Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Multiphysics Simulation of the NASA SIRIUS-CAL Fuel Experiment in the Transient Test Reactor Using Griffin

After approximately 50 years, NASA is restarting efforts to develop nuclear thermal propulsion (NTP) for interplanetary missions. Building upon nuclear engine tests performed from the late 1950s to the early 1970s, the present research and testing focuses on advanced materials and fabrication methods. A number of transient tests have been performed to evaluate materials performance under high-temperature, high-flux conditions, with several more experiments in the pipeline for future testing. The measured data obtained from those tests are being used to validate the Griffin reactor multiphysics code for this particular type of application. Griffin was developed at Idaho National Laboratory (INL) using the MOOSE framework. This article describes the simulation results of the SIRIUS-CAL calibration experiment in the Transient Reactor Test Facility (TREAT). SIRIUS-CAL was the first transient test conducted on NASA fuels, and although the test was performed with a relatively low core peak power, the test specimen survived a temperature exceeding 900 K. Griffin simulations of the experiment successfully matched the reactor’s power transient after calibrating the initial control rod position to match the initial reactor period. The thermal-hydraulics model largely matches the time-dependent response of a thermocouple located within the experiment specimen to within the uncertainty estimate. However, the uncertainty range is significant and must be reduced in the future.

33 ADVANCED PROPULSION SYSTEMS↗

Environmental Durability Assessment and Development of Subcomponent Test Methods for Advanced Materials in Marine Energy Applications

Marine energy developers are beginning to rely more heavily on advanced composite materials for their load-bearing structures. Understanding how these materials respond and degrade in harsh marine environments is a complex problem. Much research has been performed at smaller laboratory scales to understand the fundamental physical and chemical degradation mechanisms, but little structural testing research has been performed at larger scales to understand how these physical and chemical interactions scale and how they should be accounted for in the design process. The Advanced Materials project is a multilaboratory research collaboration that addresses these issues with the intention of reducing risks and barriers to marine energy developers wanting to adopt advanced composite materials. The National Laboratory of the Rockies has been playing a leading role in developing larger-scale testing infrastructure and test methods to validate complex numerical degradation models and standardize testing procedures to do so. This paper reviews past structural testing activities, how they have grown into current research activities, and how they will continue to evolve to directly address industry needs. This paper covers key research areas - large-scale water absorption and subsequent structural validation testing, qualification of bolted and adhesive connections, and combined submerged fatigue testing at increasing scales. It provides insights into the complex requirements for testing infrastructure and test method development to effectively qualify materials and certify marine energy structures for harsh marine environments. This research program paves the way for better guidance and standardization within the industry when adopting advanced composite materials.

16 TIDAL AND WAVE POWER↗

Testing convolutional neural network based deep learning systems: a statistical metamorphic approach

Machine learning technology spans many areas and today plays a significant role in addressing a wide range of problems in critical domains,i.e., healthcare, autonomous driving, finance, manufacturing, cybersecurity,etc. Metamorphic testing (MT) is considered a simple but very powerful approach in testing such computationally complex systems for which either an oracle is not available or is available but difficult to apply. Conventional metamorphic testing techniques have certain limitations in verifying deep learning-based models (i.e., convolutional neural networks (CNNs)) that have a stochastic nature (because of randomly initializing the network weights) in their training. In this article, we attempt to address this problem by using a statistical metamorphic testing (SMT) technique that does not require software testers to worry about fixing the random seeds (to get deterministic results) to verify the metamorphic relations (MRs). We propose seven MRs combined with different statistical methods to statistically verify whether the program under test adheres to the relation(s) specified in the MR(s). We further use mutation testing techniques to show the usefulness of the proposed approach in the healthcare space and test two CNN-based deep learning models (used for pneumonia detection among patients). The empirical results show that our proposed approach uncovers 85.71% of the implementation faults in the classifiers under test (CUT). Furthermore, we also propose an MRs minimization algorithm for the CUT, thus saving computational costs and organizational testing resources.

