Distribution Grid Impacts of Community Solar [Slides]

Community solar (CS) projects often face uncertain interconnection costs and fees associated with distribution grid infrastructure upgrades required to connect the project. These costs can determine the economic viability of a CS project, but they are difficult to assess. Cost uncertainty can discourage new projects and prevent communities from accessing the benefits of community solar projects. At the same time, CS deployment strategies hold potential to defer or avoid some distribution costs due to new loads. To mitigate CS interconnection costs, it is important to find least-cost combinations of distribution system infrastructure solutions (transformer upgrades, reconductoring, voltage regulators, storage), and to understand how location of CS projects within a feeder impact distribution grid upgrade costs. This study aims to quantify CS impacts on the distribution grid and provide policy and regulatory insights and CS deployment strategies to address them. It is the first analysis that has systematically studied the technical impacts of community solar projects on a wide range of distribution feeders using state-of-the-art optimization and power flow tools. The analysis employs Berkeley Lab’s novel Least-cost Optimal Distribution Grid Expansion (LODGE) model, a deterministic version of the REPAIR model, that optimally upgrades hundreds or even thousands of distribution circuits or feeders. This is the first application of the LODGE model. LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate CS in combination with alternative solutions, such as utility-owned storage and downsizing CS capacity. Working with a set of least-cost solutions per feeder allows us to benchmark, compare and find techno-economic trends in CS interconnection.

14 SOLAR ENERGY↗

The Best of the West: Policies and Practices to Support Transition to a Lower-Carbon Electric Sector in the Western Interconnection

This report shows the breadth and diversity of actions being taken throughout the region to move toward a generation-transmission system that enables a clean energy future—one that creates good permanent jobs, protects public health and wildlife, maintains sustainable ecosystems, and assures energy security, reliability and sustainability. These activities, which are either currently in place or being developed, address challenges to improve the Western Interconnection by: 1) expanding the grid’s efficiency; 2) planning grid additions that support clean energy; and 3) integrating the increasing amount of variable generation resources. Collectively these efforts can provide the West with a more efficient, sustainable and low-carbon electric sector. This report focuses on local and regional actions by utilities, sub-regional planning groups, individual states and the Western Electricity Coordinating Council (WECC). National policies and programs are not included in this assessment. This report has two sections—the Summary Report and the Appendix. The Summary Report provides illustrative examples of actions that are shaping the transmission system in the Western Interconnection. The Appendix contains a more comprehensive list of projects and programs. Both the Summary Report and Appendix characterize activities as Incremental Improvements and Transformative Changes in transmission Planning, Pricing and Performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local Dynamic Reactive Power for Correction of System Voltage Problems

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implications of a regional resource adequacy program on utility integrated resource planning: Study for the Western United States

LBNL collaborated with the Western Interstate Energy Board and the University of Texas, Austin to investigate the implications of a regional resource adequacy (RA) program on utility integrated resource planning. This report is focused on an active policy discussion to develop a novel voluntary program to share capacity resource and improve RA in the Western Interconnection. This report identifies two RA components of IRP that will be highly impacted by a regional RA program: resource capacity accreditation and RA targets. There are at least four resources that will require specific attention for their capacity credit calculation: (1) variable renewable resources, (2) demand-side resources, (3) hydropower, and (4) contracts. It will then be necessary to decide on a RA target reliability metric (e.g., a planning reserve margin) that is at least the minimum requirement in IRPs to ensure consistency in RA requirement calculations. The report finds that load forecasting and transmission expansion analyses will be moderately impacted, but that most of IRP components will not be significantly impacted. The report includes (i) a review of traditional resource adequacy practices in IRP; (ii) a case study of an existing regional RA program that interacts with IRP (Southwest Power Pool) and (iii) an overview of the NWPP regional resource adequacy proposal that is the object of this work. This paper does not (1) advocate for or against a regional RA program for the NWPP, (2) make detailed design recommendations for this program, or (3) assess its benefits and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Overview of Inverter-based Resource Interconnection Standards

