The dynamic characteristics of human skeletal muscle modeled from surface stimulation
Dynamic characteristics of human skeletal muscle modeled from surface stimulation
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Dynamic characteristics of human skeletal muscle modeled from surface stimulation
Preliminary results on thermally stimulated exoelectron emission from Apollo 12 lunar materials
Radio telemetry stimulator for conditioning large animals by applying high voltage short duration pulses to skin surface
Ultrashort pulse formation in short pulse stimulated Raman oscillator, achieving partial group velocity matching
The deconditioning effects of weightlessness on the cardiovascular system of astronauts are discussed. It is believed that man cannot tolerate indefinite exposure to weightlessness without considerable circulatory deterioration. Analyses of data collected from space flights to date substantiate these beliefs, and confirm the fact that some form of compensation must be provided to keep the cardiovascular system of space travelers properly conditioned. Sequential pulsatile devices were investigated to produce periodic hydrostatic pressure gradients in the venous system of eight subhuman primates. Intermittent venous pooling of blood in the extremities triggers and stimulates the vascular reflex mechanisms of the cardiovascular system that may have significant benefits in maintaining the circulatory system in proper tone under weightless conditions. Electrocardiograms, blood pressure measurements, cardiac output and stroke volume determinations were used to evaluate the efficiency of the described technique. Results were amazingly consistent to indicate an efficient system for intermittently exercising the heart within safe and medically acceptable limits.
The basal level of mean renal nerve activity (MRNA-0) measured in anesthetized cats was found to be modified by the additive interaction of hypothalamic and baroceptor reflex influences. Data were collected with the four major baroceptor nerves either intact or cut, and with mean aortic pressure (MAP) either clamped with a reservoir or raised with l-epinephrine. With intact baroceptor nerves, MRNA stayed essentially constant at level MRNA-0 for MAP below an initial pressure P1, and fell approximately linearly to zero as MAP was raised to P2. Cutting the baroceptor nerves kept MRNA at MRNA-0 (assumed to represent basal central neural output) independent of MAP. The addition of hypothalamic stimulation produced nearly constant increments in MRNA for all pressure levels up to P2, with complete inhibition at some level above P2. The increments in MRNA depended on frequency and location of the stimulus. A piecewise linear model describes MRNA as a linear combination of hypothalamic, basal central neural, and baroceptor reflex activity.
The results of numerical calculations of the transient stimulated Raman scattering reported previously have been verified experimentally under conditions where both linear dispersion and self-focusing effects were negligible. The existence of a delay between maxima of the laser and Stokes pulses is experimentally demonstrated for the first time, while the pulse shortening in time via Raman scattering is established more firmly than in previous work. The incident-laser-pulse duration, generated-Stokes-pulse duration, and delay between intensity maxima for the laser and Stokes pulses were measured with the two-photon absorption-fluorescence technique. The effective phonon-dephasing time is determined via spontaneous Raman scattering. By using these measured quantities, inferences are made as to the magnitude of the transient gain and the shape of the exciting picosecond laser pulse.
A temperature controller is described which enables the temperature of a sample mounted on a cold finger to be varied linearly with time. Heating rates between 0.5 and 10 K/min can be achieved for temperatures between 90 and 300 K. Provision for terminating the sample heating at any temperature between these extremes is available. The temperature can be held at the terminating temperature or be reduced to the starting temperature in a matter of minutes. The controller has been used for thermally stimulated conductivity measurements and should be useful for thermoluminescence measurements as well.
Stimulated parametric fluorescence emission tunable over the range from 0.96 to 1.16 microns has been obtained using a barium sodium niobate crystal pumped by a frequency-doubled and mode-locked neodymium:glass laser. The pump radiation in the form of a train of picosecond pulses produced infrared parametric fluorescence pulses, less than 10 psec in duration and with average peak powers on the order of 300 W when pumped with a power density of 300 MW/sq cm.
Data are presented on observations made in the ionospheric plasma that provide evidence for the stimulation of Harris type instabilities at nf sub H in a single electron transition. An illustration is also given of the change in shape of the dispersion curve for a given nf sub H as the upper hybrid frequency crosses the nf sub H value. It was concluded that the instability can exist near nf sub H only when the hybrid frequency nf sub H.
Observations made with a sweep frequency rf sounder on the satellite ISIS 1 in the topside ionosphere are reported, and the interpretation of diffuse signals at the lower harmonics of the electron cyclotron frequency is discussed. These signals are attributed to the stimulation of Harris instabilities of longitudinal plasma waves at multiples of the cyclotron frequency in a single electron distribution. The Harris instability is excited most readily when the frequency is near the midpoint between the harmonics of the cyclotron frequency. The cause of these instabilities is the large electron velocity anisotropy which results from collisionless cyclotron damping of the energy from the high power sounder pulse.
Tunable stimulated Stokes emission is generated at approximately 2.9 microns in barium vapor with an oscillator-amplifier dye laser. The conversion efficiency is as high as 40% and the energy output as high as 30 mJ. The emission is tuneable over about 100 wavenumbers. At high vapor pressures the tuning profile is markedly asymmetric.
Observations of stimulated Brillouin scattering from an underdense plasma in a magnetic field are reported. The observed shifts correspond to those expected from a plasma with the measured temperature. Scattering with twice the Brillouin shift was observed when the fundamental Brillouin reflectivity approached 5%.
The smooth portion of the horizontal vestibulo-ocular reflex was analyzed in terms of the frequency response, relating slow-phase eye velocity to angular velocity of a rotating chair under four different cases: sinusoidal rotation about a vertical axis in total darkness, sinusoidal rotation during afterimage tracking, pseudorandom head rotation in total darkness, and pseudorandom head rotation during afterimage tracking. Eye movements were recorded using a photoelectric limbus tracking method. The observation that the presence of an afterimage during vestibular stimulation increases the velocity of slow-phase eye movements is in support of the theory that such slow-phase movements are generated, at least in part, by the perceived velocity of the target. Since the target is immobilized on the retina, this perceived velocity is clearly not generated by retinal slip, but rather by a mechanism related to the eye movement such as corollary discharge.
The results of a systematic series of experiments to uncover possible correlation between laser-induced stimulated-Brillouin-scattering (SBS) phonons and damage in quartz are presented. Such correlation is confirmed and the various thresholds are established. The anomalous transmission factor under phonon generation is found to decay exponentially as predicted with increasing incident laser power. The LF SBS phonon is also demonstrated to be a sensitive probe for precatastrophic damage.
Stimulated Raman scattering of the intense 22.2-GHz water-vapor maser radiation within W49 is examined as a possible explanation of the extremely broad spectrum of W49 extending to + or - 200 km/sec apparent Doppler velocity. Under the most favorable conditions, Raman scattering from ammonia molecules is calculated to be observable. It is unlikely that the Raman process contributes appreciably in the case of W49, as it fails to predict the observed spatial and spectral distribution of the radiation.
It was demonstrated that the thickness of the stimulator titanium enclosure is directly related to the battery recharge time cycle. Reduction of the titanium enclosure thickness from approximately 0.37 mm (0.015 inch) to 0.05 mm (0.002 inch) significantly reduced the recharge time cycle and thereby patient inconvenience. However, fabrication of titanium enclosures from the thinner material introduced problems in forming, holding, and welding that required improvement in state of the art shop practices. The procedures that were utilized to resolve these fabrication problems are described.
Long-term, periodically repeated caloric stimulation of the labyrinth receptors of the internal ear was studied on eight rabbits with immobilzed heads. Warm (20 C) water was used as a stimulus in a dose of 40 ml per min injected into the auditory meatus.