Computer Science↗

Hydraulic Response to Thermal Stimulation Efforts at Raft River Based on Stepped Rate Injection Testing

The injection well stimulation project at the Raft River geothermal field tests the effect of long-term cold water injection and high pressure injection on well injectivity, improvements to which could reduce operating costs. The primary data for analysis and interpretation of the injection test are step-rate flow tests run before each new phase of the injection. These tests were analyzed using a combination of standard pump-test analytical solution methods and methods developed expressly for the observed conditions. The stepped rate injection tests, combined with long-term flow and pressure response data suggest that the well is located within a fractured formation of low transmissivity but high storativity. These calculated parameters appeared to increase with pressure during the first injection test and the higher values were reproduced during the second stepped rate test. Calculated transmissivity and storativity are on the order of 4E-5 m cm 2 and 1E-4 m Pa -1 , respectively. The apparent pressure dependence of fitted hydraulic parameters may reflect near-well fracture compliance that increased the effective radius of the wellbore during the first test. While the type curve fit analysis also suggests that the reservoir behaves as a uniformly fractured reservoir with a radial flow regime, the hydraulic parameters indicate that condition may exist only a very limited distance (<10 m) from the well. Longer-term pressure response suggests that flow in the system effectively reaches steady state in a period of less than a day, which may reflect pressure stabilization resulting from pressure-dependent permeability or a region of much higher permeability located with a few meters of the well. The transmissivity estimates obtained from this analysis, converted to approximate fracture density and aperture, provide useful constraints on the distance to which the thermal front may migrate from the well during the cold water injection phase of the stimulation project. We estimate that the cooling front will migrate less than a tenth of a kilometer over an approximately one-year injection period. Here, the effects of that cooling, however, may be substantial, because increases in permeability have maximum effect nearest the well.

cold water injection↗

Molten salt environment creep testing extensometry system

Disclosed herein are systems, devices and methods for creep testing selected materials within a high-temperature molten salt environment. Exemplary creep testing systems include a load train for holding a test specimen under a load within a heated inert gas vessel. An extensometry system can be included to measure elongation of the test specimen while under load. The extensometry system can include fixed members and axially translating member that move along with the elongation of the test specimen, and the system can include a sensor to measure the relative axial motion between such components to measure elongation of the test specimen over time. The test specimen can include a cylindrical gage portion having an internal void filled with a molten salt during creep testing to simulate the corrosive effect of the molten salt on the specimen material during testing.

Ren, Wenlin↗

Development of Surveillance Test Articles with Reduced Dimensions and Material Volumes to Support MSR Materials Degradation Management

This report details the efforts toward developing new surveillance test article designs with reduced dimensions and material volumes to support materials surveillance technology development for advanced reactors. Two fabrication methods for the surveillance test articles are described. Welded test articles were fabricated with 316H and A617 materials, and interlocking test articles were fabricated using A709 and titanium-zirconium-molybdenum (TZM). The preliminary results demonstrate the successful design and testing of the flat surveillance test articles. The report also describes ongoing efforts to use an induction heating test setup to increase the heat up and cool down rates in testing the surveillance test articles. A brief description of the planned FY-24 work is provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Environmental Durability Assessment and Development of Subcomponent Test Methods for Advanced Materials in Marine Energy Applications: Preprint

