could lead to damaging arcs. The samples were tested in an environment that emulated a low-energy, HET-induced plasma. Short duration "trigger" arcs as well as long duration "sustained" arcs were generated. Typical current and voltage waveforms associated with the arc events are presented. Arc thresholds are also defined in terms of vo!tage, (current and power. The data will be used to propose a new, high-voltage (>300 V) solar array design for which the likelihood of damage from arcing is minimal.

Schneider, T.↗

Observation of Dust Stream Formation Produced by Low Current, High Voltage Cathode Spots

Macro-particle acceleration driven by low current, high voltage cathode spots has been investigated. The phenomenon was observed to occur when nanometer and micrometer-sized particles in the presence of a discharge plasma were exposed to a high voltage pulse. The negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provides the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. The particle impact craters observed at the surface of downstream witness badges were documented using SEM and light microscopy.

Foster, John E.↗