For the past century, electric power systems have primarily been bulk power systems consisting of generation, transmission, and distribution networks. Now the rapid expansion of distributed renewable power sources (RESs) and the shift from large, conventional synchronous machine resources to smaller-sized resources with diverse generation characteristics become the most significant change in modern power systems. With the increasing penetration of RESs, which are inverter-based resources (IBRs), it is important to develop interconnection standards that define performance and capability criteria for these IBRs. This is necessary to ensure the stable and reliable operation of power systems. This report summarizes the standards for IBRs interconnection in North America.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High-Fidelity Electromagnetic Transient Model of Inverter-based Resources Integrated to an IEEE-9 Bus System for Benchmarking Studies

An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter. These power sources lack the intrinsic behaviors of the standard power plants, presenting specific challenges to system stability. These power sources lack the intrinsic behaviors of the standards power plants and their features are almost entirely defined by the control strategy used on them, presenting specific challenges to system stability as their penetration increases into the already fragile Bulk Power System (BPS). Utilizing renewable energy has a great upside but the electrical industry needs to understand the requirements like performing electromagnetic transient (EMT) simulation studies in planning and/or in interconnection studies. This paper presents the development of a high-fidelity EMT model based on commercial equipment and field parameters, which at the same time aims to study the increasing penetration of IBRs and their impact on the actual BPS. The open-source EMT model developed will be a benchmarking example that can be used to evaluate algorithms in the power grid (including evaluating grid-forming controls, power system monitoring and operation, etc.).

Martinez Montejano, Misael↗

Corrosion and Protection of Metallic Interconnects in Solid Oxide Fuel Cells

Energy security and increased concern over environmental protection have spurred a dramatic world-wide growth in research and development of fuel cells, which electrochemically convert incoming fuel into electricity with no or low pollution. Fuel cell technology has become increasingly attractive to a number of sectors, including utility, automotive, and defense industries. Among the various types of fuel cells, solid oxide fuel cells (SOFCs) operate at high temperature (typically 650-1,000 C) and have advantages in terms of high conversion efficiency and the flexibility of using hydrocarbon fuels, in addition to hydrogen. The high temperature operation, however, can lead to increased mass transport and interactions between the surrounding environment and components that are required to be stable during a lifetime of thousands of hours and up to hundreds of thermal cycles. For stacks with relatively low operating temperatures (<800 C), the interconnects that are used to electrically connect a number of cells in series are typically made from cost-effective metals or alloys. The metallic interconnects must demonstrate excellent stability in a very challenging environment during SOFC operation, as they are simultaneously exposed to both an oxidizing (air) environment on the cathode side and a reducing environment (hydrogen or a reformed hydrocarbon fuel) on the anode side. Other challenges include the fact that water vapor is likely to be present in both of these environments, and the fuel is likely to contain impurities, such as sulfides. Since the fuel is usually a reformed hydrocarbon fuel, such as natural gas, coal gas, biogas, gasoline, etc., the interconnect is exposed to a wet carbonaceous environment at the anode side. Finally, the interconnect must be stable towards any adjacent components, such as electrodes, seals and electrical contact materials, with which it is in physical contact.

01 COAL, LIGNITE, AND PEAT↗

Improving estimates of transmission capital costs for utility-scale wind and solar projects to inform renewable energy policy