Marine energy developers are beginning to rely more heavily on advanced composite materials for their load bearing structures. Understanding how these materials respond and degrade in harsh marine environments is a complex problem. Much research has been performed at smaller laboratory scales to understand the fundamental physical and chemical degradation mechanisms, but little structural testing research has been performed at larger scales to understand how these physical and chemical interactions scale and how they should be accounted for in the design process. The Advanced Materials project is a multilaboratory research collaboration that has been addressing these issues with the intention of reducing risks and barriers to marine energy developers wanting to adopt advanced composite materials. The National Laboratory of the Rockies has been playing a leading role in developing larger scale testing infrastructure and test methods to validate complex numerical degradation models and standardize testing procedures to do so. This paper provides a review of past structural testing activities and how they have grown into current research activities and will continue to evolve into the future to directly address industry needs. This paper covers key research areas large-scale water absorption and subsequent structural validation testing, qualification of bolted and adhesive connections, and conducting combined submerged fatigue testing at increasing scales. This paper provides insights into the complex requirements for testing infrastructure and test method development to effectively qualify materials and certify marine energy structures for harsh marine environments. This research program paves the way for better guidance and standardization within the industry when adopting advanced composite materials.

16 TIDAL AND WAVE POWER↗

Advances in benchmarking and round robin testing for PEM water electrolysis: Reference protocol and hardware

While the number of publications in the PEM water electrolysis community increases each year, no common ground concerning reference hardware (test cells and test bench) and testing protocols has been yet established. This would, however, be necessary for the comparability of experimental results. First attempts for such reference hardware and procedures have been made in the framework of the Task 30 Electrolysis within the Technology Collaboration Programme on Advanced Fuel Cells (AFC TCP) of the International Energy Agency (IEA). Since then, improvements of both the test hardware (test cell and components) as well as the measurement protocol were identified, and a revised methodology and key results based on a comprehensive measurement series have been obtained. A detailed protocol for testing commercial reference components with a reference laboratory test cell developed in-house by Fraunhofer ISE is presented. For evaluation of the protocol and the hardware, it was tested at three different institutions at the same time. Impedance spectroscopic and polarization data was acquired and analyzed. The obtained differences in performance were calculated to give the community an expectation window to compare own data to. Finally, the importance of a thorough temperature control and the conditioning phase are demonstrated.

08 HYDROGEN↗

Preliminary Evaluation of Driver Fuel Plates and Reduced Sodium Temperature to Increase Fast Test Reactor Experimental Neutron Irradiation Capabilities

All sodium-cooled fast test reactors operated so far have used essentially the same fuel geometrical ar-rangement, namely cylindrical fuel pins assembled into a triangular array in hexagonal fuel assemblies. Fuel compositions and dimensions may vary but the overall geometrical pattern remains identical. Fur-thermore, most sodium-cooled reactors have operated, and still operate, with core-average inlet and outlet sodium temperatures of, respectively, 350-400°C and 500-550°C. The present preliminary study revisits the standard fuel assembly geometry as well as operating tempera-tures to evaluate potential impact on fast test reactor neutron irradiation capabilities. The reference fuel is U-20Pu-10Zr. Pin (reference) and plate geometries are considered together with two sets of core-average sodium inlet/outlet temperatures: 350/500°C (reference) and 200/400°C. More prototypic environments could be obtained inside ad-hoc irradiation testing vehicles that are independent from the reactor primary coolant. Everything else being the same, fuel temperature is significantly lower in plates than in pins. Therefore, plates could in principle accommodate higher plutonium content, thus, reducing the need for uranium enrichment or allowing the use of lower quality plutonium (U-xPu-10Zr thermal conductivity and solidus temperature decrease as x increases, hence, necessitating additional thermal margins). For the reference pin configuration, lowering the inlet/outlet sodium temperatures from the reference 350/500°C down to 200/400°C provides additional thermal margins that can be used to increase the peak fast flux from about 4.5 × 10 15 n/cm 2 -s to 6 ×10 15 n/cm 2 -s for the same core power of 300 MW. Assuming 300 Equivalent Fuel Power Days (EFPD) of operation per calendar year, a (steel) test article could accu-mulate up to 75 dpa/year. The use of fuel plates provides even more thermal margins which may allow the peak fast flux to reach values as high as 8 × 10 15 n/cm 2 -s for both sets of inlet/outlet temperatures. In this environment, a test article could accumulate up to 95 dpa/year assuming 300 EFPD/year, hence greatly accelerating irradiation testing. Allowing a fast test reactor to operate over a wide range of inlet/outlet temperatures could add significant flexibility to its neutron irradiation capabilities. Steel present in the driver fuel assemblies is not expected to accumulate more than 90 displacements per atom (dpa) over its lifetime. Hence, steel alloys that are not suited for very high dpa but can operate over a wide range of temperatures (from low to high) would be appropriate for this application. Finally, because pin and plate assemblies fit on the same grid plate, a fast test reactor could in principle start-up with standard fuel pin assemblies and, later on, move to a plate-type Mark-II fuel to further in-crease its neutron irradiation capabilities while potentially reducing the level of uranium enrichment needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Maximizing Efficiency and Quality: Leveraging Automated Testing for Laboratory Commissioning