Estimating the overall costs of transmission needed to integrate variable renewable energy (VRE) onto the grid is challenging. An improved understanding of these transmission costs would support electricity system planning as VRE penetrations increase. This paper brackets VRE transmission capital costs using multiple approaches based on interconnection studies, actual transmission projects, capacity-expansion simulation models, and aggregated U.S. VRE-related transmission expenditures. Each approach possesses advantages and drawbacks, and combining the approaches lends confidence to the results. The resulting range of average levelized VRE transmission costs is 1– 10 dollars/MWh, which is generally lower than earlier estimates in the literature. These transmission capital costs can increase the direct plant-level levelized cost of VRE by 3%–33%, based on levelized costs of energy of 29– 56 dollars/MWh for utility-scale wind and 36–46 dollars/MWh for utility-scale solar. As VRE deployment continues to expand, policy makers can use this information to (1) assess the benefits of transmission avoidance and deferral when comparing distributed energy resources versus utility-scale projects, (2) evaluate the potential costs of large-scale public transmission investments, and (3) better analyze system-level costs of utility-scale VRE technologies. Future research can expand on the framework presented here by providing a review of operation and maintenance costs for transmission systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Capturing the Impact of Storage and Other Flexible Technologies on Electric System Planning

Power systems of the future are likely to require additional flexibility. This has been well studied from an operational perspective, but has been more difficult to incorporate into capacity expansion models (CEMs) that study investment decisions on the decadal scale. There are two primary reasons for this. First, the necessary input data, including cost and resource projections, for flexibility options like demand response and storage are significantly uncertain. Second, it is computationally difficult to represent both investment and operational decisions in detail, the latter being necessary to properly value system flexibility, in CEMs for realistically sized systems. In this work, we extend a particular CEM, NREL's Resource Planning Model (RPM), to address the latter issue by better representing variable generation impacts on operations, and then adding two flexible technologies to RPM's suite of investment decisions: interruptible load and utility-scale storage. This work does not develop full suites of input data for these technologies, but is rather methodological and exploratory in nature. We thus exercise these new investment decisions in the context of exploring price points and value streams needed for significant deployment in the Western Interconnection by 2030. Our study of interruptible load finds significant variation by location, year, and overall system conditions. Some locations find no system need for interruptible load even with low costs, while others build the most expensive resources offered. System needs can include planning reserve capacity needs to ensure resource adequacy, but there are also particular cases in which spinning reserve requirements drive deployment. Utility-scale storage is found to require deep cost reductions to achieve wide deployment and is found to be more valuable in some locations with greater renewable deployment. Differences between more solar- and wind-reliant regions are also found: Storage technologies with lower energy capacities are deployed to support solar deployment, and higher energy capacity technologies support wind. Finally, we identify potential future research and areas of improvement to build on this initial analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fostering a Guiding Multiscale Model for the Development of Advanced MgB 2 Hydrogen Storage Materials (Final Technical Report)

Project Goal and Objective. The demand for energy and for an upgraded energy infrastructure has steadily grown, as have the needs for energy independence and alternatives to our reliance on petroleum. Hydrogen is considered the most viable fuels for wide-scale implementation in the near future as it is less-polluting, non-toxic, and has more stored energy than petroleum. It is envisioned that hydrogen can eventually become the prime energy carrier, integrating the transportation, grid, and chemical sectors in a way that improves resiliency, diversifies feedstocks, and affords new economic opportunities. A key remaining challenge is the development materials with enhanced gravimetric and volumetric hydrogen storage capacities that offer a higher performance than compressed gas. These materials would eliminate the need for large-scale compression, thereby dramatically reducing the footprint and cost of gas storage. The high gravimetric and volumetric hydrogen capacities of complex hydrides has prompted an intensive investigation of the potential of this class of materials as hydrogen storage media over the past 25 years. Among the many complex hydrides that have been explored, magnesium borohydride, Mg(BH 4 ) 2 , has been found to possess the best combination of practical thermodynamic properties. These include a gravimetric H 2 density of 14.9 wt% H 2 and thermodynamics for the dehydrogenation of Mg(BH 4 ) 2 to MgB 2 (equation 1) (ΔH° = 39 kJ/mol H 2 , ΔS = 112 J/K mol H 2 ) which lie in the narrow window required Mg(BH 4 ) 2 $\Leftrightarrow$ MgB 2 + 4 H 2 (1) for reversibility under moderate pressure and temperature. However, overcoming the extremely slow kinetics of the reversible release of hydrogen by this material in the solid state is a daunting challenge. At temperatures greater than 400 °C, the borohydride releases up to 14 wt% hydrogen giving MgB 2 . We discovered that the direct re-hydrogenation of MgB 2 to Mg(BH 4 ) 2 can be accomplished under 950 bar H 2 at 400 °C. While this demonstrated that complete reversibility can be achieved, the conditions employed are far too extreme for commercial hydrogen storage applications. More recently, we found through US DOE funded research projects (EERE HyMARC and HySCOR), that hydrogen cycling, can be accomplish at much milder conditions upon modification of the borohydride or boride. Guided by these discoveries these discoveries, the objective of this research project was to obtain key information that will enable the development of a model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 . The ultimate goal of our efforts is to attain a model of this transformation that can be utilized to accelerate development further advanced materials. This project directly follows on discoveries that were made over the course of a US DOE, EERE HyMARC project that was focused on improvement of the hydrogen cycling kinetics of modified MgB 2 . We found that that mechanical milling with graphene results the desired, pronounced kinetic enhancement. The dramatic lowering of the conditions required for the hydrogenation of MgB 2 is a significant step towards overcoming its chemical inertness allowing its development as a practical onboard hydrogen storage material. However, the exact nature of the modification(s) of MgB 2 that is responsible for its activation towards hydrogenation is completely unknown. This situation is not unique, as efforts to develop hydrogen storage materials typically have a narrow focus rather than a comprehensive approach that takes atomic level bonding and structure; molecular dynamics; long range, nano- and mesoscale-structure and their interconnection all into account. The goal of this project was the development of a comprehensive, multi-scale computational model of reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 that can be utilized for development of higher performance versions of the modified material. Development of the model requires determination of: 1) the bulk, nano-scale, and meso-scale structural changes occurring at elevated pressure following mechano-chemical modification of MgB 2 ; 2) the reaction pathway of the reversible hydrogenation of MgB 2 to Mg(BH 4 ) 2 ; 3) the effect of elevated pressure and mechano-chemical modification on the chemical reaction pathways; 4) the interactions at solid-gas interfaces; and particle surfaces; and 5) the kinetics and thermodynamic parameters associated with each step of the hydrogenation reaction pathway. This investigation required advanced techniques as preliminary, standard XRD, 11 B NMR, and FTIR analysis showed no signs of material modification. In order to gain this level of understanding of modified MgB 2 , required the teaming of a diverse group of experts and state-of-the art experimental capabilities at the University of Hawaii at Manoa (UHM) and collaborating National Laboratories: Craig Jensen , Department of Chemistry (PI and Project Director), solid state, solution, and high pressure NMR spectroscopy; solid-state synthesis; and high pressure hydrogenation (collaboration with SNL); Godwin Severa , Hawaii Natural Energy Institute (co-PI) calorimetry; infrared and Raman spectroscopy (collaboration with NREL); Dera , high pressure X-ray diffraction including in situ experiments (collaboration with ANL); Hope Ishii , Hawaii Institute of Geophysics electron microscopy investigations (collaboration with LBNL); and Joe Brown , Mechanical Engineering , material electronic structure and electric field effects.

08 HYDROGEN↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Design of Passive Grid-Forming Inverters in Port-Hamiltonian Framework

This article presents a modified dispatchable virtual oscillator control approach for achieving the passivity of gridforming inverters (GFMs), without assuming constant voltage and constant frequency. The proposed control framework utilizes the Port-Hamiltonian (PH) based structure that mimics the behaviors of coupled harmonic oscillators, along with an energy ‘pumpingor-damping’ block and the Control by Interconnection (CbI) technique, to render the inverter passive. Once passivity is achieved, transient stability of the system will be guaranteed. The proposed control framework is composed of three loops: an outer power dispatching loop that generates the voltage and frequency references, a virtual oscillator loop that emulates the spontaneous synchronization of oscillators, and an inductor current loop that maintains lossless interconnection in PH systems. In conclusion, the study shows that the proposed control approach ensures the passivity of GFMs, facilitating the transient stability design of multi-inverter systems, as interconnections of passive systems remain passive and stable.