The traditional commissioning process for a building often implements sampling rates to select equipment for functional acceptance testing when large quantities of equipment are present. While this approach is generally effective in identifying wide-spread issues, it has several key shortfalls. (1) It provides a one-time validation of equipment operation in which the standard documentation is a simple checklist of pass/fail questions. (2) It fails to evaluate equipment not included in the sample rate selection. During the construction and commissioning process of the new Research and Innovation Laboratory (RAIL) in Golden, CO, the National Renewable Energy Laboratory team engaged Group14 Engineering to implement a Connected Commissioning process using fault detection and diagnostic software for automated functional acceptance testing. The goal of this presentation will be to highlight the advantages offered by automated functional testing in this critical laboratory setting. These are primarily (1) sampling 100% of BAS-connected equipment during functional testing, (2) testing results backed by data beyond the traditional pass/fail checklist, and (3) an automated test process that can be regularly executed by the building management team for ongoing commissioning throughout the life of the building. The presentation will also cover technical challenges associated with connected commissioning and the important conversations with the key stakeholders that need to occur well before functional acceptance testing in order to successfully implement the automated testing processes.

automated testing↗

Maximizing Efficiency and Quality: Leveraging Automated Testing for Laboratory Commissioning

The traditional commissioning process uses sampling to select equipment for functional acceptance testing when large quantities of equipment are present. Although this approach is generally effective in identifying wide-spread issues, it has several shortcomings: it fails to evaluate equipment not included in the sample, provides only a one-time validation of equipment operation, and the standard documentation is a simple checklist of pass/fail questions. During the construction and commissioning process of the new Research and Innovation Laboratory (RAIL) in Golden, CO, the National Renewable Energy Laboratory team engaged Group14 Engineering to implement a Connected Commissioning process using fault detection and diagnostic software for automated functional acceptance testing. This presentation highlights the advantages offered by automated functional testing in this critical laboratory setting: (1) sampling 100% of BAS-connected equipment during functional testing, (2) testing results backed by data beyond the traditional pass/fail checklist, and (3) an automated test process that can be regularly executed by the building management team for ongoing commissioning throughout the life of the building. The presentation will also cover technical challenges associated with Connected Commissioning and the important conversations with key stakeholders that need to occur well before functional acceptance testing in order to successfully implement the automated testing processes.

automated testing↗

High strain rate nanoindentation testing: Recent advancements, challenges and opportunities

Recent advancements in electronics have renewed the interest in high strain rate nanoindentation testing, resulting in the development of new high strain rate nanoindentation test equipment and test methodologies. Here, in this work, the current state-of-the-art in high strain rate nanoindentation testing is critically reviewed, with focus on three key aspects - the testing equipment's dynamic mechanical and electronic response, test methodology, and post-processing of raw data to obtain hardness and strain rate. The challenges in instrument hardware design and post-test data analysis are discussed, along with optimal strain rate window for accurate high strain rate measurements. Specific focus will be on instrumented high strain rate testing using self-similar indenters at strain rates in excess of 100 s -1 , wherein load and depth of penetration into the sample are both measured or applied.