42 ENGINEERING↗

Design of the Pacific DC Intertie Wide Area Damping Controller

This study describes the design and implementation of a proof-of-concept Pacific DC Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV DCtransmission line in the WI. The control system utilizes real-time phasor measurement unit feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring Proteomes of Robust Yarrowia lipolytica Isolates Cultivated in Biomass Hydrolysate Reveals Key Processes Impacting Mixed Sugar Utilization, Lipid Accumulation, and Degradation

Yarrowia lipolytica is an important industrial oleaginous yeast due to its robust phenotypes for effective conversion of inhibitory lignocellulosic biomass hydrolysates into neutral lipids. While lipid accumulation has been well characterized in this organism, its interconnected lipid degradation phenotype is poorly understood during fermentation of biomass hydrolysates.

proteomic analysis↗

Assessment and Coordination of EVSE Cybersecurity Standards

Cybersecurity certification programs for Electric Vehicle Supply Equipment (EVSE) are fragmented due to no single certification covering all aspects of the device and additionally the existence of multiple programs and under different levels of regulation. These devices are also confronted by the intricate assembly of product software, firmware, and hardware. Devices contain both logical and physical interfaces. These multifaceted devices have vulnerabilities at many levels and interconnect with other potentially vulnerable systems including the electric vehicle, the cloud where data and payment information are stored, and the electric grid and electric grid equipment including utilities. Of the EVSE certification programs that are found, none are directly for the cybersecurity of EVSE. Many standards are for safety, specifically battery safety, some are cybersecurity standards for other types of equipment and can be modeled for EVSE. In specific, ISA/IEC 62443 is found to be significantly in line with EVSE security needs and will be used in future testing to certify EVSE and help guide the project to demonstrate where gaps exist, where strengths lie in the standard and how this can be used to lead the certification efforts in harmonizing EVSE cybersecurity standards. In addition, there are multiple efforts that are currently seeking to build EVSE standards or revise existing standards to address gaps. This effort is seeking to establish a cybersecurity program for EVSE that will inform customers and help increase the level of security across products and state EVSE procurements to achieve consistency across different jurisdictions.

33 ADVANCED PROPULSION SYSTEMS↗

State of the States 2009: Renewable Energy Development and the Role of Policy

As U.S. states increasingly focus on developing renewable energy resources, there is a need to track the progress of development, as well as the policies and support mechanisms being implemented to encourage this development. Beyond tracking, the evaluation of policy measures is necessary to determine their effectiveness, guide future efforts, and efficiently allocate resources. This report addresses each of these needs. It provides a detailed picture of the status of renewable energy development in each of the U.S. states using a variety of metrics and discusses the policies being used to encourage this development. The report then explores the context in which renewable energy development occurs by discussing the factors that can affect the uptake of power generation technologies. The analysis offers suggestions on how policies can be used to address these variables, which leads to tailored policy support that considers the specific circumstances within each state. The analysis presents results of several quantitative evaluation methods that have been designed to explore the link between policy implementation and actual development. Finally, the report discusses contextual factors, aside from policy, that affect renewable energy development. The report concludes with a summary of the main points from each chapter, discussion of next steps, and a list of resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Operating Reserve Reductions from a Proposed Energy Imbalance Market with Wind and Solar Generation in the Western Interconnection

This paper considers several alternative forms of an energy imbalance market (EIM) proposed in the nonmarket areas of the Western Interconnection. The proposed EIM includes two changes in operating practices that independently reduce variability and increase access to responsive resources: balancing authority cooperation and sub-hourly dispatch. As the penetration of variable generation increaseson the power system, additional interest in coordination would likely occur. Several alternative approaches could be used, but consideration of any form of coordinated unit commitment is beyond the scope of this analysis. This report examines the benefits of several possible EIM implementations--both separately and in concert

14 SOLAR ENERGY↗