36 MATERIALS SCIENCE↗

Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests

The hot box test method has been applied to evaluate both the steady-state (U-value) and dynamic thermal properties of building envelopes. However, the high construction cost of full-scale hot box apparatus and the testing time required (usually several days) may prevent its wider adoption. To overcome the limitations of full-scale hot box tests, here we propose a novel method to evaluate the dynamic thermal performance of building envelope components using a small-scale calibrated hot box and scaled-down specimen. In this paper, the scaling relationships of thermal properties evaluated using a full-size specimen and a scaled-down specimen are established based on the Laplace transform of the heat transfer equations. In addition, dynamic thermal properties obtained from scaled-down experimental tests are compared to the values calculated by the EN ISO13768 (ISO) method. A small-scale hot box with a 355 mm × 355 mm metering area was constructed and calibrated to validate the correlations. Three scaled-down concrete sandwich wall panels were then tested and the scaling relationship was cross-validated using the experimental results, finite difference (FD) simulations, and the ISO method. The results indicate that the dynamic thermal properties obtained from a scaled-down hot box test can be correlated to its full-size counterpart when certain conditions are met. The scaled-down hot box test is demonstrated to be an effective yet economical alternative to a full-scale test with significantly reduced experimentation cost and turn-around time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid oxide electrolysis cell and stack testing best practices

Solid oxide electrolyzer (SOE) technology is an emerging method for hydrogen production, noted for its superior electrical efficiency. Despite the significant progress made in recent years, the broad development of SOE technology is often constrained by the necessary and extensive "skill of the craft" required to successfully test simple single cell test articles. This may be linked to the dearth of practical and pragmatic guidance within the literature for safe, reliable, and performant test equipment and test procedures. Researchers at the Idaho National Laboratory (INL) have been actively testing SOEs ranging from button cells to stacks up to 500 kW, in collaboration with industry and other national laboratories. Based on operational experience, INL has developed system design procedures that ensure safe and reliable operation of SOE systems with the level of support required for each test. This paper presents key aspects of SOE stack and system testing, including safe design procedures, balance of plant components design, and specific implementations at INL. Practical design details of reactants, heat, and power management are presented along with lessons learned from the SOE test facility operations at INL.

08 HYDROGEN↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

A numerical and experimental approach to compare the effect of sample thickness in small in-situ SEM and large ex-situ tensile testing in Alloy 709

ASTM standards for tensile tests define specific sample size requirements regardless of grain size of the material. However, sample size requirements for testing should be considered in conjunction with the number of grains within its reduced cross-sectional area. This is particularly important for in-situ Scanning Electron Microscope (SEM) tensile tests, as they have to be conducted on smaller samples. In this study, a comprehensive experimental and numerical evaluation of the effect of specimen thickness (and the resulting number of grains within the cross-section) were conducted using in-situ SEM tensile test (on submillimeter thick samples) and ex-situ tensile tests (on samples of 0.68–5.9 mm thickness) and the results are compared with FEM simulations outcome. All tests were conducted at room temperature and the results are correlated to the number of grains within the thickness of specimens. The tensile test results indicated that even though the 0.2% proof stress and the tensile strength do not vary for the current range of thicknesses (with number of grains in the cross-section varying from 13 to 118), a difference in necking mechanism exists. Post tensile strength, thinner samples undergo more shear failure and diagonal localized necking whereas thicker samples experience more diffuse necking indicated by decreased area of shear failure at the edges and increased area of dimpled tensile failure at the center of the sample. Further, FEM results complement the experimental findings by showing the formation of conjugated localized shear bands on the upper and lower surface in the 0.68 mm thick sample and shear bands combining to form singular shear bands in thicker samples. These results also confirm the validity of the in-situ SEM tensile tests conducted on thinner samples as long as the required minimum number of grains exist within the cross-section.

36 MATERIALS SCIENCE↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